J Am Coll Cardiol ; 13(3): 689-95, 1989 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-2521873

RESUMO

Balloon angioplasty for coarctation of the aorta was performed in 45 patients; 17 (Group 1) were infants (mean age 34 +/- 43 days). This study focuses on the remaining 28 patients (Group 2), children and adults ranging in age from 2 to 31 years (mean 13 +/- 8). Two patients had had previous surgery for coarctation; in the remaining 26 the coarctation had not been surgically treated. Twenty patients (71%) had a discrete type of coarctation; the remaining eight had a diffuse or eccentric stenosis. Angiographic studies of the aorta were performed before and immediately after angioplasty in all 28 patients; 16 (57%) of them also underwent angiographic reevaluation 10 +/- 2 months later. The pressure gradient decreased immediately after angioplasty and was unchanged at follow-up. Residual gradient at follow-up ranged from 0 to 40 mm Hg (mean 11 +/- 13). Patients with a discrete type of coarctation had a lesser residual gradient than did patients with other anatomic types of coarctation. Angiographically, the stenosis also decreased after angioplasty (68 +/- 10% versus 24 +/- 17%; p less than 0.01); a new small, but significant decrease was observed at follow-up (9 +/- 18%; p less than 0.05). A quantitative analysis of the aorta at different levels revealed no significant changes proximal and distal to the coarctation segment; however, at the level of coarctation, a significant (p less than 0.01) and homogeneous increment was observed after dilation that was unchanged at follow-up. One (6%) of 16 reevaluated patients had a clear aneurysm at the site of dilation.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Angioplastia com Balão , Coartação Aórtica/terapia , Aortografia , Adolescente , Adulto , Angioplastia com Balão/efeitos adversos , Coartação Aórtica/diagnóstico por imagem , Pressão Sanguínea , Criança , Pré-Escolar , Seguimentos , Humanos , Pressão
2.
J Am Coll Cardiol ; 36(2): 583-92, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10933375

RESUMO

OBJECTIVES: The purpose of this study was to assess safety and effectiveness of the fourth generation buttoned device in dosing atrial septal defects (ASDs) and to test the hypothesis that introduction of double button reduces unbuttoning rate without reducing effectiveness. BACKGROUND: Because of the high unbuttoning rate (7.2%) with first, second and third generation buttoned devices, the device was modified (fourth generation) so that there were two radiopaque spring buttons 4 mm apart on the button loop attached to the occluder. METHODS: During a four-year period ending in September 1997, 423 patients, ages 1.5 to 80 years (median 16 years), underwent closure of ASD at 40 medical centers around the world. RESULTS: The ASD size varied between 5 and 30 mm (median 17 mm). The device size varied between 25 and 60 mm. Unbuttoning occurred in 4 (0.9%) of 423 patients. Effective occlusion, defined as no (n = 343) or trivial (n = 34) residual shunt on echo-Doppler studies performed within 24 h of the procedure, was demonstrated in 377 patients (90%). Thus, the unbuttoning rate (0.9 vs. 7.2%) decreased (p<0.01) while effective occlusion rate (90 vs. 92%) remained unchanged (p>0.1) with this device, compared with earlier generation devices. During follow-up from one month to five years (23+/-15 months), 21 (5%) of 417 patients required surgical (n = 12) or transcatheter (n = 9) reintervention, mostly to treat significant residual shunt. In the remaining patients there was gradual reduction and disappearance of the residual shunt. No wire integrity problems were observed. CONCLUSIONS: These data suggest that the fourth generation buttoned device is as effective as earlier generation devices, but without significant unbuttoning. Follow-up results remained good, with a reintervention-free rate of 89% at five years.


Assuntos
Cateterismo Cardíaco , Comunicação Interatrial/cirurgia , Próteses e Implantes , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Humanos , Lactente , Pessoa de Meia-Idade , Desenho de Prótese , Implantação de Prótese , Estudos Retrospectivos
3.
Tex Heart Inst J ; 27(2): 216-7, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10928513

RESUMO

Severe pulmonary stenosis in association with a large atrial septal defect is uncommon. When these 2 conditions are present, significant left-to-right shunt is often prevented by the outflow obstruction, which protects the pulmonary bed until adulthood. This report shows our initial experience of percutaneous treatment of both congenital malformations, either staged or combined in the same procedure, in 2 adult patients whose treatments yielded effective atrial septal defect occlusion and right ventricular pressure relief that persisted at mid-term follow-up. Although these opposite procedures (opening and closing) have been applied as isolated methods of treatment, this preliminary experience appears to demonstrate the feasibility and effectiveness of a combined percutaneous treatment.


Assuntos
Cateterismo , Embolização Terapêutica , Comunicação Interatrial/terapia , Estenose da Valva Pulmonar/terapia , Adulto , Estudos de Viabilidade , Feminino , Comunicação Interatrial/complicações , Humanos , Pessoa de Meia-Idade , Estenose da Valva Pulmonar/complicações
4.
Tex Heart Inst J ; 10(3): 293-9, 1983 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15227114

RESUMO

The clinical, hemodynamic and angiographic features of a patient with situs inversus, atrioventricular discordance, corrected transposition of the great arteries (I,D,D) and mesocardia are presented. A review of the literature concerning corrected transposition of the great arteries in situs inversus is included. The incidence of associated cardiovascular and electrocardiographic anomalies is compared with that found in corrected transposition of the great arteries in situs solitus; special surgical aspects of the above cases are also discussed.

6.
Am Heart J ; 133(2): 210-20, 1997 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9023168

RESUMO

This study was undertaken to characterize, by intracoronary ultrasound technique, the neointimal thickening at follow-up of treated coronary segments after successful arterial wall repair and to compare the findings with serial angiographic studies. We selected for study 81 patients with single-vessel coronary disease successfully treated by percutaneous revascularization who were angiographically and ultrasonically reevaluated at a mean follow-up time of 22 +/- 21 months; 23 had been treated by balloon angioplasty, 27 by directional atherectomy, and 31 by elective Palmaz-Schatz stent implantation. The late maximal neointimal thickness varied between 0.1 and 1.5 mm (mean 0.65 +/- 0.31 mm), and the neointimal area ranged between 0.97 and 14.9 mm2 (mean 5.19 +/- 3.14 mm2). The neointimal repair was thinner in patients who obtained a better acute angiographic result immediately after treatment and in stented (3.4 +/- 1.8 mm2) versus dilated (7.8 +/- 4.1 mm2) or resected (5 +/- 1.6 mm2, p < 0.001) segments. On the contrary, the repaired neointimal layer was thicker in those patients who angiographically exhibited less late luminal loss or even expansion and in those evaluated after a longer time since treatment. The acute gain and the time influence resulted in independent predictors of the degree of neointimal thickness. These findings suggest that two reparative mechanisms of the coronary wall may operate in close relation.


Assuntos
Angioplastia Coronária com Balão , Aterectomia Coronária , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Angioplastia Coronária com Balão/estatística & dados numéricos , Aterectomia Coronária/estatística & dados numéricos , Angiografia Coronária/métodos , Angiografia Coronária/estatística & dados numéricos , Doença das Coronárias/terapia , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva , Estudos Retrospectivos , Stents/estatística & dados numéricos , Ultrassonografia de Intervenção/métodos , Ultrassonografia de Intervenção/estatística & dados numéricos