Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Acta Biomater ; 169: 107-117, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37579911

RESUMO

The ascending thoracic aortic aneurysm (ATAA) is a permanent dilatation of the vessel with a high risk of adverse events, and shows heterogeneous properties. To investigate regional differences in the biomechanical properties of ATAAs, tissue samples were collected from 10 patients with tricuspid aortic valve phenotype and specimens from minor, anterior, major, and posterior regions were subjected to multi-ratio planar biaxial extension tests and second-harmonic generation (SHG) imaging. Using the data, parameters of a microstructure-motivated constitutive model were obtained considering fiber dispersion. SHG imaging showed disruptions in the organization of the layers. Structural and material parameters did not differ significantly between regions. The non-symmetric fiber dispersion model proposed by Holzapfel et al. [25] was used to fit the data. The mean angle of collagen fibers was negatively correlated between minor and anterior regions, and the parameter associated with collagen fiber stiffness was positively correlated between minor and major regions. Furthermore, correlations were found between the stiffness of the ground matrix and the mean fiber angle, and between the parameter associated with the collagen fiber stiffness and the out-of-plane dispersion parameter in the posterior and minor regions, respectively. The experimental data collected in this study contribute to the biomechanical data available in the literature on human ATAAs. Region-specific parameters for the constitutive models are fundamental to improve the current risk stratification strategies, which are mainly based on aortic size. Such investigations can facilitate the development of more advanced finite element models capable of capturing the regional heterogeneity of pathological tissues. STATEMENT OF SIGNIFICANCE: Tissue samples of human ascending thoracic aortic aneurysms (ATAA) were collected. Samples from four regions underwent multi-ratio planar biaxial extension tests and second-harmonic generation imaging. Region-specific parameters of a microstructure-motivated model considering fiber dispersion were obtained. Structural and material parameters did not differ significantly between regions, however, the mean fiber angle was negatively correlated between minor and anterior regions, and the parameter associated with collagen fiber stiffness was positively correlated between minor and major regions. Furthermore, correlations were found between the stiffness of the ground matrix and the mean fiber angle, and between the parameter associated with the collagen fiber stiffness and the out-of-plane dispersion parameter in the posterior and minor regions, respectively. This study provides a unique set of mechanical and structural data, supporting the microstructural influence on the tissue response. It may facilitate the development of better finite element models capable of capturing the regional tissue heterogeneity.


Assuntos
Aneurisma da Aorta Ascendente , Aneurisma da Aorta Torácica , Humanos , Aneurisma da Aorta Torácica/patologia , Aorta , Matriz Extracelular/patologia , Colágeno , Fenômenos Biomecânicos , Estresse Mecânico
2.
J R Soc Interface ; 16(155): 20190179, 2019 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-31238834

RESUMO

In computational aortic biomechanics, aortic and arterial tissue are typically modelled as a homogeneous layer, making abstraction not only of the layered structure of intima, media and adventitia but also of the microstructure that exists within these layers. Here, we present a novel method to visualize the microstructure of the tunica media along the entire circumference of the vessel. To that end, we developed a pressure-inflation device that is compatible with synchrotron-based phase-contrast imaging. Using freshly excised left common carotid arteries from n = 12 mice, we visualized how the lamellae and interlamellar layers inflate as the luminal pressure is increased from 0 to 120 mm Hg in quasi-static steps. A graph-based segmentation algorithm subsequently allowed us to automatically segment each of the three lamellae, resulting in a three-dimensional geometry that represents lamellae, interlamellar layers and adventitia at nine different pressure levels. Our results demonstrate that the three elastic lamellae unfold and stretch simultaneously as luminal pressure is increased. In the long term, we believe that the results presented in this work can be a first step towards a better understanding of the mechanics of the arterial microstructure.


Assuntos
Pressão Sanguínea/fisiologia , Artéria Carótida Primitiva , Modelos Cardiovasculares , Síncrotrons , Rigidez Vascular/fisiologia , Animais , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Primitiva/fisiologia , Masculino , Camundongos , Camundongos Knockout para ApoE
3.
Acta Biomater ; 99: 1-17, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31419563

RESUMO

Aortic dissections and aortic aneurysms are fatal events characterized by structural changes to the aortic wall. The maximum diameter criterion, typically used for aneurysm rupture risk estimations, has been challenged by more sophisticated biomechanically motivated models in the past. Although these models are very helpful for the clinicians in decision-making, they do not attempt to capture material failure. Following a short overview of the microstructure of the aorta, we analyze the failure mechanisms involved in the dissection and rupture by considering also traumatic rupture. We continue with a literature review of experimental studies relevant to quantify tissue strength. More specifically, we summarize more extensively uniaxial tensile, bulge inflation and peeling tests, and we also specify trouser, direct tension and in-plane shear tests. Finally we analyze biomechanically motivated models to predict rupture risk. Based on the findings of the reviewed studies and the rather large variations in tissue strength, we propose that an appropriate material failure criterion for aortic tissues should also reflect the microstructure in order to be effective. STATEMENT OF SIGNIFICANCE: Aortic dissections and aortic aneurysms are fatal events characterized by structural changes to the aortic wall. Despite the advances in medical, biomedical and biomechanical research, the mortality rates of aneurysms and dissections remain high. The present review article summarizes experimental studies that quantify the aortic wall strength and it discusses biomechanically motivated models to predict rupture risk. We identified contradictory observations and a large variation within and between data sets, which may be due to biological variations, different sample sizes, differences in experimental protocols, etc. Based on the findings of the reviewed literature and the rather large variations in tissue strength, it is proposed that an appropriate criterion for aortic failure should also reflect the microstructure.


Assuntos
Dissecção Aórtica/fisiopatologia , Ruptura Aórtica/fisiopatologia , Aorta Abdominal/fisiopatologia , Fenômenos Biomecânicos , Colágeno/metabolismo , Simulação por Computador , Progressão da Doença , Elasticidade , Humanos , Modelos Cardiovasculares , Medição de Risco , Estresse Mecânico , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA