Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.572
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
NMR Biomed ; : e5213, 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-39032076

RESUMO

We aim to explore the feasibility of head and neck time-of-flight (TOF) magnetic resonance angiography (MRA) at ultra-low-field (ULF). TOF MRA was conducted on a highly simplified 0.05 T MRI scanner with no radiofrequency (RF) and magnetic shielding. A flow-compensated three-dimensional (3D) gradient echo (GRE) sequence with a tilt-optimized nonsaturated excitation RF pulse, and a flow-compensated multislice two-dimensional (2D) GRE sequence, were implemented for cerebral artery and vein imaging, respectively. For carotid artery and jugular vein imaging, flow-compensated 2D GRE sequences were utilized with venous and arterial blood presaturation, respectively. MRA was performed on young healthy subjects. Vessel-to-background contrast was experimentally observed with strong blood inflow effect and background tissue suppression. The large primary cerebral arteries and veins, carotid arteries, jugular veins, and artery bifurcations could be identified in both raw GRE images and maximum intensity projections. The primary brain and neck arteries were found to be reproducible among multiple examination sessions. These preliminary experimental results demonstrated the possibility of artery TOF MRA on low-cost 0.05 T scanners for the first time, despite the extremely low MR signal. We expect to improve the quality of ULF TOF MRA in the near future through sequence development and optimization, ongoing advances in ULF hardware and image formation, and the use of vascular T1 contrast agents.

2.
J Magn Reson Imaging ; 59(3): 797-811, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37589377

RESUMO

Perforator flap magnetic resonance angiography (MRA) has emerged as a widely accepted and preferred modality for perforator flap mapping at several institutions. Autologous perforator flaps are a type of reconstructive microsurgical technique that involves transferring skin and fat from one part of the patient's body to another to replace tissue lost due to trauma, cancer resection, or other reasons. Autologous perforator flaps are based on a specific perforating blood vessel perfusing the transferred tissue. Hence, the surgery relies on the precise identification and mapping of perforating vessels to ensure successful outcomes. With its superior soft tissue contrast and multiplanar imaging capabilities, MRA has shown great potential in providing accurate and detailed visualization of perforator anatomy, size, and course. This review article summarizes the current literature on perforator flap MRA, including its technical considerations, imaging protocols, postprocessing, and reporting, specifically for autologous breast reconstructions. The advantages and limitations of MRA in evaluating perforator flaps are discussed, including its role in preoperative planning, intraoperative guidance, and postoperative assessment. Anatomy, brief surgical technique, specific technical modifications, and reporting of most commonly performed autologous breast flaps are described. Recent advancements in Perforator flap surgery and MRA techniques are discussed. Additionally, we examine the emerging role of artificial intelligence and machine learning in improving the accuracy and efficiency of perforator flap MRA interpretation. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 5.


Assuntos
Mamoplastia , Retalho Perfurante , Humanos , Angiografia por Ressonância Magnética/métodos , Inteligência Artificial , Artérias Epigástricas/patologia , Mamoplastia/métodos
3.
J Magn Reson Imaging ; 59(2): 587-598, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37220191

RESUMO

BACKGROUND: The delineation of brain arteriovenous malformations (bAVMs) is crucial for subsequent treatment planning. Manual segmentation is time-consuming and labor-intensive. Applying deep learning to automatically detect and segment bAVM might help to improve clinical practice efficiency. PURPOSE: To develop an approach for detecting bAVM and segmenting its nidus on Time-of-flight magnetic resonance angiography using deep learning methods. STUDY TYPE: Retrospective. SUBJECTS: 221 bAVM patients aged 7-79 underwent radiosurgery from 2003 to 2020. They were split into 177 training, 22 validation, and 22 test data. FIELD STRENGTH/SEQUENCE: 1.5 T, Time-of-flight magnetic resonance angiography based on 3D gradient echo. ASSESSMENT: The YOLOv5 and YOLOv8 algorithms were utilized to detect bAVM lesions and the U-Net and U-Net++ models to segment the nidus from the bounding boxes. The mean average precision, F1, precision, and recall were used to assess the model performance on the bAVM detection. To evaluate the model's performance on nidus segmentation, the Dice coefficient and balanced average Hausdorff distance (rbAHD) were employed. STATISTICAL TESTS: The Student's t-test was used to test the cross-validation results (P < 0.05). The Wilcoxon rank test was applied to compare the median for the reference values and the model inference results (P < 0.05). RESULTS: The detection results demonstrated that the model with pretraining and augmentation performed optimally. The U-Net++ with random dilation mechanism resulted in higher Dice and lower rbAHD, compared to that without that mechanism, across varying dilated bounding box conditions (P < 0.05). When combining detection and segmentation, the Dice and rbAHD were statistically different from the references calculated using the detected bounding boxes (P < 0.05). For the detected lesions in the test dataset, it showed the highest Dice of 0.82 and the lowest rbAHD of 5.3%. DATA CONCLUSION: This study showed that pretraining and data augmentation improved YOLO detection performance. Properly limiting lesion ranges allows for adequate bAVM segmentation. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Aprendizado Profundo , Malformações Arteriovenosas Intracranianas , Humanos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Malformações Arteriovenosas Intracranianas/cirurgia , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso
4.
Am J Med Genet A ; 194(3): e63467, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37933544

RESUMO

A small number of case reports have documented a link between atlantoaxial dislocation (AAD) and vertebral artery dissection (VAD), but this association has never been described in patients with hereditary connective tissue disorders. We present a case of an 18-year-old female patient, diagnosed with Marfan syndrome since the age of one, who underwent brain MRA for intracranial aneurysm screening revealing tortuosity of the internal carotid and vertebral arteries as well as atlantoaxial dislocation. Since the patient was asymptomatic, a wait-and-see approach was chosen, but a follow-up MRA after 18 months showed the appearance of a dissecting pseudoaneurysm of the V3 segment of the left vertebral artery. Despite the patient being still asymptomatic, it was decided to proceed with C1-C2 stabilization to prevent further vascular complications. Follow-up imaging showed realignment of the atlantoaxial joint and reduction of the dissecting pseudoaneurysm of the left vertebral artery. In our patient, screening MRA has led to the discovery of asymptomatic arterial and skeletal abnormalities which, if left untreated, might have led to severe cerebrovascular complications. Therefore, AAD correction or close monitoring with MRA should be provided to MFS patients with this craniovertebral junction anomaly, even if asymptomatic.


Assuntos
Falso Aneurisma , Aneurisma Intracraniano , Luxações Articulares , Síndrome de Marfan , Dissecação da Artéria Vertebral , Feminino , Humanos , Adolescente , Dissecação da Artéria Vertebral/diagnóstico , Dissecação da Artéria Vertebral/diagnóstico por imagem , Síndrome de Marfan/complicações , Síndrome de Marfan/diagnóstico , Falso Aneurisma/diagnóstico , Falso Aneurisma/diagnóstico por imagem , Artéria Vertebral/diagnóstico por imagem , Artéria Vertebral/anormalidades , Luxações Articulares/complicações , Luxações Articulares/diagnóstico
5.
Am J Med Genet A ; 194(3): e63465, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37916856

RESUMO

Loeys-Dietz syndrome (LDS) is an autosomal connective tissue disorder commonly presenting with hypertelorism, bifid uvula, aortic aneurysms, and arterial tortuosity. The aim of the present study was to investigate differences in tortuosity index (TI) between genotypes of LDS, possible progression over time and its use as an adjunctive prognostic tool alongside aortic dimensions to aid timely surgical planning in pediatric patients. A retrospective observational study of pediatric LDS patients referred to our center (November 2012-February 2021) was conducted. Using magnetic resonance angiography (MRA) with 3D maximum intensity projection volume-rendered angiogram, arterial TI was measured. Twenty three patients had genetically confirmed LDS with at least one head and neck MRA and 19 had no less than one follow-up MRA available. All patients presented arterial tortuosity. Patients with TGFBR2 variants had greater values of TI compared to patients with TGFB2 variants (p = 0.041). For patients who did not undergo surgery (n = 18), z-scores at the level of the sinus of Valsalva showed a significant correlation with vertebral TI (rs = 0.547). There was one death during follow-up. This study demonstrates that patients with LDS and TGFBR2 variants have greater values of TI than patients with TGFB2 variants and that greatest values of TI are associated with increased aortic root z-scores. Furthermore, as TI decreases over time, less frequent neuroimaging follow-up can be considered. Nevertheless, additional studies are needed to better define more accurate risk stratification and long-term surveillance in these patients.


Assuntos
Artérias/anormalidades , Instabilidade Articular , Síndrome de Loeys-Dietz , Dermatopatias Genéticas , Malformações Vasculares , Criança , Humanos , Receptor do Fator de Crescimento Transformador beta Tipo II/genética , Síndrome de Loeys-Dietz/diagnóstico , Síndrome de Loeys-Dietz/genética , Síndrome de Loeys-Dietz/complicações , Dermatopatias Genéticas/complicações , Aorta/patologia
6.
Muscle Nerve ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38948953

RESUMO

INTRODUCTION/AIMS: Despite being a prominent feature of myasthenia gravis (MG), extraocular muscle (EOM) has received little attention in clinical research. The aim of this study was to examine EOM volume in patients with MG and controls using time-of-flight magnetic resonance angiography (TOF-MRA). METHODS: EOM volumes (overall and individual rectus muscles) were calculated using TOF-MRA images and compared between MG patients (including subgroups) and controls. The correlation between EOM volume and disease duration was examined. Predictive equations for the selected parameters were developed using multiple linear regression analysis. RESULTS: EOM volume was lower in MG patients than controls, especially in MG patients with ophthalmoparesis (MG-O). MG-O exhibited a moderate negative correlation between EOM volume and disease duration. Multiple linear regression showed that disease duration and EOM status (ophthalmoparesis or not) account for 48.4% of EOM volume. DISCUSSION: Patients with MG show atrophy of the EOMs, especially those with ophthalmoparesis and long disease duration.

7.
Eur Radiol ; 34(4): 2689-2698, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37804340

RESUMO

OBJECTIVES: Visualizing left atrial anatomy including the pulmonary veins (PVs) is important for planning the procedure of pulmonary vein isolation with ablation in patients with atrial fibrillation (AF). The aims of our study are to investigate the feasibility of the 3D whole-heart bright-blood and black-blood phase-sensitive (BOOST) inversion recovery sequence in patients with AF scheduled for ablation or electro-cardioversion, and to analyze the correlation between image quality and heart rate and rhythm of patients. METHODS: BOOST was performed for assessing PVs both with T2 preparation pre-pulse (T2prep) and magnetization transfer preparation (MTC) in 45 patients with paroxysmal or permanent AF scheduled for ablation or electro-cardioversion. Image quality analyses were performed by two independent observers. Qualitative assessment was made using the Likert scale; for quantitative analysis, signal to noise ratios (SNR) and contrast to noise ratios (CNR) were calculated for each PV. Heart rate and rhythm were analyzed based on standard 12-lead ECGs. RESULTS: All MTC-BOOST acquisitions achieved diagnostic quality in the PVs, while a significant proportion of T2prep-BOOST images were not suitable for assessing PVs. SNR and CNR values of the MTC-BOOST bright-blood images were higher if patients had sinus rhythm. We found a significant or nearly significant negative correlation between heart rate and the SNR and CNR values of MTC-BOOST bright-blood images. CONCLUSION: 3D whole-heart MTC-BOOST bright-blood imaging is suitable for visualizing the PVs in patients with AF, producing diagnostic image quality in 100% of cases. However, image quality was influenced by heart rate and rhythm. CLINICAL RELEVANCE STATEMENT: The novel 3D whole-heart BOOST CMR sequence needs no contrast administration and is performed during free-breathing; therefore, it is easy to use for a wide range of patients and is suitable for visualizing the PVs in patients with AF. KEY POINTS: • The applicability of the novel 3D whole-heart bright-blood and black-blood phase-sensitive sequence to pulmonary vein imaging in clinical practice is unknown. • Magnetization transfer-bright-blood and black-blood phase-sensitive imaging is suitable for visualizing the pulmonary veins in patients with atrial fibrillation with excellent or good image quality. • Bright-blood and black-blood phase-sensitive cardiac magnetic resonance sequence is easy to use for a wide range of patients as it needs no contrast administration and is performed during free-breathing.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos de Viabilidade , Átrios do Coração/diagnóstico por imagem , Eletrocardiografia , Imageamento por Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos
8.
Eur Radiol ; 34(3): 1411-1421, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37646808

RESUMO

OBJECTIVES: This study evaluated the collateral map's ability to predict lesion growth and penumbra after acute anterior circulation ischemic strokes. METHODS: This was a retrospective analysis of selected data from a prospectively collected database. The lesion growth ratio was the ratio of the follow-up lesion volume to the baseline lesion volume on diffusion-weighted imaging (DWI). The time-to-maximum (Tmax)/DWI ratio was the ratio of the baseline Tmax > 6 s volume to the baseline lesion volume. The collateral ratio was the ratio of the hypoperfused lesion volume of the phase_FU (phase with the hypoperfused lesions most approximate to the follow-up DWI lesion) to the hypoperfused lesion volume of the phase_baseline of the collateral map. Multiple logistic regression analyses were conducted to identify independent predictors of lesion growth. The concordance correlation coefficients of Tmax/DWI ratio and collateral ratio for lesion growth ratio were analyzed. RESULTS: Fifty-two patients, including twenty-six males (mean age, 74 years), were included. Intermediate (OR, 1234.5; p < 0.001) and poor collateral perfusion grades (OR, 664.7; p = 0.006) were independently associated with lesion growth. Phase_FUs were immediately preceded phases of the phase_baselines in intermediate or poor collateral perfusion grades. The concordance correlation coefficients of the Tmax/DWI ratio and collateral ratio for the lesion growth ratio were 0.28 (95% CI, 0.17-0.38) and 0.88 (95% CI, 0.82-0.92), respectively. CONCLUSION: Precise prediction of lesion growth and penumbra can be possible using collateral maps, allowing for personalized application of recanalization treatments. Further studies are needed to generalize the findings of this study. CLINICAL RELEVANCE STATEMENT: Precise prediction of lesion growth and penumbra can be possible using collateral maps, allowing for personalized application of recanalization treatments. KEY POINTS: • Cell viability in cerebral ischemia due to proximal arterial steno-occlusion mainly depends on the collateral circulation. • The collateral map shows salvageable brain extent, which can survive by recanalization treatments after acute anterior circulation ischemic stroke. • Precise estimation of salvageable brain makes it possible to make patient-specific treatment decision.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Masculino , Humanos , Idoso , AVC Isquêmico/complicações , AVC Isquêmico/patologia , Estudos Retrospectivos , Isquemia Encefálica/complicações , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Circulação Colateral , Circulação Cerebrovascular
9.
Eur Radiol ; 34(7): 4686-4696, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38133674

RESUMO

OBJECTIVES: To investigate the feasibility of non-contrast-enhanced MR angiography (NCE-MRA) in evaluating the morphology and blood supply of left gastric vein (LGV) in patients with gastroesophageal varices. METHODS: Between March 2021 and October 2022, patients with gastroesophageal varices and who underwent NCE-MRA were retrospectively reviewed. In order to evaluate the blood supply of LGV, superior mesenteric vein (SMV) and splenic vein (SV) were visualized separately by using inflow-sensitive inversion recovery sequence. Two radiologists independently assessed the image quality, determined the origination and the blood supply of LGV, and measured the diameter of LGV. The origination and diameter of LGV were compared between NCE-MRA and contrast-enhanced CT. Differences in blood supply were compared between LGVs with different originations. RESULTS: A total of 53 patients were enrolled in this study and the image quality was categorized as good or excellent in 52 patients. No significant differences were observed in visualizing the origination and the diameter of LGV between NCE-MRA and contrast-enhanced CT (p > .05). The blood supply of LGV was related to its origination (p < .001). Most LGVs with SV origination were supplied by SV. If LGV was originated from the portal vein (PV), about 70% of them were supplied by both SV and SMV. Compared with LGVs with SV origination, LGVs with PV origination showed more chance to receive blood from SMV (p < .001). CONCLUSION: Non-contrast-enhanced MR angiography appears to be a reliable technique in evaluating the morphology and blood supply of LGV in patients with gastroesophageal varices. CLINICAL RELEVANCE STATEMENT: Non-contrast-enhanced MR angiography provides valuable information for the management of gastroesophageal varices. Especially, it benefits patients with renal insufficiency. KEY POINTS: • Non-contrast-enhanced MR angiography using inflow-sensitive inversion recovery technique can be used for evaluating not only morphology as CT but also blood supply of left gastric vein. • The blood supply of left gastric vein is related to its origination and left gastric vein with portal vein origination shows more chance to receive blood from superior mesenteric vein.


Assuntos
Varizes Esofágicas e Gástricas , Estudos de Viabilidade , Angiografia por Ressonância Magnética , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Varizes Esofágicas e Gástricas/diagnóstico por imagem , Estudos Retrospectivos , Angiografia por Ressonância Magnética/métodos , Idoso , Adulto , Estômago/irrigação sanguínea , Estômago/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Veia Esplênica/diagnóstico por imagem , Veias Mesentéricas/diagnóstico por imagem , Meios de Contraste
10.
Eur Radiol ; 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38311702

RESUMO

OBJECTIVES: Patients with an unruptured intracranial aneurysm (UIA) may experience scanxiety around follow-up imaging. We studied the prevalence and temporal pattern of scanxiety, and compared quality of life (QoL) outcomes in patients with and without scanxiety. METHODS: We performed a prospective cohort study in a tertiary referral center in the Netherlands between October 2021 and November 2022. We sent questionnaires to patients ≥ 18 years old undergoing UIA follow-up imaging 4 weeks before (T1), immediately after (T2), and 6 weeks after the scan (T3) to assess health-related QoL (HRQoL) and emotional functioning. At T3, we also assessed scanxiety with a purpose-designed questionnaire. We compared differences in QoL outcomes between respondents with and without scanxiety using mixed models. RESULTS: Of 158 eligible patients, 106 (67%) participated (mean age 61 years ± 11 [standard deviation], 84 women). Sixty of the 91 respondents (66%) who completed the purpose-designed questionnaire experienced scanxiety. Of the 49 respondents who experienced scanxiety after the scan, it resolved in 22 (45%) within a day after receiving the radiology report. HRQoL did not differ between respondents with or without scanxiety. Emotional functioning was worse for respondents with scanxiety (mean Hospital Anxiety and Depression Scale sum score difference at T1, 3.6 [95% CI, 0.9-6.3]; T2, 4.1 [95% CI, 1.5-6.8]; and T3, 4.0 [95% CI, 1.5-6.5]). CONCLUSIONS: Two-thirds of the respondents experienced scanxiety around follow-up imaging, which often resolved within a day after receiving results. Patients with scanxiety had similar HRQoL but worse emotional functioning compared to patients without scanxiety. The time between the scan and receiving the results should be minimized to decrease the duration of scanxiety. CLINICAL RELEVANCE STATEMENT: We showed that scanxiety is common in UIA patients, and negatively associated with emotional functioning. Since scanxiety often disappears immediately after receiving the radiology report, it should be communicated to the patient as early as possible to alleviate patients' distress. KEY POINTS: • Many patients with an unruptured intracranial aneurysm experience emotional distress around follow-up imaging, termed "scanxiety." • Patients with scanxiety had worse emotional functioning compared to patients without scanxiety. • Scanxiety often resolved within a day after receiving the radiology report.

11.
Eur Radiol ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38713277

RESUMO

OBJECTIVES: Comprehensive evaluation of lower-extremity varicose veins (VVs) in patients with diabetes is crucial for treatment strategizing. The study aims to assess the feasibility of using ferumoxytol-enhanced MR venography (FE-MRV) for lower-extremity venous mapping and the detection of VVs in patients with diabetes. MATERIALS AND METHODS: As part of a phase II clinical trial of a generic brand of ferumoxytol, documented patients with diabetes were enrolled and underwent FE-MRV on a 3-Τ MRI system. Two observers assessed FE-MRV images for image quality, signal intensity ratio (SIR), perforator (PV) diameter, and luminal signal uniformity in deep-to-superficial venous networks with the assessment of intra- and inter-rater reliability. FE-MRV was used to detect lower-extremity VVs. RESULTS: Eleven patients underwent FE-MRV without adverse events. The average image quality, as scored by the two observers who assessed 275 venous segments, was 3.4 ± 0.6. Two observers strongly agreed on image quality (κ = 0.90) and SIR measurements (interclass correlation coefficient [ICC]: 0.72) and had good agreement on PV diameter (ICC: 0.64). FE-MRV revealed uniform luminal signals in deep and saphenous venous networks (0.13 ± 0.05 vs 0.08 ± 0.03). Below-knee segments exhibited a significantly higher heterogeneity index than above-knee (p = 0.039) segments. Superficial VVs were observed in 55% (12/22) of legs in 64% (7/11) of patients. Calf muscle VVs were present in 64% (14/22) of legs in 9 patients. CONCLUSION: FE-MRV safely and robustly mapped entire lower-extremity venous networks, enabling the detection and pre-treatment evaluation of both superficial, and deep VVs in patients with diabetes. CLINICAL RELEVANCE STATEMENT: Ferumoxytol-enhanced magnetic resonance venography offers a "one-stop" imaging strategy for the detection and pre-operative evaluation of both superficial and deep VVs in diabetic patients. KEY POINTS: Diabetic patients with VVs are at a higher risk of ulcer-related complications. FE-MRV allowed rapid and comprehensive visualization of the lower-limb venous networks and abdominopelvic veins in diabetic patients. This technique allowed for the detection of superficial and deep VVs in diabetic patients before the development of severe peripheral artery disease.

12.
J Cardiovasc Magn Reson ; 26(1): 100992, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38211655

RESUMO

BACKGROUND: The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA). METHODS: Patients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained. RESULTS: Mean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR). CONCLUSION: Mapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases.


Assuntos
Aorta Torácica , Doenças da Aorta , Meios de Contraste , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Variações Dependentes do Observador , Valor Preditivo dos Testes , Humanos , Reprodutibilidade dos Testes , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Aorta Torácica/diagnóstico por imagem , Idoso , Meios de Contraste/administração & dosagem , Doenças da Aorta/diagnóstico por imagem , Técnicas de Imagem de Sincronização Respiratória , Adulto , Fatores de Tempo , Interpretação de Imagem Assistida por Computador , Técnicas de Imagem de Sincronização Cardíaca
13.
Neuroradiology ; 66(8): 1325-1334, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38400955

RESUMO

PURPOSE: Alagille syndrome (ALGS) is a multisystem autosomal dominant disorder with highly variable expression. Intracranial arterial and venous anomalies have a reported prevalence of 30-40% and can increase the risk of stroke by 16%. Few reports document the frequency and evolution of cerebrovascular abnormalities (CVAs) in children with ALGS. We aimed to define the spectrum, frequency, and evolution of CVAs in a series of children with ALGS using magnetic resonance angiography (MRA). METHODS: We conducted a single-center, retrospective study in a large tertiary pediatric hospital. CVAs were grouped into 4 categories: 1) Stenosis or narrowing; 2) Aneurysms and ectasias; 3) Tortuosity; and 4) Vascular anomalies and anatomical variants. RESULTS: Thirty-two children met the inclusion criteria. The median age at initial diagnosis was 6 (3.8-10.3) years. Thirteen (40%) had follow-up MRI at a mean of 55 (31.5-66) months. Eighteen (56%) had CVAs; the most frequent fell into group 1 (n = 12, 37.5%). CVAs were stable over time, except for one patient with Moyamoya arteriopathy (MMA). One patient developed a transient ischemic attack secondary to an embolic event. Three (9.3%) had microhemorrhages at the initial diagnosis secondary to Tetralogy of Fallot. Another patient had recurrent subdural hematomas of unknown cause. CONCLUSION: CVAs were stable except in the presence of MMA. Vascular strokes, which are reported in older patients with ALGS, were not a common feature in children under 16 years of age, either at presentation or over the 31.5-66 month follow-up period.


Assuntos
Síndrome de Alagille , Angiografia por Ressonância Magnética , Humanos , Síndrome de Alagille/diagnóstico por imagem , Síndrome de Alagille/complicações , Masculino , Feminino , Criança , Pré-Escolar , Estudos Retrospectivos , Angiografia por Ressonância Magnética/métodos , Transtornos Cerebrovasculares/diagnóstico por imagem
14.
BMC Med Imaging ; 24(1): 136, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844842

RESUMO

BACKGROUND: To develop and validate a peritumoral vascular and intratumoral radiomics model to improve pretreatment predictions for pathologic complete responses (pCRs) to neoadjuvant chemoradiotherapy (NAC) in patients with triple-negative breast cancer (TNBC). METHODS: A total of 282 TNBC patients (93 in the primary cohort, 113 in the validation cohort, and 76 in The Cancer Imaging Archive [TCIA] cohort) were retrospectively included. The peritumoral vasculature on the maximum intensity projection (MIP) from pretreatment DCE-MRI was segmented by a Hessian matrix-based filter and then edited by a radiologist. Radiomics features were extracted from the tumor and peritumoral vasculature of the MIP images. The LASSO method was used for feature selection, and the k-nearest neighbor (k-NN) classifier was trained and validated to build a predictive model. The diagnostic performance was assessed using the ROC analysis. RESULTS: One hundred of the 282 patient (35.5%) with TNBC achieved pCRs after NAC. In predicting pCRs, the combined peritumoral vascular and intratumoral model (fusion model) yields a maximum AUC of 0.82 (95% confidence interval [CI]: 0.75, 0.88) in the primary cohort, a maximum AUC of 0.67 (95% CI: 0.57, 0.76) in the internal validation cohort, and a maximum AUC of 0.65 (95% CI: 0.52, 0.78) in TCIA cohort. The fusion model showed improved performance over the intratumoral model and the peritumoral vascular model, but not significantly (p > 0.05). CONCLUSION: This study suggested that combined peritumoral vascular and intratumoral radiomics model could provide a non-invasive tool to enable prediction of pCR in TNBC patients treated with NAC.


Assuntos
Imageamento por Ressonância Magnética , Terapia Neoadjuvante , Neoplasias de Mama Triplo Negativas , Humanos , Neoplasias de Mama Triplo Negativas/diagnóstico por imagem , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Neoplasias de Mama Triplo Negativas/terapia , Neoplasias de Mama Triplo Negativas/patologia , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Resultado do Tratamento , Resposta Patológica Completa , Radiômica
15.
BMC Med Imaging ; 24(1): 10, 2024 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172706

RESUMO

BACKGROUND: Computed tomography angiography (CTA) and magnetic resonance angiography (MRA) provide accurate vascular imaging information, but their use may be contraindicated. Color Doppler ultrasonography (CDU) provides simple, safe, noninvasive, and reproducible imaging. We therefore investigated the role of preoperative CDU combined with CTA and MRA in the quantification, typing, and diagnosis of carotid body tumors (CBTs). METHODS: We retrospectively analyzed patients with CBTs categorized into group A (type I [n = 1] and type II [n = 10]) or group B (type III [n = 56]) per the intraoperative Shamblin classification. CDU, CTA, and MRA characteristics of CBTs were observed, surgical results were correlated, and the diagnostic threshold of the CBT classification was calculated. RESULTS: CBTs were usually located at the common carotid artery bifurcation, encircling the carotid artery. An increased angle was found between the internal and external carotid arteries. On CDU, CBTs primarily presented as homogeneous hypoechoic masses with clear boundaries, rich flow signals, and a high-speed, low-resistance artery-like flow spectrum. CTA showed uniform or heterogeneous marked enhancement. MRA showed mixed T1 and slightly longer T2 signals and uniform or uneven obvious enhancement. With increases in the lesion size, amount of blood transfused, and operation time, the intraoperative classification level and possibility of skull-base invasion increased. When the maximum diameter of the lesion, the volume of the tumor, the distance between the upper margin of the tumor to the mastoid and the mandibular angle were 3.10 cm, 10.15 cm3, - 3.26 cm, and 0.57 cm, respectively, the largest Youden index was the best diagnostic boundary value for Shamblin type III tumors. CONCLUSIONS: CDU combined with CTA and MRA can accurately evaluate the size and classification of CBTs.


Assuntos
Tumor do Corpo Carotídeo , Angiografia por Tomografia Computadorizada , Humanos , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Ressonância Magnética , Estudos Retrospectivos , Tumor do Corpo Carotídeo/patologia , Tumor do Corpo Carotídeo/cirurgia , Ultrassonografia Doppler em Cores/métodos
16.
Neurosurg Focus ; 56(3): E10, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38428010

RESUMO

OBJECTIVE: Spinal dural arteriovenous fistulas (SDAVFs) often go undiagnosed, leading to irreversible spinal cord dysfunction. Although digital subtraction angiography (DSA) is the gold standard for diagnosing SDAVF, DSA is invasive and operator dependent, with associated risks. MR angiography (MRA) is a promising alternative. This study aimed to evaluate the performance of MRA as an equal alternative to DSA in investigating, diagnosing, and localizing SDAVF. METHODS: Prospectively collected data from a single neurosurgeon at a large tertiary academic center were searched for SDAVFs. Eligibility criteria included any patient with a surgically proven SDAVF in whom preoperative DSA, MRA, or both had been obtained. The eligible patients formed a consecutive series, in which they were divided into DSA and MRA groups. DSA and MRA were the index tests that were compared to the surgical SDAVF outcome, which was the reference standard. Accurate diagnosis was considered to have occurred when the imaging report matched the operative diagnosis to the correct spinal level. Comparisons used a two-sample t-test for continuous variables and Fisher-Freeman-Halton's exact test for categorical variables, with p < 0.05 specifying significance. Univariate, bivariate, and multivariate analyses were conducted to investigate group associations with DSA and MRA accuracy. Positive predictive value, sensitivity, and accuracy were calculated. RESULTS: A total of 27 patients with a mean age of 63 years underwent surgery for SDAVF. There were 19 male (70.4%) and 8 female (29.6%) patients, and the mean duration of symptoms at the time of surgery was 14 months (range 2-48 months). Seventeen patients (63%) presented with bowel or bladder incontinence. Bivariate analysis of the DSA and MRA groups further revealed no significant relationships between the characteristics and accuracy of SDAVF diagnosis. MRA was found to be more sensitive and accurate (100% and 73.3%) than DSA (85.7% and 69.2%), with a subanalysis of the patients with both preoperative MRA and DSA showing that MRA had a greater positive predictive value (78.6 vs 72.7), sensitivity (100 vs 72.7), and accuracy (78.6 vs 57.1) than DSA. CONCLUSIONS: In surgically proven cases of SDAVFs, the authors determined that MRA was more accurate than DSA for SDAVF diagnosis and localization to the corresponding vertebral level. Incomplete catheterization at each vertebral level may result in the failure of DSA to detect SDAVF.


Assuntos
Malformações Vasculares do Sistema Nervoso Central , Angiografia por Ressonância Magnética , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Angiografia por Ressonância Magnética/métodos , Angiografia Digital/métodos , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/cirurgia , Medula Espinal/diagnóstico por imagem , Medula Espinal/cirurgia , Valor Preditivo dos Testes
17.
Acta Neurochir (Wien) ; 166(1): 181, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630203

RESUMO

PURPOSE: It is difficult to precisely predict indirect bypass development in the context of combined bypass procedures in moyamoya disease (MMD). We aimed to investigate the predictive value of magnetic resonance angiography (MRA) signal intensity in the peripheral portion of the major cerebral arteries for indirect bypass development in adult patients with MMD. METHODS: We studied 93 hemispheres from 62 adult patients who underwent combined direct and indirect revascularization between 2005 and 2019 and genetic analysis for RNF213 p.R4810K. The signal intensity of the peripheral portion of the major intracranial arteries during preoperative MRA was graded as a hemispheric MRA score (0-3 in the middle cerebral artery and 0-2 in the anterior cerebral and posterior cerebral arteries, with a high score representing low visibility) according to each vessel's visibility. Postoperative bypass development was qualitatively evaluated using MRA, and we evaluated the correlation between preoperative factors, including the hemispheric MRA score and bypass development, using univariate and multivariate analyses. RESULTS: A good indirect bypass was observed in 70% of the hemispheres. Hemispheric MRA scores were significantly higher in hemispheres with good indirect bypass development than in those with poor indirect bypass development (median: 3 vs. 1; p < 0.0001). Multiple logistic regression analysis revealed hemispheric MRA score as an independent predictor of good indirect bypass development (odds ratio, 2.1; 95% confidence interval, 1.3-3.6; p < 0.01). The low hemispheric MRA score (< 2) and wild-type RNF213 predicted poor indirect bypass development with a specificity of 0.92. CONCLUSION: Hemispheric MRA score was a predictive factor for indirect bypass development in adult patients who underwent a combined bypass procedure for MMD. Predicting poor indirect bypass development may lead to future tailored bypass surgeries for MMD.


Assuntos
Doença de Moyamoya , Adulto , Humanos , Doença de Moyamoya/diagnóstico por imagem , Doença de Moyamoya/cirurgia , Angiografia por Ressonância Magnética , Procedimentos Cirúrgicos Vasculares , Artéria Cerebral Média , Fatores de Transcrição , Adenosina Trifosfatases/genética , Ubiquitina-Proteína Ligases/genética
18.
Acta Neurochir (Wien) ; 166(1): 203, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38713241

RESUMO

PURPOSE: Stroke, the second leading cause of death globally, often involves ischemia in the vertebrobasilar territory. This condition is underexplored, despite significant morbidity and mortality risks. The purpose of this study is to present a case of occipital artery to V3 segment vertebral artery bypass, emphasizing the role of quantitative magnetic resonance angiography (qMRA) in assessing flow and guiding surgical intervention. METHODS: A 66-year-old man with bilateral vertebral artery occlusion presented acute symptoms. qMRA was employed to evaluate flow dynamics and determine the feasibility of a flow augmentation bypass surgery. The occipital artery to left vertebral artery bypass (OA-to-VA) was performed, utilizing an inverted hockey-stick incision and an antegrade inside-out technique. The patency of the bypass was confirmed using both Doppler probe and Indocyanine green. RESULTS: Postoperative assessments, including computed tomography angiography (CTA) and qMRA, demonstrated the patency of the bypass with improved flow in the basilar artery and left vertebral artery. The patient's condition remained stable postoperatively, with residual peripheral palsy of the left facial nerve. CONCLUSION: In conclusion, the presented case illustrates the efficacy of the OA-to-VA bypass in addressing symptomatic bilateral vertebral artery occlusion. The study underscores the pivotal role of qMRA in pre- and postoperative assessments, providing noninvasive flow quantification for diagnostic considerations and long-term follow-up in patients with vertebrobasilar insufficiency.


Assuntos
Revascularização Cerebral , Angiografia por Ressonância Magnética , Artéria Vertebral , Insuficiência Vertebrobasilar , Humanos , Masculino , Idoso , Insuficiência Vertebrobasilar/cirurgia , Insuficiência Vertebrobasilar/diagnóstico por imagem , Artéria Vertebral/cirurgia , Artéria Vertebral/diagnóstico por imagem , Revascularização Cerebral/métodos , Angiografia por Ressonância Magnética/métodos , Resultado do Tratamento
19.
Pediatr Neurosurg ; : 1-22, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38684141

RESUMO

INTRODUCTION: At our institution, revascularization after indirect moyamoya surgery is routinely evaluated using magnetic resonance angiography (MRA) rather than catheter angiography. In this paper, we review how revascularization can be visualized on axial MRA and compare its visualization on MRA to that on catheter angiography. We also compare clinical outcomes of patients followed with routine postoperative MRA with outcomes of patients followed with routine catheter angiography. METHODS: We retrospectively reviewed the records of all patients treated at our institution who underwent unilateral encephaloduroarteriosynangiosis (EDAS) and/or pial synangiosis between the ages of 1 and 21 years and between December 31, 2003, and May 1, 2021. We included patients who underwent EDAS/pial synangiosis at other hospitals as long as they met all inclusion criteria. Inclusion criteria included having a preoperative MRA within 18 months of surgery and a postoperative MRA 3-30 months after surgery. Clinical outcomes included development of postoperative stroke and transient ischemic attacks (TIAs) and changes in symptoms (improved, unchanged, or worsened), including seizures, balance issues, and headaches. Clinical outcomes were compared between patients who had routine postoperative MRA only versus those who had routine postoperative angiograms, with or without routine MRA. For each surgery, we determined the ratios of the diameters and areas of the donor vessel and the contralateral corresponding vessel, as well as the relative signal intensities of these two vessels, on preoperative and 3- to 30-month postoperative MRA. We did the same for the middle meningeal artery (MMA) ipsilateral to the donor artery and the contralateral MMA. We assessed changes from pre- to post-operation in diameter ratios, area ratios, relative signal intensity, ivy sign, and in brain perfusion on arterial spin labeled (ASL) imaging. MRI and MRA measures of revascularization and flow were compared to Matsushima grades in patients who had postoperative catheter angiograms. RESULTS: Fifty-one operations for 42 unique patients were included. There were no significant differences in the rates of postoperative strokes, postoperative TIAs, changes in symptoms, or new symptoms after surgeries evaluated by routine postoperative MRA versus catheter angiogram (p = 0.282, 1, 0.664, and 0.727, respectively). There were significant associations between greater collateralization on postoperative MRA and greater median increases in preoperative-to-postoperative ratios of donor-vessel-over-contralateral-vessel diameter (p = 0.0461), ipsilateral-MMA-over-contralateral-MMA diameter (p = 0.0135), and the summed donor and ipsilateral MMA diameters over the summed contralateral vessel diameters (p < 0.001). The median increase in the ratio of the donor vessel and contralateral corresponding vessel diameters was significantly higher for Matsushima grade A versus B (p = 0.036). The median increase in the ratio of the sum of donor and ipsilateral MMA diameters over the sum of the contralateral vessel diameters was significantly higher for improved-versus-unchanged perfusion on ASL imaging (p = 0.0074). There was a nonsignificant association between greater postoperative collateralization on MRA and Matsushima grade (p = 0.1160). CONCLUSION: Cerebral revascularization after EDAS and pial synangiosis can be evaluated on axial MRA by comparing the diameter and/or signal intensity of the donor vessel and corresponding contralateral vessel, as well as the ipsilateral and contralateral MMA, on postoperative-versus-preoperative MRA. The use of routine postoperative MRA rather than catheter angiography does not appear to negatively affect outcomes.

20.
Surg Radiol Anat ; 46(4): 523-534, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38376526

RESUMO

PURPOSE: We aimed to examine the superior mesenteric artery in detail by magnetic resonance angiography to provide an alternative to other imaging methods, to reduce the exposure time of patients and physicians to X-rays and the time spent in catheter angiography, to determine the variations, positions, and locations of the celiac trunk, and to provide detailed information for surgeons and interventional radiologists using this method. METHODS: The procedures were approved by the Kocaeli University Medical School Non-Interventional Clinical Research Ethics Committee (10.04.2023, approval number: 2021/51). MR angiography images of 185 patients with abdominal imaging in PACS (Picture Archiving Communication Systems) were retrospectively registered. The level of origin of the superior mesenteric artery according to the vertebral column, angle of origin, distance between the superior mesenteric artery and branches of the abdominal aorta, and branching pattern of the superior mesenteric artery were evaluated. Parameters were evaluated according to gender and age using SPSS version 25. RESULTS: The distance between superior mesenteric artery-inferior mesenteric artery and superior mesenteric artery-aortic bifurcation in males was higher than in females, and the difference was statistically significant. In females and the whole study group, a low, positive and significant relationship was found between age and superior mesenteric artery-sagittal angle. The most common origin site for the superior mesenteric artery, according to the vertebral column was found to be at L1 middle for males and L1 upper for females. The most common superior mesenteric artery branching pattern was classical type in both genders. CONCLUSION: Individual evaluation of the superior mesenteric artery could reduce the risks during surgical interventions, considering the relationship of the superior mesenteric artery, especially with distally located vessels, and the gender differences for the angle of origin. Furthermore, considering that interventional radiologists choose the catheter according to the angle of origin of the artery during catheter angiography procedures, individual evaluation of patients taking into account gender and age is of utmost importance.


Assuntos
Angiografia por Ressonância Magnética , Artéria Mesentérica Superior , Humanos , Masculino , Feminino , Artéria Mesentérica Superior/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Aorta Abdominal , Artéria Celíaca , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA