Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 307
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Circulation ; 149(2): e201-e216, 2024 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-38047353

RESUMO

The American Heart Association sponsored the first iteration of a scientific statement that addressed all aspects of cardiovascular implantable electronic device infection in 2010. Major advances in the prevention, diagnosis, and management of these infections have occurred since then, necessitating a scientific statement update. An 11-member writing group was identified and included recognized experts in cardiology and infectious diseases, with a career focus on cardiovascular infections. The group initially met in October 2022 to develop a scientific statement that was drafted with front-line clinicians in mind and focused on providing updated clinical information to enhance outcomes of patients with cardiovascular implantable electronic device infection. The current scientific statement highlights recent advances in prevention, diagnosis, and management, and how they may be incorporated in the complex care of patients with cardiovascular implantable electronic device infection.


Assuntos
Cardiologia , Infecções Cardiovasculares , Doenças Transmissíveis , Desfibriladores Implantáveis , Endocardite Bacteriana , Estados Unidos , Humanos , American Heart Association , Doenças Transmissíveis/diagnóstico , Doenças Transmissíveis/epidemiologia , Doenças Transmissíveis/terapia , Endocardite Bacteriana/tratamento farmacológico , Desfibriladores Implantáveis/efeitos adversos
2.
Circulation ; 149(5): 379-390, 2024 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-37950738

RESUMO

BACKGROUND: Left bundle branch area pacing (LBBAP) may be associated with greater improvement in left ventricular ejection fraction and reduction in death or heart failure hospitalization compared with biventricular pacing (BVP) in patients requiring cardiac resynchronization therapy. We sought to compare the occurrence of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) and new-onset atrial fibrillation (AF) in patients undergoing BVP and LBBAP. METHODS: The I-CLAS study (International Collaborative LBBAP Study) included patients with left ventricular ejection fraction ≤35% who underwent BVP or LBBAP for cardiac resynchronization therapy between January 2018 and June 2022 at 15 centers. We performed propensity score-matched analysis of LBBAP and BVP in a 1:1 ratio. We assessed the incidence of VT/VF and new-onset AF among patients with no history of AF. Time to sustained VT/VF and time to new-onset AF was analyzed using the Cox proportional hazards survival model. RESULTS: Among 1778 patients undergoing cardiac resynchronization therapy (BVP, 981; LBBAP, 797), there were 1414 propensity score-matched patients (propensity score-matched BVP, 707; propensity score-matched LBBAP, 707). The occurrence of VT/VF was significantly lower with LBBAP compared with BVP (4.2% versus 9.3%; hazard ratio, 0.46 [95% CI, 0.29-0.74]; P<0.001). The incidence of VT storm (>3 episodes in 24 hours) was also significantly lower with LBBAP compared with BVP (0.8% versus 2.5%; P=0.013). Among 299 patients with cardiac resynchronization therapy pacemakers (BVP, 111; LBBAP, 188), VT/VF occurred in 8 patients in the BVP group versus none in the LBBAP group (7.2% versus 0%; P<0.001). In 1194 patients with no history of VT/VF or antiarrhythmic therapy (BVP, 591; LBBAP, 603), the occurrence of VT/VF was significantly lower with LBBAP than with BVP (3.2% versus 7.3%; hazard ratio, 0.46 [95% CI, 0.26-0.81]; P=0.007). Among patients with no history of AF (n=890), the occurrence of new-onset AF >30 s was significantly lower with LBBAP than with BVP (2.8% versus 6.6%; hazard ratio, 0.34 [95% CI, 0.16-0.73]; P=0.008). The incidence of AF lasting >24 hours was also significantly lower with LBBAP than with BVP (0.7% versus 2.9%; P=0.015). CONCLUSIONS: LBBAP was associated with a lower incidence of sustained VT/VF and new-onset AF compared with BVP. This difference remained significant after adjustment for differences in baseline characteristics between patients with BVP and LBBAP. Physiological resynchronization by LBBAP may be associated with lower risk of arrhythmias compared with BVP.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Eletrocardiografia
3.
Circulation ; 150(8): e183-e196, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-38984417

RESUMO

The rapid technological advancements in cardiac implantable electronic devices such as pacemakers, implantable cardioverter defibrillators, and loop recorders, coupled with a rise in the number of patients with these devices, necessitate an updated clinical framework for periprocedural management. The introduction of leadless pacemakers, subcutaneous and extravascular defibrillators, and novel device communication protocols underscores the imperative for clinical updates. This scientific statement provides an inclusive framework for the periprocedural management of patients with these devices, encompassing the planning phase, procedure, and subsequent care coordinated with the primary device managing clinic. Expert contributions from anesthesiologists, cardiac electrophysiologists, and cardiac nurses are consolidated to appraise current evidence, offer patient and health system management strategies, and highlight key areas for future research. The statement, pertinent to a wide range of health care professionals, underscores the importance of quality care pathways for patient safety, optimal device function, and minimization of hemodynamic disturbances or arrhythmias during procedures. Our primary objective is to deliver quality care to the expanding patient cohort with cardiac implanted electronic devices, offering direction in the era of evolving technologies and laying a foundation for sustained education and practice enhancement.


Assuntos
American Heart Association , Desfibriladores Implantáveis , Marca-Passo Artificial , Assistência Perioperatória , Humanos , Desfibriladores Implantáveis/normas , Estados Unidos , Assistência Perioperatória/normas , Assistência Perioperatória/métodos , Equipe de Assistência ao Paciente , Arritmias Cardíacas/terapia
4.
Circulation ; 147(21): 1568-1578, 2023 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-36960730

RESUMO

BACKGROUND: Treatment options for high-risk Brugada syndrome (BrS) with recurrent ventricular fibrillation (VF) are limited. Catheter ablation is increasingly performed but a large study with long-term outcome data is lacking. We report the results of the multicenter, international BRAVO (Brugada Ablation of VF Substrate Ongoing Registry) for treatment of high-risk symptomatic BrS. METHODS: We enrolled 159 patients (median age 42 years; 156 male) with BrS and spontaneous VF in BRAVO; 43 (27%) of them had BrS and early repolarization pattern. All but 5 had an implantable cardioverter-defibrillator for cardiac arrest (n=125) or syncope (n=34). A total of 140 (88%) had experienced numerous implantable cardioverter-defibrillator shocks for spontaneous VF before ablation. All patients underwent a percutaneous epicardial substrate ablation with electroanatomical mapping except for 8 who underwent open-thoracotomy ablation. RESULTS: In all patients, VF/BrS substrates were recorded in the epicardial surface of the right ventricular outflow tract; 45 (29%) patients also had an arrhythmic substrate in the inferior right ventricular epicardium and 3 in the posterior left ventricular epicardium. After a single ablation procedure, 128 of 159 (81%) patients remained free of VF recurrence; this number increased to 153 (96%) after a repeated procedure (mean 1.2±0.5 procedures; median=1), with a mean follow-up period of 48±29 months from the last ablation. VF burden and frequency of shocks decreased significantly from 1.1±2.1 per month before ablation to 0.003±0.14 per month after the last ablation (P<0.0001). The Kaplan-Meier VF-free survival beyond 5 years after the last ablation was 95%. The only variable associated with a VF-free outcome in multivariable analysis was normalization of the type 1 Brugada ECG, both with and without sodium-channel blockade, after the ablation (hazard ratio, 0.078 [95% CI, 0.008 to 0.753]; P=0.0274). There were no arrhythmic or cardiac deaths. Complications included hemopericardium in 4 (2.5%) patients. CONCLUSIONS: Ablation treatment is safe and highly effective in preventing VF recurrence in high-risk BrS. Prospective studies are needed to determine whether it can be an alternative treatment to implantable cardioverter-defibrillator implantation for selected patients with BrS. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04420078.


Assuntos
Síndrome de Brugada , Ablação por Cateter , Desfibriladores Implantáveis , Humanos , Masculino , Adulto , Fibrilação Ventricular , Eletrocardiografia/métodos , Ventrículos do Coração , Síndrome de Brugada/cirurgia , Síndrome de Brugada/complicações , Desfibriladores Implantáveis/efeitos adversos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sistema de Registros
5.
Circulation ; 147(10): 812-823, 2023 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-36700426

RESUMO

BACKGROUND: Benefit from cardiac resynchronization therapy (CRT) varies by QRS characteristics; individual randomized trials are underpowered to assess benefit for relatively small subgroups. METHODS: The authors analyzed patient-level data from pivotal CRT trials (MIRACLE [Multicenter InSync Randomized Clinical Evaluation], MIRACLE-ICD [Multicenter InSync ICD Randomized Clinical Evaluation], MIRACLE-ICD II [Multicenter InSync ICD Randomized Clinical Evaluation II], REVERSE [Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction], RAFT [Resynchronization-Defibrillation for Ambulatory Heart Failure], BLOCK-HF [Biventricular Versus Right Ventricular Pacing in Heart Failure Patients with Atrioventricular Block], COMPANION [Comparison of Medical Therapy, Pacing and Defibrillation in Heart Failure], and MADIT-CRT [Multicenter Automatic Defibrillator Implantation Trial - Cardiac Resynchronization Therapy]) using Bayesian Hierarchical Weibull survival regression models to assess CRT benefit by QRS morphology (left bundle branch block [LBBB], n=4549; right bundle branch block [RBBB], n=691; and intraventricular conduction delay [IVCD], n=1024) and duration (with 150-ms partition). The continuous relationship between QRS duration and CRT benefit was also examined within subgroups defined by QRS morphology. The primary end point was time to heart failure hospitalization (HFH) or death; a secondary end point was time to all-cause death. RESULTS: Of 6264 patients included, 25% were women, the median age was 66 [interquartile range, 58 to 73] years, and 61% received CRT (with or without an implantable cardioverter defibrillator). CRT was associated with an overall lower risk of HFH or death (hazard ratio [HR], 0.73 [credible interval (CrI), 0.65 to 0.84]), and in subgroups of patients with QRS ≥150 ms and either LBBB (HR, 0.56 [CrI, 0.48 to 0.66]) or IVCD (HR, 0.59 [CrI, 0.39 to 0.89]), but not RBBB (HR 0.97 [CrI, 0.68 to 1.34]; Pinteraction <0.001). No significant association for CRT with HFH or death was observed when QRS was <150 ms (regardless of QRS morphology) or in the presence of RBBB. Similar relationships were observed for all-cause death. CONCLUSIONS: CRT is associated with reduced HFH or death in patients with QRS ≥150 ms and LBBB or IVCD, but not for those with RBBB. Aggregating RBBB and IVCD into a single "non-LBBB" category when selecting patients for CRT should be reconsidered. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifiers: NCT00271154, NCT00251251, NCT00267098, and NCT00180271.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Feminino , Idoso , Masculino , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Bloqueio de Ramo/complicações , Terapia de Ressincronização Cardíaca/efeitos adversos , Teorema de Bayes , Ensaios Clínicos Controlados Aleatórios como Assunto , Desfibriladores Implantáveis/efeitos adversos , Resultado do Tratamento , Eletrocardiografia
6.
Circulation ; 147(9): 718-727, 2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-36335467

RESUMO

BACKGROUND: Hypertrophic cardiomyopathy (HCM) can be associated with an abnormal exercise response. In adults with HCM, abnormal results on exercise stress testing are predictive of heart failure outcomes. Our goal was to determine whether an abnormal exercise response is associated with adverse outcomes in pediatric patients with HCM. METHODS: In an international cohort study including 20 centers, phenotype-positive patients with primary HCM who were <18 years of age at diagnosis were included. Abnormal exercise response was defined as a blunted blood pressure response and new or worsened ST- or T-wave segment changes or complex ventricular ectopy. Sudden cardiac death (SCD) events were defined as a composite of SCD and aborted sudden cardiac arrest. Using Kaplan-Meier survival, competing outcomes, and Cox regression analyses, we analyzed the association of abnormal exercise test results with transplant and SCD event-free survival. RESULTS: Of 724 eligible patients, 630 underwent at least 1 exercise test. There were no major differences in clinical characteristics between those with or without an exercise test. The median age at exercise testing was 13.8 years (interquartile range, 4.7 years); 78% were male and 39% were receiving beta-blockers. A total of 175 (28%) had abnormal test results. Patients with abnormal test results had more severe septal hypertrophy, higher left atrial diameter z scores, higher resting left ventricular outflow tract gradient, and higher frequency of myectomy compared with participants with normal test results (P<0.05). Compared with normal test results, abnormal test results were independently associated with lower 5-year transplant-free survival (97% versus 88%, respectively; P=0.005). Patients with exercise-induced ischemia were most likely to experience all-cause death or transplant (hazard ratio, 4.86 [95% CI, 1.69-13.99]), followed by those with an abnormal blood pressure response (hazard ratio, 3.19 [95% CI, 1.32-7.71]). Exercise-induced ischemia was also independently associated with lower SCD event-free survival (hazard ratio, 3.32 [95% CI, 1.27-8.70]). Exercise-induced ectopy was not associated with survival. CONCLUSIONS: Exercise abnormalities are common in childhood HCM. An abnormal exercise test result was independently associated with lower transplant-free survival, especially in those with an ischemic or abnormal blood pressure response with exercise. Exercise-induced ischemia was also independently associated with SCD events. These findings argue for routine exercise testing in childhood HCM as part of ongoing risk assessment.


Assuntos
Cardiomiopatia Hipertrófica , Teste de Esforço , Masculino , Feminino , Humanos , Estudos de Coortes , Prevalência , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/cirurgia , Arritmias Cardíacas/etiologia , Fatores de Risco
7.
Circulation ; 148(11): 862-871, 2023 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-37555345

RESUMO

BACKGROUND: Ventricular arrhythmia is an important cause of mortality in patients with ischemic left ventricular dysfunction. Revascularization with coronary artery bypass graft or percutaneous coronary intervention is often recommended for these patients before implantation of a cardiac defibrillator because it is assumed that this may reduce the incidence of fatal and potentially fatal ventricular arrhythmias, although this premise has not been evaluated in a randomized trial to date. METHODS: Patients with severe left ventricular dysfunction, extensive coronary disease, and viable myocardium were randomly assigned to receive either percutaneous coronary intervention (PCI) plus optimal medical and device therapy (OMT) or OMT alone. The composite primary outcome was all-cause death or aborted sudden death (defined as an appropriate implantable cardioverter defibrillator therapy or a resuscitated cardiac arrest) at a minimum of 24 months, analyzed as time to first event on an intention-to-treat basis. Secondary outcomes included cardiovascular death or aborted sudden death, appropriate implantable cardioverter defibrillator (ICD) therapy or sustained ventricular arrhythmia, and number of appropriate ICD therapies. RESULTS: Between August 28, 2013, and March 19, 2020, 700 patients were enrolled across 40 centers in the United Kingdom. A total of 347 patients were assigned to the PCI+OMT group and 353 to the OMT alone group. The mean age of participants was 69 years; 88% were male; 56% had hypertension; 41% had diabetes; and 53% had a clinical history of myocardial infarction. The median left ventricular ejection fraction was 28%; 53.1% had an implantable defibrillator inserted before randomization or during follow-up. All-cause death or aborted sudden death occurred in 144 patients (41.6%) in the PCI group and 142 patients (40.2%) in the OMT group (hazard ratio, 1.03 [95% CI, 0.82-1.30]; P=0.80). There was no between-group difference in the occurrence of any of the secondary outcomes. CONCLUSIONS: PCI was not associated with a reduction in all-cause mortality or aborted sudden death. In patients with ischemic cardiomyopathy, PCI is not beneficial solely for the purpose of reducing potentially fatal ventricular arrhythmias. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01920048.


Assuntos
Desfibriladores Implantáveis , Disfunção Ventricular Esquerda , Humanos , Masculino , Idoso , Feminino , Volume Sistólico , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Função Ventricular Esquerda , Arritmias Cardíacas/etiologia , Disfunção Ventricular Esquerda/etiologia , Desfibriladores Implantáveis/efeitos adversos , Resultado do Tratamento
8.
Circulation ; 145(5): 321-329, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34779221

RESUMO

BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/normas , Idoso , Arritmias Cardíacas/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
9.
Circulation ; 145(25): 1829-1838, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35369700

RESUMO

BACKGROUND: Optimal timing for catheter ablation of ventricular tachycardia is an important unresolved issue. There are no randomized trials evaluating the benefit of ablation after the first implantable cardioverter defibrillator (ICD) shock. METHODS: We conducted a 2-phase, prospective, multicenter, randomized clinical trial. Patients with ischemic or nonischemic dilated cardiomyopathy and primary or secondary prevention indication for ICD were enrolled in an initial observational phase until first appropriate shock (phase A). After reconsenting, patients were randomly assigned 1:1 in phase B to immediate ablation (within 2 months from shock delivery) or continuation of standard therapy. The primary end point was a composite of death from any cause or hospitalization for worsening heart failure. Amiodarone intake was not allowed except for documented atrial tachyarrhythmias. On July 23, 2021, phase B of the trial was interrupted as a result of the first interim analysis on the basis of the Bayesian adaptive design. RESULTS: Of the 517 patients enrolled in phase A, 154 (30%) had ventricular tachycardia, 56 (11%) received an appropriate shock over a median follow-up of 2.4 years (interquartile range, 1.4-4.4), and 47 of 56 (84%) agreed to participate in phase B. After 24.2 (8.5-24.4) months, the primary end point occurred in 1 of 23 (4%) patients in the ablation group and 10 of 24 (42%) patients in the control group (hazard ratio, 0.11 [95% CI, 0.01-0.85]; P=0.034). The results met the prespecified termination criterion of >99% Bayesian posterior probability of superiority of treatment over standard therapy. No deaths were observed in the ablation group versus 8 deaths (33%) in the control group (P=0.004); there was 1 worsening heart failure hospitalization in the ablation group (4%) versus 4 in the control group (17%; P=0.159). ICD shocks were less frequent in the ablation group (9%) than in the control group (42%; P=0.039). CONCLUSIONS: Ventricular tachycardia ablation after first appropriate shock was associated with a reduced risk of the combined death or worsening heart failure hospitalization end point, lower mortality, and fewer ICD shocks. These findings provide support for considering ventricular tachycardia ablation after the first ICD shock. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01547208.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Teorema de Bayes , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Insuficiência Cardíaca/terapia , Humanos , Prognóstico , Estudos Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
10.
Circulation ; 145(25): 1839-1849, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35507499

RESUMO

BACKGROUND: Catheter ablation as first-line therapy for ventricular tachycardia (VT) at the time of implantable cardioverter defibrillator (ICD) implantation has not been adopted into clinical guidelines. Also, there is an unmet clinical need to prospectively examine the role of VT ablation in patients with nonischemic cardiomyopathy, an increasingly prevalent population that is referred for advanced therapies globally. METHODS: We conducted an international, multicenter, randomized controlled trial enrolling 180 patients with cardiomyopathy and monomorphic VT with an indication for ICD implantation to assess the role of early, first-line ablation therapy. A total of 121 patients were randomly assigned (1:1) to ablation plus an ICD versus conventional medical therapy plus an ICD. Patients who refused ICD (n=47) were followed in a prospective registry after stand-alone ablation treatment. The primary outcome was a composite end point of VT recurrence, cardiovascular hospitalization, or death. RESULTS: Randomly assigned patients had a mean age of 55 years (interquartile range, 46-64) and left ventricular ejection fraction of 40% (interquartile range, 30%-49%); 81% were male. The underlying heart disease was ischemic cardiomyopathy in 35%, nonischemic cardiomyopathy in 30%, and arrhythmogenic cardiomyopathy in 35%. Ablation was performed a median of 2 days before ICD implantation (interquartile range, 5 days before to 14 days after). At 31 months, the primary outcome occurred in 49.3% of the ablation group and 65.5% in the control group (hazard ratio, 0.58 [95% CI, 0.35-0.96]; P=0.04). The observed difference was driven by a reduction in VT recurrence in the ablation arm (hazard ratio, 0.51 [95%CI, 0.29-0.90]; P=0.02). A statistically significant reduction in both ICD shocks (10.0% versus 24.6%; P=0.03) and antitachycardia pacing (16.2% versus 32.8%; P=0.04) was observed in patients who underwent ablation compared with control. No differences in cardiovascular hospitalization (32.0% versus. 33.7%; hazard ratio, 0.82 [95% CI, 0.43-1.56]; P=0.55) or mortality (8.9% versus 8.8%; hazard ratio, 1.40 [95% CI, 0.38-5.22]; P=0.62]) were observed. Ablation-related complications occurred in 8.3% of patients. CONCLUSIONS: Among patients with cardiomyopathy of varied causes, early catheter ablation performed at the time of ICD implantation significantly reduced the composite primary outcome of VT recurrence, cardiovascular hospitalization, or death. These findings were driven by a reduction in ICD therapies. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02848781.


Assuntos
Cardiomiopatias , Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Cardiomiopatias/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Função Ventricular Esquerda
11.
Circulation ; 146(13): 964-975, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-36000392

RESUMO

BACKGROUND: Cardiac sarcoidosis (CS) predisposes to sudden cardiac death (SCD). Guidelines for implantable cardioverter defibrillators (ICDs) in CS have been issued by the Heart Rhythm Society in 2014 and the American College of Cardiology/American Heart Association/Heart Rhythm Society consortium in 2017. How well they discriminate high from low risk remains unknown. METHODS: We analyzed the data of 398 patients with CS detected in Finland from 1988 through 2017. All had clinical cardiac manifestations. Histological diagnosis was myocardial in 193 patients (definite CS) and extracardiac in 205 (probable CS). Patients with and without Class I or IIa ICD indications at presentation were identified, and subsequent occurrences of SCD (fatal or aborted) and sustained ventricular tachycardia were recorded, as were ICD indications emerging first on follow-up. RESULTS: Over a median of 4.8 years, 41 patients (10.3%) had fatal (n=8) or aborted (n=33) SCD, and 98 (24.6%) experienced SCD or sustained ventricular tachycardia as the first event. By the Heart Rhythm Society guideline, Class I or IIa ICD indications were present in 339 patients (85%) and absent in 59 (15%), of whom 264 (78%) and 30 (51%), respectively, received an ICD. Cumulative 5-year incidence of SCD was 10.7% (95% CI, 7.4%-15.4%) in patients with ICD indications versus 4.8% (95% CI, 1.2%-19.1%) in those without (χ2=1.834, P=0.176). The corresponding rates of SCD were 13.8% (95% CI, 9.1%-21.0%) versus 6.3% (95% CI, 0.7%-54.0%; χ2=0.814, P=0.367) in definite CS and 7.6% (95% CI, 3.8%-15.1%) versus 3.3% (95% CI, 0.5%-22.9%; χ2=0.680, P=0.410) in probable CS. In multivariable regression analysis, SCD was predicted by definite histological diagnosis (P=0.033) but not by Class I or IIa ICD indications (P=0.210). In patients without ICD indications at presentation, 5-year incidence of SCD, sustained ventricular tachycardia, and emerging Class I or IIa indications was 53% (95% CI, 40%-71%). By the American College of Cardiology/American Heart Association/Heart Rhythm Society guideline, all patients with complete data (n=245) had Class I or IIa indications for ICD implantation. CONCLUSIONS: Current ICD guidelines fail to distinguish a truly low-risk group of patients with clinically manifest CS, the 5-year risk of SCD approaching 5% despite absent ICD indications. Further research is needed on prognostic factors, including the role of diagnostic histology. Meanwhile, all patients with CS presenting with clinical cardiac manifestations should be considered for an ICD implantation.


Assuntos
Desfibriladores Implantáveis , Miocardite , Sarcoidose , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Humanos , Incidência , Miocardite/complicações , Fatores de Risco , Sarcoidose/complicações , Sarcoidose/diagnóstico , Sarcoidose/epidemiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/terapia
12.
Circulation ; 145(10): 754-764, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-34889650

RESUMO

BACKGROUND: Identification of patients with nonischemic cardiomyopathy who may benefit from prophylactic implantation of a cardioverter-defibrillator. We hypothesized that periodic repolarization dynamics (PRD), a marker of repolarization instability associated with sympathetic activity, could be used to identify patients who will benefit from prophylactic implantable cardioverter defibrillator (ICD) implantation. METHODS: We performed a post hoc analysis of DANISH (Danish ICD Study in Patients With Dilated Cardiomyopathy), in which patients with nonischemic cardiomyopathy, left ventricular ejection fraction (LVEF) ≤35%, and elevated NT-proBNP (N-terminal probrain natriuretic peptides) were randomized to ICD implantation or control group. Patients were included in the PRD substudy if they had a 24-hour Holter monitor recording at baseline with technically acceptable ECG signals during the night hours (00:00-06:00). PRD was assessed using wavelet analysis according to previously validated methods. The primary end point was all-cause mortality. Cox regression models were adjusted for age, sex, NT-proBNP, estimated glomerular filtration rate, LVEF, atrial fibrillation, ventricular pacing, diabetes, cardiac resynchronization therapy, and mean heart rate. We proposed PRD ≥10 deg2 as an exploratory cut-off value for ICD implantation. RESULTS: A total of 748 of the 1116 patients in DANISH qualified for the PRD substudy. During a mean follow-up period of 5.1±2.0 years, 82 of 385 patients died in the ICD group and 85 of 363 patients died in the control group (P=0.40). In Cox regression analysis, PRD was independently associated with mortality (hazard ratio [HR], 1.28 [95% CI, 1.09-1.50] per SD increase; P=0.003). PRD was significantly associated with mortality in the control group (HR, 1.51 [95% CI, 1.25-1.81]; P<0.001) but not in the ICD group (HR, 1.04 [95% CI, 0.83-1.54]; P=0.71). There was a significant interaction between PRD and the effect of ICD implantation on mortality (P=0.008), with patients with higher PRD having greater benefit in terms of mortality reduction. ICD implantation was associated with an absolute mortality reduction of 17.5% in the 280 patients with PRD ≥10 deg2 (HR, 0.54 [95% CI, 0.34-0.84]; P=0.006; number needed to treat=6), but not in the 468 patients with PRD <10 deg2 (HR, 1.17 [95% CI, 0.77-1.78]; P=0.46; P for interaction=0.01). CONCLUSIONS: Increased PRD identified patients with nonischemic cardiomyopathy in whom prophylactic ICD implantation led to significant mortality reduction.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Desfibriladores Implantáveis , Cardiomiopatias/diagnóstico , Cardiomiopatias/terapia , Morte Súbita Cardíaca/prevenção & controle , Dinamarca/epidemiologia , Humanos , Volume Sistólico , Função Ventricular Esquerda
13.
Circulation ; 145(10): 742-753, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-34913361

RESUMO

BACKGROUND: Regulatory authorities of most industrialized countries recommend 6 months of private driving restriction after implantation of a secondary prevention implantable cardioverter-defibrillator (ICD). These driving restrictions result in significant inconvenience and social implications. This study aimed to assess the incidence rate of appropriate device therapies in contemporary recipients of a secondary prevention ICD. METHODS: This retrospective study at 3 Canadian tertiary care centers enrolled consecutive patients with new secondary prevention ICD implants between 2016 and 2020. RESULTS: For a median of 760 days (324, 1190 days), 721 patients were followed up. The risk of recurrent ventricular arrhythmia was highest during the first 3 months after device insertion (34.4%) and decreased over time (10.6% between 3 and 6 months, 11.7% between 6 and 12 months). The corresponding incidence rate per 100 patient-days was 0.48 (95% CI, 0.35-0.64) at 90 days, 0.28 (95% CI, 0.17-0.45) at 180 days, and 0.21 (95% CI, 0.13-0.33) between 181 and 365 days after ICD insertion (P<0.001). The cumulative incidence of arrhythmic syncope resulting in sudden cardiac incapacitation was 1.8% within the first 90 days and subsequently dropped to 0.4% between 91 and 180 days (P<0.001) after ICD insertion. CONCLUSIONS: The incidence rate of appropriate therapies resulting in sudden cardiac incapacitation in contemporary recipients of a secondary prevention ICD is much lower than previously reported and declines significantly after the first 3 months. Lowering driving restrictions to 3 months after the index cardiac event seems safe, and revision of existing guidelines should be considered in countries still adhering to a 6-month period. Existing restrictions for private driving after implantation of a secondary prevention ICD should be reconsidered.


Assuntos
Desfibriladores Implantáveis , Canadá , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Humanos , Prevenção Primária/métodos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
14.
Eur Radiol ; 33(2): 1229-1242, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36029346

RESUMO

OBJECTIVES: Cardiac implantable electronic device (CIED)-induced metal artefacts possibly significantly diminish the diagnostic value of magnetic resonance imaging (MRI), particularly cardiac MR (CMR). Right-sided generator implantation, wideband late-gadolinium enhancement (LGE) technique and raising the ipsilateral arm to the generator during CMR scanning may reduce the CIED-induced image artefacts. We assessed the impact of generator location and the arm-raised imaging position on the CIED-induced artefacts in CMR. METHODS: We included all clinically indicated CMRs performed on patients with normal cardiac anatomy and a permanent CIED with endocardial pacing leads between November 2011 and October 2019 in our institution (n = 171). We analysed cine and LGE sequences using the American Heart Association 17-segment model for the presence of artefacts. RESULTS: Right-sided generator implantation and arm-raised imaging associated with a significantly increased number of artefact-free segments. In patients with a right-sided pacemaker, the median percentage of artefact-free segments in short-axis balanced steady-state free precession LGE was 93.8% (IQR 9.4%, n = 53) compared with 78.1% (IQR 20.3%, n = 58) for left-sided pacemaker (p < 0.001). In patients with a left-sided implantable cardioverter-defibrillator, the median percentage of artefact-free segments reached 87.5% (IQR 6.3%, n = 9) using arm-raised imaging, which fell to 62.5% (IQR 34.4%, n = 9) using arm-down imaging in spoiled gradient echo short-axis cine (p = 0.02). CONCLUSIONS: Arm-raised imaging represents a straightforward method to reduce CMR artefacts in patients with left-sided generators and can be used alongside other image quality improvement methods. Right-sided generator implantation could be considered in CIED patients requiring subsequent CMR imaging to ensure sufficient image quality. KEY POINTS: • Cardiac implantable electronic device (CIED)-induced metal artefacts may significantly diminish the diagnostic value of an MRI, particularly in cardiac MRIs. • Raising the ipsilateral arm relative to the CIED generator is a cost-free, straightforward method to significantly reduce CIED-induced artefacts on cardiac MRIs in patients with a left-sided generator. • Right-sided generator implantation reduces artefacts compared with left-sided implantation and could be considered in CIED patients requiring subsequent cardiac MRIs to ensure adequate image quality in the future.


Assuntos
Desfibriladores Implantáveis , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Meios de Contraste , Gadolínio , Imageamento por Ressonância Magnética/métodos
15.
Circulation ; 143(14): 1343-1358, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33478245

RESUMO

BACKGROUND: Nonischemic cardiomyopathy is a leading cause of reduced left ventricular ejection fraction (LVEF) and is associated with high mortality risk from progressive heart failure and arrhythmias. Myocardial scar on cardiovascular magnetic resonance imaging is increasingly recognized as a risk marker for adverse outcomes; however, left ventricular dysfunction remains the basis for determining a patient's eligibility for primary prophylaxis with implantable cardioverter-defibrillator. We investigated the relationship of LVEF and scar with long-term mortality and mode of death in a large cohort of patients with nonischemic cardiomyopathy. METHODS: This study is a prospective, longitudinal outcomes registry of 1020 consecutive patients with nonischemic cardiomyopathy who underwent clinical cardiovascular magnetic resonance imaging for the assessment of LVEF and scar at 3 centers. RESULTS: During a median follow-up of 5.2 (interquartile range, 3.8, 6.6) years, 277 (27%) patients died. On survival analysis, LVEF ≤35% and scar were strongly associated with all-cause (log-rank test P=0.002 and P<0.001, respectively) and cardiac death (P=0.001 and P<0.001, respectively). Whereas scar was strongly related to sudden cardiac death (SCD; P=0.001), there was no significant association between LVEF ≤35% and SCD risk (P=0.57). On multivariable analysis including established clinical factors, LVEF and scar are independent risk markers of all-cause and cardiac death. The addition of LVEF provided incremental prognostic value but insignificant discrimination improvement by C-statistic for all-cause and cardiac death, but no incremental prognostic value for SCD. Conversely, scar extent demonstrated significant incremental prognostic value and discrimination improvement for all 3 end points. On net reclassification analysis, the addition of LVEF resulted in no significant improvement for all-cause death (11.0%; 95% CI, -6.2% to 25.9%), cardiac death (9.8%; 95% CI, -5.7% to 29.3%), or SCD (7.5%; 95% CI, -41.2% to 42.9%). Conversely, the addition of scar extent resulted in significant reclassification improvement of 25.5% (95% CI, 11.7% to 41.0%) for all-cause death, 27.0% (95% CI, 11.6% to 45.2%) for cardiac death, and 40.6% (95% CI, 10.5% to 71.8%) for SCD. CONCLUSIONS: Myocardial scar and LVEF are both risk markers for all-cause and cardiac death in patients with nonischemic cardiomyopathy. However, whereas myocardial scar has strong and incremental prognostic value for SCD risk stratification, LVEF has no incremental prognostic value over clinical measures. Scar assessment should be incorporated into patient selection criteria for primary prevention implantable cardioverter-defibrillator placement.


Assuntos
Cardiomiopatias/complicações , Cardiopatias/etiologia , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Feminino , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Análise de Sobrevida , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/patologia
16.
Circulation ; 144(20): 1590-1597, 2021 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-34780252

RESUMO

BACKGROUND: Prescription opioids are a major contributor to the ongoing epidemic of persistent opioid use (POU). The incidence of POU among opioid-naïve patients after cardiac implantable electronic device (CIED) procedures is unknown. METHODS: This retrospective cohort study used data from a national administrative claims database from 2004 to 2018 of patients undergoing CIED procedures. Adult patients were included if they were opioid-naïve during the 180-day period before the procedure and did not undergo another procedure with anesthesia in the next 180 days. POU was defined by filling an additional opioid prescription >30 days after the CIED procedure. RESULTS: Of the 143 400 patients who met the inclusion criteria, 15 316 (11%) filled an opioid prescription within 14 days of surgery. Among these patients, POU occurred in 1901 (12.4%) patients 30 to 180 days after surgery. The likelihood of developing POU was increased for patients who had a history of drug abuse (odds ratio, 1.52; P=0.005), preoperative muscle relaxant (odds ratio, 1.52; P<0.001) or benzodiazepine (odds ratio, 1.23; P=0.001) use, or opioid use in the previous 5 years (OR, 1.76; P<0.0001). POU did not differ after subcutaneous implantable cardioverter defibrillator or other CIED procedures (11.1 versus 12.4%; P=0.5). In a sensitivity analysis excluding high-risk patients who were discharged to a facility or who had a history of drug abuse or previous opioid, benzodiazepine, or muscle relaxant use, 8.9% of the remaining cohort had POU. Patients prescribed >135 mg of oral morphine equivalents had a significantly increased risk of POU. CONCLUSIONS: POU is common after CIED procedures, and 12% of patients continued to use opioids >30 days after surgery. Higher initially prescribed oral morphine equivalent doses were associated with developing POU.


Assuntos
Analgésicos Opioides/uso terapêutico , Desfibriladores Implantáveis , Cuidados Pós-Operatórios , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/efeitos adversos , Tomada de Decisão Clínica , Bases de Dados Factuais , Gerenciamento Clínico , Prescrições de Medicamentos/normas , Prescrições de Medicamentos/estatística & dados numéricos , Duração da Terapia , Pesquisas sobre Atenção à Saúde , Humanos , Vigilância em Saúde Pública
17.
Circulation ; 143(1): 7-17, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33073614

RESUMO

BACKGROUND: The subcutaneous (S) implantable cardioverter-defibrillator (ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, had less left ventricular dysfunction, and received more inappropriate shocks (IAS) than in typical transvenous ICD trials. The UNTOUCHED trial (Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction) was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms. METHODS: Primary prevention patients with left ventricular ejection fraction ≤35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥250 beats per minute and morphology discrimination for rates ≥200 and <250 beats per minute. Patients were followed for 18 months. The primary end point was the IAS-free rate compared with a 91.6% performance goal, derived from the results for the ICD-only patients in the MADIT-RIT study (Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy). Kaplan-Meier analyses were performed to evaluate event-free rates for IAS, all-cause shock, and complications. Multivariable proportional hazard analysis was performed to determine predictors of end points. RESULTS: S-ICD implant was attempted in 1116 patients, and 1111 patients were included in postimplant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% were women, 23.4% were Black, 53.5% had ischemic heart disease, 87.7% had symptomatic heart failure, and the mean left ventricular ejection fraction was 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (lower confidence limit, 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the 3-incision technique, no history of atrial fibrillation, and ischemic cause. The 18-month all-cause shock-free rate was 90.6% (lower confidence limit, 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication-free rate at 18 months was 92.7%. CONCLUSIONS: This study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of comorbidities in comparison with earlier S-ICD trials. The inappropriate shock rate (3.1% at 1 year) is the lowest reported for the S-ICD and lower than many transvenous ICD studies using contemporary programming to reduce IAS. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02433379.


Assuntos
Arritmias Cardíacas/prevenção & controle , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/normas , Prevenção Primária/métodos , Volume Sistólico/fisiologia , Adulto , Idoso , Arritmias Cardíacas/fisiopatologia , Estudos de Coortes , Morte Súbita Cardíaca/epidemiologia , Desfibriladores/normas , Desfibriladores/tendências , Desfibriladores Implantáveis/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
18.
Circulation ; 142(3): 217-229, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32418493

RESUMO

BACKGROUND: Hypertrophic cardiomyopathy is the leading cause of sudden cardiac death (SCD) in children and young adults. Our objective was to develop and validate a SCD risk prediction model in pediatric hypertrophic cardiomyopathy to guide SCD prevention strategies. METHODS: In an international multicenter observational cohort study, phenotype-positive patients with isolated hypertrophic cardiomyopathy <18 years of age at diagnosis were eligible. The primary outcome variable was the time from diagnosis to a composite of SCD events at 5-year follow-up: SCD, resuscitated sudden cardiac arrest, and aborted SCD, that is, appropriate shock following primary prevention implantable cardioverter defibrillators. Competing risk models with cause-specific hazard regression were used to identify and quantify clinical and genetic factors associated with SCD. The cause-specific regression model was implemented using boosting, and tuned with 10 repeated 4-fold cross-validations. The final model was fitted using all data with the tuned hyperparameter value that maximizes the c-statistic, and its performance was characterized by using the c-statistic for competing risk models. The final model was validated in an independent external cohort (SHaRe [Sarcomeric Human Cardiomyopathy Registry], n=285). RESULTS: Overall, 572 patients met eligibility criteria with 2855 patient-years of follow-up. The 5-year cumulative proportion of SCD events was 9.1% (14 SCD, 25 resuscitated sudden cardiac arrests, and 14 aborted SCD). Risk predictors included age at diagnosis, documented nonsustained ventricular tachycardia, unexplained syncope, septal diameter z-score, left ventricular posterior wall diameter z score, left atrial diameter z score, peak left ventricular outflow tract gradient, and presence of a pathogenic variant. Unlike in adults, left ventricular outflow tract gradient had an inverse association, and family history of SCD had no association with SCD. Clinical and clinical/genetic models were developed to predict 5-year freedom from SCD. Both models adequately discriminated between patients with and without SCD events with a c-statistic of 0.75 and 0.76, respectively, and demonstrated good agreement between predicted and observed events in the primary and validation cohorts (validation c-statistic 0.71 and 0.72, respectively). CONCLUSION: Our study provides a validated SCD risk prediction model with >70% prediction accuracy and incorporates risk factors that are unique to pediatric hypertrophic cardiomyopathy. An individualized risk prediction model has the potential to improve the application of clinical practice guidelines and shared decision making for implantable cardioverter defibrillator insertion. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT0403679.


Assuntos
Cardiomiopatia Hipertrófica/epidemiologia , Morte Súbita Cardíaca/epidemiologia , Modelos Estatísticos , Adolescente , Fatores Etários , Algoritmos , Cardiomiopatia Hipertrófica/complicações , Criança , Morte Súbita Cardíaca/etiologia , Feminino , Humanos , Masculino , Vigilância em Saúde Pública , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
19.
Circulation ; 141(13): 1057-1067, 2020 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-32000514

RESUMO

BACKGROUND: Catheter ablation for ventricular tachycardia (VT) reduces the recurrence of VT in patients with implantable cardioverter-defibrillators (ICDs). The appropriate timing of VT ablation and its effects on mortality and heart failure progression remain a matter of debate. In patients with life-threatening arrhythmias necessitating ICD implantation, we compared outcomes of preventive VT ablation (undertaken before ICD implantation to prevent ICD shocks for VT) and deferred ablation after 3 ICD shocks for VT. METHODS: The BERLIN VT study (Preventive Ablation of Ventricular Tachycardia in Patients With Myocardial Infarction) was a prospective, open, parallel, randomized trial performed at 26 centers. Patients with stable ischemic cardiomyopathy, a left ventricular ejection fraction between 30% and 50%, and documented VT were randomly assigned 1:1 to a preventive or deferred ablation strategy. The primary outcome was a composite of all-cause death and unplanned hospitalization for either symptomatic ventricular arrhythmia or worsening heart failure. Secondary outcomes included sustained ventricular tachyarrhythmia and appropriate ICD therapy. We hypothesized that preventive ablation strategy would be superior to deferred ablation strategy in the intention-to-treat population. RESULTS: During a mean follow-up of 396±284 days, the primary end point occurred in 25 (32.9%) of 76 patients in the preventive ablation group and 23 (27.7%) of 83 patients in the deferred ablation group (hazard ratio, 1.09 [95% CI, 0.62-1.92]; P=0.77). On the basis of prespecified criteria for interim analyses, the study was terminated early for futility. In the preventive versus deferred ablation group, 6 versus 2 patients died (7.9% versus 2.4%; P=0.18), 8 versus 2 patients were admitted for worsening heart failure (10.4% versus 2.3%; P=0.062), and 15 versus 21 patients were hospitalized for symptomatic ventricular arrhythmia (19.5% versus 25.3%; P=0.27). Among secondary outcomes, the proportions of patients with sustained ventricular tachyarrhythmia (39.7% versus 48.2%; P=0.050) and appropriate ICD therapy (34.2% versus 47.0%; P=0.020) were numerically reduced in the preventive ablation group. CONCLUSIONS: Preventive VT ablation before ICD implantation did not reduce mortality or hospitalization for arrhythmia or worsening heart failure during 1 year of follow-up compared with the deferred ablation strategy. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02501005.


Assuntos
Cardiomiopatias/complicações , Ablação por Cateter/métodos , Desfibriladores Implantáveis/normas , Taquicardia Ventricular/terapia , Idoso , Cardiomiopatias/cirurgia , Feminino , Humanos , Masculino , Estudos Prospectivos
20.
Circulation ; 140(19): 1530-1539, 2019 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-31476893

RESUMO

BACKGROUND: Most randomized trials on implantable cardioverter-defibrillator (ICD) use for primary prevention of sudden cardiac death in heart failure with reduced ejection fraction enrolled patients >20 years ago. We investigated the association between ICD use and all-cause mortality in a contemporary heart failure with reduced ejection fraction cohort and examined relevant subgroups. METHODS: Patients from the Swedish Heart Failure Registry fulfilling the European Society of Cardiology criteria for primary-prevention ICD were included. The association between ICD use and 1-year and 5-year all-cause and cardiovascular (CV) mortality was assessed by Cox regression models in a 1:1 propensity score-matched cohort and in prespecified subgroups. RESULTS: Of 16 702 eligible patients, only 1599 (10%) had an ICD. After matching, 1305 ICD recipients were compared with 1305 nonrecipients. ICD use was associated with a reduction in all-cause mortality risk within 1 year (hazard ratio, 0.73 [95% CI, 0.60-0.90]) and 5 years (hazard ratio, 0.88 [95% CI, 0.78-0.99]). Results were consistent in all subgroups including patients with versus without ischemic heart disease, men versus women, those aged <75 versus ≥75 years, those with earlier versus later enrollment in the Swedish heart failure registry, and patients with versus without cardiac resynchronization therapy. CONCLUSIONS: In a contemporary heart failure with reduced ejection fraction population, ICD for primary prevention was underused, although it was associated with reduced short- and long-term all-cause mortality. This association was consistent across all the investigated subgroups. These results call for better implementation of ICD therapy.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/tendências , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/tendências , Insuficiência Cardíaca/terapia , Padrões de Prática Médica/tendências , Prevenção Primária/tendências , Idoso , Idoso de 80 Anos ou mais , Morte Súbita Cardíaca/epidemiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Sistema de Registros , Medição de Risco , Fatores de Risco , Suécia/epidemiologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA