Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Diabet Med ; 41(2): e15243, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37845186

RESUMO

AIMS: The impact of maternal metformin use during pregnancy on fetal, infant, childhood and adolescent growth, development, and health remains unclear. Our objective was to systematically review the available evidence from animal experiments on the effects of intrauterine metformin exposure on offspring's anthropometric, cardiovascular and metabolic outcomes. METHODS: A systematic search was conducted in PUBMED and EMBASE from inception (searched on 12th April 2023). We extracted original, controlled animal studies that investigated the effects of maternal metformin use during pregnancy on offspring anthropometric, cardiovascular and metabolic measurements. Subsequently, risk of bias was assessed and meta-analyses using the standardized mean difference and a random effects model were conducted for all outcomes containing data from 3 or more studies. Subgroup analyses were planned for species, strain, sex and type of model in the case of 10 comparisons or more per subgroup. RESULTS: We included 37 articles (n = 3133 offspring from n = 716 litters, containing n = 51 comparisons) in this review, mostly (95%) on rodent models and 5% pig models. Follow-up of offspring ranged from birth to 2 years of age. Thirty four of the included articles could be included in the meta-analysis. No significant effects in the overall meta-analysis of metformin on any of the anthropometric, cardiovascular and metabolic offspring outcome measures were identified. Between-studies heterogeneity was high, and risk of bias was unclear in most studies as a consequence of poor reporting of essential methodological details. CONCLUSION: This systematic review was unable to establish effects of metformin treatment during pregnancy on anthropometric, cardiovascular and metabolic outcomes in non-human offspring. Heterogeneity between studies was high and reporting of methodological details often limited. This highlights a need for additional high-quality research both in humans and model systems to allow firm conclusions to be established. Future research should include focus on the effects of metformin in older offspring age groups, and on outcomes which have gone uninvestigated to date.


Assuntos
Diabetes Mellitus , Metformina , Gravidez , Animais , Feminino , Humanos , Gravidez/efeitos dos fármacos , Experimentação Animal , Antropometria , Hipoglicemiantes/efeitos adversos , Metformina/efeitos adversos , Cuidado Pré-Natal , Suínos , Camundongos , Ratos , Modelos Animais , Diabetes Mellitus/tratamento farmacológico
2.
Diabet Med ; 38(4): e14406, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32961611

RESUMO

AIM: To describe the prevalence and characteristics of polypharmacy in a Dutch cohort of individuals with type 2 diabetes. METHODS: We included people with type 2 diabetes from the Diabetes Pearl cohort, of whom 3886 were treated in primary care and 2873 in academic care (secondary/tertiary). With multivariable multinomial logistic regression analyses stratified for line of care, we assessed which sociodemographic, lifestyle and cardiometabolic characteristics were associated with moderate (5-9 medications) and severe polypharmacy (≥10 medications) compared with no polypharmacy (0-4 medications). RESULTS: Mean age was 63 ± 10 years, and 40% were women. The median number of daily medications was 5 (IQR 3-7) in primary care and 7 (IQR 5-10) in academic care. The prevalence of moderate and severe polypharmacy was 44% and 10% in primary care, and 53% and 29% in academic care respectively. Glucose-lowering and lipid-modifying medications were most prevalent. People with severe polypharmacy used a relatively large amount of other (i.e. non-cardiovascular and non-glucose-lowering) medication. Moderate and severe polypharmacy across all lines of care were associated with higher age, low educational level, more smoking, longer diabetes duration, higher BMI and more cardiovascular disease. CONCLUSIONS: Severe and moderate polypharmacy are prevalent in over half of people with type 2 diabetes in primary care, and even more in academic care. People with polypharmacy are characterized by poorer cardiometabolic status. These results highlight the significance of polypharmacy in type 2 diabetes.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Polimedicação , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/tratamento farmacológico , Doenças Cardiovasculares/epidemiologia , Estudos de Coortes , Comorbidade , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Polimedicação/estatística & dados numéricos , Prevalência , Fatores Socioeconômicos
3.
Anaesthesia ; 74(7): 929-939, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30821852

RESUMO

In the peri-operative period, dexamethasone is widely and effectively used for prophylaxis of postoperative nausea and vomiting. The objective of this meta-analysis was to assess the adverse effects of an incidental steroid load of dexamethasone in adult surgical patients. We searched in MEDLINE, Embase, the Cochrane Central Register of Controlled Trials and the Web of Science for randomised controlled trials comparing an incidental steroid load of dexamethasone with a control intervention in adult patients undergoing surgery. Two review authors independently screened studies for eligibility, extracted data and assessed all included studies for bias. Our primary outcomes were postoperative systemic or wound infection, delayed wound healing and glycaemic response within 24 h. We included 37 studies in this meta-analysis. The pooled results found no evidence that dexamethasone increased the risk of a postoperative wound infection, Peto OR (95%CI) 1.01 (0.80-1.27); 4603 participants, 26 studies; I² = 32%; moderate-quality evidence. Whether dexamethasone influenced wound healing was unclear due to the large confidence intervals, Peto OR (95%CI) 0.99 (0.28-3.43); 1072 participants, 8 studies; I² = 0%; low-quality evidence. Dexamethasone produced a mild increase in glucose levels among participants without diabetes during the first 12 h after surgery, mean difference (95%CI) 0.7 mmol.l-1 (0.3-1.2) 10 studies; 595 participants; I² = 50%; low-quality evidence. This article is an abridged version of a Cochrane Review.


Assuntos
Dexametasona/efeitos adversos , Glucocorticoides/efeitos adversos , Complicações Pós-Operatórias/induzido quimicamente , Humanos
4.
Diabetes Obes Metab ; 20(3): 749-752, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28940961

RESUMO

Historically, metformin was withheld before surgery for fear of metformin-associated lactic acidosis. Currently, however, this risk is deemed to be low and guidelines have moved towards the continuation of metformin. We hypothesized that continuing metformin peri-operatively would lower postoperative serum glucose level without an effect on plasma lactate levels. We performed a single-blind multicentre randomized controlled trial in people with type 2 diabetes mellitus scheduled for non-cardiac surgery and continued (MF+ group) or withheld (MF- group) metformin before surgery. The main outcome measures were the differences in peri-operative plasma glucose and lactate levels. We randomized 70 patients (37 MF+ group and 33 MF- group) with type 2 diabetes mellitus. Postoperative glucose levels were similar in the MF+ and the MF- groups (8.2 ± 1.8 vs 8.3 ± 2.3 mmol/L P = .95) Although preoperative lactate levels were slightly higher in the MF+ group compared with the MF- group (1.5 vs 1.2 mmol/L; P = .02), the postoperative lactate levels were not significantly different (1.2 vs 1.0 mmol/L; P = .18). In conclusion, continuation of metformin during elective non-cardiac surgery does not improve glucose control or raise lactate levels to a clinically relevant degree.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Metformina/uso terapêutico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Glicemia/metabolismo , Diabetes Mellitus Tipo 2/sangue , Feminino , Humanos , Cuidados Intraoperatórios , Tempo de Internação/estatística & dados numéricos , Masculino , Adesão à Medicação , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Método Simples-Cego , Resultado do Tratamento , Adulto Jovem
5.
Oecologia ; 187(1): 305-318, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29627956

RESUMO

According to theory, habitat selection by organisms should reflect underlying habitat-specific fitness consequences and, in birds, reproductive success has a strong impact on population growth in many species. Understanding processes affecting habitat selection also is critically important for guiding conservation initiatives. Northern pintails (Anas acuta) are migratory, temperate-nesting birds that breed in greatest concentrations in the prairies of North America and their population remains below conservation goals. Habitat loss and changing land use practices may have decoupled formerly reliable fitness cues with respect to nest habitat choices. We used data from 62 waterfowl nesting study sites across prairie Canada (1997-2009) to examine nest survival, a primary fitness metric, at multiple scales, in combination with estimates of habitat selection (i.e., nests versus random points), to test for evidence of adaptive habitat choices. We used the same habitat covariates in both analyses. Pintail nest survival varied with nest initiation date, nest habitat, pintail breeding pair density, landscape composition and annual moisture. Selection of nesting habitat reflected patterns in nest survival in some cases, indicating adaptive selection, but strength of habitat selection varied seasonally and depended on population density and landscape composition. Adaptive selection was most evident late in the breeding season, at low breeding densities and in cropland-dominated landscapes. Strikingly, at high breeding density, habitat choice appears to become maladaptive relative to nest predation. At larger spatial scales, the relative availability of habitats with low versus high nest survival, and changing land use practices, may limit the reproductive potential of pintails.


Assuntos
Ecossistema , Comportamento de Nidação , Animais , Aves , Canadá , América do Norte
6.
Anaesthesia ; 73(3): 332-339, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29230803

RESUMO

In this open-label multicentre randomised controlled trial, we investigated three peri-operative treatment strategies to lower glucose and reduce the need for rescue insulin in patients aged 18-75 years with type-2 diabetes mellitus undergoing non-cardiac surgery. Patients were randomly allocated using a web-based randomisation program to premedication with liraglutide (liraglutide group), glucose-insulin-potassium infusion (insulin infusion group) or insulin bolus regimen (insulin bolus group), targeting a glucose < 8.0 mmol.l-1 . The primary outcome was the between group difference in median glucose levels 1 h after surgery. We analysed 150 patients (liraglutide group n = 44, insulin infusion group n = 53, insulin bolus group n = 53) according to the intention-to-treat principle. Median (IQR [range]) plasma glucose 1 h postoperatively was lower in the liraglutide group compared with the insulin infusion and insulin bolus groups (6.6 (5.6-7.7 [4.2-13.5]) mmol.l-1 vs. 7.5 (6.4-8.3 [3.9-16.6]) mmol.l-1 (p = 0.026) and 7.6 (6.4-8.9 [4.7-13.2]) mmol.l-1 ) p = 0.006, respectively). The incidence of hypoglycaemia and postoperative complications did not differ between the groups. Six patients had pre-operative nausea in the liraglutide group, of which two had severe nausea, compared with no patients in the insulin infusion and insulin bolus groups (p = 0.007). The pre-operative administration of liraglutide stabilised peri-operative plasma glucose levels and reduced peri-operative insulin requirements, at the expense of increased pre-operative nausea rates.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Liraglutida/uso terapêutico , Assistência Perioperatória , Idoso , Glicemia/análise , Diabetes Mellitus Tipo 2/sangue , Feminino , Glucose/uso terapêutico , Humanos , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Potássio/uso terapêutico
7.
J Clin Monit Comput ; 32(5): 953-964, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29218549

RESUMO

Subcutaneous continuous glucose monitoring (CGM) may have benefits in achieving glycemic control in critically ill patients. The aim of this study was to assess the accuracy and reliability of the FreeStyle Navigator I in critically ill patients and to assess patient related factors influencing the accuracy and reliability. This study is a retrospective analysis of data from a randomized controlled trial conducted in a 20-bed mixed intensive care unit. Analytical accuracy, clinical accuracy and reliability were assessed against arterial blood glucose samples as reference. Assessment was according to recent consensus recommendations with median absolute relative difference (median ARD), Bland-Altman plots, the ISO system accuracy standards (ISO 15197:2013) and Clarke error grid analysis (CEG). We analyzed 2840 paired measurements from 155 critically ill patients. The median ARD of all paired values was 13.3 [6.9-22.1]%. The median ARD was significantly higher in both the hypoglycemic and the hyperglycemic range (32.4 [12.1-53.4]% and 18.7 [10.7-28.3]% respectively, p < 0.001). The Bland-Altman analysis showed a mean bias of - 0.82 mmol/L with a lower limit of agreement (LOA) of - 3.88 mmol/L and an upper LOA of 2.24 mmol/L. A total of 1626 (57.3%) values met the ISO-2013, standards and 1,334 (47%) CGM values were within 12.5% from the reference value. CEG: 71.0% zone A, 25.8% zone B, 0.5% zone C, 2.5% zone D, 0.3% zone E. The median overall real-time data display time was 94.0 ± 14.9% and in 23% of the patients, the sensor measured < 95% of the time. Additionally, data gaps longer than 30 min were found in 48% of the patients. The analytical accuracy of the FreeStyle Navigator I in critically ill patients was suboptimal. Furthermore, the clinical accuracy, did not meet the required standards. The reliability was satisfactory, however, in almost a quarter of the patients the realtime data display was < 95%. The accuracy was considerably and significantly lower in hyper- and hypoglycemic ranges.


Assuntos
Glicemia/análise , Monitorização Fisiológica/instrumentação , Idoso , Estado Terminal/enfermagem , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/enfermagem , Monitorização Fisiológica/estatística & dados numéricos , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
Diabet Med ; 34(2): 262-271, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27696520

RESUMO

AIM: To assess the impact on fear of hypoglycaemia and treatment satisfaction with an artificial pancreas system used for 2 consecutive months, as well as participant acceptance of the artificial pancreas system. METHODS: In a randomized crossover trial patient-related outcomes associated with an evening-and-night artificial pancreas and sensor-augmented pump therapy were compared. Both intervention periods lasted 8 weeks. The artificial pancreas acceptance questionnaire (range 0-90, higher scores better), Hypoglycaemia Fear Survey II (range 0-72, higher scores worse) and Diabetes Treatment Satisfaction Questionnaire (range 0-36, higher scores better) were completed by 32 participants. Semi-structured interviews were conducted after study completion in a subset of six participants. Outcomes were compared using a repeated-measures anova model or paired t-test when appropriate. RESULTS: The total artificial pancreas acceptance questionnaire score at the end of the artificial pancreas period was 69.1 (sd 14.7; 95% CI 63.5, 74.7), indicating a positive attitude towards the artificial pancreas. No significant differences were found among the scores at baseline, end of sensor-augmented pump therapy period or end of the artificial pancreas period with regard to fear of hypoglycaemia [28.2 (sd 17.5), 23.5 (sd 16.6) and 23.5 (sd 16.7), respectively; P = 0.099] or diabetes treatment satisfaction [29.0 (sd 3.9), 28.2 (sd 5.2) and 28.0 (sd 7.1), respectively; P = 0.43]. Themes frequently mentioned in the interviews were 'positive effects at work', 'improved blood glucose', 'fewer worries about blood glucose', but also 'frequent alarms', 'technological issues' and 'demand for an all-in-one device'. CONCLUSIONS: The psychological outcomes of artificial pancreas and sensor-augmented pump therapy were similar. Current artificial pancreas technology is promising but user concerns should be taken into account to ensure utility of these systems.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Medo/psicologia , Hipoglicemia/psicologia , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pâncreas Artificial , Satisfação do Paciente , Adulto , Glicemia/metabolismo , Estudos Cross-Over , Diabetes Mellitus Tipo 1/metabolismo , Feminino , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários
9.
Diabet Med ; 34(11): 1623-1628, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28703888

RESUMO

AIMS: Individual indicators of socio-economic status have been associated with glycaemic control in people with Type 2 diabetes, but little is known about the association between partner's socio-economic status and HbA1c levels. We therefore examined the cross-sectional association between individual and partner's level of occupation on HbA1c levels in people with Type 2 diabetes in the Netherlands. METHODS: We included people with Type 2 diabetes with a partner who were treated in primary, secondary and tertiary care in the Diabetes Pearl cohort. Occupational level was classified according to International Standard Classification of Occupations (ISCO)-08 skill levels. Linear regression analyses were performed stratified for sex, and corrected for age, recruitment centre and diabetes medication. RESULTS: In total, 3257 participants (59.8% men, mean 62.2±9.4 years) were included. For men, having a partner with an intermediate level of occupation was associated with lower HbA1c levels [e.g. ISCO level 3: -2 mmol/mol (95% CI -4;-1) or -0.2% (95% CI -0.4;-0.1)], compared with having a partner of the highest occupational level (ISCO level 4). In women, having an unemployed partner was associated with higher HbA1c levels [14 mmol/mol (95% CI 6; 22) or 1.3% (95% CI 0.6; 2.0)], compared with having a partner of the highest occupational level. CONCLUSIONS: Partner's occupational status provided additional information on the association between socio-economic status and HbA1c levels in people with Type 2 diabetes. Women seemed to benefit from a partner with a higher occupational status, while men seemed to benefit from a partner with a lower status. Because of the cross-sectional nature of the present study, more research is necessary to explore this association.


Assuntos
Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/epidemiologia , Hemoglobinas Glicadas/análise , Ocupações , Cônjuges , Adulto , Idoso , Idoso de 80 Anos ou mais , Glicemia/análise , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Ocupações/estatística & dados numéricos , Classe Social , Apoio Social , Cônjuges/estatística & dados numéricos , Adulto Jovem
10.
Diabetes Obes Metab ; 18(1): 34-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26343550

RESUMO

AIMS: To evaluate the pharmacokinetics and pharmacodynamics of different doses of glucagon administered subcutaneously (s.c.) at different blood glucose levels. METHODS: This study was an open-label, randomized, three-period, cross-over experiment in 6 patients with type 1 diabetes. During each of the three periods, different blood glucose levels were established in four consecutive steps (8, 6, 4 and 2.8 mmol/l) and glucagon was given at each blood glucose level in doses from 0.11 to 0.44 mg and 0.33, 0.66 and 1 mg at the lowest glucose concentration. RESULTS: Maximum glucagon concentration and area under the curve increased with increasing glucagon dose. Maximum glucagon concentration was reached after 10-20 min. Glucagon raised blood glucose in a dose-dependent manner at different baseline blood glucose levels. The median glucose excursion ranged from 2.6 to 6.2 mmol/l. Time to maximum glucose concentration was dose-dependent for the glucagon doses at 2.8 mmol/l, with median values from 40 to 80 min. CONCLUSIONS: Glucagon administered s.c. produces a stable pharmacokinetic and pharmacodynamic response at lower doses than the usual rescue dose and across a range of hypo- to hyperglycaemic blood glucose levels. This supports the use of small glucagon doses in the artificial pancreas to correct and prevent hypoglycaemia.


Assuntos
Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucagon/farmacocinética , Hipoglicemiantes/farmacocinética , Adulto , Glicemia/análise , Estudos Cross-Over , Relação Dose-Resposta a Droga , Feminino , Fármacos Gastrointestinais/administração & dosagem , Fármacos Gastrointestinais/farmacocinética , Glucagon/administração & dosagem , Técnica Clamp de Glucose , Humanos , Hipoglicemiantes/administração & dosagem , Masculino , Pessoa de Meia-Idade
11.
Diabetes Obes Metab ; 18(7): 671-7, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26996542

RESUMO

AIMS: To assess the performance and safety of an integrated bihormonal artificial pancreas system consisting of one wearable device and two wireless glucose sensor transmitters during short-term daily use at home. METHODS: Adult patients with type 1 diabetes using an insulin pump were invited to enrol in this randomized crossover study. Treatment with the artificial pancreas started with a day and night in the clinical research centre, followed by 3 days at home. The control period consisted of 4 days of insulin pump therapy at home with blinded continuous glucose monitoring for data collection. Days 2-4 were predefined as the analysis period, with median glucose as the primary outcome. RESULTS: A total of 10 patients completed the study. The median [interquartile range (IQR)] glucose level was similar for the two treatments [7.3 (7.0-7.6) mmol/l for the artificial pancreas vs. 7.7 (7.0-9.0) mmol/l for the control; p = 0.123]. The median (IQR) percentage of time spent in euglycaemia (3.9-10 mmol/l) was longer during use of the artificial pancreas [84.7 (82.2-87.8)% for the artificial pancreas vs. 68.5 (57.9-83.6)% for the control; p = 0.007]. Time in hypoglycaemia was 1.3 (0.2-3.2)% for the artificial pancreas and 2.4 (0.4-10.3)% for the control treatment (p = 0.139). Separate analysis of daytime and night-time showed that the improvements were mainly achieved during the night. CONCLUSIONS: The results of this pilot study suggest that our integrated artificial pancreas provides better glucose control than insulin pump therapy in patients with type 1 diabetes at home and that the treatment is safe.


Assuntos
Diabetes Mellitus Tipo 1/terapia , Pâncreas Artificial , Adolescente , Adulto , Idoso , Glicemia/metabolismo , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Feminino , Glucagon/administração & dosagem , Glucagon/efeitos adversos , Serviços de Assistência Domiciliar , Humanos , Hiperglicemia/induzido quimicamente , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Sistemas de Infusão de Insulina , Insulinas/administração & dosagem , Insulinas/efeitos adversos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Resultado do Tratamento , Adulto Jovem
12.
Diabetes Obes Metab ; 17(5): 445-51, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25376600

RESUMO

Biosimilar insulins are likely to enter clinical practice in Europe in the near future. It is important that clinicians are familiar with and understand the concept of biosimilarity and how a biosimilar drug may differ from its reference product. The present article provides an overview of biosimilars, the European regulatory requirements for biosimilars and safety issues. It also summarizes the current biosimilars approved in Europe and the key clinical issues associated with the use of biosimilar insulins.


Assuntos
Medicamentos Biossimilares/normas , Insulinas/normas , Medicamentos Biossimilares/uso terapêutico , Medicamentos Genéricos/normas , Europa (Continente) , Humanos , Insulinas/uso terapêutico , Legislação de Medicamentos
13.
Diabetes Obes Metab ; 17(4): 343-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25132320

RESUMO

AIMS: To assess the accuracy and reliability of the two most widely used continuous glucose monitoring (CGM) systems. METHODS: We studied the Dexcom®G4 Platinum (DG4P; Dexcom, San Diego, CA, USA) and Medtronic Paradigm Veo Enlite system (ENL; Medtronic, Northridge, CA, USA) CGM systems, in 24 patients with type 1 diabetes. The CGM systems were tested during 6-day home use and a nested 6-h clinical research centre (CRC) visit. During the CRC visit, frequent venous blood glucose samples were used as reference while patients received a meal with an increased insulin bolus to induce an aggravated postprandial glucose nadir. At home, patients performed at least six reference capillary blood measurements per day. A Wilcoxon signed-rank test was performed using all data points ≥15 min apart. RESULTS: The overall mean absolute relative difference (MARD) value [standard deviation (s.d.)] measured at the CRC was 13.6 (11.0)% for the DG4P and 16.6 (13.5)% for the ENL [p < 0.0002, confidence interval of difference (CI Δ) 1.7-4.3%, n = 530]. The overall MARD assessed at home was 12.2 (12.0)% for the DG4P and 19.9 (20.5)% for the ENL (p < 0.0001, CI Δ = 5.8-8.7%, n = 839). During the CRC visit, the MARD in the hypoglycaemic range [≤3.9 mmol/l (70 mg/dl)], was 17.6 (12.2)% for the DG4P and 24.6 (18.8)% for the ENL (p = 0.005, CI Δ 3.1-10.7%, n = 117). Both sensors showed higher MARD values during hypoglycaemia than during euglycaemia [3.9-10 mmol/l (70-180 mg/dl)]: for the DG4P 17.6 versus 13.0% and for the ENL 24.6 versus 14.2%. CONCLUSIONS: During circumstances of intended use, including both a CRC and home phase, the ENL was noticeably less accurate than the DG4P sensor. Both sensors showed lower accuracy in the hypoglycaemic range. The DG4P was less affected by this negative effect of hypoglycaemia on sensor accuracy than was the ENL.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Hiperglicemia/diagnóstico , Hipoglicemia/diagnóstico , Monitorização Ambulatorial/instrumentação , Atividades Cotidianas , Adulto , Áustria , Pesquisa Biomédica/instrumentação , Diabetes Mellitus Tipo 1/tratamento farmacológico , Feminino , França , Humanos , Hiperglicemia/prevenção & controle , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Injeções Subcutâneas , Insulina/administração & dosagem , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Itália , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Países Baixos , Reprodutibilidade dos Testes
14.
Diabetes Obes Metab ; 17(5): 468-76, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25600304

RESUMO

AIMS: To test in an outpatient setting the safety and efficacy of continuous subcutaneous insulin infusion (CSII) driven by a modular model predictive control (MMPC) algorithm informed by continuous glucose monitoring (CGM) measurement. METHODS: 13 patients affected by type 1 diabetes participated to a non-randomized outpatient 42-h experiment that included two evening meals and overnight periods (in short, dinner & night periods). CSII was patient-driven during dinner & night period 1 and MMPC-driven during dinner&night period 2. The study was conducted in hotels, where patients could move around freely. A CGM system (G4 Platinum; Dexcom Inc., San Diego, CA, USA) and insulin pump (AccuChek Combo; Roche Diagnostics, Mannheim, Germany) were connected wirelessly to a smartphone-based platform (DiAs, Diabetes Assistant; University of Virginia, Charlottesville, VA, USA) during both periods. RESULTS: A significantly lower percentage of time spent with glucose levels <3.9 mmol/l was achieved in period 2 compared with period 1: 1.96 ± 4.56% vs 12.76 ± 15.84% (mean ± standard deviation, p < 0.01), together with a greater percentage of time spent in the 3.9-10 mmol/l target range: 83.56 ± 14.02% vs 62.43 ± 29.03% (p = 0.04). In addition, restricting the analysis to the overnight phases, a lower percentage of time spent with glucose levels <3.9 mmol/l (1.92 ± 4.89% vs 12.7 ± 19.75%; p = 0.03) was combined with a greater percentage of time spent in 3.9-10 mmol/l target range in period 2 compared with period 1 (92.16 ± 8.03% vs 63.97 ± 2.73%; p = 0.01). Average glucose levels were similar during both periods. CONCLUSIONS: The results suggest that MMPC managed by a wearable system is safe and effective during evening meal and overnight. Its sustained use during this period is currently being tested in an ongoing randomized 2-month study.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pâncreas Artificial , Adulto , Idoso , Algoritmos , Assistência Ambulatorial , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 1/sangue , Cronofarmacoterapia , Feminino , Humanos , Hipoglicemia/sangue , Masculino , Refeições , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
15.
Diabet Med ; 31(2): 122-5, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24152416

RESUMO

Evidence for continuous glucose monitoring is mounting. Meta-analyses consistently show lowering of HbA1c , and the first trial reporting a reduction in severe hypoglycaemic events in patients with hypoglycaemia unawareness has recently been presented. The more recent trials studied larger numbers of patients and may have shown better results because of improved technology. The various combinations of pump and sensor, with automated bolus calculators and low glucose suspend features, make evaluation more challenging from a reimbursement point of view, but evidence seems convincing enough to justify reimbursement for selected patient groups, including those who have shown a substantial improvement in HbA1c during a trial period, and those with hypoglycaemia unawareness who encountered severe hypoglycaemia in the recent past. More data on cost-efficacy are needed.


Assuntos
Diabetes Mellitus/sangue , Diabetes Mellitus/economia , Reembolso de Seguro de Saúde , Automonitorização da Glicemia/economia , Automonitorização da Glicemia/métodos , Análise Custo-Benefício , Diabetes Mellitus/tratamento farmacológico , Prática Clínica Baseada em Evidências , Humanos , Insulina/administração & dosagem , Insulina/economia , Sistemas de Infusão de Insulina/economia
17.
Eur J Obstet Gynecol Reprod Biol ; 296: 371-375, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38552506

RESUMO

OBJECTIVE: The WHO 2013 guidelines recommend screening for gestational diabetes mellitus (GDM) by 3-point oral glucose tolerance test (OGTT). The objective of this retrospective cohort study was to evaluate GDM diagnosed by an isolated high glucose. STUDY DESIGN: We included pregnant women deemed at risk for GDM were offered GDM screening. We examined the records of 1939 consecutively screened pregnancies at two teaching hospitals in Amsterdam during 2016-2020. Using the WHO 2013 diagnostic criteria, we calculated the proportion of GDM cases diagnosed by isolated abnormal glucose values. RESULTS: Among those screened in our high risk cohort, GDM incidence was 31.5%. Of the GDM diagnoses, 57.0% were based on an isolated fasting glucose value, 30.9% based on multiple raised glucose measurements, 7.4% on an isolated raised 2-hour glucose and 4.7% on an isolated raised 1-hour glucose. For 1-hour glucose, the number needed to screen was 67 persons for one additional GDM case. CONCLUSION: The 1-hour glucose in the 3 point OGTT, as suggested by the WHO 2013 guidelines for GDM, contributes only small numbers of GDM cases and a high number needed to screen (67 for 1 additional case in a selective high risk GDM screening strategy), and is likely even less effective in universally screened populations.


Assuntos
Glicemia , Diabetes Gestacional , Gravidez , Feminino , Humanos , Teste de Tolerância a Glucose , Estudos Retrospectivos , Diabetes Gestacional/epidemiologia , Organização Mundial da Saúde
18.
Lancet Digit Health ; 6(4): e272-e280, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38443309

RESUMO

BACKGROUND: Management of insulin administration for intake of carbohydrates and physical activity can be burdensome for people with type 1 diabetes on hybrid closed-loop systems. Bihormonal fully closed-loop (FCL) systems could help reduce this burden. In this trial, we assessed the long-term performance and safety of a bihormonal FCL system. METHODS: The FCL system (Inreda AP; Inreda Diabetic, Goor, Netherlands) that uses two hormones (insulin and glucagon) was assessed in a 1 year, multicentre, prospective, single-arm intervention trial in adults with type 1 diabetes. Participants were recruited in eight outpatient clinics in the Netherlands. We included adults with type 1 diabetes aged 18-75 years who had been using flash glucose monitoring or continuous glucose monitors for at least 3 months. Study visits were integrated into standard care, usually every three months, to evaluate glycaemic control, adverse events, and person-reported outcomes. The primary endpoint was time in range (TIR; glucose concentration 3·9-10·0 mmol/L) after 1 year. The study is registered in the Dutch Trial Register, NL9578. FINDINGS: Between June 1, 2021, and March 2, 2022, we screened 90 individuals and enrolled 82 participants; 78 were included in the analyses. 79 started the intervention and 71 were included in the 12 month analysis. Mean age was 47.7 (SD 12·4) years and 38 (49%) were female participants. The mean preintervention TIR of participants was 55·5% (SD 17·2). After 1 year of FCL treatment, mean TIR was 80·3% (SD 5·4) and median time below range was 1·36% (IQR 0·80-2·11). Questionnaire scores improved on Problem Areas in Diabetes (PAID) from 30·0 (IQR 18·8-41·3) preintervention to 10·0 (IQR 3·8-21·3; p<0·0001) at 12 months and on World Health Organization-Five Well-Being Index (WHO-5) from 60·0 (IQR 44·0-72·0) preintervention to 76·0 (IQR 60·0-80·0; p<0·0001) at 12 months. Five serious adverse events were reported (one cerebellar stroke, two severe hypoglycaemic, and two hyperglycaemic events). INTERPRETATION: Real-world data obtained in this trial demonstrate that use of the bihormonal FCL system was associated with good glycaemic control in patients who completed 1 year of treatment, and could help relieve these individuals with type 1 diabetes from making treatment decisions and the burden of carbohydrate counting. FUNDING: Inreda Diabetic.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Países Baixos , Estudos Prospectivos
19.
Diabet Med ; 30(5): 603-9, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23324032

RESUMO

AIMS: The Hypoglycemia Fear Survey (HFS)-II Behaviour and Worry subscales were developed to measure behaviours and anxiety related to hypoglycaemia in diabetes. However, previous studies found lower reliability in the HFS Behaviour subscale and inconsistent relationships with glucose control. The purpose of this study was to conduct extensive analyses of the internal structure of the HFS Behaviour subscale's internal structure and its relationships with diabetes outcomes, including HbA1c and episodes of severe hypoglycaemia. METHODS: HFS-II survey data from 1460 adults with Type 1 diabetes were collected from five countries. This aggregated sample underwent exploratory factor analysis and item analysis to determine the internal structure of the survey and subscales. RESULTS: A three-factor solution showed the best fit for the HFS, with two subscales emerging from the HFS Behaviour representing tendencies towards (1) maintenance of high blood glucose and (2) avoidance of hypoglycaemic risks by other behaviours, and a third single HFS Worry subscale. Subscale item analysis showed excellent fit, separation and good point-measure correlations. All subscales demonstrated acceptable (0.75) to excellent (0.94) internal reliability. HbA(1c) correlated with Maintain High Blood Glucose subscale scores, r = 0.14, P < 0.001, and severe hypoglycaemia frequency correlated with all subscales. CONCLUSIONS: The HFS Worry subscale measures one construct of anxiety about various aspects of hypoglycaemia. In contrast, the HFS Behaviour subscale appears to measure two distinct aspects of behavioural avoidance to prevent hypoglycaemia, actions which maintain high blood glucose and other behaviours to avoid hypoglycaemic risk. These results demonstrate the clinical importance of the HFS Behaviour subscales and their differential relationships with measures of diabetes outcome such as HbA1c .


Assuntos
Ansiedade , Medo , Hipoglicemia/psicologia , Hipoglicemiantes/efeitos adversos , Adulto , Ansiedade/epidemiologia , Ansiedade/psicologia , Automonitorização da Glicemia , Medo/psicologia , Feminino , Alemanha/epidemiologia , Hemoglobinas Glicadas/metabolismo , Humanos , Hipoglicemia/epidemiologia , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Cooperação do Paciente , Psicometria , Qualidade de Vida , Reprodutibilidade dos Testes , Autocuidado , Eslovênia/epidemiologia , Inquéritos e Questionários , Turquia/epidemiologia , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA