Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.350
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Osteoporos Int ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38767743

RESUMO

This study investigates the effects of antiresorptive drugs and risk factors for medication-related osteonecrosis of the jaws in osteoporotic patients undergoing tooth extraction. Among the findings, antiresorptive-treated patients had thicker lamina dura and longer healing times. Additionally, corticosteroid intake and multi-rooted teeth carried a higher osteonecrosis risk. Bone sequestrum indicated osteonecrosis. PURPOSE: To describe the effects of antiresorptive drugs (ARD) in the maxilla and mandible and risk factors for medication-related osteonecrosis of the jaws (MRONJ) in osteoporotic patients undergoing tooth extractions using clinical data and cone beam computed tomography (CBCT). METHODS: This retrospective cohort study collected clinical and CBCT data from 176 patients. The study group (n = 78; 224 extractions) received ARD treatment, underwent tooth extraction, and had a pre-operative CBCT. Additionally, age-, sex-, and tooth-matched controls were selected (n = 98; 227 extractions). Radiographic examinations were performed independently by three calibrated examiners. Statistical analysis included Chi-square, Fisher's exact, Mann-Whitney U, and t-tests to contrast clinical and radiographic data between study and control, MRONJ + and MRONJ - , and bisphosphonate and denosumab patients/sites. Significance was set at p ≤ 0.05. RESULTS: From the study group, 4 patients (5%) and 5 sites (2%) developed MRONJ after tooth extraction. ARD-treated patients exhibited significantly more thickening of the lamina dura and a longer average mucosal healing time (4.4 weeks) than controls (2.6 weeks). In the study group, MRONJ risk significantly increased with corticosteroid intake and in multi-rooted teeth. No significant differences between bisphosphonates and denosumab use were seen in the tomographic features (p > 0.05). Lastly, bone sequestrum was exclusively observed in osteoporotic patients, who exhibited post-operative exposed bone or histological evidence of osteonecrosis. CONCLUSION: Osteoporotic patients under ARD may exhibit thickening of the lamina dura and prolonged post-operative healing. Among these patients, multi-rooted teeth are at higher risk for MRONJ than single-rooted teeth. Sequester formation is a radiographic indicator of osteonecrosis.

2.
Respir Res ; 25(1): 65, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38317222

RESUMO

BACKGROUND: Endobronchial ultrasound (EBUS) and cone-beam computed tomography-derived augmented fluoroscopy (CBCT-AF) are utilized for the diagnosis of peripheral pulmonary lesions (PPLs). Combining them with transbronchial cryobiopsy (TBC) can provide sufficient tissue for genetic analysis. However, cryoprobes of different sizes have varying degrees of flexibility, which can affect their ability to access the target bronchus and potentially impact the accuracy. The aim of this study was to compare the diagnostic efficacy of cryoprobes of varying sizes in CBCT-AF and EBUS for the diagnosis of PPLs. METHODS: Patients who underwent endobronchial ultrasound-guided transbronchial biopsy (EBUS-TBB) and TBC combined with CBCT-AF for PPLs diagnosis between January 2021 and May 2022 were included. Propensity score matching and competing-risks regression were utilized for data analysis. Primary outcome was the diagnostic accuracy of TBC. RESULTS: A total of 284 patients underwent TBC, with 172 using a 1.7-mm cryoprobe (1.7 group) and 112 using a 1.1-mm cryoprobe (1.1 group). Finally, we included 99 paired patients following propensity score matching. The diagnostic accuracy of TBC was higher in the 1.1 group (80.8% vs. 69.7%, P = 0.050), with a similar rate of complications. Subgroup analysis also revealed that the 1.1 group had better accuracy when PPLs were located in the upper lobe (85.2% vs. 66.1%, P = 0.020), when PPLs were smaller than 20 mm (78.8% vs. 48.8%, P = 0.008), and when intra-procedural CBCT was needed to be used (79.5% vs. 42.3%, P = 0.001). TBC obtained larger specimens than TBB in both groups. There is still a trend of larger sample size obtained in the 1.7 group, but there is no statistically different between our two study groups (40.8 mm2 vs. 22.0 mm2, P = 0.283). CONCLUSIONS: The combination of TBC with CBCT-AF and EBUS is effective in diagnosing PPLs, and a thin cryoprobe is preferred when the PPLs located in difficult areas.


Assuntos
Pneumopatias , Neoplasias Pulmonares , Humanos , Pneumopatias/diagnóstico , Broncoscopia , Biópsia Guiada por Imagem , Neoplasias Pulmonares/patologia , Biópsia , Tomografia Computadorizada de Feixe Cônico , Fluoroscopia , Estudos Retrospectivos
3.
Catheter Cardiovasc Interv ; 103(1): 230-233, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37668044

RESUMO

Absence of periprocedural visualization of three-dimensional (3D) left heart anatomy and its surrounding structures in fluoroscopy may reduce the rate of successful transcatheter mitral valve repair. We proposed a multimodal imaging strategy based on 3D computed tomography (CT) angiography and 3D cone beam CT fusion images, which enabled real-time visual inspection of 3D cardiac structures on fluoroscopy, to optimize transcatheter mitral intervention. This new image fusion technology, together with standard transesophageal echocardiography guidance, improved the efficiency and safety of the procedure, and could be considered as a new workflow for transcatheter mitral valve intervention.


Assuntos
Insuficiência da Valva Mitral , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Resultado do Tratamento , Tomografia Computadorizada por Raios X , Angiografia , Fluoroscopia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos
4.
Eur Radiol ; 34(4): 2576-2589, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37782338

RESUMO

OBJECTIVES: To develop a radiomics model in contrast-enhanced cone-beam breast CT (CE-CBBCT) for preoperative prediction of axillary lymph node (ALN) status and metastatic burden of breast cancer. METHODS: Two hundred and seventy-four patients who underwent CE-CBBCT examination with two scanners between 2012 and 2021 from two institutions were enrolled. The primary tumor was annotated in each patient image, from which 1781 radiomics features were extracted with PyRadiomics. After feature selection, support vector machine models were developed to predict ALN status and metastatic burden. To avoid overfitting on a specific patient subset, 100 randomly stratified splits were made to assign the patients to either training/fine-tuning or test set. Area under the receiver operating characteristic curve (AUC) of these radiomics models was compared to those obtained when training the models only with clinical features and combined clinical-radiomics descriptors. Ground truth was established by histopathology. RESULTS: One hundred and eighteen patients had ALN metastasis (N + (≥ 1)). Of these, 74 had low burden (N + (1~2)) and 44 high burden (N + (≥ 3)). The remaining 156 patients had none (N0). AUC values across the 100 test repeats in predicting ALN status (N0/N + (≥ 1)) were 0.75 ± 0.05 (0.67~0.93, radiomics model), 0.68 ± 0.07 (0.53~0.85, clinical model), and 0.74 ± 0.05 (0.67~0.88, combined model). For metastatic burden prediction (N + (1~2)/N + (≥ 3)), AUC values were 0.65 ± 0.10 (0.50~0.88, radiomics model), 0.55 ± 0.10 (0.40~0.80, clinical model), and 0.64 ± 0.09 (0.50~0.90, combined model), with all the ranges spanning 0.5. In both cases, the radiomics model was significantly better than the clinical model (both p < 0.01) and comparable with the combined model (p = 0.56 and 0.64). CONCLUSIONS: Radiomics features of primary tumors could have potential in predicting ALN metastasis in CE-CBBCT imaging. CLINICAL RELEVANCE STATEMENT: The findings support potential clinical use of radiomics for predicting axillary lymph node metastasis in breast cancer patients and addressing the limited axilla coverage of cone-beam breast CT. KEY POINTS: • Contrast-enhanced cone-beam breast CT-based radiomics could have potential to predict N0 vs. N + (≥ 1) and, to a limited extent, N + (1~2) vs. N + (≥ 3) from primary tumor, and this could help address the limited axilla coverage, pending future verifications on larger cohorts. • The average AUC of radiomics and combined models was significantly higher than that of clinical models but showed no significant difference between themselves. • Radiomics features descriptive of tumor texture were found informative on axillary lymph node status, highlighting a higher heterogeneity for tumor with positive axillary lymph node.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/patologia , Metástase Linfática/patologia , Axila/patologia , Radiômica , Estudos Retrospectivos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Tomografia Computadorizada de Feixe Cônico
5.
Int J Legal Med ; 138(3): 1117-1137, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38010514

RESUMO

INTRODUCTION: The anterior nasal spine is a pointed, midline projection of the maxilla. This bony structure dictates the overlying soft tissues providing the phenotypic features of the nose and upper lip and determines the differences in the mid-face morphology. Little data is available on the metric features of the Anterior nasal spine (ANS). This study aimed to perform metric evaluations of the ANS of white and black South African males and females to ascertain if morphological variations exist and if the differences are viable for the use in sex and population identification. MATERIALS AND METHODS: The sample included 100 CBCT images for each population and sex group. Linear and angular measurements of the ANS were recorded in both the sagittal and axial planes. RESULTS: Classification decision trees (pruned) were fitted to ascertain the relationship between population group, sex and the ANS measurements including and excluding age. For population group, all the ANS measurements were statistically significant for females but in males, all the ANS measurements were significant when performed individually. However, when fitted to the classification tree, Sagittal 2 did not show any statistical significance. When considering sex, only 2 of the ANS measurements (Sagittal 2 and Axial 1) were found to be significant. The results did not differ significantly when comparing the decision trees including and excluding age. CONCLUSIONS: White South African individuals presented with a longer ANS that produced a more acute angle whereas black South African individuals presented with a shorter ANS and a more obtuse angle. Additionally, males presented with a longer ANS compared to females. ANS measurements were found to be more relevant for population discernment than for sex.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Grupos Populacionais , Masculino , Feminino , Humanos , África do Sul , Tomografia Computadorizada de Feixe Cônico/métodos , Maxila/anatomia & histologia , Nariz
6.
Int J Legal Med ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38856752

RESUMO

Investigation of the biological sex of human remains is a crucial aspect of physical anthropology. However, due to varying states of skeletal preservation, multiple approaches and structures of interest need to be explored. This research aims to investigate the potential use of distances between bifrontal breadth (FMB), infraorbital foramina distance (IOD), nasal breadth (NLB), inter-canine width (ICD), and distance between mental foramina (MFD) for combined sex prediction through traditional statistical methods and through open-access machine-learning tools. Ethical approval was obtained from the ethics committee, and out of 100 cone beam computed tomography (CBCT) scans, 54 individuals were selected with all the points visible. Ten extra exams were chosen to test the predictors developed from the learning sample. Descriptive analysis of measurements, standard deviation, and standard error were obtained. T-student and Mann-Whitney tests were utilized to assess the sex differences within the variables. A logistic regression equation was developed and tested for the investigation of the biological sex as well as decision trees, random forest, and artificial neural networks machine-learning models. The results indicate a strong correlation between the measurements and the sex of individuals. When combined, the measurements were able to predict sex using a regression formula or machine learning based models which can be exported and added to software or webpages. Considering the methods, the estimations showed an accuracy rate superior to 80% for males and 82% for females. All skulls in the test sample were accurately predicted by both statistical and machine-learning models. This exploratory study successfully established a correlation between facial measurements and the sex of individuals, validating the prediction potential of machine learning, augmenting the investigative tools available to experts with a high differentiation potential.

7.
Periodontol 2000 ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38951952

RESUMO

While peri-implant mucositis relies solely on clinical parameters, radiological assessment becomes indispensable for diagnosing peri-implantitis. Intraoral radiography, with its simplicity of application, low radiation exposure, and adequate representation of peri-implant structures, stands out as the standard of care for both immediate and follow-up assessments. Standardization by custom-made radiologic splints allows for excellent comparability with previous images and allows for the determination of even small changes in contour and density of the peri-implant bone. Furthermore, other radiographic modalities like panoramic radiography and cone beam computed tomography (CBCT) may provide useful features for specific patients and clinical cases while also showing innate limitations. Beyond the assessment of the marginal peri-implant bone level as the crucial parameter of clinical relevance, radiologic assessment may reveal various other findings related to the prosthetic restoration itself, the precision of its fit to the implant, and the peri-implant soft and hard tissues. Since such findings can be crucial for the assessment of peri-implant health and the implants' prognosis, a systematic diagnostic evaluation pathway for a thorough assessment is recommended to extract all relevant information from radiologic imaging. This article also provides an overview of the clinical and chronological indications for different imaging modalities in peri-implant issues.

8.
Periodontol 2000 ; 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38546140

RESUMO

The components and dimensions of the periodontal and peri-implant phenotype have a high relevance in contemporary dental research and should be taken into consideration in the decision-making process in the management of a variety of clinical scenarios to optimize the outcomes of therapy. Various assessment methods for quantifying and classifying the phenotypical dimensions have emerged and developed in recent decades. Nevertheless, the use of cone-beam computed tomography (CBCT) scans remains the most commonly used approach worldwide. However, the accuracy to adequately imaging and measuring the dimensions of the hard and soft tissue components around teeth may represent a significant challenge in different clinical scenarios due to factors such as the age of the patient and motion during the scan, presence of metallic artifacts causing streaks and gray-value distortion, overlapping of soft tissue structures, machine performance, file processing, and small voxel size among others. These factors pose a particular challenge when tiny structures are under investigation, for example, the buccal/lingual bony or soft tissue layer of lower/upper incisors. Therefore, this review addresses the underlying technical information of the use of CBCT scans, and suggests some recommendations on the utilization of this method of assessment to optimally use it despite its' system-inherent limitations.

9.
J Clin Periodontol ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38828551

RESUMO

AIM: To evaluate the radiographic outcomes of lateral sinus floor elevation with simultaneous implant placement at sites without sinus membrane perforation (SMP) and sites with SMP managed with a resorbable membrane. MATERIALS AND METHODS: One hundred and thirty-nine patients and 170 implants (56 perforation, 114 non-perforation) were included. Cone-beam computed tomography (CBCT) images were taken before surgery (T0), immediately after surgery (T1) and 6 months after surgery (T2). Post-operative augmentation parameters, including endo-sinus bone gain (ESBG) along the implant axis, mean new bone height (NBH) surrounding the implant and augmentation volume (AV), were measured at T1 and T2. RESULTS: At T1, there were no significant differences in ESBG, NBH and AV between the two groups. At T2, although ESBG did not significantly differ between the two groups, NBH (8.50 ± 1.99 mm vs. 9.99 ± 2.52 mm, p = .039) and AV (519.37 ± 258.38 mm3 vs. 700.99 ± 346.53 mm3, p < .001) were significantly lower in the perforation group. The shrinkage of graft material from T1 to T2, including ΔESBG (p = .002), ΔNBH (p < .001) and ΔAV (p < .001), was higher in the perforation group. CONCLUSIONS: SMP during LSFE with simultaneous implant placement is associated with greater resorption of the grafted area at a 6-month follow-up.

10.
Respirology ; 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806394

RESUMO

BACKGROUND AND OBJECTIVE: Robotic-assisted bronchoscopy (RAB) is an emerging modality to sample pulmonary lesions. Cone-beam computed tomography (CBCT) can be incorporated into RAB. We investigated the magnitude and predictors of patient and staff radiation exposure during mobile CBCT-guided shape-sensing RAB. METHODS: Patient radiation dose was estimated by cumulative dose area product (cDAP) and cumulative reference air kerma (cRAK). Staff equivalent dose was calculated based on isokerma maps and a phantom simulation. Patient, lesion and procedure-related factors associated with higher radiation doses were identified by logistic regression models. RESULTS: A total of 198 RAB cases were included in the analysis. The median patient cDAP and cRAK were 10.86 Gy cm2 (IQR: 4.62-20.84) and 76.20 mGy (IQR: 38.96-148.38), respectively. Among staff members, the bronchoscopist was exposed to the highest median equivalent dose of 1.48 µSv (IQR: 0.85-2.69). Both patient and staff radiation doses increased with the number of CBCT spins and targeted lesions (p < 0.001 for all comparisons). Patient obesity, negative bronchus sign, lesion size <2.0 cm and inadequate sampling by on-site evaluation were associated with a higher patient dose, while patient obesity and inadequate sampling by on-site evaluation were associated with a higher bronchoscopist equivalent dose. CONCLUSION: The magnitude of patient and staff radiation exposure during CBCT-RAB is aligned with safety thresholds recommended by regulatory authorities. Factors associated with a higher radiation exposure during CBCT-RAB can be identified pre-operatively and solicit procedural optimization by reinforcing radiation protective measures. Future studies are needed to confirm these findings across multiple institutions and practices.

11.
Respirology ; 29(4): 324-332, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38016646

RESUMO

BACKGROUND AND OBJECTIVE: Shape-sensing robotic-assisted bronchoscopy (ssRAB) has expanded as an important diagnostic tool for peripheral pulmonary nodules (PPNs), with diagnostic yields ranging from 60% to 88%. However, sampling and diagnosing PPN less than 2 cm in size has historically been challenging. Mobile cone-beam computed tomography (mCBCT) has been recently integrated into ssRAB to improve diagnostic accuracy, but its added value remains uncertain. We aim to describe the role of mCBCT and determine if it provides any diagnostic advantage. METHODS: A multicentre, retrospective study on the use of ssRAB and mCBCT in two tertiary care institutions: Mayo Clinic Florida and Massachusetts General Hospital. The primary outcome was diagnostic yield and sensitivity for malignancy of ssRAB complemented with mCBCT, compared to ssRAB with the standard 2D fluoroscopy. RESULTS: A total of 192 nodules were biopsied from 173 patients. mCBCT was used in 117 (60.9%) nodules. The overall diagnostic yield was 85.4%. Diagnostic yield between subgroups with and without mCBCT was 83.8% and 88% (p = 0.417), respectively. The mCBCT group had fewer solid nodules (65.8% vs. 81.3%, p = 0.020) and a higher number of ground-glass nodules (10.3% vs. 1.3%, p = 0.016). CONCLUSION: Overall, diagnostic yield between subgroups with and without mCBCT was similar. The complementary use of mCBCT to ssRAB allows proceduralists to target more complex and subsolid PPNs with a diagnostic yield comparable to simple solid PPNs while maintaining an excellent safety profile.


Assuntos
Neoplasias Pulmonares , Neoplasias , Procedimentos Cirúrgicos Robóticos , Humanos , Broncoscopia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Retrospectivos , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia
12.
Clin Oral Implants Res ; 35(5): 573-584, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38467593

RESUMO

OBJECTIVES: To introduce a modified guided bone regeneration (GBR) technique using intact periosteum and deproteinized bovine bone mineral (DBBM) for peri-implant augmentation and compare the clinical outcomes with those of conventional GBR. MATERIALS AND METHODS: Patients who received peri-implant augmentation in posterior sites between 2015 and 2021 were reviewed in this study. Group A was treated with a modified GBR technique, and Group B was treated with conventional GBR. For group comparison, propensity score matching was performed with a sensitivity analysis. The implant survival rate, dimensional changes in hard tissue, marginal bone loss (MBL), and peri-implant parameters were evaluated. RESULTS: In total, 114 implants from 98 patients were included. The implant survival rates were 95.74% in Group A and 95.00% in Group B during the follow-up period. At 6 months, the median horizontal thickness was recorded at 0.87 mm (IQ1-IQ3 = 0.00-1.75 mm) in Group A, exhibiting a relatively lower value compared to the corresponding measurement of 0.98 mm (IQ1-IQ3 = 0.00-1.89 mm) in Group B (p = .937). Vertical height displayed no statistically significant intergroup difference between the two groups (p = .758). The mean follow-up period was 25.83 ± 12.93 months after loading in Group A and 27.47 ± 21.29 months in Group B (p = .761). MBL and peri-implant parameters were comparable between the two groups. CONCLUSIONS: Within the limitations of this study, the modified GBR technique using intact periosteum and DBBM grafting might be a viable alternative to correct bone defects around implants in molar and premolar sites.


Assuntos
Regeneração Óssea , Regeneração Tecidual Guiada Periodontal , Humanos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Seguimentos , Adulto , Regeneração Tecidual Guiada Periodontal/métodos , Implantação Dentária Endóssea/métodos , Periósteo/cirurgia , Aumento do Rebordo Alveolar/métodos , Perda do Osso Alveolar/cirurgia , Resultado do Tratamento , Idoso , Implantes Dentários
13.
Artigo em Inglês | MEDLINE | ID: mdl-38970301

RESUMO

AIM: To evaluate the performance of low-dose cone beam computed tomography (CBCT) protocols with regard to linear bone measurements in the posterior mandible for implant planning compared with higher dose protocols. MATERIALS AND METHODS: Forty-two edentulous posterior sites in human cadaveric mandibles were imaged in three CBCT scanners using three or four protocols with varying exposure parameters to achieve lower dose. Co-registration was performed to generate sagittal and cross-sectional image sections representative of the implant site. Three observers measured bone height, from the alveolar crest to the mandibular canal, and width, three mm from the top of the alveolar crest. Intra- and interobserver reproducibility were assessed for the cases rated as nonmeasurable as well as for completed measurements. The measurements were analyzed using paired t-tests for differences among the CBCT protocols and the frequency distribution of nonmeasurable cases with a Pearson Chi-square test. RESULTS: Reproducibility for registering nonmeasurable cases varied among observers; however, no consistent significant differences were found in the frequency distribution of these cases among observers, units, and protocols. Intraclass correlation coefficients (ICC) were >0.9 for all measurements of bone height and width. Mean differences of <0.5 mm were found regardless of protocol; however, one observer did in some cases produce larger differences. CONCLUSION: Linear bone measurements did not differ significantly and could be performed with excellent reliability, using low-dose CBCT protocols compared with standard and high-resolution ones. Varying approaches for rating nonmeasurable cases were found, indicating differences in diagnostic strategies related to implant planning among observers.

14.
Artigo em Inglês | MEDLINE | ID: mdl-38845570

RESUMO

OBJECTIVES: To investigate the accuracy of artificial intelligence (AI)-based segmentation of the mandibular canal, compared to the conventional manual tracing, implementing implant planning software. MATERIALS AND METHODS: Localization of the mandibular canals was performed for 104 randomly selected patients. A localization was performed by three experienced clinicians in order to serve as control. Five tracings were performed: One from a clinician with a moderate experience with a manual tracing (I1), followed by the implementation of an automatic refinement (I2), one manual from a dental student (S1), and one from the experienced clinician, followed by an automatic refinement (E). Subsequently, two fully automatic AI-driven segmentations were performed (A1,A2). The accuracy between each method was measured using root mean square error calculation. RESULTS: The discrepancy among the models of the mandibular canals, between the experienced clinicians and each investigated method ranged from 0.21 to 7.65 mm with a mean of 3.5 mm RMS error. The analysis of each separate mandibular canal's section revealed that mean RMS error was higher in the posterior and anterior loop compared to the middle section. Regarding time efficiency, tracing by experienced users required more time compared to AI-driven segmentation. CONCLUSIONS: The experience of the clinician had a significant influence on the accuracy of mandibular canal's localization. An AI-driven segmentation of the mandibular canal constitutes a time-efficient and reliable procedure for pre-operative implant planning. Nevertheless, AI-based segmentation results should always be verified, as a subsequent manual refinement of the initial segmentation may be required to avoid clinical significant errors.

15.
Artigo em Inglês | MEDLINE | ID: mdl-38873850

RESUMO

OBJECTIVES: To analyze the three-dimensional stability and morphologic changes of tent space after the osteotome sinus floor elevation (OSFE) procedures without bone grafts. MATERIALS AND METHODS: Forty-six implants placed using the OSFE technique with simultaneous implant placement without bone grafts were included in this retrospective study. Cone-beam computed tomography (CBCT) scans of the augmented sinuses were obtained pre- and postoperatively up to 48 months of follow-up. The maxillary sinus cavity profiles were outlined using three-dimensional virtual reconstruction and superimposition of CBCT scans. The three-dimensional changes in the tent space were measured. A generalized estimating equation (GEE) was used to explore potential factors. RESULTS: The implant survival rate was 97.8%. The mean volume of remaining tent space immediately after surgery was 96.8 ± 70.5 mm3, shrinking to 31.0 ± 24.9 mm3 after 48 months, while the mean percentage of remaining tent space volume decreased to 29.1 ± 20.7%. The tent space volume and the percentage of residual tent space volume only decreased significantly within 12 months after surgery (p = .008, .013). GEE results indicated positive correlations between the percentage of remaining tent space volume and implant protrusion length (p = .000) and apical height (p = .000), with a negative correlation between the sinus floor area immediately after surgery (p = .002) and the healing time (p = .022). CONCLUSIONS: The volume of the tent space rapidly shrank after OSFE without bone grafts. Several factors might influence the tent space stability. Long-term clinical trials with larger sample sizes are necessary to further validate the results.

16.
Respiration ; 103(1): 32-40, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38056434

RESUMO

INTRODUCTION: Cryobiopsy (CB) using a 1.1-mm cryoprobe under fluoroscopic guidance is feasible and safe for diagnosis of ground glass opacity (GGO) lesions. However, the efficacy of CB combined with cone-beam CT (CBCT) for GGO-predominant pulmonary nodules remains elusive. METHODS: We retrospectively studied patients who underwent CB combined with conventional biopsy under CBCT guidance for GGO-predominant pulmonary nodules with a consolidation-to-tumour ratio <50.0%. RESULTS: A total of 32 patients with GGO-predominant pulmonary nodules were enrolled: 17 pure GGOs and 15 mixed GGOs. The mean lesion diameter was 15.81 ± 5.52 mm and the overall diagnostic yield was 71.9%. Seven lesions were diagnosed by CB alone, which increased the diagnostic outcomes by 21.9%. Diagnostic yields for CB, forceps biopsy (FB), brushing, and guide sheath flushing were 65.6%, 46.9%, 15.6%, and 14.3%, respectively. Univariate analysis revealed that positive computed tomography (CT) bronchus sign (p = 0.035), positive CBCT sign (p < 0.01), and CB-first biopsy sequence (p = 0.036) were significant predictive factors for higher diagnostic yield. Specimens obtained by CB had larger mean sample size (p < 0.01), lower blood cell area (p < 0.01), and fewer crush artefacts (p < 0.01) than specimens from FB. No severe bleeding or other complications occurred. CONCLUSION: CB using a 1.1-mm cryoprobe under CBCT guidance increased diagnostic yield for GGO-predominant pulmonary nodules based on conventional biopsy. Further, it provided larger and nearly intact samples compared with forceps.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Estudos Retrospectivos , Biópsia/métodos , Tomografia Computadorizada de Feixe Cônico , Nódulos Pulmonares Múltiplos/diagnóstico por imagem
17.
BMC Med Imaging ; 24(1): 145, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872126

RESUMO

BACKGROUND: To compare the diagnostic value of 120-kV with conventional 96-kV Cone-Beam CT (CBCT) of the temporal bone after cochlear implant (CI) surgery. METHODS: This retrospective study included CBCT scans after CI surgery between 06/17 and 01/18. CBCT allowed examinations with 96-kV or 120-kV; other parameters were the same. Two radiologists independently evaluated following criteria on 5-point Likert scales: osseous spiral lamina, inner and outer cochlear wall, semi-circular canals, mastoid trabecular structure, overall image quality, metal and motion artefacts, depiction of intracochlear electrode position and visualisation of single electrode contacts. Effective radiation dose was assessed. RESULTS: Seventy-five patients (females, n = 39 [52.0%], mean age, 55.8 ± 16.5 years) were scanned with 96-kV (n = 32, 42.7%) and 120-kV (n = 43, 57.3%) protocols including CI models from three vendors (vendor A n = 7; vendor B n = 43; vendor C n = 25). Overall image quality, depiction of anatomical structures, and electrode position were rated significantly better in 120-kV images compared to 96-kV (all p < = 0.018). Anatomical structures and electrode position were rated significantly better in 120-kV CBCT for CI models from vendor A and C, while 120-kV did not provide improved image quality in CI models from vendor B. Radiation doses were significantly higher for 120-kV scans compared to 96-kV (0.15 vs. 0.08 mSv, p < 0.001). CONCLUSIONS: 120-kV and 96-kV CBCT provide good diagnostic images for the postoperative CI evaluation. While 120-kV showed improved depiction of temporal bone and CI electrode position compared to 96-kV in most CI models, the 120-kV protocol should be chosen wisely due to a substantially higher radiation exposure.


Assuntos
Implantes Cocleares , Tomografia Computadorizada de Feixe Cônico , Doses de Radiação , Osso Temporal , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Masculino , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Osso Temporal/diagnóstico por imagem , Idoso , Adulto , Implante Coclear/métodos
18.
Sleep Breath ; 28(1): 193-201, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37466758

RESUMO

PURPOSE: To compare the anatomical balance and shape of the upper airway in the supine position between adults with positional obstructive sleep apnea (POSA) and adults with non-positional OSA (NPOSA). METHODS: Adults diagnosed with OSA (apnea-hypopnea index (AHI) > 10 events/h) were assessed for eligibility. POSA was defined as the supine AHI more than twice the AHI in non-supine positions; otherwise, patients were classified as NPOSA. Cone beam computed tomography (CBCT) imaging was performed for every participant while awake in the supine position. The anatomical balance was calculated as the ratio of the tongue size to the maxillomandibular enclosure size. The upper airway shape was calculated as the ratio of the anteroposterior dimension to the lateral dimension at the location of the minimal cross-sectional area of the upper airway (CSAmin-shape). RESULTS: Of 47 participants (28 males, median age [interquartile range] 56 [46 to 63] years, median AHI 27.8 [15.0 to 33.8]), 34 participants were classified as having POSA (72%). The POSA group tended to have a higher proportion of males and a lower AHI than the NPOSA group (P = 0.07 and 0.07, respectively). After controlling for both sex and AHI, the anatomical balance and CSAmin-shape were not significantly different between both groups (P = 0.18 and 0.73, respectively). CONCLUSION: Adults with POSA and adults with NPOSA have similar anatomical balance and shape of their upper airway in the supine position. TRIAL REGISTRATION: This study was registered with the Australian New Zealand Clinical Trials Registry (ANZCTR Trial ACTRN12611000409976).


Assuntos
Apneia Obstrutiva do Sono , Masculino , Adulto , Humanos , Pessoa de Meia-Idade , Decúbito Dorsal , Polissonografia , Austrália , Tomografia Computadorizada de Feixe Cônico
19.
Orthod Craniofac Res ; 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38577813

RESUMO

OBJECTIVES: The primary objective of this study was to assess the validity of the KPG index in predicting the difficulty of treatment involving impacted maxillary canines. The secondary objective was to assess the reliability and reproducibility of the index. MATERIALS AND METHODS: A retrospective study was conducted on 96 maxillary impacted canines (MIC) in 60 patients aged 13-35 years. Cone-beam computed tomography (CBCT) scans were used to predict the treatment difficulty of MIC using the KPG index. Patient case files were assessed for the actual difficulty encountered in treating MIC. Cohen's kappa correlation coefficient was used for intra-observer reliability and Kendell's W test was used for inter-observer reliability. Spearman's correlation coefficient test was used to assess the correlation between predicted and actual treatment. RESULTS: Easy and moderately difficult cases exhibited a moderate correlation between actual and predicted treatment outcomes, whereas difficult cases displayed a weak correlation. The perfect correlation was observed exclusively in extremely difficult cases. The intra-observer reliability for assessing CBCT scans using the KPG guide was found to be 0.88, and the inter-rater reliability was 0.94. CONCLUSION: The KPG index displayed 87%, 71%, 50% and 100% validity in easy, moderately difficult, difficult, and extremely difficult cases, respectively. This index showed good reliability and reproducibility. However, it is imperative to consider a multitude of other factors, including the patient's age, presence of associated root resorption in adjacent teeth, and duration of treatment, to make an informed decision between surgical exposure and extraction.

20.
Orthod Craniofac Res ; 27(3): 421-428, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38124269

RESUMO

OBJECTIVE(S): This study compared buccal bone thickness, dental inclinations and maxillary transverse width dimensions changes between auxiliary beta-titanium expansion arch (AEA) and miniscrew-assisted rapid palatal expansion (MARPE). MATERIALS AND METHODS: The sample consisted of 29 patients, aged between 18 and 40 years, with transverse maxillary deficiency and treated without extractions, divided into two groups: group AEA: comprised 13 individuals (initial mean age: 29.23 ± 9.13 years) treated using auxiliary beta-titanium expansion arch; group MARPE: comprised 16 patients (initial mean age: 24.92 ± 7.60 years) treated with miniscrew-assisted rapid palatal expansion. Buccal bone thickness, dental inclinations and transverse width dimensions (dental, nasal base and jugular) were measured in cone-bean computed tomographies at pre- and post-treatment stages. The variables were compared using the independent t-test. RESULTS: The buccal bone thickness was similar for both groups at the post-treatment stage. The second premolars were significantly more buccal inclined in the AEA group and the right maxillary first molars in the MARPE group. The intercanine and intermolar distances were statistically significantly greater in the MARPE group. Changes in dental arch transverse dimensions were significantly greater for the MARPE group. CONCLUSION: Both treatment protocols corrected the maxillary transverse discrepancy; however, MARPE provided greater correction.


Assuntos
Parafusos Ósseos , Tomografia Computadorizada de Feixe Cônico , Maxila , Procedimentos de Ancoragem Ortodôntica , Técnica de Expansão Palatina , Titânio , Humanos , Técnica de Expansão Palatina/instrumentação , Maxila/diagnóstico por imagem , Titânio/química , Adulto , Adolescente , Feminino , Masculino , Adulto Jovem , Procedimentos de Ancoragem Ortodôntica/instrumentação , Desenho de Aparelho Ortodôntico , Arco Dental/diagnóstico por imagem , Arco Dental/patologia , Dente Molar/diagnóstico por imagem , Cefalometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA