Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Cardiovasc Revasc Med ; 24: 48-54, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32981855

RESUMO

INTRODUCTION: A volumetric approach to measure stent expansion derived from optical coherence tomography (OCT) is superior in regards to clinical outcomes when compared to the conventional method. The current software already performs a semi-automatic assessment and it is available as a clinical tool, however data is still scarce. We evaluated the stent expansion analysis that uses a volumetric vessel model, called minimum expansion index - MEI and compared to the conventional model, which utilizes the minimum stent area expansion (MSAx) indexed to the references, and its potential impact on procedural decision-making strategy in percutaneous coronary intervention. METHODS: This was a prospective, all-comers single center study, from all patients undergoing OCT-guided PCI between September 2018 and May 2019. We utilized the APTIVUE™ OPTIS 5.2 software (Abbott, Santa Clara, CA) to evaluate MEI and MSAx measurements after reference adjustments. RESULTS: We included 100 patients with mean age of 64 ± 12.5 years, 68% were men, and the main arteries analyzed through OCT were LAD (48%), RCA (31%) and LCx (21%). The mean MEI was 77.6% ± 16.7% and the mean MSAx was 71.6% ± 16.9%. MEI location differed from MSAx in 70% of cases, and in those cases the mean distance between MEI and MSAx was 15.3 mm ± 12.4 mm. In 53% of the times, the stent underexpansion based on MEI was located proximally to the MSAx by 18.1 mm ± 11.8 mm. Furthermore, in 42% of the total cases, MEI would change the intervention strategy based on the stent underexpansion being in a different location ≥10 mm in comparison to MSAx (34%) associated with the discrepancy between expansion indexes for MEI and MSAx (22%). CONCLUSION: We concluded that MEI location did not correlate to the conventional MSAx in two thirds of the cases. Moreover, compared to MEI, the MSAx assessment yielded lower expansion values in different stent positions, potentially changing the appropriate post-stent optimization, which thus would impact the decision-making strategy in almost half of the patients.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Stents , Tomografia de Coerência Óptica , Resultado do Tratamento
2.
JACC Case Rep ; 1(5): 811-814, 2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-34316937

RESUMO

We describe a complex percutaneous coronary intervention using rotational atherectomy (Rotablator, Boston Scientific, Marlborough, Massachusetts) and mechanical circulatory support (Impella, Abiomed, Danvers, Massachusetts) in a patient with multiple comorbidities scheduled to undergo a left main coronary percutaneous coronary intervention using a 2-stent technique based on angiography. However, intracoronary optical coherence tomography changed our strategy to a successful single-stent procedure. (Level of Difficulty: Advanced.).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA