Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Clin Ultrasound ; 52(5): 548-557, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38488675

RESUMO

PURPOSE: To investigate power Doppler (PD) activity and tendon structure (between the injured and contralateral limb) in patients with unilateral patellar tendinopathy (PT) using ultrasonography (US). Secondly, the aim was to determine the intra-rater reliability of the PD activity and tendon structure. METHODS: This study analyzed US baseline data from 57 male participants with symptomatic unilateral PT who had been enrolled in one of two randomized clinical trials. Data were analyzed to examine if systematic differences existed between injured and contralateral limbs using Fiji ImageJ. RESULTS: The PD activity of the symptomatic tendon was larger 25.6 (Q1 = 14.9; Q3 = 41.6) mm2 than the asymptomatic 0 (Q1 = 0.0; Q3 = 0.0) mm2 (p < 0.001). There was a significantly greater tendon thickness at the proximal (2.5 mm 95% CI [2.0; 3.0]), mid (0.8 mm 95% CI [0.5; 1.1]), and distal (0.2 mm 95% CI [0.1; 0.4]) part of the tendon for the symptomatic compared to the asymptomatic tendon. Intra-rater reliability for PD activity and tendon structure ranged from moderate-to-excellent (0.74; 0.99). CONCLUSION: These results provide mean estimates for tendon thickness of symptomatic and asymptomatic tendons, that can be used for clinicians to reliably estimate pathological tendon thickness.


Assuntos
Ligamento Patelar , Tendinopatia , Humanos , Masculino , Ligamento Patelar/diagnóstico por imagem , Tendinopatia/diagnóstico por imagem , Adulto , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Ultrassonografia Doppler/métodos , Pessoa de Meia-Idade , Adulto Jovem
2.
Phys Occup Ther Pediatr ; : 1-14, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39007754

RESUMO

AIM: The Test of Gross Motor Development Third Edition (TGMD-3) is used to assess the development of fundamental movement skills in children from 3 to 10 years old. This study aimed to evaluate the intra-rater, inter-rater, and test-retest reliability and to determine the minimal detectable change (MDC) value of the TGMD-3 in children with developmental coordination disorder (DCD). METHODS: The TGMD-3 was administered to 20 children with DCD. The child's fundamental movement skills were recorded using a digital video camera. Reliability was assessed at two occasions by three raters using the generalizability theory. RESULTS: The TGMD-3 demonstrates good inter-rater reliability for the locomotor skills subscale, the ball skills subscale, and the total score (φ = 0.77 - 0.91), while the intra-rater reliability was even higher (φ = 0.94 - 0.97). Test-retest reliability was also shown to be good (φ = 0.79-0.93). The MDC95 was determined to be 10 points. CONCLUSION: This study provides evidence that the TGMD-3 is a reliable test when used to evaluate fundamental movement skills in children with DCD and suggests that an increase of 10 points represents a significant change in the motor function of a child with DCD.

3.
Medicina (Kaunas) ; 60(6)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38929468

RESUMO

Background and Objectives: Muscle properties are critical for performance and injury risk, with changes occurring due to physical exertion, aging, and neurological conditions. The MyotonPro device offers a non-invasive method to comprehensively assess muscle biomechanical properties. This systematic review evaluates the reliability of MyotonPro across various muscles for diagnostic purposes. Materials and Methods: Following PRISMA guidelines, a comprehensive literature search was conducted in Medline (PubMed), Ovid (Med), Epistemonikos, Embase, Cochrane Library, Clinical trials.gov, and the WHO International Clinical Trials platform. Studies assessing the reliability of MyotonPro across different muscles were included. A methodological quality assessment was performed using established tools, and reviewers independently conducted data extraction. Statistical analysis involved summarizing intra-rater and inter-rater reliability measures across muscles. Results: A total of 48 studies assessing 31 muscles were included in the systematic review. The intra-rater and inter-rater reliability were consistently high for parameters such as frequency and stiffness in muscles of the lower and upper extremities, as well as other muscle groups. Despite methodological heterogeneity and limited data on specific parameters, MyotonPro demonstrated promising reliability for diagnostic purposes across diverse patient populations. Conclusions: The findings suggest the potential of MyotonPro in clinical assessments for accurate diagnosis, treatment planning, and monitoring of muscle properties. Further research is needed to address limitations and enhance the applicability of MyotonPro in clinical practice. Reliable muscle assessments are crucial for optimizing treatment outcomes and improving patient care in various healthcare settings.


Assuntos
Músculo Esquelético , Humanos , Reprodutibilidade dos Testes , Músculo Esquelético/fisiologia , Músculo Esquelético/fisiopatologia , Testes Diagnósticos de Rotina/normas , Testes Diagnósticos de Rotina/métodos
4.
BMC Cancer ; 23(1): 799, 2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37626309

RESUMO

BACKGROUND: In research designs that rely on observational ratings provided by two raters, assessing inter-rater reliability (IRR) is a frequently required task. However, some studies fall short in properly utilizing statistical procedures, omitting essential information necessary for interpreting their findings, or inadequately addressing the impact of IRR on subsequent analyses' statistical power for hypothesis testing. METHODS: This article delves into the recent publication by Liu et al. in BMC Cancer, analyzing the controversy surrounding the Kappa statistic and methodological issues concerning the assessment of IRR. The primary focus is on the appropriate selection of Kappa statistics, as well as the computation, interpretation, and reporting of two frequently used IRR statistics when there are two raters involved. RESULTS: The Cohen's Kappa statistic is typically utilized to assess the level of agreement between two raters when there are two categories or for unordered categorical variables with three or more categories. On the other hand, when it comes to evaluating the degree of agreement between two raters for ordered categorical variables comprising three or more categories, the weighted Kappa is a widely used measure. CONCLUSION: Despite not substantially affecting the findings of Liu et al.?s study, the statistical dispute underscores the significance of employing suitable statistical methods. Rigorous and accurate statistical results are crucial for producing trustworthy research.


Assuntos
Projetos de Pesquisa , Extremidade Superior , Humanos , Reprodutibilidade dos Testes
5.
Surg Endosc ; 37(3): 2070-2077, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36289088

RESUMO

BACKGROUND: Phase and step annotation in surgical videos is a prerequisite for surgical scene understanding and for downstream tasks like intraoperative feedback or assistance. However, most ontologies are applied on small monocentric datasets and lack external validation. To overcome these limitations an ontology for phases and steps of laparoscopic Roux-en-Y gastric bypass (LRYGB) is proposed and validated on a multicentric dataset in terms of inter- and intra-rater reliability (inter-/intra-RR). METHODS: The proposed LRYGB ontology consists of 12 phase and 46 step definitions that are hierarchically structured. Two board certified surgeons (raters) with > 10 years of clinical experience applied the proposed ontology on two datasets: (1) StraBypass40 consists of 40 LRYGB videos from Nouvel Hôpital Civil, Strasbourg, France and (2) BernBypass70 consists of 70 LRYGB videos from Inselspital, Bern University Hospital, Bern, Switzerland. To assess inter-RR the two raters' annotations of ten randomly chosen videos from StraBypass40 and BernBypass70 each, were compared. To assess intra-RR ten randomly chosen videos were annotated twice by the same rater and annotations were compared. Inter-RR was calculated using Cohen's kappa. Additionally, for inter- and intra-RR accuracy, precision, recall, F1-score, and application dependent metrics were applied. RESULTS: The mean ± SD video duration was 108 ± 33 min and 75 ± 21 min in StraBypass40 and BernBypass70, respectively. The proposed ontology shows an inter-RR of 96.8 ± 2.7% for phases and 85.4 ± 6.0% for steps on StraBypass40 and 94.9 ± 5.8% for phases and 76.1 ± 13.9% for steps on BernBypass70. The overall Cohen's kappa of inter-RR was 95.9 ± 4.3% for phases and 80.8 ± 10.0% for steps. Intra-RR showed an accuracy of 98.4 ± 1.1% for phases and 88.1 ± 8.1% for steps. CONCLUSION: The proposed ontology shows an excellent inter- and intra-RR and should therefore be implemented routinely in phase and step annotation of LRYGB.


Assuntos
Derivação Gástrica , Laparoscopia , Obesidade Mórbida , Humanos , Obesidade Mórbida/cirurgia , Reprodutibilidade dos Testes , Resultado do Tratamento , Complicações Pós-Operatórias/cirurgia
6.
Int Ophthalmol ; 43(12): 4711-4718, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37697080

RESUMO

PURPOSE: To evaluate the effect of EVO+ Visian Implantable Collamer Lens (ICL) implantation on the iridocorneal angle pigmentation and structures. METHODS: Myopic refractive surgery candidates who underwent posterior chamber EVO+ ICL implantation were evaluated preoperatively and 3 and 6 months postoperatively. High-resolution images of the iridocorneal angle (nasal, superior, temporal and inferior quadrants) were acquired during gonioscopy. A masked observer, blinded to study visits and patients' information, evaluated the angle width, apparent iris root insertion, iris configuration, and trabecular meshwork pigmentation according to the Spaeth scale in two different occasions. The intra-rater reliability was estimated using the weighted Gwet's Agreement Coefficient (AC2). Differences between visits were analyzed using the Cochran Q test or the Friedman test. RESULTS: Twenty-one patients (13 females and 8 males) aging 31.3 ± 6.3 years old were recruited. The intra-rater reliability of gonioscopy assessment was excellent for every parameter assessed (AC2 ≥ 0.97). No significant differences were found among the study visits for any quadrant in the angle width (p ≥ 0.74), apparent iris root insertion (p ≥ 0.22), iris configuration (p ≥ 0.21) and trabecular meshwork pigmentation (p ≥ 0.24). Mean pigmentation of trabecular meshwork for the four quadrants did not vary either among visits (p = 0.25). CONCLUSIONS: The EVO+ ICL implantation after uneventful procedures appears not to clinically affect the iridocorneal angle pigmentation and/or structures during a short-medium follow-up using gonioscopy assessment. The intra-rater reliability of glaucoma specialists assessing iridocorneal angle structures using gonioscopy images is very high.


Assuntos
Implante de Lente Intraocular , Transtornos da Pigmentação , Masculino , Feminino , Humanos , Adulto , Reprodutibilidade dos Testes , Implante de Lente Intraocular/métodos , Câmara Anterior , Malha Trabecular/cirurgia , Iris/cirurgia , Pigmentação , Gonioscopia
7.
BMC Geriatr ; 22(1): 137, 2022 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-35177006

RESUMO

BACKGROUND: Given the potential benefits of introducing ultrasound in the clinical assessment of muscle disorders, this study aimed to assess the feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric clinical setting. METHODS: Cross-sectional pilot study in 25 participants (12 patients aged ≥ 70 years in an acute geriatric ward and 13 healthy volunteers aged 25-50 years), assessed by three raters. Muscle thickness measurement was estimated as the distance between the subcutaneous adipose tissue-muscle interface and muscle-bone interface of the radius at 30% proximal of the distance between the styloid process and distal insertion of the biceps brachii muscle of the dominant forearm. Examinations were repeated three times by each rater and intra- and inter-rater reliability was calculated. Feasibility analysis included consideration of technological, economic, legal, operational, and scheduling (TELOS) components. RESULTS: Mean muscle-thickness measurement difference between groups was 4.4 mm (95% confidence interval [CI] 2.4 mm to 6.3 mm], p < 0.001). Intra-rater reliability of muscle-thickness assessment was excellent, with intraclass correlation coefficient (ICC) of 0.947 (95%CI 0.902 to 0.974), 0.969 (95%CI 0.942 to 0.985), and 0.950 (95%CI 0.907 to 0.975) for observer A, B, and C, respectively. Inter-rater comparison showed good agreement (ICC of 0.873 [95%CI 0.73 to 0.94]). Four of the 17 TELOS components considered led to specific recommendations to improve the procedure's feasibility in clinical practice. CONCLUSION: Our findings suggest that US is a feasible tool to assess the thickness of the forearm muscles with good inter-rater and excellent intra-rater reliability in a sample of hospitalized geriatric patients, making it a promising option for use in clinical practice.


Assuntos
Antebraço , Pacientes Internados , Idoso , Estudos Transversais , Estudos de Viabilidade , Antebraço/diagnóstico por imagem , Humanos , Músculo Esquelético/diagnóstico por imagem , Variações Dependentes do Observador , Projetos Piloto , Reprodutibilidade dos Testes , Ultrassonografia
8.
J Hand Ther ; 35(2): 275-281, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35241356

RESUMO

STUDY DESIGN: Observational, descriptive design. BACKGROUND: Despite scapular mobility being essential for the completion of activities of daily living (ADLs), there is currently no established, a reliable goniometric technique to measure scapular protraction and retraction. A proposed method has shown clinically significant inter-rater reliability for a goniometric technique for these measurements. PURPOSE: This observational descriptive study examined the intra-rater reliability of a goniometric technique to assess scapular protraction and retraction among a sample of healthy adults. METHODS: An occupational therapist who is a certified hand therapist (CHT) and an occupational therapy student used goniometry to measure the neutral (resting), protracted, and retracted positions of the right and left scapula for a sample of healthy young adults (n = 54; a total of 108 data points for each measurement). These measurements were compared to analyze intra-rater and inter-rater reliability. RESULTS: For measurements of the scapula in neutral, protraction, and retraction, the standard error of measure (SEM) for repeat measures by the expert and novice raters was < 4.5° and < 3.9° respectively and ICC values ranged from poor to moderate (0.37-0.63). The SEM for measures between evaluators was < 5.0° and the ICC was poor (0.16-0.35). Minimum detectable change (MDC) values as a percentage of the mean (% MDC) ranged between 15.9 and 43.7% for intra-rater reliability and 21.9-52.8% for inter-rater reliability. DISCUSSION: The results of the study were mixed; variance of less than 5° for repeat measures by the same rater and measures between raters suggest clinically acceptable reliability. However, variance as a proportion of available motion (%MDC) demonstrates a broader range both above and below the threshold of 30% suggested for rehabilitation assessments. CONCLUSION: There are few efficient, reliable techniques to measure scapular mobility in clinical practice. The absolute reliability of goniometry to measure scapular protraction and retraction is similar to measurements of other joints. However, additional research and possible refinement of the technique is recommended to further address relative reliability and validity.


Assuntos
Atividades Cotidianas , Escápula , Humanos , Variações Dependentes do Observador , Amplitude de Movimento Articular , Reprodutibilidade dos Testes , Adulto Jovem
9.
J Pak Med Assoc ; 72(10): 1994-1997, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36660987

RESUMO

Objective: To measure the intra-rater and inter-rater reliability of active lumbar extension and flexion movements using dual inclinometer with two different landmarking techniques. METHODS: The reliability study was conducted at the Physical Therapy Department of the University Teaching Hospital, The University of Lahore, Pakistan, in January 2020, and comprised patients of either gender aged >18 years with mild or symptomatic lower back pain, and healthy subjects s controls. Repeated measurements with dual inclinometer were taken by two examiners and data was recorded by two separate observers. A set of three active lumbar extension and flexion movements were performed for an initial warm-up. The examiners repeated a palpation of bony landmarks prior to each trial. The two different landmarking techniques were applied on the lumbar spine to identify the start and end points. Both the examiners measured each participant thrice. For each examiner and each landmarking technique, the three data sets were acquired for active lumbar extension and flexion for a total of 120 sets per session per examiner per landmarking. Each set comprised three alternating active lumbar extension and flexion movements. Data was analysed using SPSS version 26. RESULTS: Of the 40 subjects with mean age 27.8+11.0 years, 19(48%) were males and 21(52%) were females. There were 15(38%) cases; 6(40%) males and 9(60%) females. The remaining 25(62%) were controls. The two landmarking techniques with dual inclinometer produced a high to very high intra-rater reliability (intraclass correlation coefficient:0.73-0.91) for both lumbar extension and flexion movements with moderate to low standard error of measurement values (0.36-1.31), while a high inter-rater reliability (intraclass correlation coefficient: 0.72-0.76; standard error of measurement: 0.52-0.63) for extension measurements and only moderate inter-rater reliability (intraclass correlation coefficient: 0.59-0.65; standard error of measurement: 1.36-1.49) for flexion measurements. Conclusion: Dual inclinometer along with skilled examiners and accurate landmarking methodology provided clinically reliable measurements.


Assuntos
Dor Lombar , Região Lombossacral , Masculino , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Reprodutibilidade dos Testes , Variações Dependentes do Observador , Amplitude de Movimento Articular , Dor Lombar/diagnóstico
10.
Aten Primaria ; 54(6): 102343, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35550948

RESUMO

AIM: To study the intra-rater reliability and feasibility of the HexCom complexity assessment model by analyzing internal consistency, intra-rater reliability and response time. DESIGN: Test-retest study with a selection of 11 clinical situations that cover the full scope of situations assessed by the HexCom model and which are responded to individually. LOCATION: Home care, primary care, hospital and sociosanitary care. Two specialized palliative home care teams (PADES). PARTICIPANTS: A total of 20 professionals comprising 10 experts in palliative home care (PADES) and 10 professionals from general palliative care (primary care, hospital and sociosanitary care). These professionals came from the fields of family medicine (5), internal medicine (2), geriatrics (2), nursing (9), psychology (1) and social work (1). MAIN MEASUREMENTS: Cronbach's alpha, weighted kappa, response time. RESULTS: Cronbach's alpha of 0.91 for HexCom-Red and 0.87 for HexCom-Clin. Intra-rater reliability ranging from good to very good for HexCom-Red (kappa: 0.78-1) and from moderate to very good for HexCom-Clin (kappa: 0.58-0.91). Average response time of 0:57 for HexCom-Red and 3:80min for HexComClin. CONCLUSIONS: HexCom-Red and HexCom-Clin are reliable tools and feasible for use by all professionals involved in both general and specialized palliative care at different levels.


Assuntos
Serviços de Assistência Domiciliar , Cuidados Paliativos , Estudos de Viabilidade , Hospitais , Humanos , Psicometria , Reprodutibilidade dos Testes
11.
Health Qual Life Outcomes ; 18(1): 247, 2020 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-32703292

RESUMO

BACKGROUND: The English version of the Chedoke Arm and Hand Activity Inventory is a validated, upper-limb measure with the purpose of assessing functional recovery of the arm and hand after a stroke. A German translation and cross-cultural adaptation was recently produced and demonstrated high validity, inter-rater reliability and internal consistency. As a follow-up, the present study evaluated the intra-rater reliability and responsiveness of the CAHAI-G for the long and all shortened versions. METHODS: The CAHAI-G and the Action Research Arm Test were assessed on three different measurement events: upon entry (ME1), two to 3 days after entry (ME2), and after three to 4 weeks (ME3). For the intra-rater reliability analysis, the ME1 CAHAI assessments were recorded on video and rated by three therapists to obtain the intraclass coefficients (ICC). The data of all three MEs were analysed in a group of stroke inpatients for the evaluation of responsiveness. To test for responsiveness, the CAHAI-G change data were compared to concurrent instruments: The Global Rating of Change-questionnaire and the Global Rating of Concept-questionnaire. Both served as external criteria. For all CAHAI-G versions (7, 8, 9 or 13 items), the same analysis procedures for the evaluation of the responsiveness parameter were performed. RESULTS: In total, 27 patients (9 females, age 63 ± 13.7) were enrolled in the study. The ICCs for the intra-rater reliability were calculated to be between 0.988 and 0.998 for all CAHAI versions. Responsiveness parameters were as follows from CAHAI-G 7 to 13: Minimal Detectable Change (MDC90) 5.3, 6.0, 6.1, 8.2; Pearson's correlation coefficients CAHAI-Gs with ARAT 0.365, 0.409*, 0.500**, 0.597**. The Area und Under the Curve and the Minimal Clinical Important Difference values for all CAHAI-G versions and the three external criteria ranged between 0.483 to 0.603 and 2.5 to 9.0, respectively. CONCLUSION: In addition to the high validity, inter-rater reliability and internal consistency, the CAHAI-G revealed high intra-rater reliability. The data also suggest an adequate responsiveness of the CAHAI-G versions 9 and 13.


Assuntos
Reabilitação do Acidente Vascular Cerebral/psicologia , Inquéritos e Questionários/normas , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Acidente Vascular Cerebral/complicações , Suíça , Traduções , Extremidade Superior/fisiopatologia
12.
Sensors (Basel) ; 20(8)2020 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-32344692

RESUMO

Event related potentials (ERPs) provide insight into the neural activity generated in response to motor, sensory and cognitive processes. Despite the increasing use of ERP data in clinical research little is known about the reliability of human manual ERP labelling methods. Intra-rater and inter-rater reliability were evaluated in five electroencephalography (EEG) experts who labelled the peak negativity of averaged movement related cortical potentials (MRCPs) derived from thirty datasets. Each dataset contained 50 MRCP epochs from healthy people performing cued voluntary or imagined movement, or people with stroke performing cued voluntary movement. Reliability was assessed using the intraclass correlation coefficient and standard error of measurement. Excellent intra- and inter-rater reliability was demonstrated in the voluntary movement conditions in healthy people and people with stroke. In comparison reliability in the imagined condition was low to moderate. Post-hoc secondary epoch analysis revealed that the morphology of the signal contributed to the consistency of epoch inclusion; potentially explaining the differences in reliability seen across conditions. Findings from this study may inform future research focused on developing automated labelling methods for ERP feature extraction and call to the wider community of researchers interested in utilizing ERPs as a measure of neurophysiological change or in the delivery of EEG-driven interventions.


Assuntos
Potenciais Evocados/fisiologia , Acidente Vascular Cerebral/fisiopatologia , Adulto , Idoso , Intervalos de Confiança , Eletroencefalografia , Processamento Eletrônico de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
13.
BMC Public Health ; 19(1): 1384, 2019 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-31660929

RESUMO

BACKGROUND: The CHEERS is a self-administered tool to measure gaps, weaknesses, and strengths of an early childhood education and care (ECEC) centre-based nutrition and physical activity environment. ECEC settings have the potential to profoundly influence early dietary and physical activity behaviours. Content validation of the CHEERS tool has been previously reported. The purpose of this study was to develop reliability and validity evidence for the CHEERS audit tool and the proposed subscales of food served, healthy eating environment, program planning, and physical activity environment in ECEC centre-based programs. METHODS: This cross-sectional study consisted of 2 phases: Phase 1 included inter-, intra-rater and Cronbach's α. A subset of this sample was invited to participate in a second survey (Trial 2) for intra-rater assessment within 3 weeks of completing the first survey (Trial 1). Phase 2 included concurrent validity assessment between a nutrition expert and the ECEC director using within a one-week period. RESULTS: One hundred two directors and 85 educators (total of 187) returned the survey. Of these, there were 75 matched pairs for inter-rater reliability analysis providing a CHEERS ICC score of 0.59 and ICC scores ranging from 0.40 to 0.58 for the subscales. The ICC for intra-rater reliability of the CHEERS score was 0.81 for 40 participants completing the survey a second time and a range of 0.72 to 0.79 for the subscales. The CHEERS tool demonstrated very good internal consistency (α = 0.91) and α scores ranging from 0.73 to 0.79 for the subscales. In phase 2, concurrent validation was ICC = 0.65 (n = 30) CHEERS scores with a range of 0.42 to 0.69 for the subscales. CONCLUSIONS: This study provides evidence of inter-, intra-rater reliability, internal consistency, and concurrent validity of an environmental assessment audit tool to assess the nutrition and physical activity environment of ECEC centre-based programs. The results demonstrate that the self-administered CHEERS instrument is stable overtime and between evaluators at the same ECEC centre. The scores obtained with CHEERS self-administered audit tool are reasonably accurate compared to an expert rater (dietitian) assessment. This study adds additional support to establishing the psychometric soundness of the CHEERS tool.


Assuntos
Cuidado da Criança/organização & administração , Dieta Saudável , Meio Ambiente , Exercício Físico , Inquéritos e Questionários , Adolescente , Adulto , Alberta , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
14.
Digestion ; 97(2): 183-194, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29320766

RESUMO

BACKGROUND/AIMS: To evaluate the usefulness of linked color imaging (LCI) and blue LASER imaging (BLI) in Barrett's esophagus (BE) compared with white light imaging (WLI). METHODS: Five expert and trainee endoscopists compared WLI, LCI, and BLI images obtained from 63 patients with short-segment BE. Physicians assessed visibility as follows: 5 (improved), 4 (somewhat improved), 3 (equivalent), 2 (somewhat decreased), and one (decreased). Scores were evaluated to assess visibility. The inter- and intra-rater reliability (intra-class correlation coefficient) of image assessments were also evaluated. Images were objectively evaluated based on L* a* b* color values and color differences (ΔE*) in a CIELAB color space system. RESULTS: Improved visibility compared with WLI was achieved for LCI: 44.4%, BLI: 0% for all endoscopists; LCI: 55.6%, BLI: 1.6% for trainees; and LCI: 47.6%, BLI: 0% for experts. The visibility score of trainees compared with experts was significantly higher for LCI (p = 0.02). Intra- and inter-rater reliability ratings for LCI compared with WLI were "moderate" for trainees, and "moderate-substantial" for experts. The ΔE* revealed statistically significant differences between WLI and LCI. CONCLUSION: LCI improved the visibility of short-segment BE compared with WLI, especially for trainees, when evaluated both subjectively and objectively.


Assuntos
Esôfago de Barrett/diagnóstico por imagem , Esofagoscopia/métodos , Esôfago/diagnóstico por imagem , Imagem de Banda Estreita/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cor , Esôfago/patologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
15.
BMC Infect Dis ; 17(1): 298, 2017 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-28438117

RESUMO

BACKGROUND: African pouched rats sniffing sputum samples provided by local clinics have significantly increased tuberculosis case findings in Tanzania and Mozambique. The objective of this study was to determine the reproducibility of rat results. METHODS: Over an 18-month period 11,869 samples were examined by the rats. Intra-rater reliability was assessed through Yule's Q. Inter-rater reliability was assessed with Krippendorff's alpha. RESULTS: Intra-rater reliability was high, with a mean Yule's Q of 0.9. Inter-rater agreement was fair, with Krippendorf's alpha ranging from 0.15 to 0.45. Both Intra- and Inter-rater reliability was independent of the sex of the animals, but they were positively correlated with age. Both intra- and inter-rater agreement was lowest for samples designated as smear-negative by the clinics. CONCLUSION: Overall, the reproducibility of tuberculosis detection rat results was fair and diagnostic results were therefore independent of the rats used.


Assuntos
Mycobacterium tuberculosis/isolamento & purificação , Olfato/fisiologia , Tuberculose/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Ratos , Reprodutibilidade dos Testes , Escarro/microbiologia , Tuberculose/microbiologia , Adulto Jovem
16.
Public Health Nutr ; 20(2): 200-209, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27629790

RESUMO

OBJECTIVE: The current study assessed whether home-based data collection by trained data collectors can produce high-quality physical measurement data in young children. DESIGN: The study assessed the quality of intra-examiner measurements of blood pressure, pulse rate and anthropometric dimensions using intra-examiner reliability and intra-examiner technical error of measurement (TEM). SETTING: Non-clinical, primarily private homes of National Children's Study participants in twenty-two study locations across the USA. SUBJECTS: Children in four age groups: 5-7 months (n 91), 11-16 months (n 393), 23-28 months (n 1410) and 35-40 months (n 800). RESULTS: Absolute TEM ranged in value from 0·09 to 16·21, varying widely by age group and measure, as expected. Relative TEM spanned from 0·27 to 13·71 across age groups and physical measures. Reliabilities for anthropometric measurements by age group and measure ranged from 0·46 to >0·99 with most exceeding 0·90, suggesting that the large majority of anthropometric measures can be collected in a home-based setting on young children by trained data collectors. Reliabilities for blood pressure and pulse rate measurements by age group ranged from 0·21 to 0·74, implying these are less reliably measured with young children when taken in the data collection context described here. CONCLUSIONS: Reliability estimates >0·95 for weight, length, height, and thigh, waist and head circumference, and >0·90 for triceps and subscapular skinfolds, indicate that these measures can be collected in the field by trained data collectors without compromising data quality. These estimates can be used for interim evaluations of data collector training and measurement protocols.


Assuntos
Antropometria/métodos , Monitorização Ambulatorial da Pressão Arterial/métodos , Coleta de Dados/métodos , Determinação da Frequência Cardíaca/métodos , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estados Unidos
17.
Int Wound J ; 14(2): 420-429, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27218422

RESUMO

This test-retest pilot study investigated the intra-rater reliability and reproducibility of non-invasive technologies to objectively quantify morphological (colour, thickness and elasticity) and physiological (transepidermal water loss (TEWL), hydration, sebum and pH) skin properties in an aged care population. Three consecutive measurements were taken from five anatomical skin sites, with the mean of each measurement calculated. The intra-class correlation coefficient (ICC) and the standard error of measurement (SEM) were used to examine the intra-rater reliability and reproducibility of measurements. Non-invasive technologies in this study showed almost perfect reliability for ultrasound measurements of the subepidermal low echogenicity band (SLEB) (ρ = 0·95-0·99) and skin thickness (ρ = 0·95-0·99) across all sites. The ICC was substantial to almost perfect for pH (ρ = 0·76-0·88) and viscoelasticity (ρ = 0·67-0·91) across all sites. Hydration (ρ = 0·53-0·85) and skin retraction (ρ = 0·57-0·99) measurements ranged from moderate to almost perfect across all sites. TEWL and elasticity were substantial to almost perfect across four sites. Casual sebum levels and most colour parameters showed poor ICC. The use of non-invasive technologies in this study provided an objective and reliable means for quantifying ageing skin and may offer future studies a valuable option for assessing skin tear risk.


Assuntos
Envelhecimento/fisiologia , Fenômenos Biomecânicos/fisiologia , Elasticidade/fisiologia , Fenômenos Fisiológicos da Pele , Pele/anatomia & histologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes
18.
J Man Manip Ther ; 25(4): 201-207, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28912632

RESUMO

OBJECTIVES: Joint mobilizations are often quantified using a 4-point grading system based on the physiotherapist's detection of resistance. It is suggested that the initial resistance to joint mobilizations is imperceptible to physiotherapists, but that at some point through range becomes perceptible, a point termed R1. Grades of mobilization traditionally hinge around this concept and are performed either before or after R1. Physiotherapists, however, show poor reliability in applying grades of mobilization. The definition of R1 is ambiguous and dependent on the skills of the individual physiotherapist. The aim of this study is to test a revised grading system where R1 is considered at the beginning of range, and the entire range, as perceived by the physiotherapists maximum force application, is divided into three, creating 3 grades of mobilization. METHOD: Thirty-two post-registration physiotherapists and nineteen pre-registration students assessed end of range (point R2) and then applied 3 grades of AP mobilizations, over the talus, in an asymptomatic models ankle. Vertical forces were recorded through a force platform. Intra-class Correlation Coefficients, Standard Error of Measurement, and Minimal Detectable Change were calculated to explore intra-rater reliability on intra-day and inter-day testing. T-tests determined group differences. RESULTS: Intra-rater reliability was excellent for intra-day testing (ICC 0.96-0.97), and inter-day testing (ICC 0.85-0.93). No statistical difference was found between pre- and post-registration groups. DISCUSSION: Standardizing the definition of grades of mobilization, by moving R1 to the beginning of range and separating grades into thirds, results in excellent intra-rater reliability on intra-day and inter-day tests. LEVEL OF EVIDENCE: 3b.

19.
J Phys Ther Sci ; 28(7): 2082-3, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27512269

RESUMO

[Purpose] This study investigated intra-rater reliability when using a tympanic thermometer under different self-measurement conditions. [Subjects and Methods] Ten males participated. Intra-rater reliability was assessed by comparing the values under three conditions of measurement using a tympanic thermometer. Intraclass correlation coefficients were used to assess intra-rater reliability. [Results] According to the intraclass correlation coefficient analysis, reliability could be ranked according to the conditions of measurement. [Conclusion] The results showed that self-measurement of body temperature is more precise when combined with common sense and basic education about the anatomy of the eardrum.

20.
J Mov Disord ; 17(2): 150-157, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38098205

RESUMO

OBJECTIVE: To examine the inter- and intra-rater reliability of the pull test in patients with Parkinson's disease (PD) using the extracted pull force. METHODS: In this inter- and intra-rater reliability study, two raters performed a pull test on 30 patients with PD. The pull force was quantified using inertial sensors attached to the rater's right hand and the patient's lower trunk. In this study, the pull force was calculated as an extracted three-dimensional vector quantity, the resultant acceleration, and was expressed in m/s2. Inter- and intra-rater reliabilities were analyzed using the interclass correlation coefficient (ICC) for the pull force and Cohen's weighted kappa (κw) for the pull test score. Furthermore, Bland-Altman analysis was used to investigate systematic errors. RESULTS: The inter- and intra-rater reliability of the pull force was very poor (ICC = 0.033-0.214). Bland-Altman analysis revealed no systematic errors in the pull forces between the two test points. Conversely, κw for the pull test scores ranged from 0.763 to 0.920, indicating substantial to almost perfect agreement. CONCLUSION: The pull test score was reliable despite variations in the quantified pull force for inter- and intra-rater reliability. Our findings suggest that the pull test is a robust tool for evaluating postural instability in patients with PD and that the pull force probably does not affect scoring performance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA