Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 319
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Neuroimage ; 291: 120583, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38554781

RESUMO

The data-driven approach of supervised learning methods has limited applicability in solving dipole inversion in Quantitative Susceptibility Mapping (QSM) with varying scan parameters across different objects. To address this generalization issue in supervised QSM methods, we propose a novel training-free model-based unsupervised method called MoDIP (Model-based Deep Image Prior). MoDIP comprises a small, untrained network and a Data Fidelity Optimization (DFO) module. The network converges to an interim state, acting as an implicit prior for image regularization, while the optimization process enforces the physical model of QSM dipole inversion. Experimental results demonstrate MoDIP's excellent generalizability in solving QSM dipole inversion across different scan parameters. It exhibits robustness against pathological brain QSM, achieving over 32 % accuracy improvement than supervised deep learning methods. It is also 33 % more computationally efficient and runs 4 times faster than conventional DIP-based approaches, enabling 3D high-resolution image reconstruction in under 4.5 min.


Assuntos
Encéfalo , Felodipino , Humanos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Mapeamento Encefálico/métodos , Algoritmos
2.
Neuroimage ; 288: 120528, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38311125

RESUMO

Quantitative susceptibility mapping (QSM) is frequently employed in investigating brain iron related to brain development and diseases within deep gray matter (DGM). Nonetheless, the acquisition of whole-brain QSM data is time-intensive. An alternative approach, focusing the QSM specifically on areas of interest such as the DGM by reducing the field-of-view (FOV), can significantly decrease scan times. However, severe susceptibility value underestimations have been reported during QSM reconstruction with a limited FOV, largely attributable to artifacts from incorrect background field removal in the boundary region. This presents a considerable barrier to the clinical use of QSM with small spatial coverages using conventional methods alone. To mitigate the propagation of these errors, we proposed a harmonic field extension method based on a physics-informed generative adversarial network. Both quantitative and qualitative results demonstrate that our method outperforms conventional methods and delivers results comparable to those obtained with full FOV. Furthermore, we demonstrate the versatility of our method by applying it to data acquired prospectively with limited FOV and to data from patients with Parkinson's disease. The method has shown significant improvements in local field results, with QSM outcomes. In a clear illustration of its feasibility and effectiveness in real clinical environments, our proposed method addresses the prevalent issue of susceptibility underestimation in QSM with small spatial coverage.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico/métodos
3.
Hum Brain Mapp ; 45(9): e26688, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38896001

RESUMO

Quantitative susceptibility mapping (QSM) is an MRI modality used to non-invasively measure iron content in the brain. Iron exhibits a specific anatomically varying pattern of accumulation in the brain across individuals. The highest regions of accumulation are the deep grey nuclei, where iron is stored in paramagnetic molecule ferritin. This form of iron is considered to be what largely contributes to the signal measured by QSM in the deep grey nuclei. It is also known that QSM is affected by diamagnetic myelin contents. Here, we investigate spatial gene expression of iron and myelin related genes, as measured by the Allen Human Brain Atlas, in relation to QSM images of age-matched subjects. We performed multiple linear regressions between gene expression and the average QSM signal within 34 distinct deep grey nuclei regions. Our results show a positive correlation (p < .05, corrected) between expression of ferritin and the QSM signal in deep grey nuclei regions. We repeated the analysis for other genes that encode proteins thought to be involved in the transport and storage of iron in the brain, as well as myelination. In addition to ferritin, our findings demonstrate a positive correlation (p < .05, corrected) between the expression of ferroportin, transferrin, divalent metal transporter 1, several gene markers of myelinating oligodendrocytes, and the QSM signal in deep grey nuclei regions. Our results suggest that the QSM signal reflects both the storage and active transport of iron in the deep grey nuclei regions of the brain.


Assuntos
Ferritinas , Homeostase , Ferro , Imageamento por Ressonância Magnética , Bainha de Mielina , Humanos , Ferro/metabolismo , Masculino , Feminino , Bainha de Mielina/metabolismo , Bainha de Mielina/genética , Adulto , Homeostase/fisiologia , Ferritinas/metabolismo , Ferritinas/genética , Encéfalo/metabolismo , Encéfalo/diagnóstico por imagem , Expressão Gênica , Pessoa de Meia-Idade , Proteínas de Transporte de Cátions/genética , Proteínas de Transporte de Cátions/metabolismo , Adulto Jovem , Mapeamento Encefálico/métodos
4.
Hum Brain Mapp ; 45(5): e26675, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38590155

RESUMO

Isolated REM sleep behavior disorder (iRBD) is an early stage of synucleinopathy with most patients progressing to Parkinson's disease (PD) or related conditions. Quantitative susceptibility mapping (QSM) in PD has identified pathological iron accumulation in the substantia nigra (SN) and variably also in basal ganglia and cortex. Analyzing whole-brain QSM across iRBD, PD, and healthy controls (HC) may help to ascertain the extent of neurodegeneration in prodromal synucleinopathy. 70 de novo PD patients, 70 iRBD patients, and 60 HCs underwent 3 T MRI. T1 and susceptibility-weighted images were acquired and processed to space standardized QSM. Voxel-based analyses of grey matter magnetic susceptibility differences comparing all groups were performed on the whole brain and upper brainstem levels with the statistical threshold set at family-wise error-corrected p-values <.05. Whole-brain analysis showed increased susceptibility in the bilateral fronto-parietal cortex of iRBD patients compared to both PD and HC. This was not associated with cortical thinning according to the cortical thickness analysis. Compared to iRBD, PD patients had increased susceptibility in the left amygdala and hippocampal region. Upper brainstem analysis revealed increased susceptibility within the bilateral SN for both PD and iRBD compared to HC; changes were located predominantly in nigrosome 1 in the former and nigrosome 2 in the latter group. In the iRBD group, abnormal dopamine transporter SPECT was associated with increased susceptibility in nigrosome 1. iRBD patients display greater fronto-parietal cortex involvement than incidental early-stage PD cohort indicating more widespread subclinical neuropathology. Dopaminergic degeneration in the substantia nigra is paralleled by susceptibility increase, mainly in nigrosome 1.


Assuntos
Doença de Parkinson , Transtorno do Comportamento do Sono REM , Sinucleinopatias , Humanos , Transtorno do Comportamento do Sono REM/diagnóstico por imagem , Sinucleinopatias/complicações , Sinucleinopatias/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Substância Negra/diagnóstico por imagem , Substância Negra/patologia , Doença de Parkinson/complicações , Ferro
5.
Magn Reson Med ; 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39238238

RESUMO

PURPOSE: To evaluate the repeatability and reproducibility of QSM of the liver via single breath-hold chemical shift-encoded MRI at both 1.5 T and 3 T in a multicenter, multivendor study in subjects with iron overload. METHODS: This prospective study included four academic medical centers with three different MRI vendors at 1.5 T and 3 T. Subjects with known or suspected liver iron overload underwent multi-echo spoiled gradient-recalled-echo scans at each field strength. A subset received repeatability testing at either 1.5 T or 3 T. Susceptibility and R 2 * $$ {\mathrm{R}}_2^{\ast } $$ maps were reconstructed from the multi-echo images and analyzed at a single center. QSM-measured susceptibility was compared with R 2 * $$ {\mathrm{R}}_2^{\ast } $$ and a commercial R2-based liver iron concentration method across centers and field strengths using linear regression and F-tests on the intercept and slope. Field-strength reproducibility and test/retest repeatability were evaluated using Bland-Altman analysis. RESULTS: A total of 155/80 data sets (test/retest) were available at 1.5 T, and 159/70 data sets (test/retest) were available at 3 T. Calibrations across sites were reproducible, with some variability (e.g., susceptibility slope with liver iron concentration ranged from 0.102 to 0.123 g/[mg · $$ \cdotp $$ ppm] across centers at 1.5 T). Field strength reproducibility was good (concordance correlation coefficient = 0.862), and test/retest repeatability was excellent (intraclass correlation coefficient = 0.951). CONCLUSION: QSM as an imaging biomarker of liver iron overload is feasible and repeatable across centers and MR vendors. It may be complementary with R 2 * $$ {\mathrm{R}}_2^{\ast } $$ as they are obtained from the same acquisition. Although good reproducibility was observed, liver QSM may benefit from standardization of acquisition parameters. Overall, QSM is a promising method for liver iron quantification.

6.
Magn Reson Med ; 92(3): 997-1010, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38778631

RESUMO

PURPOSE: QSM provides insight into healthy brain aging and neuropathologies such as multiple sclerosis (MS), traumatic brain injuries, brain tumors, and neurodegenerative diseases. Phase data for QSM are usually acquired from 3D gradient-echo (3D GRE) scans with long acquisition times that are detrimental to patient comfort and susceptible to patient motion. This is particularly true for scans requiring whole-brain coverage and submillimeter resolutions. In this work, we use a multishot 3D echo plannar imaging (3D EPI) sequence with shot-selective 2D CAIPIRIHANA to acquire high-resolution, whole-brain data for QSM with minimal distortion and blurring. METHODS: To test clinical viability, the 3D EPI sequence was used to image a cohort of MS patients at 1-mm isotropic resolution at 3 T. Additionally, 3D EPI data of healthy subjects were acquired at 1-mm, 0.78-mm, and 0.65-mm isotropic resolution with varying echo train lengths (ETLs) and compared with a reference 3D GRE acquisition. RESULTS: The appearance of the susceptibility maps and the susceptibility values for segmented regions of interest were comparable between 3D EPI and 3D GRE acquisitions for both healthy and MS participants. Additionally, all lesions visible in the MS patients on the 3D GRE susceptibility maps were also visible on the 3D EPI susceptibility maps. The interplay among acquisition time, resolution, echo train length, and the effect of distortion on the calculated susceptibility maps was investigated. CONCLUSION: We demonstrate that the 3D EPI sequence is capable of rapidly acquiring submillimeter resolutions and providing high-quality, clinically relevant susceptibility maps.


Assuntos
Encéfalo , Imagem Ecoplanar , Imageamento Tridimensional , Esclerose Múltipla , Humanos , Imageamento Tridimensional/métodos , Esclerose Múltipla/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Imagem Ecoplanar/métodos , Adulto , Masculino , Feminino , Algoritmos , Pessoa de Meia-Idade , Mapeamento Encefálico/métodos , Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Assistida por Computador/métodos
7.
Magn Reson Med ; 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39164832

RESUMO

PURPOSE: Data for QSM are typically acquired using multi-echo 3D gradient echo (GRE), but EPI can be used to accelerate QSM and provide shorter acquisition times. So far, EPI-QSM has been limited to single-echo acquisitions, which, for 3D GRE, are known to be less accurate than multi-echo sequences. Therefore, we compared single-echo and multi-echo EPI-QSM reconstructions across a range of parallel imaging and multiband acceleration factors. METHODS: Using 2D single-shot EPI in the brain, we compared QSM from single-echo and multi-echo acquisitions across combined parallel-imaging and multiband acceleration factors ranging from 2 to 16, with volume pulse TRs from 21.7 to 3.2 s, respectively. For single-echo versus multi-echo reconstructions, we investigated the effect of acceleration factors on regional susceptibility values, temporal noise, and image quality. We introduce a novel masking method based on thresholding the magnitude of the local field gradients to improve brain masking in challenging regions. RESULTS: At 1.6-mm isotropic resolution, high-quality QSM was achieved using multi-echo 2D EPI with a combined acceleration factor of 16 and a TR of 3.2 s, which enables functional applications. With these high acceleration factors, single-echo reconstructions are inaccurate and artefacted, rendering them unusable. Multi-echo acquisitions greatly improve QSM quality, particularly at higher acceleration factors, provide more consistent regional susceptibility values across acceleration factors, and decrease temporal noise compared with single-echo QSM reconstructions. CONCLUSION: Multi-echo acquisition is more robust for EPI-QSM across parallel imaging and multiband acceleration factors than single-echo acquisition. Multi-echo EPI can be used for highly accelerated acquisition while preserving QSM accuracy and quality relative to gold-standard 3D-GRE QSM.

8.
Magn Reson Med ; 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39221556

RESUMO

PURPOSE: To propose a new method for quantitatively mapping the renal metabolic rate of oxygen (RMRO2) and to evaluate the proposed method using a caffeine challenge. THEORY AND METHODS: Pseudo-continuous arterial spin labeling (pCASL) and QSM sequences were used to obtain MR images in the kidney. Six healthy volunteers were scanned on caffeine and control days. The pCASL and QSM images were registered using DICOM information and rigid translation. The Fick principle was applied to estimate RMRO2. The results on caffeine and control days were compared to evaluate the capability of the proposed method to estimate renal oxygen consumption. A paired t-test was used to assess the statistical significance. RESULTS: Estimated renal blood flow (RBF), QSM, and RMRO2 maps were consistent with those reported in the literature. RMRO2 values were higher than the cerebral metabolic rate of oxygen (CMRO2) and were significantly reduced on the caffeine days compared to the control days, consistent with findings from non-MRI literature. CONCLUSION: The feasibility of measuring renal oxygen consumption using pCASL and QSM images was demonstrated. To the best of our knowledge, this work provides quantitative maps of renal oxygen consumption in humans for the first time. The results were consistent with the literature, including the statistically significant reduction in renal oxygen consumption with caffeine challenge. These findings suggest the potential utility of our technique in measuring renal oxygen consumption noninvasively, especially for patients with complications associated with contrast agents.

9.
Magn Reson Med ; 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39233495

RESUMO

PURPOSE: To develop an efficient navigator-based motion and temporal B0-shift correction technique for 3D multi-echo gradient-echo (ME-GRE) MRI for quantitative susceptibility mapping (QSM) and R 2 * $$ {\mathrm{R}}_2^{\ast } $$ mapping. THEORY AND METHODS: A dual-echo 3D stack-of-spiral navigator was designed to interleave with the Cartesian multi-echo gradient-echo acquisitions, allowing the acquisition of both low-echo and high-echo time signals. We additionally designed a novel conjugate phase-based reconstruction method for the joint correction of motion and temporal B0 shifts. We performed numerical simulation, phantom scans, and in vivo human scans to assess the performance of the methods. RESULTS: Numerical simulation and human brain scans demonstrated that the proposed technique successfully corrected artifacts induced by both head motions and temporal B0 changes. Efficient B0-change correction with conjugate-phase reconstruction can be performed on fewer than 10 clustered k-space segments. In vivo scans showed that combining temporal B0 correction with motion correction further reduced artifacts and improved image quality in both R 2 * $$ {\mathrm{R}}_2^{\ast } $$ and QSM images. CONCLUSION: Our proposed approach of using 3D spiral navigators and a novel conjugate-phase reconstruction method can improve susceptibility-related measurements using MR.

10.
Magn Reson Med ; 91(4): 1676-1693, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38102838

RESUMO

PURPOSE: This work is to investigate the microstructure-induced frequency shift in white matter (WM) with crossing fibers and to separate the microstructure-related frequency shift from the bulk susceptibility-induced frequency shift by model fitting the gradient-echo (GRE) frequency evolution for potentially more accurate quantitative susceptibility mapping (QSM). METHODS: A hollow-cylinder fiber model (HCFM) with two fiber populations was developed to investigate GRE frequency evolutions in WM voxels with microstructural orientation dispersion. The simulated and experimentally measured TE-dependent local frequency shift was then fitted to a simplified frequency evolution model to obtain a microstructure-related frequency difference parameter ( ∆ f $$ \Delta f $$ ) and a TE-independent bulk susceptibility-induced frequency shift ( C f $$ {C}_f $$ ). The obtained C f $$ {C}_f $$ was then used for QSM reconstruction. Reconstruction performances were evaluated using a numerical head phantom and in vivo data and then compared to other multi-echo combination methods. RESULTS: GRE frequency evolutions and ∆ f $$ \Delta f $$ -based tissue parameters in both parallel and crossing fibers determined from our simulations were comparable to those observed in vivo. The TE-dependent frequency fitting method outperformed other multi-echo combination methods in estimating C f $$ {C}_f $$ in simulations. The fitted ∆ f $$ \Delta f $$ , C f $$ {C}_f $$ , and QSM could be improved further by navigator-based B0 fluctuation correction. CONCLUSION: A HCFM with two fiber populations can be used to characterize microstructure-induced frequency shifts in WM regions with crossing fibers. HCFM-based TE-dependent frequency fitting provides tissue contrast related to microstructure ( ∆ f $$ \Delta f $$ ) and in addition may help improve the quantification accuracy of C f $$ {C}_f $$ and the corresponding QSM.


Assuntos
Substância Branca , Substância Branca/diagnóstico por imagem , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem
11.
Magn Reson Med ; 92(6): 2294-2311, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38988040

RESUMO

PURPOSE: To explore the high signal-to-noise ratio (SNR) efficiency of interleaved multishot 3D-EPI with standard image reconstruction for fast and robust high-resolution whole-brain quantitative susceptibility (QSM) and R 2 ∗ $$ {R}_2^{\ast } $$ mapping at 7 and 3T. METHODS: Single- and multi-TE segmented 3D-EPI is combined with conventional CAIPIRINHA undersampling for up to 72-fold effective gradient echo (GRE) imaging acceleration. Across multiple averages, scan parameters are varied (e.g., dual-polarity frequency-encoding) to additionally correct for B 0 $$ {\mathrm{B}}_0 $$ -induced artifacts, geometric distortions and motion retrospectively. A comparison to established GRE protocols is made. Resolutions range from 1.4 mm isotropic (1 multi-TE average in 36 s) up to 0.4 mm isotropic (2 single-TE averages in approximately 6 min) with whole-head coverage. RESULTS: Only 1-4 averages are needed for sufficient SNR with 3D-EPI, depending on resolution and field strength. Fast scanning and small voxels together with retrospective corrections result in substantially reduced image artifacts, which improves susceptibility and R 2 ∗ $$ {R}_2^{\ast } $$ mapping. Additionally, much finer details are obtained in susceptibility-weighted image projections through significantly reduced partial voluming. CONCLUSION: Using interleaved multishot 3D-EPI, single-TE and multi-TE data can readily be acquired 10 times faster than with conventional, accelerated GRE imaging. Even 0.4 mm isotropic whole-head QSM within 6 min becomes feasible at 7T. At 3T, motion-robust 0.8 mm isotropic whole-brain QSM and R 2 ∗ $$ {R}_2^{\ast } $$ mapping with no apparent distortion in less than 7 min becomes clinically feasible. Stronger gradient systems may allow for even higher effective acceleration rates through larger EPI factors while maintaining optimal contrast.


Assuntos
Algoritmos , Artefatos , Encéfalo , Imagem Ecoplanar , Imageamento Tridimensional , Razão Sinal-Ruído , Humanos , Imageamento Tridimensional/métodos , Encéfalo/diagnóstico por imagem , Imagem Ecoplanar/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Masculino , Mapeamento Encefálico/métodos , Adulto , Feminino
12.
Magn Reson Med ; 2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39250435

RESUMO

PURPOSE: To develop a 3D spherical EPTI (sEPTI) acquisition and a comprehensive reconstruction pipeline for rapid high-quality whole-brain submillimeter T 2 * $$ {\mathrm{T}}_2^{\ast } $$ and QSM quantification. METHODS: For the sEPTI acquisition, spherical k-space coverage is utilized with variable echo-spacing and maximum kx ramp-sampling to improve efficiency and signal incoherency compared to existing EPTI approaches. For reconstruction, an iterative rank-shrinking B0 estimation and odd-even high-order phase correction algorithms were incorporated into the reconstruction to better mitigate artifacts from field imperfections. A physics-informed unrolled network was utilized to boost the SNR, where 1-mm and 0.75-mm isotropic whole-brain imaging were performed in 45 and 90 s at 3 T, respectively. These protocols were validated through simulations, phantom, and in vivo experiments. Ten healthy subjects were recruited to provide sufficient data for the unrolled network. The entire pipeline was validated on additional five healthy subjects where different EPTI sampling approaches were compared. Two additional pediatric patients with epilepsy were recruited to demonstrate the generalizability of the unrolled reconstruction. RESULTS: sEPTI achieved 1.4 × $$ \times $$ faster imaging with improved image quality and quantitative map precision compared to existing EPTI approaches. The B0 update and the phase correction provide improved reconstruction performance with lower artifacts. The unrolled network boosted the SNR, achieving high-quality T 2 * $$ {\mathrm{T}}_2^{\ast } $$ and QSM quantification with single average data. High-quality reconstruction was also obtained in the pediatric patients using this network. CONCLUSION: sEPTI achieved whole-brain distortion-free multi-echo imaging and T 2 * $$ {\mathrm{T}}_2^{\ast } $$ and QSM quantification at 0.75 mm in 90 s which has the potential to be useful for wide clinical applications.

13.
Magn Reson Med ; 91(6): 2310-2319, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38156825

RESUMO

PURPOSE: This study aimed to evaluate the potential of 3D EPI for improving the reliability of T 2 * $$ {\mathrm{T}}_2^{\ast } $$ -weighted data and quantification of R 2 * $$ {\mathrm{R}}_2^{\ast } $$ decay rate and susceptibility (χ) compared with conventional gradient-echo (GRE)-based acquisition. METHODS: Eight healthy subjects in a wide age range were recruited. Each subject received repeated scans for both GRE and EPI acquisitions with an isotropic 1 mm resolution at 3 T. Maps of R 2 * $$ {\mathrm{R}}_2^{\ast } $$ and χ were quantified, and their interscan differences were used to evaluate the test-retest reliability. Interprotocol differences of R 2 * $$ {\mathrm{R}}_2^{\ast } $$ and χ between GRE and EPI were also measured voxel by voxel and in selected regions of interest to test the consistency between the two acquisition methods. RESULTS: The quantifications of R 2 * $$ {\mathrm{R}}_2^{\ast } $$ and χ using EPI protocols showed increased test-retest reliability with higher EPI factors up to 5 as performed in the experiment and were consistent with those based on GRE. CONCLUSION: The result suggests that multishot multi-echo 3D EPI can be a useful alternative acquisition method for T 2 * $$ {\mathrm{T}}_2^{\ast } $$ -weighted MRI and quantification of R 2 * $$ {\mathrm{R}}_2^{\ast } $$ and χ with reduced scan time, improved test-retest reliability, and similar accuracy compared with commonly used 3D GRE.


Assuntos
Imagem Ecoplanar , Imageamento por Ressonância Magnética , Humanos , Imagem Ecoplanar/métodos , Reprodutibilidade dos Testes , Voluntários Saudáveis
14.
NMR Biomed ; 37(8): e5139, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38465729

RESUMO

T1-weighted magnetization-prepared rapid gradient-echo (MPRAGE) is commonly included in brain studies for structural imaging using magnitude images; however, its phase images can provide an opportunity to assess microbleed burden using quantitative susceptibility mapping (QSM). This potential application for MPRAGE-based QSM was evaluated using in vivo and simulated measurements. Possible factors affecting image quality were also explored. Detection sensitivity was evaluated against standard multiecho gradient echo (MEGE) QSM using 3-T in vivo data of 15 subjects with a combined total of 108 confirmed microbleeds. The two methods were compared based on the microbleed size and susceptibility measurements. In addition, simulations explored the detection sensitivity of MPRAGE-QSM at different representative magnetic field strengths and echo times using microbleeds of different size, susceptibility, and location. Results showed that in vivo microbleeds appeared to be smaller (× 0.54) and of higher mean susceptibility (× 1.9) on MPRAGE-QSM than on MEGE-QSM, but total susceptibility estimates were in closer agreement (slope: 0.97, r2: 0.94), and detection sensitivity was comparable. In simulations, QSM at 1.5 T had a low contrast-to-noise ratio that obscured the detection of many microbleeds. Signal-to-noise ratio (SNR) levels at 3 T and above resulted in better contrast and increased detection. The detection rates for microbleeds of minimum one-voxel diameter and 0.4-ppm susceptibility were 0.55, 0.80, and 0.88 at SNR levels of 1.5, 3, and 7 T, respectively. Size and total susceptibility estimates were more consistent than mean susceptibility estimates, which showed size-dependent underestimation. MPRAGE-QSM provides an opportunity to detect and quantify the size and susceptibility of microbleeds of at least one-voxel diameter at B0 of 3 T or higher with no additional time cost, when standard T2*-weighted images are not available or have inadequate spatial resolution. The total susceptibility measure is more robust against sequence variations and might allow combining data from different protocols.


Assuntos
Hemorragia Cerebral , Imageamento por Ressonância Magnética , Humanos , Hemorragia Cerebral/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Idoso , Simulação por Computador , Adulto
15.
NMR Biomed ; : e5263, 2024 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-39401773

RESUMO

Quantitative susceptibility mapping (QSM) is a tool for mapping tissue susceptibility. Using QSM for functional brain mapping, it is possible to directly quantify blood-oxygen-level-dependent (BOLD) susceptibility changes. This study presents a submillimeter functional QSM (fQSM) approach compared to BOLD fMRI from data acquired with 3D gradient-echo echo planar imaging (EPI) at ultra-high field. Complex EPI data were acquired in nine healthy subjects with varying temporal and spatial resolutions and used for BOLD fMRI and for fQSM. Right-hand finger tapping experiments were performed as well as one measurement with intentional subject movement. Susceptibility maps were computed using 3D path-based unwrapping, the variable-kernel sophisticated harmonic artifact reduction for phase data, and the streaking artifact reduction for QSM algorithm. Functional data analysis included general linear modeling and computation of z-scores. Submillimeter data were denoised using NOise reduction with DIstribution Corrected (NORDIC), which improved z-scores in the motor cortex for fQSM and fMRI. An expected increase in BOLD fMRI signal and corresponding decrease in magnetic susceptibility was observed in sensorimotor areas during active periods. For all experiments, fQSM showed smaller activation regions compared with fMRI. The percentage of high negative t-values localized in the cortex was higher for fQSM (52%) than for positive or negative t-values for fMRI (45%). For the scans with intentional motion, movement exceeded the size of a voxel, but paradigm dependent signal evolution could be recovered using motion correction. In conclusion, this study demonstrates the feasibility of submillimeter whole-brain fQSM with voxel volume of 0.53 µL. In comparison to traditional BOLD fMRI, fQSM provided improved localization of brain activation within the cortex, especially in submillimeter 3D EPI sequences.

16.
Mov Disord ; 39(3): 546-559, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38173297

RESUMO

BACKGROUND: Dementia is common in Parkinson's disease (PD), but there is wide variation in its timing. A critical gap in PD research is the lack of quantifiable markers of progression, and methods to identify early stages of dementia. Atrophy-based magnetic resonance imaging (MRI) has limited sensitivity in detecting or tracking changes relating to PD dementia, but quantitative susceptibility mapping (QSM), sensitive to brain tissue iron, shows potential for these purposes. OBJECTIVE: The objective of the paper is to study, for the first time, the longitudinal relationship between cognition and QSM in PD in detail. METHODS: We present a longitudinal study of clinical severity in PD using QSM, including 59 PD patients (without dementia at study onset), and 22 controls over 3 years. RESULTS: In PD, increased baseline susceptibility in the right temporal cortex, nucleus basalis of Meynert, and putamen was associated with greater cognitive severity after 3 years; and increased baseline susceptibility in basal ganglia, substantia nigra, red nucleus, insular cortex, and dentate nucleus was associated with greater motor severity after 3 years. Increased follow-up susceptibility in these regions was associated with increased follow-up cognitive and motor severity, with further involvement of hippocampus relating to cognitive severity. However, there were no consistent increases in susceptibility over 3 years. CONCLUSIONS: Our study suggests that QSM may predict changes in cognitive severity many months prior to overt cognitive involvement in PD. However, we did not find robust longitudinal changes in QSM over the course of the study. Additional tissue metrics may be required together with QSM for it to monitor progression in clinical practice and therapeutic trials. © 2024 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.


Assuntos
Doença de Alzheimer , Doença de Parkinson , Humanos , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/patologia , Estudos Longitudinais , Gânglios da Base/patologia , Substância Negra/patologia , Imageamento por Ressonância Magnética/métodos
17.
J Cardiovasc Magn Reson ; 26(1): 101000, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38237902

RESUMO

BACKGROUND: Myocardial quantitative susceptibility mapping (QSM) may offer better specificity to iron than conventional T2* imaging in the assessment of cardiac diseases, including intra-myocardial hemorrhage. However, the precision and repeatability of cardiac QSM have not yet been characterized. The aim of this study is to characterize these key metrics in a healthy volunteer cohort and show the feasibility of the method in patients. METHODS: Free breathing respiratory-navigated multi-echo 3D gradient echo images were acquired, from which QSM maps were reconstructed using the Morphology Enhanced Dipole Inversion toolbox. This technique was first evaluated in a susceptibility phantom containing tubes with known concentrations of gadolinium. In vivo characterization of myocardial QSM was then performed in a cohort of 10 healthy volunteers where each subject was scanned twice. Mean segment susceptibility, precision (standard deviation of voxel magnetic susceptibilities within one segment), and repeatability (absolute difference in segment mean susceptibility between repeats) of QSM were calculated for each American Heart Association (AHA) myocardial segment. Finally, the feasibility of the method was shown in 10 patients, including four with hemorrhagic infarcts. RESULTS: The phantom experiment showed a strong linear relationship between measured and predicted susceptibility shifts (R2 > 0.99). For the healthy volunteer cohort, AHA segment analysis showed the mean segment susceptibility was 0.00 ± 0.02 ppm, the mean precision was 0.05 ± 0.04 ppm, and the mean repeatability was 0.02 ± 0.02 ppm. Cardiac QSM was successfully performed in all patients. Focal iron deposits were successfully visualized in the patients with hemorrhagic myocardial infarctions. CONCLUSION: The precision and repeatability of cardiac QSM were successfully characterized in phantom and in vivo experiments. The feasibility of the technique was also successfully demonstrated in patients. While challenges still remain, further clinical evaluation of the technique is now warranted. TRIAL REGISTRATION: This work does not report on a health care intervention.


Assuntos
Estudos de Viabilidade , Ventrículos do Coração , Imagens de Fantasmas , Valor Preditivo dos Testes , Humanos , Reprodutibilidade dos Testes , Masculino , Pessoa de Meia-Idade , Adulto , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Voluntários Saudáveis , Imageamento por Ressonância Magnética , Estudos de Casos e Controles , Idoso , Interpretação de Imagem Assistida por Computador , Meios de Contraste/administração & dosagem , Miocárdio/patologia , Adulto Jovem , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia
18.
Neurol Sci ; 45(7): 3007-3020, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38367153

RESUMO

One of the goals of this systematic review is to provide a meta-analysis-derived mean OEF of healthy volunteers. Another aim of this study is to indicate the OEF ranges of various neurological pathologies. Potential clinical applications of OEF metrics are presented. Peer-reviewed studies reporting OEF metrics derived from computed tomography (CT)/positron emission tomography (PET) and/or magnetic resonance imaging (MRI) were considered. Databases utilized included MEDLINE, PubMed, EMBASE, Web of Science, and Google Scholar. The Newcastle-Ottawa scoring system was used for evaluating studies. R Studio was utilized for the meta-analysis calculations when appropriate. The GRADE framework was utilized to assess additional findings. Of 2267 potential studies, 165 met the inclusion criteria. The healthy volunteer meta-analysis included 339 subjects and found a mean OEF value of 38.87 (37.38, 40.36), with a prediction interval of 32.40-45.34. There were no statistical differences in OEF values derived from PET versus MRI. We provided a GRADE A certainty rating for the use of OEF metrics to predict stroke occurrence in patients with symptomatic carotid or cerebral vessel disease. We provided a GRADE B certainty rating for monitoring treatment response in Moyamoya disease. Use of OEF metrics in diagnosing and/or monitoring other conditions had a GRADE C certainty rating or less. OEF might have a role in diagnosing and monitoring patients with symptomatic carotid or cerebral vessel disease and Moyamoya disease. While we found insufficient evidence to support measuring OEF metrics in other patient populations, in many cases, further studies are warranted.


Assuntos
Doenças do Sistema Nervoso , Oxigênio , Humanos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Doenças do Sistema Nervoso/diagnóstico por imagem , Oxigênio/sangue , Tomografia por Emissão de Pósitrons
19.
Neuroimage ; 267: 119842, 2023 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-36586542

RESUMO

Deep neural networks have demonstrated great potential in solving dipole inversion for Quantitative Susceptibility Mapping (QSM). However, the performances of most existing deep learning methods drastically degrade with mismatched sequence parameters such as acquisition orientation and spatial resolution. We propose an end-to-end AFfine Transformation Edited and Refined (AFTER) deep neural network for QSM, which is robust against arbitrary acquisition orientation and spatial resolution up to 0.6 mm isotropic at the finest. The AFTER-QSM neural network starts with a forward affine transformation layer, followed by a Unet for dipole inversion, then an inverse affine transformation layer, followed by a Residual Dense Network (RDN) for QSM refinement. Simulation and in-vivo experiments demonstrated that the proposed AFTER-QSM network architecture had excellent generalizability. It can successfully reconstruct susceptibility maps from highly oblique and anisotropic scans, leading to the best image quality assessments in simulation tests and suppressed streaking artifacts and noise levels for in-vivo experiments compared with other methods. Furthermore, ablation studies showed that the RDN refinement network significantly reduced image blurring and susceptibility underestimation due to affine transformations. In addition, the AFTER-QSM network substantially shortened the reconstruction time from minutes using conventional methods to only a few seconds.


Assuntos
Encéfalo , Processamento de Imagem Assistida por Computador , Humanos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação , Simulação por Computador , Algoritmos , Mapeamento Encefálico/métodos
20.
Neuroimage ; 283: 120419, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37871759

RESUMO

Quantitative Susceptibility Mapping has the potential to provide additional insights into neurological diseases but is typically based on a quite long (5-10 min) 3D gradient-echo scan which is highly sensitive to motion. We propose an ultra-fast acquisition based on three orthogonal (sagittal, coronal and axial) 2D simultaneous multi-slice EPI scans with 1 mm in-plane resolution and 3 mm thick slices. Images in each orientation are corrected for susceptibility-related distortions and co-registered with an iterative non-linear Minimum Deformation Averaging (Volgenmodel) approach to generate a high SNR, super-resolution data set with an isotropic resolution of close to 1 mm. The net acquisition time is 3 times the volume acquisition time of EPI or about 12 s, but the three volumes could also replace "dummy scans" in fMRI, making it feasible to acquire QSM in little or No Additional Time for Imaging (NATIve). NATIve QSM values agreed well with reference 3D GRE QSM in the basal ganglia in healthy subjects. In patients with multiple sclerosis, there was also a good agreement between the susceptibility values within lesions and control ROIs and all lesions which could be seen on 3D GRE QSMs could also be visualized on NATIve QSMs. The approach is faster than conventional 3D GRE by a factor of 25-50 and faster than 3D EPI by a factor of 3-5. As a 2D technique, NATIve QSM was shown to be much more robust to motion than the 3D GRE and 3D EPI, opening up the possibility of studying neurological diseases involving iron accumulation and demyelination in patients who find it difficult to lie still for long enough to acquire QSM data with conventional methods.


Assuntos
Imagem Ecoplanar , Humanos , Imagem Ecoplanar/métodos , Gânglios da Base/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA