1.
Mol Imaging ; 23: 15353508241245265, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38952398

RESUMO

This meeting report summarizes a consultants meeting that was held at International Atomic Energy Agency Headquarters, Vienna, in July 2022 to provide an update on the development of multimodality imaging by combining nuclear medicine imaging agents with other nonradioactive molecular probes and/or biomedical imaging techniques.


Assuntos
Imagem Multimodal , Medicina Nuclear , Medicina Nuclear/métodos , Medicina Nuclear/tendências , Imagem Multimodal/métodos , Humanos
2.
Eur J Nucl Med Mol Imaging ; 51(3): 695-706, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37924340

RESUMO

PURPOSE: This study aimed to compare the predictive value of CT attenuation-corrected stress total perfusion deficit (AC-sTPD) and non-corrected stress TPD (NC-sTPD) for major adverse cardiac events (MACE) in obese patients undergoing cadmium zinc telluride (CZT) SPECT myocardial perfusion imaging (MPI). METHODS: The study included 4,585 patients who underwent CZT SPECT/CT MPI for clinical indications (chest pain: 56%, shortness of breath: 13%, other: 32%) at Yale New Haven Hospital (age: 64 ± 12 years, 45% female, body mass index [BMI]: 30.0 ± 6.3 kg/m2, prior coronary artery disease: 18%). The association between AC-sTPD or NC-sTPD and MACE defined as the composite end point of mortality, nonfatal myocardial infarction or late coronary revascularization (> 90 days after SPECT) was evaluated with survival analysis. RESULTS: During a median follow-up of 25 months, 453 patients (10%) experienced MACE. In patients with BMI ≥ 35 kg/m2 (n = 931), those with AC-sTPD ≥ 3% had worse MACE-free survival than those with AC-sTPD < 3% (HR: 2.23, 95% CI: 1.40 - 3.55, p = 0.002) with no difference in MACE-free survival between patients with NC-sTPD ≥ 3% and NC-sTPD < 3% (HR:1.06, 95% CI:0.67 - 1.68, p = 0.78). AC-sTPD had higher AUC than NC-sTPD for the detection of 2-year MACE in patients with BMI ≥ 35 kg/m2 (0.631 versus 0.541, p = 0.01). In the overall cohort AC-sTPD had a higher ROC area under the curve (AUC, 0.641) than NC-sTPD (0.608; P = 0.01) for detection of 2-year MACE. In patients with BMI ≥ 35 kg/m2 AC sTPD provided significant incremental prognostic value beyond NC sTPD (net reclassification index: 0.14 [95% CI: 0.20 - 0.28]). CONCLUSIONS: AC sTPD outperformed NC sTPD in predicting MACE in patients undergoing SPECT MPI with BMI ≥ 35 kg/m2. These findings highlight the superior prognostic value of AC-sTPD in this patient population and underscore the importance of CT attenuation correction.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Imagem de Perfusão do Miocárdio , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X , Prognóstico , Obesidade/complicações , Obesidade/diagnóstico por imagem
3.
Eur J Nucl Med Mol Imaging ; 51(8): 2247-2259, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38221570

RESUMO

OBJECTIVES: This study aimed to evaluate the level of evidence of expert recommendations and guidelines for clinical indications and procedurals in hybrid nuclear cardiovascular imaging. METHODS: From inception to August 2023, a PubMed literature analysis of the latest version of guidelines for clinical hybrid cardiovascular imaging techniques including SPECT(/CT), PET(/CT), and PET(/MRI) was performed in two categories: (1) for clinical indications for all-in primary diagnosis; subgroup in prognosis and therapy evaluation; and for (2) imaging procedurals. We surveyed to what degree these followed a standard methodology to collect the data and provide levels of evidence, and for which topic systematic review evidence was executed. RESULTS: A total of 76 guidelines, published between 2013 and 2023, were included. The evidence of guidelines was based on systematic reviews in 7.9% of cases, non-systematic reviews in 47.4% of cases, a mix of systematic and non-systematic reviews in 19.7%, and 25% of guidelines did not report any evidence. Search strategy was reported in 36.8% of cases. Strengths of recommendation were clearly reported in 25% of guidelines. The notion of external review was explicitly reported in 23.7% of cases. Finally, the support of a methodologist was reported in 11.8% of the included guidelines. CONCLUSION: The use of evidence procedures for developing for evidence-based cardiovascular hybrid imaging recommendations and guidelines is currently suboptimal, highlighting the need for more standardized methodological procedures.


Assuntos
Guias de Prática Clínica como Assunto , Humanos , Imagem Multimodal/normas , Medicina Baseada em Evidências , Doenças Cardiovasculares/diagnóstico por imagem , Medicina Nuclear/normas
4.
Skeletal Radiol ; 53(9): 1783-1798, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38409548

RESUMO

Imaging plays a central role in the management of patients with bone tumors. A number of imaging modalities are available, with different techniques having unique applications that render their use advantageous for various clinical purposes. Coupled with detailed clinical assessment, radiological imaging can assist clinicians in reaching a proper diagnosis, determining appropriate management, evaluating response to treatment, and monitoring for tumor recurrence. Although radiography is still the initial imaging test of choice for a patient presenting with a suspected bone tumor, technological innovations in the last decades have advanced the role of other imaging modalities for assessing bone tumors, including advances in computed tomography, magnetic resonance imaging, scintigraphy, and hybrid imaging techniques that combine two existing modalities, providing clinicians with diverse tools for bone tumor imaging applications. Determining the most suitable modality to use for a particular application requires familiarity with the modality in question, its advancements, and its limitations. This review highlights the various imaging techniques currently available and emphasizes the latest developments in imaging, offering a framework that can help guide the imaging of patients with bone tumors.


Assuntos
Neoplasias Ósseas , Humanos , Neoplasias Ósseas/diagnóstico por imagem , Diagnóstico por Imagem/métodos
5.
Cardiovasc Diabetol ; 22(1): 129, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-37254111

RESUMO

BACKGROUND: Patients with prediabetes or diabetes are at increased risk of developing cardiovascular disease and adverse outcomes. First-line coronary computed tomography angiography (CTA) followed by selective use of positron emission tomography (PET) myocardial perfusion imaging is a feasible strategy to diagnose and risk-stratify patients with suspected coronary artery disease (CAD). The aim of the present study was to study whether diabetes changes the relationship of CAD and long-term outcome. METHODS: We retrospectively identified consecutive symptomatic patients who underwent coronary CTA for suspected CAD. In patients with suspected obstructive CAD on CTA, myocardial ischemia was evaluated by 15O-water PET myocardial perfusion imaging. The relationship of the phenotype of CAD and long-term outcome in patients with no diabetes, prediabetes, or type 2 diabetes was investigated. A composite endpoint included all-cause mortality, myocardial infarction (MI), and unstable angina pectoris (UAP). RESULTS: A total of 1743 patients were included: 1214 (70%) non-diabetic, 259 (15%) prediabetic, and 270 (16%) type 2 diabetic patients. During 6.43 years of median follow-up, 164 adverse events occurred (106 deaths, 41 MIs, 17 UAPs). The prevalence of normal coronary arteries on CTA was highest in the non-diabetic patients (39%). The prevalence of hemodynamically significant CAD (abnormal perfusion) increased from 14% in non-diabetic patients to 20% in prediabetic and 27% in diabetic patients. The event rate was lowest in patients with normal coronary arteries and highest in patients with concomitant type 2 diabetes and hemodynamically significant CAD (annual event rate 0.2% vs. 4.7%). However, neither prediabetes nor diabetes were independent predictors of the composite adverse outcome after adjustment for the clinical risk factors and imaging findings. CONCLUSIONS: Coronary CTA followed by selective downstream use of PET myocardial perfusion imaging predicts long-term outcome similarly in non-diabetic and diabetic patients.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus Tipo 2 , Imagem de Perfusão do Miocárdio , Estado Pré-Diabético , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/complicações , Estado Pré-Diabético/complicações , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/epidemiologia , Estudos Retrospectivos , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada , Tomografia Computadorizada Multidetectores , Imagem de Perfusão do Miocárdio/métodos , Valor Preditivo dos Testes
6.
Eur J Nucl Med Mol Imaging ; 51(1): 68-80, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37676502

RESUMO

OBJECTIVE: To evaluate the value of SPECT/CT (single photon emission computed tomography/computed tomography) in foot and ankle arthrodesis and development of secondary osteoarthritis in the adjacent joints. MATERIALS AND METHODS: SPECT/CT of 140 joints in the foot and ankle (34 upper ankle (UA), 28 lower ankle (LA), 27 talonavicular (TN), 12 calcaneo-cuboidal (CC), and 39 other smaller joints after arthrodesis in 72 patients were evaluated retrospectively regarding fusion grade in CT (0 = no fusion, 1 = < 50% fusion, 2 = > 50% fusion, 3 = complete fusion) and radiotracer uptake (0 = no uptake, 1 = mild uptake, 2 = moderate uptake, 3 = high uptake) on SPECT/CT. Severity of osteoarthritis (1 = mild, 2 = moderate, 3 = severe) and radiotracer uptake grade in adjacent joints was also assessed. In 54 patients, clinical information about interventions in the follow-up was available. RESULTS: According to the SPECT/CT, arthrodesis was successful (grade 2 or 3 CT fusion and grade 0 or 1 uptake) in 73% (25/34) of UA joints, 71% (20/28) of LA joints, 67% (18/27) TN, 100% (12/12) CC joints, and 62% (24/39) of other smaller joints. In 12 joints, there were discrepant findings in SPECT/CT (fusion grade 2 and uptake grade 2 or 3 (n = 9); or, fusion grade 0 or 1 and uptake grade 1 (n = 3)). The fusion rate 6-12 months after arthrodesis was 42% (14/33), 59% (20/34) after 13-24 months, and 89% (65/73) after more than 24 months, respectively. Average radiotracer uptake in arthrodesis decreased with age: 6-12 months: 1.60, 12-24 months: 1.32, > 24 months: 0.38. There was a significant negative correlation between radiotracer uptake grade and CT fusion grade. Osteoarthritis was observed in 131 adjacent joints. During the post scan follow-up, additional arthrodeses were performed in 33 joints, of which 11 joints were re-arthrodesis and 22 were new arthrodeses in osteoarthritic adjacent joints. All these 11 joints with failed arthrodesis had grade 0 of CT fusion and grade 2 or 3 of radiotracer uptake. All 22 adjacent joints with osteoarthritis, which subsequently underwent arthrodesis, had grade 2 or 3 radiotracer uptake, and the primary arthrodesis joints were healed and fused in all these cases. CONCLUSION: Bone SPECT/CT is a valuable hybrid imaging tool in the evaluation of foot and ankle arthrodesis and gives additional useful information about the development of secondary osteoarthritis in the adjacent joints with higher value for the assessment of secondary osteoarthritis. A practical four-type classification ('Lucerne Criteria') combining metabolic and morphologic SPECT/CT information for evaluation of arthrodesis joints has been proposed.


Assuntos
Tornozelo , Osteoartrite , Humanos , Lactente , Estudos Retrospectivos , Resultado do Tratamento , Osteoartrite/diagnóstico por imagem , Osteoartrite/cirurgia , Artrodese/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
7.
J Magn Reson Imaging ; 57(5): 1301-1311, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36524452

RESUMO

Simultaneous positron emission tomography and magnetic resonance imaging (PET-MRI) combines the anatomical detail and tissue characterization of MRI with the functional information from PET. Within the coronary arteries, this hybrid technique can be used to identify biological activity combined with anatomically high-risk plaque features to better understand the processes underlying coronary atherosclerosis. Furthermore, the downstream effects of coronary artery disease on the myocardium can be characterized by providing information on myocardial perfusion, viability, and function. This review will describe the current capabilities of PET-MRI in coronary artery disease and discuss the limitations and future directions of this emerging technique. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 3.


Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Miocárdio/patologia , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia
8.
J Magn Reson Imaging ; 57(3): 690-705, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36326548

RESUMO

Complex engineered systems are often equipped with suites of sensors and ancillary devices that monitor their performance and maintenance needs. MRI scanners are no different in this regard. Some of the ancillary devices available to support MRI equipment, the ones of particular interest here, have the distinction of actually participating in the image acquisition process itself. Most commonly, such devices are used to monitor physiological motion or variations in the scanner's imaging fields, allowing the imaging and/or reconstruction process to adapt as imaging conditions change. "Classic" examples include electrocardiography (ECG) leads and respiratory bellows to monitor cardiac and respiratory motion, which have been standard equipment in scan rooms since the early days of MRI. Since then, many additional sensors and devices have been proposed to support MRI acquisitions. The main physical properties that they measure may be primarily "mechanical" (eg acceleration, speed, and torque), "acoustic" (sound and ultrasound), "optical" (light and infrared), or "electromagnetic" in nature. A review of these ancillary devices, as currently available in clinical and research settings, is presented here. In our opinion, these devices are not in competition with each other: as long as they provide useful and unique information, do not interfere with each other and are not prohibitively cumbersome to use, they might find their proper place in future suites of sensors. In time, MRI acquisitions will likely include a plurality of complementary signals. A little like the microbiome that provides genetic diversity to organisms, these devices can provide signal diversity to MRI acquisitions and enrich measurements. Machine-learning (ML) algorithms are well suited at combining diverse input signals toward coherent outputs, and they could make use of all such information toward improved MRI capabilities. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.


Assuntos
Coração , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Coração/fisiologia , Eletrocardiografia , Movimento (Física) , Movimento/fisiologia
9.
J Nucl Cardiol ; 30(1): 298-312, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-34622428

RESUMO

Cardiac neuroendocrine tumors (NETs) are particularly rare tumors that can lead to a very poor clinical outcome, partly because of metastases but mainly because of manifestations of the hormonal activity they exhibit. Prompt diagnosis is important in order to start the most effective treatment for their removal or management, with the fewest complications. They are often difficult to diagnose, especially in their early stages. One of the reasons for this is that the heart is an organ with a high rate of metabolism and is located in close proximity to other high-metabolism organs. In addition, the anatomic location and their small size render their diagnosis extremely challenging. In recent years, hybrid imaging methods have revolutionized the diagnostic approach to oncology patients and have established a place in the diagnosis of cardiac NETs, because they provide both anatomical and functional information at the same time. Positron emission tomography/computed tomography (PET/CT), PET/magnetic resonance imaging (PET/MRI) and single-photon emission computed tomography/CT (SPECT/CT) are widely used in clinical practice because of the very important metabolic information, the high sensitivity and specificity. However, prospective studies are needed to confirm the true clinical and prognostic value of various hybrid imaging diagnostic techniques in cardiac NETs.


Assuntos
Neoplasias Cardíacas , Tumores Neuroendócrinos , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Imagem Multimodal
10.
J Nucl Cardiol ; 30(1): 343-353, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35819715

RESUMO

AIMS: This prospective, single-center study sought to assess to what extent there is interference between the hybrid technique of single-photon emission tomography-computed tomography with technetium99m-hexamethylpropyleneamine oxime-labeled leukocytes (99mTc-HMPAO-SPECT/CT) and antimicrobial therapy in patients with infective endocarditis (IE). METHODS AND RESULTS: During the years 2015-2019, we enrolled 205 consecutive adults with suspected IE, all underwent 99mTc-HMPAO-SPECT/CT. The study population was divided into those who had received antimicrobial therapy up to 30 days prior to 99mTc-HMPAO-SPECT/CT (group 1, n = 96) and those who had not (group 2, n = 109). Patients were prospectively observed for 12 ± 10 months. Group 1 presented higher positive predictive values (91.89% vs. 60.00%, = 0.001), and decreased negative predictive values (77.97% vs. 90.54%, P = 0.04). Patients treated with antimicrobial therapy displayed false-negative 99mTc-HMPAO-SPECT/CT results more often [odds ratio (OR), 4.63; 95% confidence interval (CI), 1.41-15.23, P = .01], particularly when intravenous (OR 5.37; 95% CI 1.73-16.62, P = .004), definite (OR 9.43; 95% CI 2.65-33.51, P = .001), and combination antibiotic regimens (OR 8.1; 95% CI 2.57-25.64, P = .001) had been administered. CONCLUSION: Prior antibiotic therapy affects 99mTc-HMPAO-SPECT/CT diagnostic properties. Patients treated with antimicrobial therapy display false-negative 99mTc-HMPAO-SPECT/CT results more often, especially if intravenous, definite, or combination regimens are administered.


Assuntos
Anti-Infecciosos , Endocardite Bacteriana , Endocardite , Adulto , Humanos , Tecnécio Tc 99m Exametazima , Estudos Prospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Leucócitos
11.
J Nucl Cardiol ; 30(6): 2349-2360, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37162738

RESUMO

Advances in the prevention and treatment of cardiovascular disease (CVD) over the last decades have led to a marked reduction in mortality for CVD. Nevertheless, atherosclerosis leading to coronary artery disease and stroke remains one of the most common causes of death in the world. The usefulness of imaging tests in the early identification of disease led to identify subjects at major risk of poor outcomes, suggesting risk factor modification. The aim of this article is to analyze the state of art of combined imaging in patients at risk of CVD referred to MPI evaluation, to highlight the present and potential features able to provide incremental prognostic information to help clinicians in patient management and to reduce adverse events.


Assuntos
Aterosclerose , Doenças Cardiovasculares , Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Doenças Cardiovasculares/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Fatores de Risco , Prognóstico
12.
J Nucl Cardiol ; 30(6): 2676-2691, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37587328

RESUMO

BACKGROUND: Cardiac metastases from neuroendocrine neoplasms (NENs) are being detected with increasing frequency, although the optimal imaging strategy remains unclear. We performed a single-center retrospective study to explore the role of somatostatin receptor positron emission tomography/computed tomography (SSTR PET/CT) and cardiac magnetic resonance imaging (CMR) in NEN cardiac metastases, determine the degree of concordance between the findings of these imaging modalities, and examine the advantages and disadvantages of each imaging technique. A secondary aim was to determine if cardiac metastases were associated with adverse cardiac events during peptide receptor radionuclide therapy (PRRT). METHODS AND RESULTS: 19 patients with NEN cardiac metastases were identified. A retrospective review of electronic medical records was performed, and if available SSTR PET/CT and CMR were blindly re-reviewed by imaging specialists, documenting the number and location of cardiac metastases. All 19 patients had SSTR PET/CT, and 10/19 patients had CMR. SSTR PET/CT identified more metastases than CMR. When identified on CMR, metastases were more accurately localized. 12/19 patients received PRRT, with no cardiac adverse effects. CONCLUSION: SSTR PET/CT and CMR are complementary investigations in the imaging of NEN cardiac metastases. SSTR PET/CT appears more sensitive for lesion detection, and CMR offers better lesion characterization. Both investigations present useful information for the planning of treatment including PRRT, which was administered safely.


Assuntos
Neoplasias Cardíacas , Tumores Neuroendócrinos , Neoplasias do Timo , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Receptores de Somatostatina , Estudos Retrospectivos , Tumores Neuroendócrinos/diagnóstico por imagem , Imageamento por Ressonância Magnética , Neoplasias Cardíacas/diagnóstico por imagem , Melanoma Maligno Cutâneo
13.
J Nucl Cardiol ; 30(6): 2750-2759, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37656345

RESUMO

BACKGROUND: Machine Learning (ML) allows integration of the numerous variables delivered by cardiac PET/CT, while traditional survival analysis can provide explainable prognostic estimates from a restricted number of input variables. We implemented a hybrid ML-and-survival analysis of multimodal PET/CT data to identify patients who developed myocardial infarction (MI) or death in long-term follow up. METHODS: Data from 739 intermediate risk patients who underwent coronary CT and selectively stress 15O-water-PET perfusion were analyzed for the occurrence of MI and all-cause mortality. Images were evaluated segmentally for atherosclerosis and absolute myocardial perfusion through 75 variables that were integrated through ML into an ML-CCTA and an ML-PET score. These scores were then modeled along with clinical variables through Cox regression. This hybridized model was compared against an expert interpretation-based and a calcium score-based model. RESULTS: Compared with expert- and calcium score-based models, the hybridized ML-survival model showed the highest performance (CI .81 vs .71 and .64). The strongest predictor for outcomes was the ML-CCTA score. CONCLUSION: Prognostic modeling of PET/CT data for the long-term occurrence of adverse events may be improved through ML imaging score integration and subsequent traditional survival analysis with clinical variables. This hybridization of methods offers an alternative to traditional survival modeling of conventional expert image scoring and interpretation.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Angiografia Coronária/métodos , Cálcio , Tomografia Computadorizada por Raios X/métodos , Infarto do Miocárdio/diagnóstico por imagem , Aprendizado de Máquina , Prognóstico , Análise de Sobrevida , Imagem de Perfusão do Miocárdio/métodos
14.
J Nucl Cardiol ; 30(6): 2721-2735, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37605060

RESUMO

BACKGROUND: Various parameters derived from technetium-99m pyrophosphate (99mTc-PYP) single-photon emission computed tomography (SPECT) correlate with the severity of transthyretin amyloid cardiomyopathy (ATTR-CM). However, the optimal metrics and image acquisition timing required to quantify the disease burden remain uncertain. METHODS AND RESULTS: We retrospectively evaluated 99mTc-PYP SPECT/CT images of 23 patients diagnosed with ATTR-CM using endomyocardial biopsies and/or gene tests. All patients were assessed by SPECT/CT 1 hour after 99mTc-PYP injection, and 13 of them were also assessed at 3 hours. We quantified 99mTc-PYP uptake using the volumetric parameters, cardiac PYP volume (CPV) and cardiac PYP activity (CPA). We also calculated the SUVmax ratios of myocardial SUVmax/blood pool SUVmax, myocardial SUVmax/bone SUVmax, and the SUVmax retention index. We assessed the correlations between uptake parameters and the four functional parameters associated with prognosis, namely left ventricular ejection fraction, global longitudinal strain, myocardial extracellular volume, and troponin T. CPV and CPA correlated more closely than the SUVmax ratios with the four prognostic factors. Significant correlations between volumetric parameters and prognostic factors were equivalent between 1 and 3 hours. CONCLUSIONS: The disease burden of ATTR-CM was quantified more accurately by volumetric evaluation of 99mTc-PYP SPECT/CT than SUVmax ratios and the performance was equivalent between 1 and 3 hours.


Assuntos
Amiloidose , Cardiomiopatias , Humanos , Difosfatos , Pirofosfato de Tecnécio Tc 99m , Pré-Albumina/genética , Cardiomiopatias/genética , Volume Sistólico , Estudos Retrospectivos , Função Ventricular Esquerda , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Compostos Radiofarmacêuticos
15.
J Nucl Cardiol ; 30(5): 1810-1821, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36855009

RESUMO

BACKGROUND: Myocardial glycosphingolipid accumulation in patients with Fabry disease (FD) causes biochemical and structural changes. This study aimed to investigate sympathetic innervation in FD using hybrid cardiac positron emission tomography (PET)/magnetic resonance imaging (MRI). METHODS AND RESULTS: Patients with different stages of Fabry disease were prospectively enrolled to undergo routine CMR at 1.5T, followed by 3T hybrid cardiac PET/MRI with [11C]meta-hydroxyephedrine ([11C]mHED). Fourteen patients with either no evidence of cardiac involvement (n = 5), evidence of left ventricular hypertrophy (LVH) (n = 3), or evidence of LVH and fibrosis via late gadolinium enhancement (LGE) (n = 6) were analyzed. Compared to patients without LVH, patients with LVH or LVH and LGE had lower median T1 relaxation times (ms) at 1.5 T (1007 vs. 889 vs. 941 ms, p = 0.003) and 3T (1290 vs. 1172 vs. 1184 p = .014). Myocardial denervation ([11C]mHED retention < 7%·min) was prevalent only in patients with fibrosis, where a total of 16 denervated segments was found in two patients. The respective area of denervation exceeded the area of LGE in both patients (24% vs. 36% and 4% vs. 32%). However, sympathetic innervation defects ([11C]mHED retention ≤ 9%·min) occurred in all study groups. Furthermore, a reduced sympathetic innervation correlated with an increased left ventricular mass (p = .034, rs = - 0.57) and a reduced global longitudinal strain (GLS) (p = 0.023, rs = - 0.6). CONCLUSION: Hybrid cardiac PET/MR with [11C]mHED revealed sympathetic innervation defects, accompanied by impaired GLS, in early stages of Fabry disease. However, denervation is only present in patients with advanced stages of FD showing fibrosis on CMR.


Assuntos
Efedrina/análogos & derivados , Doença de Fabry , Humanos , Doença de Fabry/diagnóstico por imagem , Doença de Fabry/complicações , Meios de Contraste , Gadolínio , Tomografia Computadorizada por Raios X/efeitos adversos , Hipertrofia Ventricular Esquerda/complicações , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética , Simpatectomia/efeitos adversos , Fibrose , Espectroscopia de Ressonância Magnética/efeitos adversos
16.
J Nucl Cardiol ; 30(2): 590-603, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36195826

RESUMO

BACKGROUND: Machine learning (ML) has been previously applied for prognostication in patients undergoing SPECT myocardial perfusion imaging (MPI). We evaluated whether including attenuation CT coronary artery calcification (CAC) scoring improves ML prediction of major adverse cardiovascular events (MACE) in patients undergoing SPECT/CT MPI. METHODS: From the REFINE SPECT Registry 4770 patients with SPECT/CT performed at a single center were included (age: 64 ± 12 years, 45% female). ML algorithm (XGBoost) inputs were clinical risk factors, stress variables, SPECT imaging parameters, and expert-observer CAC scoring using CT attenuation correction scans performed to obtain CT attenuation maps. The ML model was trained and validated using tenfold hold-out validation. Receiver Operator Characteristics (ROC) curves were analyzed for prediction of MACE. MACE-free survival was evaluated with standard survival analyses. RESULTS: During a median follow-up of 24.1 months, 475 patients (10%) experienced MACE. Higher area under the ROC curve for MACE was observed with ML when CAC scoring was included (CAC-ML score, 0.77, 95% confidence interval [CI] 0.75-0.79) compared to ML without CAC (ML score, 0.75, 95% CI 0.73-0.77, P = .005) and when compared to CAC score alone (0.71, 95% CI 0.68-0.73, P < .001). Among clinical, imaging, and stress parameters, CAC score had highest variable importance for ML. On survival analysis patients with high CAC-ML score (> 0.091) had higher event rate when compared to patients with low CAC-ML score (hazard ratio 5.3, 95% CI 4.3-6.5, P < .001). CONCLUSION: Integration of attenuation CT CAC scoring improves the predictive value of ML risk score for MACE prediction in patients undergoing SPECT MPI.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Cálcio , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X , Aprendizado de Máquina , Prognóstico
17.
J Nucl Cardiol ; 30(3): 1050-1060, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36180767

RESUMO

BACKGROUND: This work investigated the impact of different cardiac gating methods on the assessment of cardiac function by FDG-PET in a cross-validation PET/MR study. METHODS AND RESULTS: MR- and PET-based left ventricular end-diastolic, end-systolic volumes, and ejection fraction (EDV, ESV, and EF) were delineated in 30 patients with a PET/MR examination. Cardiac PET imaging was performed using three ECG gating methods: fixed number of gates per beat (STD), STD with a beat acceptance window (STD-BR), and fixed gate duration (FW). High MR-PET correlations were found in all the values. ESVs correlated better than EDVs and EFs: Pearson's r coefficient [0.92, 0.92, 0.92] in ESV vs [0.75, 0.81, 0.80] in EDV and [0.79, 0.91, 0.87] in EF, for each method [STD, STD-BR, FW]. Biases with respect to MRI for all the evaluated PET methods were less than 13% in EDV, 5% in ESV, and 14% in EF, but with wide limits of agreements, in the range (59-68)% in EDV, (65-70)% in ESV, and (49-71)% in EF. STD showed the strongest disagreement, while there were no marked differences between STD-BR and FW. CONCLUSION: Based on these findings, PET- and MR-based cardiac function parameters were highly correlated but in substantial disagreement with variabilities introduced by the selected PET ECG gating method. The most significant differences were associated with the ECG gating method susceptible to highly irregular beats, while similar performance was observed in the methods using uniform adjustment of gates width per beat with the beat acceptance window, and fixed gate width along all the beats. Thus, strict quality controls of R peak detection are needed to minimize its impact on the function assessment.


Assuntos
Tomografia por Emissão de Pósitrons , Humanos , Eletrocardiografia/métodos , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons/métodos , Reprodutibilidade dos Testes , Volume Sistólico , Função Ventricular Esquerda
18.
J Nucl Cardiol ; 30(4): 1602-1612, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36656496

RESUMO

BACKGROUND: New Block-Sequential-Regularized-Expectation-Maximization (BSREM) image reconstruction technique has been introduced for clinical use mainly for oncologic use. Accurate and quantitative image reconstruction is essential in myocardial perfusion imaging with positron emission tomography (PET) as it utilizes absolute quantitation of myocardial blood flow (MBF). The aim of the study was to evaluate BSREM reconstruction for quantitation in patients with suspected coronary artery disease (CAD). METHODS AND RESULTS: We analyzed cardiac [15O]H2O PET studies of 177 patients evaluated for CAD. Differences between BSREM and Ordered-Subset-Expectation-Maximization with Time-Of-Flight (TOF) and Point-Spread-Function (PSF) modeling (OSEM-TOF-PSF) in terms of MBF, perfusable tissue fraction, and vascular volume fraction were measured. Classification of ischemia was assessed between the algorithms. OSEM-TOF-PSF and BSREM provided similar global stress MBF in patients with ischemia (1.84 ± 0.21 g⋅ml-1⋅min-1 vs 1.86 ± 0.21 g⋅ml-1⋅min-1) and no ischemia (3.26 ± 0.34 g⋅ml-1⋅min-1 vs 3.28 ± 0.34 g⋅ml-1⋅min-1). Global resting MBF was also similar (0.97 ± 0.12 g⋅ml-1⋅min-1 and 1.12 ± 0.06 g⋅ml-1⋅min-1). The largest mean relative difference in MBF values was 7%. Presence of myocardial ischemia was classified concordantly in 99% of patients using OSEM-TOF-PSF and BSREM reconstructions CONCLUSION: OSEM-TOF-PSF and BSREM image reconstructions produce similar MBF values and diagnosis of myocardial ischemia in patients undergoing [15O]H2O PET due to suspected obstructive coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Estudos Retrospectivos , Doença da Artéria Coronariana/diagnóstico por imagem , Teorema de Bayes , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X , Tomografia por Emissão de Pósitrons/métodos , Algoritmos
19.
J Nucl Cardiol ; 30(3): 1235-1245, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36352087

RESUMO

BACKGROUND: We investigated quantitative 99mTc-pyrophosphate (PYP) SPECT/CT reproducibility and accuracy for diagnosing cardiac transthyretin amyloidosis (ATTR), and whether SPECT/CT improved visual and quantitative results compared to SPECT-only. METHODS: Data were reviewed for 318 patients with suspected ATTR who underwent PYP SPECT/CT. Myocardial-to-blood pool count (MBP) ratios were computed and repeated independently > 1 month later. A physician independently scored LV myocardial-to-rib uptake on SPECT/CT as: 0 (negative), 1 < rib (equivocal), 2 = rib (positive) or 3 > rib (positive), and the image quality as: 1 (poor), 2 (adequate), and 3 (good). SPECT-only MBP ratios and visual scores were assessed separately for a subgroup of the first sequential 191 patients. RESULTS: 25% of patients had positive myocardial uptake (myocardial-to-rib uptake score of ≥ 2). SPECT/CT MBP ratios were reproducible (1.35 ± .68 vs 1.33 ± .74, p = .09) and corresponded with visual scores ≥ 2 (ROC AUC = 99 ± 1%) more accurately than SPECT-only MBPs (93 ± 3%, p = .02). SPECT/CT image quality was better than that of SPECT-only (2.7 ± .5 vs 2.1 ± .5, p < .0001) with fewer equivocal results (2.6% vs 22.5%, p < .0001). CONCLUSION: SPECT/CT produces MBP ratios that are reproducible and accurately identify a positive scan, with better image quality and fewer equivocal cases than SPECT-only.


Assuntos
Neuropatias Amiloides Familiares , Cardiomiopatias , Humanos , Difosfatos , Pirofosfato de Tecnécio Tc 99m , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único
20.
Pediatr Radiol ; 53(7): 1443-1453, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36899268

RESUMO

Functional imaging is playing an increasingly important role in pediatric radiology. Hybrid imaging techniques utilizing PET/CT (positron emission tomography/computed tomography), PET/MRI (positron emission tomography/magnetic resonance imaging), or SPECT/CT (single photon emission computed tomography/computed tomography) are now available in nearly every clinical practice. There are an increasing number of indications for the use of functional imaging, including oncologic and infectious indications, and it is essential to select and design the hybrid imaging protocol in order to optimize both the functional and anatomic components of the examination. Optimizing the protocol includes strategies for dose reduction, judicious use of contrast media and diagnostic quality imaging as appropriate, and for the greatest reduction in exposure to ionizing radiation, utilizing PET/MRI, whenever available. This review will provide an overview of hybrid imaging protocol considerations with a focus on oncologic and infectious indications.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Criança , Humanos , Tomografia por Emissão de Pósitrons/métodos , Imagem Multimodal , Imageamento por Ressonância Magnética , Tomografia Computadorizada de Emissão de Fóton Único/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA