Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 91(4): 1323-1336, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38156527

RESUMO

PURPOSE: The characterization of tissue microstructure using diffusion MRI (dMRI) signals is rapidly evolving, with increasing sophistication of signal representations and microstructure models. However, this progress often requires signals to be acquired with very high b-values (e.g., b > 30 ms/µm2 ), along many directions, and using multiple b-values, leading to long scan times and extremely low SNR in dMRI images. The purpose of this work is to boost the SNR efficiency of dMRI by combining three particularly efficient spatial encoding techniques and utilizing a high-performance gradient system (Gmax ≤ 300 mT/m) for efficient diffusion encoding. METHODS: Spiral readouts, multiband imaging, and sampling on tilted hexagonal grids (T-Hex) are combined and implemented on a 3T MRI system with ultra-strong gradients. Image reconstruction is performed through an iterative cg-SENSE algorithm incorporating static off-resonance distributions and field dynamics as measured with an NMR field camera. Additionally, T-Hex multiband is combined with a more conventional EPI-readout and compared with state-of-the-art blipped-CAIPIRINHA sampling. The advantage of the proposed approach is furthermore investigated for clinically available gradient performance and diffusion kurtosis imaging. RESULTS: High fidelity in vivo images with b-values up to 40 ms/µm2 are obtained. The approach provides superior SNR efficiency over other state-of-the-art multiband diffusion readout schemes. CONCLUSION: The demonstrated gains hold promise for the widespread dissemination of advanced microstructural scans, especially in clinical populations.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagem de Tensor de Difusão , Algoritmos , Encéfalo/diagnóstico por imagem
2.
J Magn Reson Imaging ; 59(4): 1170-1178, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37334872

RESUMO

BACKGROUND: Simultaneous multi-slice diffusion-weighted imaging (SMS-DWI) can shorten acquisition time in abdominal imaging. PURPOSE: To investigate the agreement and reproducibility of apparent diffusion coefficient (ADC) from abdominal SMS-DWI acquired with different vendors and different breathing schemes. STUDY TYPE: Prospective. SUBJECTS: Twenty volunteers and 10 patients. FIELD STRENGTH/SEQUENCE: 3.0 T, SMS-DWI with a diffusion-weighted echo-planar imaging sequence. ASSESSMENT: SMS-DWI was acquired using breath-hold and free-breathing techniques in scanners from two vendors, yielding four scans in each participant. Average ADC values were measured in the liver, pancreas, spleen, and both kidneys. Non-normalized ADC and ADCs normalized to the spleen were compared between vendors and breathing schemes. STATISTICAL TESTS: Paired t-test or Wilcoxon signed rank test; intraclass correlation coefficient (ICC); Bland-Altman method; coefficient of variation (CV) analysis; significance level: P < 0.05. RESULTS: Non-normalized ADCs from the four SMS-DWI scans did not differ significantly in the spleen (P = 0.262, 0.330, 0.166, 0.122), right kidney (P = 0.167, 0.538, 0.957, 0.086), and left kidney (P = 0.182, 0.281, 0.504, 0.405), but there were significant differences in the liver and pancreas. For normalized ADCs, there were no significant differences in the liver (P = 0.315, 0.915, 0.198, 0.799), spleen (P = 0.815, 0.689, 0.347, 0.423), pancreas (P = 0.165, 0.336, 0.304, 0.584), right kidney (P = 0.165, 0.336, 0.304, 0.584), and left kidney (P = 0.496, 0.304, 0.443, 0.371). Inter-reader agreements of non-normalized ADCs were good to excellent (ICCs ranged from 0.861 to 0.983), and agreement and reproducibility were good to excellent depending on anatomic location (CVs ranged from 3.55% to 13.98%). Overall CVs for abdominal ADCs from the four scans were 6.25%, 7.62%, 7.08, and 7.60%. DATA CONCLUSION: The normalized ADCs from abdominal SMS-DWI may be comparable between different vendors and breathing schemes, showing good agreement and reproducibility. ADC changes above approximately 8% may potentially be considered as a reliable quantitative biomarker to assess disease or treatment-related changes. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.


Assuntos
Abdome , Pâncreas , Humanos , Reprodutibilidade dos Testes , Estudos Prospectivos , Abdome/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar
3.
Eur Radiol ; 34(4): 2457-2467, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37776361

RESUMO

OBJECTIVES: Diffusion-weighted imaging (DWI) with simultaneous multi-slice (SMS) acquisition and advanced processing can accelerate acquisition time and improve MR image quality. This study evaluated the image quality and apparent diffusion coefficient (ADC) measurements of free-breathing DWI acquired from patients with liver metastases using a prototype SMS-DWI acquisition (with/without an advanced processing option) and conventional DWI. METHODS: Four DWI schemes were compared in a pilot 5-patient cohort; three DWI schemes were further assessed in a 24-patient cohort. Two readers scored image quality of all b-value images and ADC maps across the three methods. ADC measurements were performed, for all three methods, in left and right liver parenchyma, spleen, and liver metastases. The Friedman non-parametric test (post-hoc Wilcoxon test with Bonferroni correction) was used to compare image quality scoring; t-test was used for ADC comparisons. RESULTS: SMS-DWI was faster (by 24%) than conventional DWI. Both readers scored the SMS-DWI with advanced processing as having the best image quality for highest b-value images (b750) and ADC maps; Cohen's kappa inter-reader agreement was 0.6 for b750 image and 0.56 for ADC maps. The prototype SMS-DWI sequence with advanced processing allowed a better visualization of the left lobe of the liver. ADC measured in liver parenchyma, spleen, and liver metastases using the SMS-DWI with advanced processing option showed lower values than those derived from the SMS-DWI method alone (t-test, p < 0.0001; p < 0.0001; p = 0.002). CONCLUSIONS: Free-breathing SMS-DWI with advanced processing was faster and demonstrated better image quality versus a conventional DWI protocol in liver patients. CLINICAL RELEVANCE STATEMENT: Free-breathing simultaneous multi-slice- diffusion-weighted imaging (DWI) with advanced processing was faster and demonstrated better image quality versus a conventional DWI protocol in liver patients. KEY POINTS: • Diffusion-weighted imaging (DWI) with simultaneous multi-slice (SMS) can accelerate acquisition time and improve image quality. • Apparent diffusion coefficients (ADC) measured in liver parenchyma, spleen, and liver metastases using the simultaneous multi-slice DWI with advanced processing were significantly lower than those derived from the simultaneous multi-slice DWI method alone. • Simultaneous multi-slice DWI sequence with inline advanced processing was faster and demonstrated better image quality in liver patients.


Assuntos
Neoplasias Hepáticas , Respiração , Humanos , Reprodutibilidade dos Testes , Neoplasias Hepáticas/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos
4.
Skeletal Radiol ; 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38441617

RESUMO

Magnetic resonance imaging (MRI) is crucial for accurately diagnosing a wide spectrum of musculoskeletal conditions due to its superior soft tissue contrast resolution. However, the long acquisition times of traditional two-dimensional (2D) and three-dimensional (3D) fast and turbo spin-echo (TSE) pulse sequences can limit patient access and comfort. Recent technical advancements have introduced acceleration techniques that significantly reduce MRI times for musculoskeletal examinations. Key acceleration methods include parallel imaging (PI), simultaneous multi-slice acquisition (SMS), and compressed sensing (CS), enabling up to eightfold faster scans while maintaining image quality, resolution, and safety standards. These innovations now allow for 3- to 6-fold accelerated clinical musculoskeletal MRI exams, reducing scan times to 4 to 6 min for joints and spine imaging. Evolving deep learning-based image reconstruction promises even faster scans without compromising quality. Current research indicates that combining acceleration techniques, deep learning image reconstruction, and superresolution algorithms will eventually facilitate tenfold accelerated musculoskeletal MRI in routine clinical practice. Such rapid MRI protocols can drastically reduce scan times by 80-90% compared to conventional methods. Implementing these rapid imaging protocols does impact workflow, indirect costs, and workload for MRI technologists and radiologists, which requires careful management. However, the shift from conventional to accelerated, deep learning-based MRI enhances the value of musculoskeletal MRI by improving patient access and comfort and promoting sustainable imaging practices. This article offers a comprehensive overview of the technical aspects, benefits, and challenges of modern accelerated musculoskeletal MRI, guiding radiologists and researchers in this evolving field.

5.
Skeletal Radiol ; 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38913177

RESUMO

OBJECTIVES: To explore the feasibility of simultaneous multi-slice (SMS) technique for reducing acquisition times in readout-segmented echo planar imaging (RESOLVE) for diffusion tensor imaging (DTI) of the knee. MATERIALS AND METHODS: A total of 30 healthy volunteers and 23 patients with knee acute injury (12 cases with anterior ligament (ACL) tears and 16 cases with patellar cartilage (PC) injury) were enrolled in this prospective study. Three DTI protocols were used: conventional RESOLVE-DTI with 12 directions (protocol 1), SMS-RESOLVE-DTI with 12 directions (protocol 2) and 20 directions (protocol 3). DTI parameters of gastrocnemius, ACL and posterior cruciate ligament (PCL), and PC from three protocols were quantitatively assessed. RESULTS: For volunteers, protocol 2 significantly reduced acquisition time by 38.6% and 34.2% compared to protocols 1 and 3 while maintaining similar high-quality images and similar diffusive parameters, except for the fractional anisotropy (FA) and axial diffusivity (AD) of the PC between protocols 2 and 1 (P < 0.05). For injured ACL and PC, protocols 1 and 2 showed similar accurate diffusive parameters (except for AD, P = 0.025) and similar diagnostic efficacy, which demonstrated significantly lower FA and higher radial diffusivity (RD) in protocols 1 and 2 compared to volunteers (P < 0.05). CONCLUSIONS: The 12-direction SMS-RESOLVE-DTI demonstrated a favorable balance between acquisition time and image quality, making it a promising alternative to conventional DTI for evaluating ligament and cartilage injuries. ADVANCES IN KNOWLEDGE: The SMS technique greatly reduces acquisition time while maintaining image quality, which signified the possibility of DTI's clinical application.

6.
Magn Reson Med ; 90(2): 539-551, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37036367

RESUMO

PURPOSE: Enabling fast and accessible myocardial T1 mapping is crucial for extending its clinical application. We introduce Open-MOLLI-SMS combining simultaneous multi-slice (SMS) with auto-calibration and variable-rate selective excitation (VERSE)-multiband pulses to obtain all slices in a fast single-shot T1 mapping sequence. METHODS: Open-MOLLI-SMS was developed by integrating SMS with the open-source method Open-MOLLI previously implemented in Pulseq. Three methods were integrated for Open-MOLLI-SMS: (1) auto-calibration blip patterns to ensure consistency between the data and coil information; (2) a blipped-balanced SSFP (bSSFP) readout to induce controlled aliasing in parallel imaging shifts without disturbing the bSSFP frequency response; and (3) a VERSE-multiband pulse for minimizing the achievable TR and the specific absortion rate (SAR) impact of SMS. Two (SMS2) or three (SMS3) slices were excited simultaneously and encoded with an in-plane acceleration factor of 2. Experiments were performed in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology phantom and five healthy volunteers. RESULTS: Phantom results show accurate T1 estimates for reference values between 400 to 2200 ms. Artifacts were visible for Open-MOLLI-SMS3 but not replicated in vivo. In vivo Open-MOLLI-SMS (T1 SMS2 = 993 ± 10 ms; T1 SMS3 = 1031 ± 17 ms) provided similar values to mean T1 single-band Open-MOLLI estimates (T1 Open-MOLLI = 1005 ± 47 ms). Open-MOLLI-SMS2 provided the closest estimates to the reference. CONCLUSION: This proof-of-principle implementation study demonstrates the feasibility of speeding up T1 -mapping acquisitions and increasing coverage by combining auto-calibration strategies with a blipped-bSFFP readout and VERSE multiband RF excitation pulses. The proposed methodology was built on the Open-MOLLI mapping sequence, which provides a fast means for prototyping and enables open-source sharing of the method.


Assuntos
Interpretação de Imagem Assistida por Computador , Miocárdio , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Aceleração , Reprodutibilidade dos Testes , Coração/diagnóstico por imagem
7.
Magn Reson Med ; 90(1): 222-230, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36864561

RESUMO

PURPOSE: To investigate the feasibility of combining simultaneous multislice (SMS) and region-optimized virtual coils (ROVir) for single breath-hold CINE imaging. METHOD: ROVir is a recent virtual coil approach that allows reduced-field of view (FOV) imaging by localizing the signal from a region-of-interest (ROI) and/or suppressing the signal from unwanted spatial regions. In this work, ROVir is used for reduced-FOV SMS bSSFP CINE imaging, which enables whole heart CINE with a single breath-hold acquisition. RESULTS: Reduced-FOV CINE with either SMS-only or ROVir-only resulted in significant aliasing, with severely reduced image quality when compared to the full FOV reference CINE, while the visual appearance of aliasing was substantially reduced with the proposed SMS+ROVir. The end diastolic volume, end systolic volume, and ejection fraction obtained using the proposed approach were similar to the clinical reference (correlations of 0.92, 0.94, and 0.88, respectively with p < 0 . 05 $$ p<0.05 $$ in each case, and biases of 0.1, 1.6 mL, and - 0 . 6 % $$ -0.6\% $$ , respectively). No statistically significant differences for these parameters were found with a Wilcoxon rank test (p = 0.96, 0.20, and 0.40, respectively). CONCLUSION: We demonstrated that reduced-FOV CINE imaging with SMS+ROVir enables single breath-hold whole-heart imaging without compromising visual image quality or quantitative cardiac function parameters.


Assuntos
Suspensão da Respiração , Imagem Cinética por Ressonância Magnética , Imagem Cinética por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/métodos
8.
Magn Reson Med ; 89(2): 746-755, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36198043

RESUMO

PURPOSE: To determine if contemporary 0.55 T MRI supports the use of contrast-optimal flip angles (FA) for simultaneous multi-slice (SMS) balanced SSFP (bSSFP) cardiac function assessment, which is impractical at conventional field strengths because of excessive SAR and/or banding artifacts. METHODS: Blipped-CAIPI bSSFP was combined with spiral sampling for ventricular function assessment at 0.55 T. Cine movies with single band and SMS factors of 2 and 3 (SMS 2 and 3), and FA ranging from 60° to 160°, were acquired in seven healthy volunteers. Left ventricular blood and myocardial signal intensity (SI) normalized by background noise and blood-myocardium contrast were measured and compared across acquisition settings. RESULTS: Myocardial SI was slightly higher in single band than in SMS and decreased with an increasing FA. Blood SI increased as the FA increased for single band, and increment was small for FA ≥120°. Blood SI for SMS 2 and 3 increased with an increasing FA up to ∼100°. Blood-myocardium contrast increased with an increasing FA for single band, peaked at FA = 160° (systole: 28.43, diastole: 29.15), attributed mainly to reduced myocardial SI when FA ≥120°. For SMS 2, contrast peaked at 120° (systole: 21.43, diastole: 19.85). For SMS 3, contrast peaked at 120° in systole (16.62) and 100° in diastole (19.04). CONCLUSIONS: Contemporary 0.55 T MR scanners equipped with high-performance gradient systems allow the use of contrast-optimal FA for SMS accelerated bSSFP cine examinations without compromising image quality. The contrast-optimal FA was found to be 140° to 160° for single band and 100° to 120° for SMS 2 and 3.


Assuntos
Coração , Interpretação de Imagem Assistida por Computador , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ventrículos do Coração , Miocárdio , Imagem Cinética por Ressonância Magnética/métodos
9.
Int J Hyperthermia ; 40(1): 2194595, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37080550

RESUMO

PURPOSE: In presence of respiratory motion, temperature mapping is altered by in-plane and through-plane displacements between successive acquisitions together with periodic phase variations. Fast 2D Echo Planar Imaging (EPI) sequence can accommodate intra-scan motion, but limited volume coverage and inter-scan motion remain a challenge during free-breathing acquisition since position offsets can arise between the different slices. METHOD: To address this limitation, we evaluated a 2D simultaneous multi-slice EPI sequence with multiband (MB) acceleration during radiofrequency ablation on a mobile gel and in the liver of a volunteer (no heating). The sequence was evaluated in terms of resulting inter-scan motion, temperature uncertainty and elevation, potential false-positive heating and repeatability. Lastly, to account for potential through-plane motion, a 3D motion compensation pipeline was implemented and evaluated. RESULTS: In-plane motion was compensated whatever the MB factor and temperature distribution was found in agreement during both the heating and cooling periods. No obvious false-positive temperature was observed under the conditions being investigated. Repeatability of measurements results in a 95% uncertainty below 2 °C for MB1 and MB2. Uncertainty up to 4.5 °C was reported with MB3 together with the presence of aliasing artifacts. Lastly, fast simultaneous multi-slice EPI combined with 3D motion compensation reduce residual out-of-plane motion. CONCLUSION: Volumetric temperature imaging (12 slices/700 ms) could be performed with 2 °C accuracy or less, and offer tradeoffs in acquisition time or volume coverage. Such a strategy is expected to increase procedure safety by monitoring large volumes more rapidly for MR-guided thermotherapy on mobile organs.


Assuntos
Imagem Ecoplanar , Termometria , Humanos , Imagem Ecoplanar/métodos , Termometria/métodos , Termografia/métodos , Temperatura , Temperatura Corporal , Encéfalo , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador
10.
Pediatr Radiol ; 53(7): 1285-1299, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36255456

RESUMO

Longer examination time, need for anesthesia in smaller children and the inability of most children to hold their breath are major limitations of MRI in pediatric body imaging. Fortunately, with technical advances, many new and upcoming MRI sequences are overcoming these limitations. Advances in data acquisition and k-space sampling methods have enabled sequences with improved temporal and spatial resolution, and minimal artifacts. Sequences to minimize movement artifacts mainly utilize radial k-space filling, and examples include the stack-of-stars method for T1-weighted imaging and the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER)/BLADE method for T2-weighted imaging. Similarly, the sequences with improved temporal resolution and the ability to obtain multiple phases in a single breath-hold in dynamic imaging mainly use some form of partial k-space filling method. New sequences use a variable combination of data sampling methods like compressed sensing, golden-angle radial k-space filling, parallel imaging and partial k-space filling to achieve free-breathing, faster sequences that could be useful for pediatric abdominal and thoracic imaging. Simultaneous multi-slice method has improved diffusion-weighted imaging (DWI) with reduction in scan time and artifacts. In this review, we provide an overview of data sampling methods like parallel imaging, compressed sensing, radial k-space sampling, partial k-space sampling and simultaneous multi-slice. This is followed by newer available and upcoming sequences for T1-, T2- and DWI based on these other advances. We also discuss the Dixon method and newer approaches to reducing metal artifacts.


Assuntos
Meios de Contraste , Processamento de Imagem Assistida por Computador , Humanos , Criança , Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Respiração , Artefatos , Imageamento Tridimensional , Aumento da Imagem/métodos
11.
Neuroimage ; 247: 118820, 2022 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-34920086

RESUMO

Measurement of cerebral blood flow (CBF) using the Arterial Spin Labeling (ASL) technique is a desirable fMRI approach due to the higher specificity of CBF to the site of neural activation. However, ASL has inherent limitations, such as a low signal-to-noise ratio (SNR) and low coverage/resolution due to the limited readout window following the labeling. Recently, ASL has been implemented at ultra-high field (UHF) strengths in an attempt to mitigate the SNR challenges. Even though ASL intrinsically allows concurrent acquisition of CBF and BOLD contrasts, a compromise in the echo time (TE) for either of the contrasts is inevitable with single-echo acquisitions. Long durations of the Cartesian EPI readout do not allow for multi-echo acquisitions for resolutions ≤2 mm where both contrasts can be acquired at their optimal TE at UHF. With its higher acquisition efficiency, single-shot spiral imaging provides a promising alternative to EPI, and with a dual-echo, out-in trajectory allows both CBF and BOLD contrasts to be acquired at their respective optimal TE. In this work, we implemented a dual-echo spiral out-in ASL sequence with simultaneous multi-slice (SMS) readout for increased coverage, and validated its application to fMRI with a visuomotor paradigm. Conventional Cartesian EPI acquisitions with matched parameters served as a reference. The dual-echo spiral ASL acquisitions resulted in robust CBF and BOLD activations maps. The absolute and relative CBF changes measured with the dual-echo spiral readout were in agreement with previous reports in the literature as well as the reference Cartesian acquisitions. The BOLD response amplitude was higher compared to the Cartesian acquisitions, attributable to a more optimal TE of the second echo. In conclusion, dual-echo spiral out-in SMS acquisition shows promise for concurrent acquisitions of BOLD and non-BOLD contrasts that require a short TE, with no loss in temporal resolution.


Assuntos
Circulação Cerebrovascular/fisiologia , Imageamento por Ressonância Magnética/métodos , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador , Oxigênio/sangue , Razão Sinal-Ruído , Marcadores de Spin
12.
Hum Brain Mapp ; 43(3): 955-973, 2022 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-34716738

RESUMO

We wanted to verify the effect of combining multi-echo (ME) functional magnetic resonance imaging (fMRI) with slice acceleration in simultaneous multi-slice acquisition. The aim was to shed light on the benefits of multiple echoes for various acquisition settings, especially for levels of slice acceleration and flip angle. Whole-brain ME fMRI data were obtained from 26 healthy volunteers (using three echoes; seven runs with slice acceleration 1, 4, 6, and 8; and two different flip angles for each of the first three acceleration factors) and processed as single-echo (SE) data and ME data based on optimal combinations weighted by the contrast-to-noise ratio. Global metrics (temporal signal-to-noise ratio, signal-to-noise separation, number of active voxels, etc.) and local characteristics in regions of interest were used to evaluate SE and ME data. ME results outperformed SE results in all runs; the differences became more apparent for higher acceleration, where a significant decrease in data quality is observed. ME fMRI can improve the observed data quality metrics over SE fMRI for a wide range of accelerated fMRI acquisitions.


Assuntos
Mapeamento Encefálico/métodos , Córtex Cerebral/fisiologia , Globo Pálido/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Córtex Cerebral/diagnóstico por imagem , Imagem Ecoplanar/métodos , Feminino , Globo Pálido/diagnóstico por imagem , Humanos , Masculino , Desempenho Psicomotor/fisiologia , Adulto Jovem
13.
Magn Reson Med ; 88(2): 663-675, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35344593

RESUMO

PURPOSE: To implement and evaluate a simultaneous multi-slice balanced SSFP (SMS-bSSFP) perfusion sequence and compressed sensing reconstruction for cardiac MR perfusion imaging with full left ventricular (LV) coverage (nine slices/heartbeat) and high spatial resolution (1.4 × 1.4 mm2 ) at 1.5T. METHODS: A preliminary study was performed to evaluate the performance of blipped controlled aliasing in parallel imaging (CAIPI) and RF-CAIPI with gradient-controlled local Larmor adjustment (GC-LOLA) in the presence of fat. A nine-slice SMS-bSSFP sequence using RF-CAIPI with GC-LOLA with high spatial resolution (1.4 × 1.4 mm2 ) and a conventional three-slice sequence with conventional spatial resolution (1.9 × 1.9 mm2 ) were then acquired in 10 patients under rest conditions. Qualitative assessment was performed to assess image quality and perceived signal-to-noise ratio (SNR) on a 4-point scale (0: poor image quality/low SNR; 3: excellent image quality/high SNR), and the number of myocardial segments with diagnostic image quality was recorded. Quantitative measurements of myocardial sharpness and upslope index were performed. RESULTS: Fat signal leakage was significantly higher for blipped CAIPI than for RF-CAIPI with GC-LOLA (7.9% vs. 1.2%, p = 0.010). All 10 SMS-bSSFP perfusion datasets resulted in 16/16 diagnostic myocardial segments. There were no significant differences between the SMS and conventional acquisitions in terms of image quality (2.6 ± 0.6 vs. 2.7 ± 0.2, p = 0.8) or perceived SNR (2.8 ± 0.3 vs. 2.7 ± 0.3, p = 0.3). Inter-reader variability was good for both image quality (ICC = 0.84) and perceived SNR (ICC = 0.70). Myocardial sharpness was improved using the SMS sequence compared to the conventional sequence (0.37 ± 0.08 vs 0.32 ± 0.05, p < 0.001). There was no significant difference between measurements of upslope index for the SMS and conventional sequences (0.11 ± 0.04 vs. 0.11 ± 0.03, p = 0.84). CONCLUSION: SMS-bSSFP with multiband factor 3 and compressed sensing reconstruction enables cardiac MR perfusion imaging with three-fold increased spatial coverage and improved myocardial sharpness compared to a conventional sequence, without compromising perceived SNR, image quality, upslope index or number of diagnostic segments.


Assuntos
Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Ventrículos do Coração/diagnóstico por imagem , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Perfusão , Reprodutibilidade dos Testes
14.
Magn Reson Med ; 87(5): 2239-2253, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35014727

RESUMO

PURPOSE: Quantitative MRI (qMRI) is of great importance to clinical medicine and scientific research. However, most qMRI techniques are time-consuming and sensitive to motion, especially when a large 3D volume is imaged. To accelerate the acquisition, a framework is proposed to realize reliable simultaneous multi-slice T2 mapping. METHODS: The simultaneous multi-slice T2 mapping framework is based on overlapping-echo detachment (OLED) planar imaging (dubbed SMS-OLED). Multi-slice overlapping-echo signals were generated by multiple excitation pulses together with echo-shifting gradients. The signals were excited and acquired with a single-channel coil. U-Net was used to reconstruct T2 maps from the acquired overlapping-echo image. RESULTS: Single-shot double-slice and two-shot triple-slice SMS-OLED scan schemes were designed according to the framework for evaluation. Simulations, water phantom, and in vivo rat brain experiments were carried out. Overlapping-echo signals were acquired, and T2 maps were reconstructed and compared with references. The results demonstrate the superior performance of our method. CONCLUSION: Two slices of T2 maps can be obtained in a single shot within hundreds of milliseconds. Higher quality multi-slice T2 maps can be obtained via multiple shots. SMS-OLED provides a lower specific absorption rate scheme compared with conventional SMS methods with a coil with only a single receiver channel. The new method is of potential in dynamic qMRI and functional qMRI where temporal resolution is vital.


Assuntos
Aprendizado Profundo , Algoritmos , Animais , Encéfalo/diagnóstico por imagem , Imagem Ecoplanar/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Ratos
15.
Magn Reson Med ; 87(6): 2697-2709, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35092081

RESUMO

PURPOSE: To accelerate the acquisition of relaxation-diffusion imaging by integrating time-division multiplexing (TDM) with simultaneous multi-slice (SMS) for EPI and evaluate imaging quality and diffusion measures. METHODS: The time-division multiplexing (TDM) technique and SMS method were integrated to achieve a high slice-acceleration (e.g., 6×) factor for acquiring relaxation-diffusion MRI. Two variants of the sequence, referred to as TDM3e-SMS and TDM2s-SMS, were developed to simultaneously acquire slice groups with three distinct TEs and two slice groups with the same TE, respectively. Both sequences were evaluated on a 3T scanner with in vivo human brains and compared with standard single-band (SB) -EPI and SMS-EPI using diffusion measures and tractography results. RESULTS: Experimental results showed that the TDM3e-SMS sequence with total slice acceleration of 6 (multiplexing factor (MP) = 3 × multi-band factor (MB) = 2) provided similar image intensity and microstructure measures compared to standard SMS-EPI with MB = 2, and yielded less bias in intensity compared to standard SMS-EPI with MB = 4. The three sequences showed a similar positive correlation between TE and mean kurtosis (MK) and a negative correlation between TE and mean diffusivity (MD) in white matter. Multi-fiber tractography also shows consistency of results in TE-dependent measures between different sequences. The TDM2s-SMS sequence (MP = 2, MB = 2) also provided imaging measures similar to standard SMS-EPI sequences (MB = 2) for single-TE diffusion imaging. CONCLUSIONS: The TDM-SMS sequence can provide additional 2× to 3× acceleration to SMS without degrading imaging quality. With the significant reduction in scan time, TDM-SMS makes joint relaxation-diffusion MRI a feasible technique in neuroimaging research to investigate new markers of brain disorders.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Aceleração , Encéfalo/diagnóstico por imagem , Difusão , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos
16.
Neuroimage ; 226: 117539, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33186723

RESUMO

Diffusion-weighted magnetic resonance imaging (dMRI) has found great utility for a wide range of neuroscientific and clinical applications. However, high-resolution dMRI, which is required for improved delineation of fine brain structures and connectomics, is hampered by its low signal-to-noise ratio (SNR). Since dMRI relies on the acquisition of multiple different diffusion weighted images of the same anatomy, it is well-suited for denoising methods that utilize correlations across the image series to improve the apparent SNR and the subsequent data analysis. In this work, we introduce and quantitatively evaluate a comprehensive framework, NOise Reduction with DIstribution Corrected (NORDIC) PCA method for processing dMRI. NORDIC uses low-rank modeling of g-factor-corrected complex dMRI reconstruction and non-asymptotic random matrix distributions to remove signal components which cannot be distinguished from thermal noise. The utility of the proposed framework for denoising dMRI is demonstrated on both simulations and experimental data obtained at 3 Tesla with different resolutions using human connectome project style acquisitions. The proposed framework leads to substantially enhanced quantitative performance for estimating diffusion tractography related measures and for resolving crossing fibers as compared to a conventional/state-of-the-art dMRI denoising method.


Assuntos
Artefatos , Encéfalo/anatomia & histologia , Conectoma/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Humanos , Razão Sinal-Ruído
17.
Magn Reson Med ; 85(6): 3272-3280, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33331002

RESUMO

PURPOSE: Simultaneous multi-slice acquisitions are essential for modern neuroimaging research, enabling high temporal resolution functional and high-resolution q-space sampling diffusion acquisitions. Recently, deep learning reconstruction techniques have been introduced for unaliasing these accelerated acquisitions, and robust artificial-neural-networks for k-space interpolation (RAKI) have shown promising capabilities. This study systematically examines the impacts of hyperparameter selections for RAKI networks, and introduces a novel technique for training data generation which is analogous to the split-slice formalism used in slice-GRAPPA. METHODS: RAKI networks were developed with variable hyperparameters and with and without split-slice training data generation. Each network was trained and applied to five different datasets including acquisitions harmonized with Human Connectome Project lifespan protocol. Unaliasing performance was assessed through L1 errors computed between unaliased and calibration frequency-space data. RESULTS: Split-slice training significantly improved network performance in nearly all hyperparameter configurations. Best unaliasing results were achieved with three layer RAKI networks using at least 64 convolutional filters with receptive fields of 7 voxels, 128 single-voxel filters in the penultimate RAKI layer, batch normalization, and no training dropout with the split-slice augmented training dataset. Networks trained without the split-slice technique showed symptoms of network over-fitting. CONCLUSIONS: Split-slice training for simultaneous multi-slice RAKI networks positively impacts network performance. Hyperparameter tuning of such reconstruction networks can lead to further improvements in unaliasing performance.


Assuntos
Processamento de Imagem Assistida por Computador , Redes Neurais de Computação , Calibragem , Humanos
18.
Magn Reson Med ; 86(2): 663-676, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33749026

RESUMO

PURPOSE: To enable all-systolic first-pass rest myocardial perfusion with long saturation times. To investigate the change in perfusion contrast and dark rim artefacts through simulations and surrogate measurements. METHODS: Simulations were employed to investigate optimal saturation time for myocardium-perfusion defect contrast and blood-to-myocardium signal ratios. Two saturation recovery blocks with long/short saturation times (LTS/STS) were employed to image 3 slices at end-systole and diastole. Simultaneous multi-slice balanced steady state free precession imaging and compressed sensing acceleration were combined. The sequence was compared to a 3 slice-by-slice clinical protocol in 10 patients. Quantitative assessment of myocardium-peak pre contrast and blood-to-myocardium signal ratios, as well as qualitative assessment of perceived SNR, image quality, blurring, and dark rim artefacts, were performed. RESULTS: Simulations showed that with a bolus of 0.075 mmol/kg, a LTS of 240-470 ms led to a relative increase in myocardium-perfusion defect contrast of 34% ± 9%-28% ± 27% than a STS = 120 ms, while reducing blood-to-myocardium signal ratio by 18% ± 10%-32% ± 14% at peak myocardium. With a bolus of 0.05 mmol/kg, LTS was 320-570 ms with an increase in myocardium-perfusion defect contrast of 63% ± 13%-62% ± 29%. Across patients, LTS led to an average increase in myocardium-peak pre contrast of 59% (P < .001) at peak myocardium and a lower blood-to-myocardium signal ratio of 47% (P < .001) and 15% (P < .001) at peak blood/myocardium. LTS had improved motion robustness (P = .002), image quality (P < .001), and decreased dark rim artefacts (P = .008) than the clinical protocol. CONCLUSION: All-systolic rest perfusion can be achieved by combining simultaneous multi-slice and compressed sensing acceleration, enabling 3-slice cardiac coverage with reduced motion and dark rim artefacts. Numerical simulations indicate that myocardium-perfusion defect contrast increases at LTS.


Assuntos
Imageamento por Ressonância Magnética , Imagem de Perfusão do Miocárdio , Aceleração , Meios de Contraste , Coração/diagnóstico por imagem , Humanos , Perfusão , Sístole
19.
Magn Reson Med ; 86(2): 648-662, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33709415

RESUMO

PURPOSE: To develop and evaluate a high spatial resolution (1.25 × 1.25 mm2 ) spiral first-pass myocardial perfusion imaging technique with whole-heart coverage at 3T, to better assess transmural differences in perfusion between the endocardium and epicardium, to quantify the myocardial ischemic burden, and to improve the detection of obstructive coronary artery disease. METHODS: Whole-heart high-resolution spiral perfusion pulse sequences and corresponding motion-compensated reconstruction techniques for both interleaved single-slice (SS) and simultaneous multi-slice (SMS) acquisition with or without outer-volume suppression (OVS) were developed. The proposed techniques were evaluated in 34 healthy volunteers and 8 patients (55 data sets). SS and SMS images were reconstructed using motion-compensated L1-SPIRiT and SMS-Slice-L1-SPIRiT, respectively. Images were blindly graded by 2 experienced cardiologists on a 5-point scale (5, excellent; 1, poor). RESULTS: High-quality perfusion imaging was achieved for both SS and SMS acquisitions with or without OVS. The SS technique without OVS had the highest scores (4.5 [4, 5]), which were greater than scores for SS with OVS (3.5 [3.25, 3.75], P < .05), MB = 2 without OVS (3.75 [3.25, 4], P < .05), and MB = 2 with OVS (3.75 [2.75, 4], P < .05), but significantly higher than those for MB = 3 without OVS (4 [4, 4], P = .95). SMS image quality was improved using SMS-Slice-L1-SPIRiT as compared to SMS-L1-SPIRiT (P < .05 for both reviewers). CONCLUSION: We demonstrated the successful implementation of whole-heart spiral perfusion imaging with high resolution at 3T. Good image quality was achieved, and the SS without OVS showed the best image quality. Evaluation in patients with expected ischemic heart disease is warranted.


Assuntos
Imagem de Perfusão do Miocárdio , Humanos , Processamento de Imagem Assistida por Computador , Movimento (Física) , Imagem de Perfusão , Pericárdio
20.
Magn Reson Med ; 85(3): 1258-1271, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32936487

RESUMO

PURPOSE: To develop a single-shot multi-slice T1 mapping method by combing simultaneous multi-slice (SMS) excitations, single-shot inversion-recovery (IR) radial fast low-angle shot (FLASH), and a nonlinear model-based reconstruction method. METHODS: SMS excitations are combined with a single-shot IR radial FLASH sequence for data acquisition. A previously developed single-slice calibrationless model-based reconstruction is extended to SMS, formulating the estimation of parameter maps and coil sensitivities from all slices as a single nonlinear inverse problem. Joint-sparsity constraints are further applied to the parameter maps to improve T1 precision. Validations of the proposed method are performed for a phantom and for the human brain and liver in 6 healthy adult subjects. RESULTS: Phantom results confirm good T1 accuracy and precision of the simultaneously acquired multi-slice T1 maps in comparison to single-slice references. In vivo human brain studies demonstrate the better performance of SMS acquisitions compared to the conventional spoke-interleaved multi-slice acquisition using model-based reconstruction. Aside from good accuracy and precision, the results of 6 healthy subjects in both brain and abdominal studies confirm good repeatability between scan and re-scans. The proposed method can simultaneously acquire T1 maps for 5 slices of a human brain ( 0.75×0.75×5mm3 ) or 3 slices of the abdomen ( 1.25×1.25×6mm3 ) within 4 seconds. CONCLUSIONS: The IR SMS radial FLASH acquisition together with a nonlinear model-based reconstruction enable rapid high-resolution multi-slice T1 mapping with good accuracy, precision, and repeatability.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Adulto , Algoritmos , Encéfalo/diagnóstico por imagem , Humanos , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA