Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Neuroimage ; 288: 120523, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38278427

RESUMO

Although manganese (Mn) is a trace metal essential for humans, chronic exposure to Mn can cause accumulation of this metal ion in the brain leading to an increased risk of neurological and neurobehavioral health effects. This is a concern for welders exposed to Mn through welding fumes. While brain Mn accumulation in occupational settings has mostly been reported in the basal ganglia, several imaging studies also revealed elevated Mn in other brain areas. Since Mn functions as a magnetic resonance imaging (MRI) T1 contrast agent, we developed a whole-brain MRI approach to map in vivo Mn deposition differences in the brains of non-exposed factory controls and exposed welders. This is a cross-sectional analysis of 23 non-exposed factory controls and 36 exposed full-time welders from the same truck manufacturer. We collected high-resolution 3D MRIs of brain anatomy and R1 relaxation maps to identify regional differences using voxel-based quantification (VBQ) and statistical parametric mapping. Furthermore, we investigated the associations between excess Mn deposition and neuropsychological and motor test performance. Our results indicate that: (1) Using whole-brain MRI relaxometry methods we can generate excess Mn deposition maps in vivo, (2) excess Mn accumulation due to occupational exposure occurs beyond the basal ganglia in cortical areas associated with motor and cognitive functions, (3) Mn likely diffuses along white matter tracts in the brain, and (4) Mn deposition in specific brain regions is associated with exposure (cerebellum and frontal cortex) and motor metrics (cerebellum and hippocampus).


Assuntos
Manganês , Ferreiros , Humanos , Estudos Transversais , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Mapeamento Encefálico
2.
Magn Reson Med ; 92(1): 158-172, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38411277

RESUMO

PURPOSE: Abnormalities in cerebral veins are a common finding in many neurological diseases, yet there is a scarcity of MRI techniques to assess venous hemodynamic function. The present study aims to develop a noncontrast technique to measure a novel blood flow circulatory measure, venous transit time (VTT), which denotes the time it takes for water to travel from capillary to major veins. METHODS: The proposed sequence, venous transit time imaging by changes in T1 relaxation (VICTR), is based on the notion that as water molecules transition from the tissue into the veins, they undergo a change in T1 relaxation time. The validity of the measured VTT was tested by studying the VTT along the anatomically known flow trajectory of venous vessels as well as using a physiological vasoconstrictive challenge of caffeine ingestion. Finally, we compared the VTT measured with VICTR MRI to a bolus-tracking method using gadolinium-based contrast agent. RESULTS: VTT was measured to be 3116.3 ± 326.0 ms in the posterior superior sagittal sinus (SSS), which was significantly longer than 2865.0 ± 390.8 ms at the anterior superior sagittal sinus (p = 0.004). The test-retest assessment showed an interclass correlation coefficient of 0.964. VTT was significantly increased by 513.8 ± 239.3 ms after caffeine ingestion (p < 0.001). VTT measured with VICTR MRI revealed a strong correlation (R = 0.84, p = 0.002) with that measured with the contrast-based approach. VTT was found inversely correlated to cerebral blood flow and venous oxygenation across individuals. CONCLUSION: A noncontrast MRI technique, VICTR MRI, was developed to measure the VTT of the brain.


Assuntos
Veias Cerebrais , Imageamento por Ressonância Magnética , Humanos , Masculino , Adulto , Feminino , Velocidade do Fluxo Sanguíneo/fisiologia , Veias Cerebrais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Circulação Cerebrovascular/fisiologia , Reprodutibilidade dos Testes , Cafeína/farmacologia , Meios de Contraste , Adulto Jovem , Processamento de Imagem Assistida por Computador/métodos , Hemodinâmica , Angiografia por Ressonância Magnética/métodos
3.
Magn Reson Med ; 92(1): 57-68, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38308151

RESUMO

PURPOSE: To investigate the effect of inhaled oxygen level on dynamic glucose enhanced (DGE) MRI in mouse brain tissue and CSF at 3 T. METHODS: DGE data of brain tissue and CSF from mice under normoxia or hyperoxia were acquired in independent and interleaved experiments using on-resonance variable delay multi-pulse (onVDMP) MRI. A bolus of 0.15 mL filtered 50% D-glucose was injected through the tail vein over 1 min during DGE acquisition. MRS was acquired before and after DGE experiments to confirm the presence of D-glucose. RESULTS: A significantly higher DGE effect under normoxia than under hyperoxia was observed in brain tissue (p = 0.0001 and p = 0.0002 for independent and interleaved experiments, respectively), but not in CSF (p > 0.3). This difference is attributed to the increased baseline MR tissue signal under hyperoxia induced by a shortened T1 and an increased BOLD effect. When switching from hyperoxia to normoxia without glucose injection, a signal change of ˜3.0% was found in brain tissue and a signal change of ˜1.5% was found in CSF. CONCLUSIONS: DGE signal was significantly lower under hyperoxia than that under normoxia in brain tissue, but not in CSF. The reason is that DGE effect size of brain tissue is affected by the baseline signal, which could be influenced by T1 change and BOLD effect. Therefore, DGE experiments in which the oxygenation level is changed from baseline need to be interpreted carefully.


Assuntos
Encéfalo , Glucose , Hiperóxia , Imageamento por Ressonância Magnética , Oxigênio , Animais , Camundongos , Imageamento por Ressonância Magnética/métodos , Glucose/metabolismo , Oxigênio/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Hiperóxia/diagnóstico por imagem , Administração por Inalação , Masculino , Camundongos Endogâmicos C57BL
4.
NMR Biomed ; : e5152, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565525

RESUMO

Relaxation correction is an integral step in quantifying brain metabolite concentrations measured by in vivo magnetic resonance spectroscopy (MRS). While most quantification routines assume constant T1 relaxation across age, it is possible that aging alters T1 relaxation rates, as is seen for T2 relaxation. Here, we investigate the age dependence of metabolite T1 relaxation times at 3 T in both gray- and white-matter-rich voxels using publicly available metabolite and metabolite-nulled (single inversion recovery TI = 600 ms) spectra acquired at 3 T using Point RESolved Spectroscopy (PRESS) localization. Data were acquired from voxels in the posterior cingulate cortex (PCC) and centrum semiovale (CSO) in 102 healthy volunteers across 5 decades of life (aged 20-69 years). All spectra were analyzed in Osprey v.2.4.0. To estimate T1 relaxation times for total N-acetyl aspartate at 2.0 ppm (tNAA2.0) and total creatine at 3.0 ppm (tCr3.0), the ratio of modeled metabolite residual amplitudes in the metabolite-nulled spectrum to the full metabolite signal was calculated using the single-inversion-recovery signal equation. Correlations between T1 and subject age were evaluated. Spearman correlations revealed that estimated T1 relaxation times of tNAA2.0 (rs = -0.27; p < 0.006) and tCr3.0 (rs = -0.40; p < 0.001) decreased significantly with age in white-matter-rich CSO, and less steeply for tNAA2.0 (rs = -0.228; p = 0.005) and (not significantly for) tCr3.0 (rs = -0.13; p = 0.196) in graymatter-rich PCC. The analysis harnessed a large publicly available cross-sectional dataset to test an important hypothesis, that metabolite T1 relaxation times change with age. This preliminary study stresses the importance of further work to measure age-normed metabolite T1 relaxation times for accurate quantification of metabolite levels in studies of aging.

5.
J Cardiovasc Magn Reson ; 26(2): 101046, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38810732

RESUMO

BACKGROUND: Three-dimensional (3D) contrast-enhanced magnetic resonance angiography (CEMRA) is routinely used for vascular evaluation. With existing techniques for CEMRA, diagnostic image quality is only obtained during the first pass of the contrast agent or shortly thereafter, whereas angiographic quality tends to be poor when imaging is delayed to the equilibrium phase. We hypothesized that prolonged blood pool contrast enhancement could be obtained by imaging with a balanced T1 relaxation-enhanced steady-state (bT1RESS) pulse sequence, which combines 3D balanced steady-state free precession (bSSFP) with a saturation recovery magnetization preparation to impart T1 weighting and suppress background tissues. An electrocardiographic-gated, two-dimensional-accelerated version with isotropic 1.1-mm spatial resolution was evaluated for breath-hold equilibrium phase CEMRA of the thoracic aorta and heart. METHODS: The study was approved by the institutional review board. Twenty-one subjects were imaged using unenhanced 3D bSSFP, time-resolved CEMRA, first-pass gated CEMRA, followed by early and late equilibrium phase gated CEMRA and bT1RESS. Nine additional subjects were imaged using equilibrium phase 3D bSSFP and bT1RESS. Images were evaluated for image quality, aortic root sharpness, and visualization of the coronary artery origins, as well as using standard quantitative measures. RESULTS: Equilibrium phase bT1RESS provided better image quality, aortic root sharpness, and coronary artery origin visualization than gated CEMRA (P < 0.05), and improved image quality and aortic root sharpness versus unenhanced 3D bSSFP (P < 0.05). It provided significantly larger apparent signal-to-noise and apparent contrast-to-noise ratio values than gated CEMRA and unenhanced 3D bSSFP (P < 0.05) and provided ninefold better fluid suppression than equilibrium phase 3D bSSFP. Aortic diameter and main pulmonary artery diameter measurements obtained with bT1RESS and first-pass gated CEMRA strongly correlated (P < 0.05). CONCLUSIONS: We found that using bT1RESS greatly prolongs the useful duration of blood pool contrast enhancement while improving angiographic image quality compared with standard CEMRA techniques. Although further study is needed, potential advantages for vascular imaging include eliminating the current requirement for first-pass imaging along with better reliability and accuracy for a wide range of cardiovascular applications.

6.
Cereb Cortex ; 33(7): 3562-3574, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-35945683

RESUMO

Quantitative magnetic resonance (MR) has been used to study cyto- and myelo-architecture of the human brain non-invasively. However, analyzing brain cortex using high-resolution quantitative MR acquisition can be challenging to perform using 3T clinical scanners. MR fingerprinting (MRF) is a highly efficient and clinically feasible quantitative MR technique that simultaneously provides T1 and T2 relaxation maps. Using 3D MRF from 40 healthy subjects (mean age = 25.6 ± 4.3 years) scanned on 3T magnetic resonance imaging, we generated whole-brain gyral-based normative MR relaxation atlases and investigated cortical-region-based T1 and T2 variations. Gender and age dependency of T1 and T2 variations were additionally analyzed. The coefficient of variation of T1 and T2 for each cortical-region was 3.5% and 7.3%, respectively, supporting low variability of MRF measurements across subjects. Significant differences in T1 and T2 were identified among 34 brain regions (P < 0.001), lower in the precentral, postcentral, paracentral lobule, transverse temporal, lateral occipital, and cingulate areas, which contain sensorimotor, auditory, visual, and limbic functions. Significant correlations were identified between age and T1 and T2 values. This study established whole-brain MRF T1 and T2 atlases of healthy subjects using a clinical 3T scanner, which can provide a quantitative and region-specific baseline for future brain studies and pathology detection.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Adulto Jovem , Adulto , Lactente , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Voluntários Saudáveis , Processamento de Imagem Assistida por Computador/métodos
7.
Magn Reson Chem ; 62(3): 190-197, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38237932

RESUMO

Since 1993, it has been known that 13 C chemical shift tensor (i.e., δ11 , δ22 , and δ33 ) provides information sufficient to distinguish between COOH and COO- sites. Herein, four previously unreported metrics are proposed for differentiating COOH/COO- moieties. A new relationship is also introduced that correlates the asymmetry (i.e., δ11 -δ22 ) of COOH sites to the proximity of hydrogen bond donating partners within 2.6 Å with high accuracy (±0.05 Å). Conversely, a limitation to all proposed metrics is that they fail to distinguish between COO- and hydrogen disordered COOH sites. To reconcile this omission, a new approach is proposed based on T1 measurements of both 1 H and 13 C. The 13 C T1 values are particularly sensitive with the T1 for hydrogen disordered COOH moieties found to be nearly six times smaller than T1 's from COO- sites.

8.
Magn Reson Med ; 90(2): 708-721, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37145027

RESUMO

PURPOSE: Recent studies indicate that T1 in white matter (WM) is influenced by fiber orientation in B0 . The purpose of the study was to investigate the interrelationships between axon fiber orientation in corpus callosum (CC) and T1 relaxation time in humans in vivo as well as in rat brain ex vivo. METHODS: Volunteers were scanned for relaxometric and diffusion MRI at 3 T and 7 T. Angular T1 plots from WM were computed using fractional anisotropy and fiber-to-field-angle maps. T1 and fiber-to-field angle were measured in five sections of CC to estimate the effects of inherently varying fiber orientations on T1 within the same tracts in vivo. Ex vivo rat-brain preparation encompassing posterior CC was rotated in B0 and T1 , and diffusion MRI images acquired at 9.4 T. T1 angular plots were determined at several rotation angles in B0 . RESULTS: Angular T1 plots from global WM provided reference for estimated fiber orientation-linked T1 changes within CC. In anterior midbody of CC in vivo, where small axons are dominantly present, a shift in axon orientation is accompanied by a change in T1 , matching that estimated from WM T1 data. In CC, where large and giant axons are numerous, the measured T1 change is about 2-fold greater than the estimated one. Ex vivo rotation of the same midsagittal CC region of interest produced angular T1 plots at 9.4 T, matching those observed at 7 T in vivo. CONCLUSION: These data causally link axon fiber orientation in B0 to the T1 relaxation anisotropy in WM.


Assuntos
Substância Branca , Humanos , Substância Branca/diagnóstico por imagem , Corpo Caloso/diagnóstico por imagem , Anisotropia , Axônios , Imagem de Difusão por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem
9.
Magn Reson Med ; 90(1): 11-20, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36807934

RESUMO

PURPOSE: The purpose of this study was to characterize the 1 H downfield MR spectrum from 8.0 to 10.0 ppm of human skeletal muscle at 7 T and determine the T1 and cross-relaxation rates of observed resonances. METHODS: We performed downfield MRS in the calf muscle of 7 healthy volunteers. Single-voxel downfield MRS was collected using alternately selective or broadband inversion-recovery sequences and spectrally selective 90° E-BURP RF pulse excitation centered at 9.0 ppm with bandwidth = 600 Hz (2.0 ppm). MRS was collected using TIs of 50-2500 ms. We modeled recovery of the longitudinal magnetization of three observable resonances using two models: (1) a three-parameter model accounting for the apparent T1 recovery and (2) a Solomon model explicitly including cross-relaxation effects. RESULTS: Three resonances were observed in human calf muscle at 7 T at 8.0, 8.2, and 8.5 ppm. We found broadband (broad) and selective (sel) inversion recovery T1 = mean ± SD (ms): T1-broad,8.0ppm = 2108.2 ± 664.5, T1-sel,8.0ppm = 753.6 ± 141.0 (p = 0.003); T1-broad,8.2ppm = 2033.5 ± 338.4, T1-sel,8.2ppm = 135.3 ± 35.3 (p < 0.0001); and T1-broad,8.5ppm = 1395.4 ± 75.4, T1-sel,8.5ppm = 107.1 ± 40.0 (p < 0.0001). Using the Solomon model, we found T1 = mean ± SD (ms): T1-8.0ppm = 1595.6 ± 491.1, T1-8.2ppm = 1737.2 ± 963.7, and T1-8.5ppm = 849.8 ± 282.0 (p = 0.04). Post hoc tests corrected for multiple comparisons showed no significant difference in T1 between peaks. The cross-relaxation rate σAB = mean ± SD (Hz) of each peak was σAB,8.0ppm = 0.76 ± 0.20, σAB,8.2ppm = 5.31 ± 2.27, and σAB,8.5ppm = 7.90 ± 2.74 (p < 0.0001); post hoc t-tests revealed the cross-relaxation rate of the 8.0 ppm peak was significantly slower than the peaks at 8.2 ppm (p = 0.0018) and 8.5 ppm (p = 0.0005). CONCLUSION: We found significant differences in effective T1 and cross-relaxation rates of 1 H resonances between 8.0 and 8.5 ppm in the healthy human calf muscle at 7 T.


Assuntos
Músculo Esquelético , Humanos , Espectroscopia de Ressonância Magnética , Músculo Esquelético/diagnóstico por imagem
10.
NMR Biomed ; 36(1): e4815, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35994269

RESUMO

A high degree of structural order by white matter (WM) fibre tracts creates a physicochemical environment where water relaxations are rendered anisotropic. Recently, angularly dependent longitudinal relaxation has been reported in human WM. We have characterised interrelationships between T1 relaxation and diffusion MRI microstructural indices at 3 and 7 T. Eleven volunteers consented to participate in the study. Multishell diffusion MR images were acquired with b-values of 0/1500/3000 and 0/1000/2000 s/mm2 at 1.5 and 1.05 mm3 isotropic resolutions at 3 and 7 T, respectively. DTIFIT was used to compute DTI indices; the fibre-to-field angle (θFB ) maps were obtained using the principal eigenvector images. The orientations and volume fractions of multiple fibre populations were estimated using BedpostX in FSL, and the orientation dispersion index (ODI) was estimated using the NODDI protocol. MP2RAGE was used to acquire images for T1 maps at 1.0 and 0.9 mm3 isotropic resolutions at 3 and 7 T, respectively. At 3 T, T1 as a function of θFB in WM with high fractional anisotropy and one-fibre orientation volume fraction or low ODI shows a broad peak centred at 50o , but a flat baseline at 0o and 90o . The broad peak amounted up to 7% of the mean T1. At 7 T, the broad peak appeared at 40o and T1 in fibres running parallel to B0 was longer by up to 75 ms (8.3% of the mean T1) than in those perpendicular to the field. The peak at 40o was approximately 5% of mean T1 (i.e., proportionally smaller than that at 54o at 3 T). The data demonstrate T1 anisotropy in WM with high microstructural order at both fields. The angular patterns are indicative of the B0-dependency of T1 anisotropy. Thus myelinated WM fibres influence T1 contrast both by acting as a T1 contrast agent and rendering T1 dependent on fibre orientation with B0.


Assuntos
Substância Branca , Humanos , Substância Branca/diagnóstico por imagem
11.
NMR Biomed ; 36(5): e4873, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36347826

RESUMO

T1 relaxation times of the 14 T1 phantom spheres that make up the standard International Society for Magnetic Resonance in Medicine (ISMRM)/National Institute of Standards and Technology (NIST) system phantom are reported at 7 T. T1 values of six of the 14 T1 spheres at 7 T (with T1 > 270 ms) have been reported previously, but, to the best of our knowledge, not all of the T1s of the 14 T1 spheres at 7 T have been reported before. Given the increasing number of 7-T MRI systems in clinical settings and the increasing need for T1 phantoms that cover a wide range of T1 relaxation times to evaluate rapid T1 mapping techniques at 7 T, it is of high interest to obtain accurate T1 values for all the ISMRM/NIST T1 spheres at 7 T. In this work, T1 relaxation time was measured on a 7-T MRI scanner using an inversion-recovery spin-echo pulse sequence and derived by curve fitting to a signal equation that exhibits insensitivity to B 1 + inhomogeneity. Day-to-day reproducibility was within 0.4% and differences between two different RF coils within 1.5%. T1s of a subset of the 14 spheres were also measured by NMR at 7 T for comparison, and the T1 results were consistent between the MRI and NMR measurements. T1 measurements performed at 3 T on the same 14 spheres using the same sequence and fitting method yielded good agreement (mean percentage difference of -0.4%) with the reference T1 values available from the NIST, reflecting the accuracy of the reported technique despite being without the standard phantom housing. We found that the T1 values of all 14 NiCl2 spheres are consistently lower at 7 T than at 3 T. Although our results were well reproduced, this study represents initial work to quantify the 7-T T1 values of all 14 NIST T1 spheres outside of the standard housing and does not warrant reproducibility of the ISMRM/NIST system phantom as a whole. A future study to assess the T1 values of a version of the ISMRM/NIST system phantom that fits inside typical commercial coils at 7 T will be very helpful. Nonetheless, the details on our acquisition and curve-fitting methods reported here allow the T1 measurements to be reproduced elsewhere. The T1 values of all 14 spheres reported here will be valuable for the development of quantitative MR fingerprinting and rapid T1 mapping for a large variety of research projects, not only in neuroimaging but also in body MRI, musculoskeletal MRI, and gadolinium contrast-enhanced MRI, each of which is concerned with much shortened T1.


Assuntos
Imageamento por Ressonância Magnética , Neuroimagem , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Valores de Referência
12.
J Magn Reson Imaging ; 57(6): 1805-1812, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36190187

RESUMO

BACKGROUND: Magnetic resonance fingerprinting (MRF) techniques have been recently described for simultaneous multiparameter cartilage mapping of the knee although investigation of their ability to detect early cartilage degeneration remains limited. PURPOSE: To investigate age-dependent changes in knee cartilage T1 , T2 , and T1p relaxation times measured using a three-dimensional (3D) MRF sequence in healthy volunteers. STUDY TYPE: Prospective. SUBJECTS: The study group consisted of 24 healthy asymptomatic human volunteers (15 males with mean age 34.9 ± 14.4 years and 9 females with mean age 44.5 ± 13.1 years). FIELD STRENGTH/SEQUENCE: A 3.0 T gradient-echo-based 3D-MRF sequence was used to simultaneously create proton density-weighted images and T1 , T2 , and T1p maps of knee cartilage. ASSESSMENT: Mean global cartilage and regional cartilage (lateral femur, lateral tibia, medial femur, medial tibia, and patella) T1 , T2 , and T1ρ relaxation times of the knee were measured. STATISTICAL TESTS: Kruskal-Wallis tests were used to compared cartilage T1 , T2 , and T1ρ relaxation times between different age groups, while Spearman correlation coefficients was used to determine the association between age and cartilage T1 , T2 , and T1ρ relaxation times. The value of P < 0.05 was considered statistically significant. RESULTS: Higher age groups showed higher global and regional cartilage T1 , T2 , and T1ρ . There was a significant difference between age groups in global cartilage T2 and T1ρ but no significant difference (P = 0.13) in global cartilage T1. Significant difference was also present between age groups in cartilage T2 and T1ρ for medial femur cartilage and medial tibia cartilage. There were significant moderate correlations between age and T2 and T1ρ for global cartilage (R2  = 0.63-0.64), medial femur cartilage (R2  = 0.50-0.56), and medial tibia cartilage (R2  = 0.54-0.66). CONCLUSION: Cartilage T2 and T1p relaxation times simultaneously measured using a 3D-MRF sequence in healthy volunteers showed age-dependent changes in knee cartilage, primarily within the medial compartment.


Assuntos
Cartilagem Articular , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Estudos Prospectivos , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/patologia , Joelho , Imageamento por Ressonância Magnética/métodos
13.
J Magn Reson Imaging ; 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37950398

RESUMO

BACKGROUND: The widely used magnetization-prepared rapid gradient-echo (MPRAGE) sequence makes enhancing lesions and blood vessels appear bright after gadolinium administration. However, dark blood imaging using T1-weighted Sampling Perfection with Application optimized Contrast using different flip angle Evolution (T1 SPACE) can be advantageous since it improves the conspicuity of small metastases and leptomeningeal disease. As a potential alternative to T1 SPACE, we evaluated a new dark blood sequence called echo-uT1 RESS (unbalanced T1 Relaxation-Enhanced Steady-State). PURPOSE: We compared the performance of echo-uT1 RESS with Dixon fid-uT1 RESS, MPRAGE, and T1 SPACE. STUDY TYPE: Retrospective, IRB approved. SUBJECTS/PHANTOM: Phantom to assess flow properties of echo-uT1 RESS. Twenty-one patients (14 female, age range 35-82 years) with primary and secondary brain tumors. FIELD STRENGTH/SEQUENCES: 3 Tesla/MPRAGE, T1 SPACE, Dixon fid-uT1 RESS, echo-uT1 RESS. ASSESSMENT: Flow phantom signal vs. velocity as a function of flip angle and sequence. Qualitative image assessment on 4-point scale. Quantitative evaluation of tumor-to-brain contrast, apparent contrast-to-noise ratio (aCNR), and vessel-to-brain aCNR. STATISTICAL TESTS: Friedman and Mann-Whitney U tests. A P value <0.05 was considered statistically significant. RESULTS: In the phantom, echo-uT1 RESS showed greater flow-dependent signal loss than fid-uT1 RESS. In patients, blood vessels appeared bright with MPRAGE, gray with fid-uT1 RESS, and dark with T1 SPACE and echo-uT1 RESS. For MPRAGE, Dixon fid-uT1 RESS, echo-uT1 RESS, and T1 SPACE, respective tumor-to-brain contrast values were 0.6 ± 0.3, 1.3 ± 0.5, 1.0 ± 0.4, and 0.6 ± 0.4, while normalized aCNR values were 68.9 ± 50.9, 128.4 ± 59.2, 74.2 ± 42.1, and 99.4 ± 73.9. DATA CONCLUSION: Volumetric dark blood contrast-enhanced brain MRI is feasible using echo-uT1 RESS. The dark blood effect was improved vs. fid-uT1 RESS, while both uT1 RESS versions provided better tumor-to-brain contrast than MPRAGE. Whereas T1 SPACE provided better tumor aSNR, echo-uT1 RESS provided better Weber contrast, lesion sharpness and a more consistent dark blood effect. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 1.

14.
Mult Scler ; 29(11-12): 1406-1417, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37712486

RESUMO

BACKGROUND: Paramagnetic rim lesions (PRLs) are an imaging biomarker in multiple sclerosis (MS), associated with a more severe disease. OBJECTIVES: To determine quantitative magnetic resonance imaging (MRI) metrics of PRLs, lesions with diffuse susceptibility-weighted imaging (SWI)-hypointense signal (DSHLs) and SWI-isointense lesions (SILs), their surrounding periplaque area (PPA) and the normal-appearing white matter (NAWM). METHODS: In a cross-sectional study, quantitative MRI metrics were measured in people with multiple sclerosis (pwMS) using the multi-dynamic multi-echo (MDME) sequence post-processing software "SyMRI." RESULTS: In 30 pwMS, 59 PRLs, 74 DSHLs, and 107 SILs were identified. Beside longer T1 relaxation times of PRLs compared to DSHLs and SILs (2030.5 (1519-2540) vs 1615.8 (1403.3-1953.5) vs 1199.5 (1089.6-1334.6), both p < 0.001), longer T1 relaxation times were observed in the PRL PPA compared to the SIL PPA and the NAWM but not the DSHL PPA. Patients with secondary progressive multiple sclerosis (SPMS) had longer T1 relaxation times in PRLs compared to patients with late relapsing multiple sclerosis (lRMS) (2394.5 (2030.5-3040) vs 1869.3 (1491.4-2451.3), p = 0.015) and also in the PRL PPA compared to patients with early relapsing multiple sclerosis (eRMS) (982 (927-1093.5) vs 904.3 (793.3-958.5), p = 0.013). CONCLUSION: PRLs are more destructive than SILs, leading to diffuse periplaque white matter (WM) damage. The quantitative MRI-based evaluation of the PRL PPA could be a marker for silent progression in pwMS.


Assuntos
Esclerose Múltipla , Substância Branca , Humanos , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Estudos Transversais , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos
15.
Acta Radiol ; 64(5): 1738-1746, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36380498

RESUMO

BACKGROUND: The liver T1 reduction rate can be used to assess liver function. However, higher doses of gadoxetic acid may shorten the liver T1 value in the hepatobiliary phase and increase the T1 reduction rate in patients with severe liver dysfunction, potentially overestimating liver function. PURPOSE: To verify the relationship between the gadoxetic acid dose and the liver T1 reduction rate and ΔR1 of the liver and spleen, and to clarify whether the ΔR1 of hepatocytes, corrected for the effect of gadoxetic acid dose, could be used as an index of functional liver reserve. MATERIAL AND METHODS: We enrolled 13 patients with normal liver function (NLF); and 18, 8, and 3 patients with Child-Pugh classes A (CPA), B (CPB), and C (CPC) who underwent gadoxetic acid-enhanced magnetic resonance imaging. Phase-sensitive inversion recovery sequence was performed before and at 15 min after injection and T1 maps were calculated. Liver and spleen ΔR1, liver T1 reduction rate, and the liver-to-spleen ΔR1 ratio were calculated. RESULTS: Only the liver-to-spleen ΔR1 ratio showed no correlation with gadoxetic acid dose in any group. The T1 reduction rate was not significantly different between the CPA and CPB + CPC groups. The liver-to-spleen ΔR1 ratio significantly differed between all groups. CONCLUSION: The liver and spleen ΔR1 was dependent on the dose of gadoxetic acid in severe liver dysfunction. The liver-to-spleen ΔR1 ratio improves the delineation of the CPA and CPB + CPC groups.


Assuntos
Hepatopatias , Neoplasias Hepáticas , Humanos , Baço/diagnóstico por imagem , Meios de Contraste , Estudos Retrospectivos , Fígado/diagnóstico por imagem , Gadolínio DTPA , Imageamento por Ressonância Magnética/métodos
16.
Magn Reson Med ; 87(1): 33-49, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34374449

RESUMO

PURPOSE: Ultrahigh field MRS has improved characterization of the neurochemical profile. To compare results obtained at 9.4T to those from lower field strengths, it is of interest to quantify the concentrations of metabolites measured. Thus, measuring T1 -relaxation times is necessary to correct for T1 -weighting that occurs in acquisitions for single-voxel spectroscopy and spectroscopic imaging. A macromolecule (MM) simulation model was developed to fit MM contributions to the short TE inversion series used to measure T1 -relaxation times. METHODS: An inversion series with seven time points was acquired with metabolite-cycled STEAM to estimate T1 -relaxation times of metabolites. A short TE was employed in this study to retain signals from metabolites with short T2 -relaxation times and J-couplings. The underlying macromolecule spectrum was corrected by developing a sequence-specific, relaxation-corrected simulated MM model. Quantification of metabolite peaks was performed using internal water referencing and relaxation corrections. RESULTS: T1 -relaxation times for metabolites range from approximately 750 to approximately 2000 ms and approximately 1000 to approximately 2400 ms in gray matter (GM)- and white matter (WM)- rich voxels, respectively. Quantification of metabolites was compared between GM and WM voxels, as well as between results that used a simulated MM spectrum against those that used an experimentally acquired MM spectrum. Metabolite concentrations are reported in mmol/kg quantities. CONCLUSION: T1 -relaxation times are reported for nonsinglet resonances for the first time at 9.4T by use of a MM simulation model to account for contributions from the MM spectrum. In addition to T1 -relaxation times, quantification results of metabolites from GM- and WM-rich voxels are reported.


Assuntos
Encéfalo , Substância Branca , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Química Encefálica , Substância Cinzenta/metabolismo , Humanos , Substâncias Macromoleculares/metabolismo , Substância Branca/metabolismo
17.
NMR Biomed ; 35(1): e4617, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34562038

RESUMO

Excessive manganese is neurotoxic, which means that it can affect the concentrations of metabolite in 1 H MRS. In addition, manganese is paramagnetic and it may influence the relaxation times of the metabolite. The aim of this study is to assess the sensitivity of the metabolite relaxation properties and concentrations to exogenous manganese deposition in the globus pallidus (GP) of rat brain after repeated manganese injection. Proton magnetic resonance spectroscopy (1 H MRS) experiments in vivo and ex vivo were carried out to evaluate the changes in the metabolite concentration and the major metabolite relaxation times, and histological experiments were also performed after repeated manganese administration. Only the T1 value for N-acetylaspartate (NAA) of the GP was significantly reduced after 1 day of manganese injection compared with that of the control group (p < 0.025). The T1 and T2 values for NAA and total creatine (tCr) (p < 0.025), along with the amounts of NAA, tCr, myo-inositol, choline, and glutamate (p < 0.0086) in the GP, were all significantly decreased after 5 days of manganese administration compared with that of the control group. The changes in the concentration and relaxation properties of NAA and tCr in the GP of rat brain indicated that manganese represented paramagnetism and neurotoxicity after repeated administration. Accurate knowledge of relaxation properties and concentrations of NAA and tCr in this study could help appropriate selection of sequence parameters to improve the ability to distinguish the brain regions affected in cases of manganese poisoning.


Assuntos
Globo Pálido/efeitos dos fármacos , Manganês/toxicidade , Espectroscopia de Prótons por Ressonância Magnética/métodos , Animais , Ácido Aspártico/análogos & derivados , Ácido Aspártico/metabolismo , Colina/metabolismo , Creatina/metabolismo , Globo Pálido/metabolismo , Globo Pálido/patologia , Ratos , Ratos Sprague-Dawley
18.
NMR Biomed ; 35(2): e4629, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34636097

RESUMO

Longitudinal (T1 ) relaxation of triglyceride molecules and water is of interest for fat-water separation and fat quantification. A better understanding of T1 relaxation could benefit modeling for applications in fat quantification and relaxation mapping. This work investigated T1 relaxation of spectral resonances of triglyceride molecules and water in liquid fat-water mixtures and its dependence on the fat fraction. Dairy cream and a safflower oil emulsion were used. These were diluted with distilled water to produce a variety of fat mass fractions (4.4% to 35% in dairy cream and 6.3% to 52.3% in safflower oil emulsion). T1 was measured at room temperature at 3 T using an inversion recovery STimulated Echo Acquisition Mode (STEAM) MR spectroscopy method with a series of inversion times. T1 variations as a function of fat fraction were investigated for various resonances. A two-component model was developed to describe the relaxation in a fat-water mixture as a function of the fat fraction. The T1 of water and of all fat resonances studied in this work decreased as the fat fraction increased. The relative variation in T1 was different for each fat resonance. The T1 of the methylene resonance showed the least variation as a function of the fat fraction. The proposed two-component model closely fits the observed T1 variations. In conclusion, this work clarifies how the T1 of major and minor fat resonances and of the water resonance varies as a function of the fat fraction in fat-water mixtures. Knowledge of these variations could serve modeling, analysis of MRI measurements in fat-water mixtures, and phantom preparation.


Assuntos
Espectroscopia de Ressonância Magnética/métodos , Triglicerídeos/química , Água/química , Emulsões/química , Humanos , Óleo de Girassol/química
19.
J Magn Reson Imaging ; 55(2): 530-540, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34219305

RESUMO

BACKGROUND: Biliary phosphatidylcholine (PtdC) concentration plays a role in the pathogenesis of bile duct diseases. In vivo phosphorus-31 magnetic resonance spectroscopy (31 P-MRS) at 7 T offers the possibility to assess this concentration noninvasively with high spectral resolution and signal intensity. PURPOSE: Comparison of PtdC levels of cholangiopathic patient groups to a control group using a measured T1 relaxation time of PtdC in healthy subjects. STUDY TYPE: Case control. SUBJECTS: Two patient groups with primary sclerosing cholangitis (PSC, 2f/3 m; age: 43 ± 7 years) and primary biliary cholangitis (PBC, 4f/2 m; age: 57 ± 6 years), and a healthy control group (CON, 2f/3 m; age: 38 ± 7 years). Ten healthy subjects for the assessment of the T1 relaxation time of PtdC. FIELD STRENGTH/SEQUENCE: A 3D phase-encoded pulse-acquire 31 P-MRSI sequence for PtdC quantification and a 1D image-selected in vivo 31 P spectroscopy for T1 estimation at 7 T, and a T2-weighted half-Fourier single-shot turbo spin echo MRI sequence for volumetry at 3 T. ASSESSMENT: Calculation of gallbladder volumes and PtdC concentration in groups using hepatic gamma-adenosine triphosphate signal as an internal reference and correction for insufficient relaxation of PtdC with a T1 value assessed in healthy subjects. STATISTICAL TESTS: Group comparison of PtdC content and gallbladder volumes of the PSC/PBC and CON group using Student's t-tests with a significance level of 5%. RESULTS: PtdC T1 value of 357 ± 85 msec in the gallbladder. Significant lower PtdC content for the PSC group, and for the female subgroup of the PBC group compared to the CON group (PSC/CON: 5.74 ± 0.73 mM vs. 9.64 ± 0.97 mM, PBC(f)/CON: 5.77 ± 1.44 mM vs. 9.64 ± 0.97 mM). Significant higher gallbladder volumes of the patient groups compared to the CON group (PSC/CON: 66.3 ± 15.8 mL vs. 20.9 ± 2.2 mL, PBC/CON: 49.8 ± 18.2 mL vs. 20.9 ± 2.2 mL). DATA CONCLUSION: This study demonstrated the application of a 31 P-MRSI protocol for the quantification of PtdC in the human gallbladder at 7 T. Observed differences in PtdC concentration suggest that this metabolite could serve as a biomarker for specific hepatobiliary disorders. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 3.


Assuntos
Colangite Esclerosante , Vesícula Biliar , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Pessoa de Meia-Idade , Fosfatidilcolinas , Fósforo , Projetos Piloto
20.
Mult Scler ; 28(3): 418-428, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34132126

RESUMO

BACKGROUND: Advanced magnetic resonance imaging (MRI) methods can provide more specific information about various microstructural tissue changes in multiple sclerosis (MS) brain. Quantitative measurement of T1 and T2 relaxation, and diffusion basis spectrum imaging (DBSI) yield metrics related to the pathology of neuroinflammation and neurodegeneration that occurs across the spectrum of MS. OBJECTIVE: To use relaxation and DBSI MRI metrics to describe measures of neuroinflammation, myelin and axons in different MS subtypes. METHODS: 103 participants (20 clinically isolated syndrome (CIS), 33 relapsing-remitting MS (RRMS), 30 secondary progressive MS and 20 primary progressive MS) underwent quantitative T1, T2, DBSI and conventional 3T MRI. Whole brain, normal-appearing white matter, lesion and corpus callosum MRI metrics were compared across MS subtypes. RESULTS: A gradation of MRI metric values was seen from CIS to RRMS to progressive MS. RRMS demonstrated large oedema-related differences, while progressive MS had the most extensive abnormalities in myelin and axonal measures. CONCLUSION: Relaxation and DBSI-derived MRI measures show differences between MS subtypes related to the severity and composition of underlying tissue damage. RRMS showed oedema, demyelination and axonal loss compared with CIS. Progressive MS had even more evidence of increased oedema, demyelination and axonal loss compared with CIS and RRMS.


Assuntos
Esclerose Múltipla Crônica Progressiva , Esclerose Múltipla Recidivante-Remitente , Esclerose Múltipla , Substância Branca , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Esclerose Múltipla Crônica Progressiva/diagnóstico por imagem , Esclerose Múltipla Crônica Progressiva/patologia , Esclerose Múltipla Recidivante-Remitente/diagnóstico por imagem , Esclerose Múltipla Recidivante-Remitente/patologia , Doenças Neuroinflamatórias , Substância Branca/diagnóstico por imagem , Substância Branca/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA