Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 412
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 45(28): 2508-2515, 2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-38842324

RESUMO

BACKGROUND AND AIMS: Strategies to assess patients with suspected acute myocardial infarction (AMI) using a point-of-care (POC) high-sensitivity cardiac troponin I (hs-cTnI) assay may expedite emergency care. A 2-h POC hs-cTnI strategy for emergency patients with suspected AMI was derived and validated. METHODS: In two international, multi-centre, prospective, observational studies of adult emergency patients (1486 derivation cohort and 1796 validation cohort) with suspected AMI, hs-cTnI (Siemens Atellica® VTLi) was measured at admission and 2 h later. Adjudicated final diagnoses utilized the hs-cTn assay in clinical use. A risk stratification algorithm was derived and validated. The primary diagnostic outcome was index AMI (Types 1 and 2). The primary safety outcome was 30-day major adverse cardiac events incorporating AMI and cardiac death. RESULTS: Overall, 81 (5.5%) and 88 (4.9%) patients in the derivation and validation cohorts, respectively, had AMI. The 2-h algorithm defined 66.1% as low risk with a sensitivity of 98.8% [95% confidence interval (CI) 89.3%-99.9%] and a negative predictive value of 99.9 (95% CI 99.2%-100%) for index AMI in the derivation cohort. In the validation cohort, 53.3% were low risk with a sensitivity of 98.9% (95% CI 92.4%-99.8%) and a negative predictive value of 99.9% (95% CI 99.3%-100%) for index AMI. The high-risk metrics identified 5.4% of patients with a specificity of 98.5% (95% CI 96.6%-99.4%) and a positive predictive value of 74.5% (95% CI 62.7%-83.6%) for index AMI. CONCLUSIONS: A 2-h algorithm using a POC hs-cTnI concentration enables safe and efficient risk assessment of patients with suspected AMI. The short turnaround time of POC testing may support significant efficiencies in the management of the large proportion of emergency patients with suspected AMI.


Assuntos
Algoritmos , Infarto do Miocárdio , Troponina I , Humanos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/sangue , Masculino , Feminino , Estudos Prospectivos , Troponina I/sangue , Idoso , Pessoa de Meia-Idade , Sistemas Automatizados de Assistência Junto ao Leito , Biomarcadores/sangue , Medição de Risco/métodos , Sensibilidade e Especificidade , Testes Imediatos
2.
J Surg Res ; 300: 150-156, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38815513

RESUMO

INTRODUCTION: Blunt cardiac injury (BCI) can be challenging diagnostically, and if misdiagnosed, can lead to life-threatening complications. Our institution previously evaluated BCI screening with troponin and electrocardiogram (EKG) during a transition from troponin I to high sensitivity troponin (hsTnI), a more sensitive troponin I assay. The previous study found an hsTnI of 76 ng/L had the highest capability of accurately diagnosing a clinically significant BCI. The aim of this study was to determine the efficacy of the newly implemented protocol. METHODS: Patients diagnosed with a sternal fracture from March 2022 to April 2023 at our urban level-1 trauma center were retrospectively reviewed for EKG findings, hsTnI trend, echocardiogram changes, and clinical outcomes. The BCI cohort and non-BCI cohort ordinal measures were compared using Wilcoxon's two-tailed rank sum test and categorical measures were compared with Fisher's exact test. Youden indices were used to evaluate hsTnI sensitivity and specificity. RESULTS: Sternal fractures were identified in 206 patients, of which 183 underwent BCI screening. Of those screened, 103 underwent echocardiogram, 28 were diagnosed with clinically significant BCIs, and 15 received intervention. The peak hsTnI threshold of 76 ng/L was found to have a Youden index of 0.31. Rather, the Youden index was highest at 0.50 at 40 ng/L (sensitivity 0.79 and specificity 0.71) for clinically significant BCI. CONCLUSIONS: Screening patients with sternal fractures for BCI using hsTnI and EKG remains effective. To optimize the hsTnI threshold, this study determined the hsTnI threshold should be lowered to 40 ng/L. Further improvements to the institutional protocol may be derived from multicenter analysis.


Assuntos
Eletrocardiografia , Ferimentos não Penetrantes , Humanos , Feminino , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Adulto , Ferimentos não Penetrantes/diagnóstico , Ferimentos não Penetrantes/sangue , Idoso , Traumatismos Cardíacos/diagnóstico , Traumatismos Cardíacos/sangue , Troponina I/sangue , Esterno/lesões , Sensibilidade e Especificidade , Biomarcadores/sangue , Fraturas Ósseas/sangue , Fraturas Ósseas/diagnóstico , Ecocardiografia
3.
Clin Chem Lab Med ; 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39239902

RESUMO

OBJECTIVES: The objective of this study is to evaluate the analytical and diagnostic performance of a high-sensitivity point-of-care (POC) cardiac troponin I assay, the Quidel TriageTrue™ (QuidelOrtho Inc, San Diego, USA), compared to central laboratory testing (CLT) in accelerated diagnostic protocols (ADP) in real time in a clinical environment. METHODS: In a nested sub-study of a pragmatic randomised control trial, consecutive patients with suspected acute coronary syndrome (ACS) and chest pain <12 h duration were randomised to the ESC 0/1 and 0/3-h ADP. Subjects underwent sampling for Quidel TriageTrue POC hs-TnI whole blood and plasma, CLT hs-TnT Roche Elecsys and a validated, NICE approved CLT High sensitivity cardiac troponin I (hs-TnI) (Siemens Attellica) at each time point. Assay imprecision was assessed by repeat analysis of whole blood samples at three levels (low, near 10 % CV 5-10 ng/L, medium, approximating 99th percentile 15-25 ng/L and high, 3-5 times the 99th percentile, 60-100 ng/L). Final diagnosis was adjudicated at 6 weeks by Roche hs-TnT using the 4th universal definition of myocardial infarction (MI). RESULTS: A total of 1,157 patients consented and had both investigational POC whole blood and plasma and central lab hs-cTn available. The median age was 59, 47.2 % were female and 15 % had suffered a previous MI. Assay imprecision of whole blood POC TriageTrue revealed 10 % CV at 8.6 ng/L (>50 % lower than 99th percentile [20.5 ng/L]) and a 20 % CV at 1.2 ng/L. Receiver operator characteristics (ROC) curves were computed for each assay against adjudicated index type 1 MI to study clinical performance. At all-time points there were excellent performance for whole blood POC TriageTrue: area under the curve (AUC) 0.97 [95 % CI 0.94-098], 0.98 [95 % CI 0.97-1.00] and 0.95 [95 % CI 0.92-0.98] at time 0, 1 and 3 h respectively. There was statistical equivalence for performance of whole blood and plasma POC TriageTrue hs-TnI and laboratory Siemens Atellica hs-TnI. CONCLUSIONS: The whole blood POC TriageTrue hs-TnI assay demonstrates imprecision levels consistent with high sensitivity characteristics and has a clinical performance equivalent to an established, validated and NICE approved laboratory Siemens Atellica hs-TnI.

4.
Acta Anaesthesiol Scand ; 68(8): 1076-1084, 2024 09.
Artigo em Inglês | MEDLINE | ID: mdl-38819029

RESUMO

BACKGROUND: Patients with an out-of-hospital cardiac arrest (OHCA) often undergo coronary angiography, although a culprit lesion is found in only 30%-40% of patients. The aim of this study was to investigate high-sensitivity troponin T (hsTnT) levels in post cardiac arrest patients with and without coronary culprit lesions; factors affecting hsTnT levels after return of spontaneous circulation (ROSC); and the diagnostic ability of hsTnT in identifying patients with culprit lesions. We hypothesized that peak hsTnT levels were higher during the initial 48 h after cardiac arrest in patients with a coronary culprit lesion. METHODS: This was a retrospective observational study, which included patients admitted to the Intensive Care Unit after an OHCA and who received a coronary angiography. Peak values and dynamic changes in hsTnT were analyzed in relation to the presence of a culprit lesion at coronary angiography. RESULTS: A total of 238 patients were studied, of whom 140 had a culprit lesion. HsTnT levels during the initial 48 h were higher in patients with culprit lesions, longer time to ROSC and an unwitnessed cardiac arrest. At 6 to 12 h after ROSC, a hsTnT cut-off level of 1690 ng/L had a sensitivity of 64% and specificity of 84% to identify a culprit lesion. In patients without ST-elevations, hsTnT measured between 6 and 12 h after ROSC had a specificity above 90%, with a sensitivity of 46%. CONCLUSION: HsTnT levels after cardiac arrest are higher in patients with coronary culprit lesions. Presence of a culprit lesion, witnessed status and the duration of CPR are important factors affecting hsTnT levels. Repeated measurement of hsTnT within the first 12 h after admission improved diagnostic accuracy but the value of hsTnT as a predictor of culprit lesions early after OHCA is limited.


Assuntos
Angiografia Coronária , Parada Cardíaca Extra-Hospitalar , Troponina T , Humanos , Parada Cardíaca Extra-Hospitalar/sangue , Parada Cardíaca Extra-Hospitalar/complicações , Troponina T/sangue , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Sensibilidade e Especificidade , Biomarcadores/sangue
5.
Am J Emerg Med ; 76: 82-86, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38006636

RESUMO

BACKGROUND: High sensitivity cardiac troponins (hs-cTn) allow earlier identification and exclusion of acute myocardial infarction. We determined if transitioning from contemporary to high sensitivity troponin T (hs-cTnT) would reduce ED length of stay in chest pain (CP) patients. METHODS: We conducted a pragmatic, prospective, before and after study of implementing a hs-cTnT by reviewing the electronic health records in all adult ED patients presenting to a large, suburban academic medical center during the 3 months before and after transitioning from a 4th generation troponin to a 5th generation hs-cTnT (Elecsys® Troponin T-high sensitive, Roche Diagnostics, Indianapolis, IN). RESULTS: There were 1431 and 1437 CP patients before and after the intervention. Mean (SD) age was 51.5 (18) yrs. and 54.3% were female. The median (IQR) ED LOS for chest pain patients directly discharged to home was 6.2 (4.7-8.4) and 5.3 (4.0-7.2) hours before and after introducing hs-cTn respectively; difference 47 min (95%CI, 35-59); P < 0.001. The median (IQR) ED LOS for chest pain patients admitted to the hospital was 9.5 (6.6-13.8) and 8.1 (5.7-11.2) hours before and after introducing hs-cTn respectively; difference 77 min (95%CI, 35-121); P < 0.001. Overall admission rates (22 vs 21% both before and after) did not change during the study. The rates of computed tomography coronary angiography before and after the intervention were 21 and 20.4% respectively. The rates of invasive coronary angiography before and after the intervention were 5.8 and 5.6% respectively. CONCLUSIONS: Transitioning to a hs-cTnT is associated with a clinically relevant and statistically significant reduction in ED LOS for both discharged and admitted patients with and without CP with no increase in admission or coronary angiography rates.


Assuntos
Troponina T , Troponina , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Prospectivos , Tempo de Internação , Biomarcadores , Dor no Peito/diagnóstico , Serviço Hospitalar de Emergência
6.
Am J Emerg Med ; 80: 174-177, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38613986

RESUMO

BACKGROUND: Compared to conventional cardiac troponin (cTn), the high-sensitivity cardiac troponin (hs-cTn) assay is associated with improved detection of myocardial infarction (MI). METHODS: We performed a descriptive retrospective analysis of resource utilization at Rush University Medical Center over the transition period (July 1, 2021) from a cTn to a hs-cTn assay. Inclusion criteria included emergency department (ED) encounters between January 1 to December 31, 2021, with chief complaints of "chest pain" or "dyspnea" with associated troponin orders. The primary endpoint was the percentage of ED discharges. Secondary endpoints included the number of cardiac studies ordered. Univariable comparisons of these endpoints were performed using Student's t-test for continuous variables and Chi-square tests for binary/categorical variables. RESULTS: A total of 5113 encounters were analyzed. Hs-cTn was associated with an overall increase in ED patient discharges with negative troponin tests (44.1% vs. 29.9%, P < 0.01). In terms of cardiac testing per encounter, hs-cTn was associated with significant increases in the number of troponin tests (1.9 vs. 1.6, P < 0.01), electrocardiograms (3.0 vs. 2.9, P = 0.01), and echocardiograms (0.5 vs. 0.4, P < 0.01). There was a significant decrease in the utilization of stress testing (0.21 vs. 0.26, P < 0.01). There was a significant increase in total coronary angiography use during the hs-cTn period compared to cTn (227/2471 (9.2%) vs. 195/2642 (7.4%), P = 0.02). CONCLUSION: Transitioning from cTn to hs-cTn was associated with significantly increased ED discharges and an increase in troponin tests, ECG, echocardiograms, and coronary angiograms. There was a decrease in the number of stress tests.


Assuntos
Serviço Hospitalar de Emergência , Infarto do Miocárdio , Humanos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Serviço Hospitalar de Emergência/estatística & dados numéricos , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Idoso , Biomarcadores/sangue , Dor no Peito/sangue , Eletrocardiografia , Troponina/sangue , Troponina I/sangue , Angiografia Coronária
7.
Am J Emerg Med ; 79: 111-115, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38417221

RESUMO

BACKGROUND: The European Society of Cardiology (ESC) 0/1-h high sensitivity troponin T (hs-cTnT) algorithm does not differentiate risk based on known coronary artery disease (CAD: prior myocardial infarction [MI], coronary revascularization, or ≥ 70% coronary stenosis). We recently evaluated its performance among patients with known CAD at 30-days, but little is known about its longer-term risk prediction. The objective of this study is to determine and compare the performance of the algorithm at 90-days among patients with and without known CAD. METHODS: We performed a pre-planned subgroup analysis of the STOP-CP cohort, which prospectively enrolled ED patients ≥21 years old with symptoms suggestive of ACS without ST-elevation on initial ECG across 8 US sites (1/25/2017-9/6/2018). Participants with 0- and 1-h hs-cTnT measures (Roche, Basel, Switzerland) were stratified into rule-out, observe, and rule-in groups using the ESC 0/1-h algorithm. Algorithm performance was tested among patients with or without known CAD, as determined by the treating provider. The primary outcome was cardiac death or MI at 90-days. Fisher's exact tests were used to compare 90-day event and rule-out rates between patients with and without known CAD. Negative predictive values (NPVs) for 90-day cardiac death or MI with exact 95% confidence intervals were calculated and compared using Fisher's exact test. RESULTS: The STOP-CP study accrued 1430 patients, of which 31.4% (449/1430) had known CAD. Cardiac death or MI at 90 days was more common in patients with known CAD than in those without [21.2% (95/449) vs. 10.0% (98/981); p < 0.001]. Using the ESC 0/1-h algorithm, 39.6% (178/449) of patients with known CAD and 66.1% (648/981) of patients without known CAD were ruled-out (p < 0.001). Among rule-out patients, 90-day cardiac death or MI occurred in 3.4% (6/178) of patients with known CAD and 1.2% (8/648) without known CAD (p = 0.09). NPV for 90-day cardiac death or MI was 96.6% (95%CI 92.8-98.8) among patients with known CAD and 98.8% (95%CI 97.6-99.5) in patients without known CAD (p = 0.09). CONCLUSION: Patients with known CAD who were ruled-out using the ESC 0/1-h hs-cTnT algorithm had a high rate of missed 90-day cardiac events, suggesting that the ESC 0/1-h hs-cTnT algorithm may not be safe for use among patients with known CAD. TRIAL REGISTRATION: High-Sensitivity Cardiac Troponin T to Optimize Chest Pain Risk Stratification (STOP-CP; ClinicalTrials.gov: NCT02984436; https://clinicaltrials.gov/ct2/show/NCT02984436).


Assuntos
Cardiologia , Doença da Artéria Coronariana , Humanos , Adulto Jovem , Adulto , Troponina T , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Estudos Prospectivos , Algoritmos , Morte , Biomarcadores
8.
Pediatr Cardiol ; 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39126513

RESUMO

Cardiac troponin is commonly used to screen for cardiac diagnoses in pediatric patients, as it is only released by myocardial tissue. There is limited data regarding high-sensitivity troponin T in pediatric populations and its clinical interpretation. We sought to determine how high-sensitivity troponin values are associated with myocarditis diagnosis. High sensitivity troponin levels were reviewed for pediatric patients at our center from February 2022 to February 2023. Basic demographic and presenting data (including age, gender, body mass index), and diagnoses (cardiac diagnosis, including myocarditis, vs non-cardiac) were compared for patients with elevated initial troponin levels (≥ 12 ng/L) vs. those with non-elevated values. Of the 308 patients included, 91 (29.5%) had elevated hs-cTnT and 45 (14.6%) had a cardiac diagnosis, of whom 8 (2.5%) were ultimately diagnosed with acute myocarditis. There was no meaningful difference in demographic characteristics between the elevated and non-elevated hs-cTnT groups. For patients with diagnosis of myocarditis (n = 8), median peak levels were 506.5 ng/L (182.0 to 1184.0) versus 6.0 ng/L (< 6.0 to 13.5) for those with all other diagnoses (n = 300) (p < 0.001). A high sensitivity troponin cut-off value of 90 ng/dL was established for diagnosis of myocarditis, providing high sensitivity (100%) and specificity of (95%).

9.
Heart Lung Circ ; 33(3): 342-349, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38336541

RESUMO

BACKGROUND: The implementation of high-sensitivity cardiac troponin (hs-cTn) assays into clinical practice has resulted in the identification of a novel cohort of patients with modestly increased troponin concentrations. Subsequent increases in rates of coronary angiography have been observed, without significant increases in rates of coronary revascularisation. Computed tomography coronary angiography (CTCA) is a non-invasive investigation that offers the opportunity to decouple investigation from the impetus to revascularise, and may provide an alternative, more risk-appropriate initial investigative strategy for the cohort with low to moderate hs-cTn increases. This analysis seeks to define the threshold of pre-test probability of coronary revascularisation in patients with suspected acute coronary syndrome at which a strategy of initial CTCA is safe and a more cost-effective approach than standard invasive coronary angiography (ICA). METHODS: A cost-benefit evaluation was conducted using a decision-analytic model. The primary outcome measure was the incremental cost-effectiveness ratio (ICER) of CTCA in comparison with ICA as an initial diagnostic investigation for patients with hs-cTnT levels between 5 and 100 ng/L. Secondary outcome measures of costs, patient outcomes, and quality-adjusted life years were analysed. RESULTS: Median base case ICER over 1,000 trials was $17,163 AUD but demonstrated large variability. Sensitivity analysis demonstrated that CTCA was cost-effective until the probability of requiring revascularisation was ∼60%, beyond which point CTCA was associated with higher costs and poorer outcomes than ICA. CONCLUSIONS: Computed tomography coronary angiography may be a cost-effective first-line investigation for patients with moderate hs-cTnT rises until/up to a 60% pre-test probability for receiving coronary revascularisation. To objectively assess the optimal circumstances of cost-effectiveness, prospective evaluation incorporating the estimated probability of revascularisation will be required.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/diagnóstico , Síndrome Coronariana Aguda/diagnóstico , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X , Troponina
10.
Eur J Clin Invest ; 53(5): e13950, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36602448

RESUMO

AIMS: Atrial fibrillation (AF) is becoming increasingly common. Traditional cardiovascular risk factors (CVRF) do not explain all AF cases. Blood-based biomarkers reflecting cardiac injury such as high-sensitivity troponin I (hsTnI) may help close this gap. METHODS: We investigated the predictive ability of hsTnI for incident AF in 45,298 participants (median age 51.4 years, 45.0% men) across European community cohorts in comparison to CVRF and established biomarkers (C-reactive protein, N-terminal pro B-type natriuretic peptide). RESULTS: During a median follow-up of 7.7 years, 1734 (3.8%) participants developed AF. Those in the highest hsTnI quarter (≥4.2 ng/L) had a 3.91-fold (95% confidence interval (CI) 3.30, 4.63; p < .01) risk for developing AF compared to the lowest quarter (<1.4 ng/L). In multivariable-adjusted Cox proportional hazards models a statistically significant association was seen between hsTnI and AF (hazard ratio (HR) per 1 standard deviation (SD) increase in log10(hsTnI) 1.08; 95% CI 1.01, 1.16; p = .03). Inclusion of hsTnI did improve model discrimination (C-index CVRF 0.811 vs. C-index CVRF and hsTnI 0.813; p < .01). Higher hsTnI concentrations were associated with heart failure (HR per SD 1.37; 95% CI 1.12, 1.68; p < .01) and overall mortality (HR per SD 1.24; 95% CI 1.09, 1.41; p < .01). CONCLUSION: hsTnI as a biomarker of myocardial injury does not improve prediction of AF incidence beyond classical CVRF and NT-proBNP. However, it is associated with the AF-related disease heart failure and mortality likely reflecting underlying subclinical cardiovascular impairment.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Fibrilação Atrial/epidemiologia , Troponina I , Fatores de Risco , Biomarcadores , Insuficiência Cardíaca/epidemiologia , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos
11.
J Surg Res ; 281: 104-111, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36152398

RESUMO

INTRODUCTION: Screening for blunt cardiac injury (BCI) includes obtaining a serum troponin level and an electrocardiogram for patients diagnosed with a sternal fracture. Our institution has transitioned to the use of a high sensitivity troponin I (hsTnI). The aim of this study was to determine whether hsTnI is comparable to troponin I (TnI) in identifying clinically significant BCI. MATERIALS AND METHODS: Trauma patients presenting to a level I trauma center over a 24-mo period with the diagnosis of sternal fracture were screened for BCI. Any initial TnI more than 0.04 ng/mL or hsTnI more than 18 ng/L was considered positive for potential BCI. Clinically significant BCI was defined as a new-bundle branch block, ST wave change, echocardiogram change, or need for cardiac catheterization. RESULTS: Two hundred sixty five patients with a sternal fracture were identified, 161 underwent screening with TnI and 104 with hsTnI. For TnI, the sensitivity and specificity for detection of clinically significant BCI was 0.80 and 0.79, respectively. For hsTnI, the sensitivity and specificity for detection of clinically significant BCI was 0.71 and 0.69, respectively. A multivariate analysis demonstrated the odds ratio for significant BCI with a positive TnI was 14.4 (95% confidence interval, 3.9-55.8, P < 0.0001) versus an odds ratio of 5.48 (95% confidence interval 1.9-15.7, P = 0.002) in the hsTnI group. CONCLUSIONS: The sensitivity of hsTnI is comparable to TnI for detection of significant BCI. Additional investigation is needed to determine the necessity and interval for repeat testing and the need for additional diagnostic testing.


Assuntos
Contusões Miocárdicas , Traumatismos Torácicos , Humanos , Troponina I , Sensibilidade e Especificidade , Eletrocardiografia , Biomarcadores
12.
Cerebrovasc Dis ; 52(2): 153-159, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35908539

RESUMO

INTRODUCTION: Early recognition and risk stratification of cardiovascular events are necessary in patients after ischemic stroke. Recent evidence suggests that elevated high-sensitive cardiac troponin is a predictor of mortality and vascular events. Therefore, we aimed to explore the prognostic role of high-sensitive cardiac troponin I (hs-TnI) on mortality and cardiovascular outcomes in patients after ischemic stroke. METHODS: From August 2014 to July 2017, 1,506 patients with acute ischemic stroke were pulled consecutively in a retrospective single-center registry. Of these, 1,019 patients were selected and classified into the elevated or non-elevated hs-TnI groups according to hs-TnI level of 99th percentile upper reference limit (URL) at the time of admission for ischemic stroke. The primary outcome was a major adverse cardiac and cerebrovascular event (MACCE) during follow-up. RESULTS: Among 1,019 patients, 708 patients were non-elevated hs-TnI group (<99th percentile URL of hs-TnI) and 311 patients were elevated hs-TnI group (≥99th percentile URL of hs-TnI). The median follow-up period was 22.5 (interquartile range 5.0-38.8) months. In a multivariable Cox regression model, the elevated hs-TnI group has a higher risk of MACCE (adjusted hazard ratio [HR]: 3.12; 95% confidence interval [CI]: 2.33-4.17; p < 0.01), all-cause mortality (adjusted HR: 4.15; 95% CI: 2.47-6.99; p < 0.01) and readmission caused by coronary revascularization (adjusted HR: 3.12; 95% CI: 1.41-6.90; p < 0.01), heart failure (adjusted HR: 2.76; 95% CI: 1.38-5.51; p < 0.01), and stroke (adjusted HR: 1.73; 95% CI: 1.07-2.78; p = 0.02) compared with the non-elevated hs-TnI group. CONCLUSIONS: Elevated hs-TnI is independently associated with higher mortality and cardiac and cerebrovascular events in patients with ischemic stroke and may serve as a valuable prognostic factor in management after ischemic stroke.


Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Troponina I , Estudos Retrospectivos , Prognóstico , Biomarcadores , Troponina T
13.
Circ J ; 87(10): 1362-1368, 2023 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-37394574

RESUMO

BACKGROUND: This study investigated the economic impact of the European Society of Cardiology (ESC) clinical practice guideline recommendation of using the 0-h/1-h rule-out and rule-in algorithm with high-sensitivity cardiac troponin assays (0/1-h algorithm) to triage patients presenting with chest pain.Methods and Results: This post hoc cost-effectiveness evaluation (DROP-ACS; UMIN000030668) used deidentified electronic medical records from health insurance claims from 2 diagnostic centers in Japan. A cost-effectiveness analysis was conducted with 472 patients with care provided following the 0/1-h algorithm (Hospital A) and 427 patients following point-of-care testing (Hospital B). The clinical outcome of interest was all-cause mortality or subsequent myocardial infarction within 30 days of the index presentation. The sensitivity and specificity for the clinical outcome were 100% (95% confidence interval [CI] 91.1-100%) and 95.0% (95% CI 94.3-95.0%), respectively, in Hospital A and 92.9% (95% CI 69.6-98.7%) and 89.8% (95% CI 89.0-90.0%), respectively, in Hospital B. If the diagnostic accuracy of the 0/1-h algorithm was implemented in Hospital B, it is expected that the number of urgent (<24-h) coronary angiograms would decrease by 50%. Incorporating this assumption, implementing the 0/1-h algorithm could potentially reduce medical costs by JPY4,033,874 (95% CI JPY3,440,346-4,627,402) in Hospital B (JPY9,447 per patient; 95% CI JPY 8,057-10,837 per patient). CONCLUSIONS: The ESC 0/1-h algorithm was efficient for risk stratification and for reducing medical costs.


Assuntos
Infarto do Miocárdio , Humanos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/complicações , Dor no Peito/diagnóstico , Serviço Hospitalar de Emergência , Sensibilidade e Especificidade , Algoritmos , Troponina T , Biomarcadores
14.
Scand Cardiovasc J ; 57(1): 2272585, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37905548

RESUMO

OBJECTIVES: Patients presenting with symptoms suggestive of acute coronary syndrome (ACS) contribute to a high workload and overcrowding in the Emergency Department (ED). Accelerated diagnostic protocols for non-ST-elevation myocardial infarction have proved challenging to implement. One obstacle is the turnaround time for analyzing high-sensitivity cardiac troponin (hs-cTn). In the WESTCOR-POC study (Clinical Trials number NCT05354804) we aim to evaluate safety and efficiency of a 0/1 h hs-cTn algorithm utilizing a hs-cTnI point of care (POC) instrument in comparison to central laboratory hs-cTnT measurements. DESIGN: This is a prospective single-center randomized clinical trial aiming to include 1500 patients admitted to the ED with symptoms suggestive of ACS. Patients will receive standard investigations following the European Society of Cardiology 0/1h protocols for centralized hs-cTnT measurements or the intervention using a 0/1h POC hs-cTnI algorithm. Primary end-points are 1) Safety; death, myocardial infarction or acute revascularization within 30 days 2) Efficiency; length of stay in the ED, 3) Cost- effectiveness; total episode cost, 4) Patient satisfaction, 5) Patient symptom burden and 6) Patients quality of life. Secondary outcomes are 12-months death, myocardial infarction or acute revascularization, percentage discharged after 3 and 6 h, total length of hospital stay and all costs related to hospital contact within 12 months. CONCLUSION: Results from this study may facilitate implementation of POC hs-cTn testing assays and accelerated diagnostic protocols in EDs, and may serve as a valuable resource for guiding future investigations for the use of POC high sensitivity troponin assays in outpatient clinics and prehospital settings.


Assuntos
Síndrome Coronariana Aguda , Infarto do Miocárdio , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Qualidade de Vida , Infarto do Miocárdio/diagnóstico , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/terapia , Troponina I , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Testes Imediatos , Biomarcadores , Troponina T
15.
Heart Vessels ; 38(1): 1-7, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35794488

RESUMO

BACKGROUND: A critical and unmet therapeutic need is the prompt and reliable exclusion of acute myocardial infarction (AMI), which would allow for prompt discharge from the emergency department. High-sensitivity troponin (HS-TnT) combined with copeptin has been proposed to expedite the diagnostic exclusion of AMI in addition to its predictive usefulness in the intermediate and long-term outcomes of AMI. The European Society of Cardiology recommends the Global Registry of Acute Coronary Events (GRACE) as a prognostic score to manage acute coronary syndrome (ACS) without ST segment elevation. The purpose of this study was to compare the diagnostic accuracy of HS-TnT combined with copeptin in ruling out AMI compared to HS-TnT alone. By combining a low GRACE score (108) with negative HS-TnT (14 ng/L) and copeptin (14 pmol/L), non-ST and ACS were reliably ruled out, including non-ST segment elevation MI and unstable angina. RESULTS: The present research included nine studies with a total of 13,232 participants. The negative predictive value (NPV) for copeptin and HS-TnT was found to be slightly higher in combination (62-99%) than for HS-TnT alone (60-99%). The sensitivity of copeptin ranged from 0% to 100%, with a pooled sensitivity of 0.79 (CI 95% 0.76, 0.82). The specificity of copeptin ranged from 13% to 100%, with a pooled specificity of 0.89 (CI 95% 0.85, 0.91), a pooled positive likelihood ratio (PLR) of 9.86 (CI 95% 4.42, 22.02), and a pooled negative likelihood ratio (NLR) of 0.08. (95% CI 0.01, 0.44). CONCLUSIONS: The use of combined negative copeptin and highly sensitive troponin testing in low-to-intermediate risk patients with suspected acute coronary syndrome resulted in a quick discharge with a safe and rapid rule out of non-ST + ACS.


Assuntos
Síndrome Coronariana Aguda , Infarto do Miocárdio , Humanos , Troponina , Prognóstico , Síndrome Coronariana Aguda/diagnóstico , Biomarcadores , Dor no Peito/diagnóstico , Infarto do Miocárdio/diagnóstico , Glicopeptídeos , Valor Preditivo dos Testes , Troponina T
16.
Am J Emerg Med ; 72: 64-71, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37494772

RESUMO

BACKGROUND: Among persons presenting to the emergency department with suspected acute myocardial infarction (MI), cardiac troponin (cTn) testing is commonly used to detect acute myocardial injury. Accelerated diagnostic protocols (ADPs) guide clinicians to integrate cTn results with other clinical information to decide whether to order further diagnostic testing. OBJECTIVE: To determine the change in the rate and yield of stress test or coronary CT angiogram following cTn measurement in patients with chest pain presenting to the emergency department pre- and post-transition to a high-sensitivity (hs-cTn) assay in an updated ADP. METHODS: Using electronic health records, we examined visits for chest pain at five emergency departments affiliated with an integrated academic health system 1-year pre- and post-hs-cTn assay transition. Outcomes included stress test or coronary imaging frequency, ADP compliance among those with additional testing, and diagnostic yield (ratio of positive tests to total tests). RESULTS: There were 7564 patient-visits for chest pain, including 3665 in the pre- and 3899 in the post-period. Following the updated ADP using hs-cTn, 862 (23.5 per 100 patient visits) visits led to subsequent testing versus 1085 (27.8 per 100 patient visits) in the pre-hs-cTn period, (P < 0.001). Among those who were tested, the protocol-compliant rate fell from 80.9% to 46.5% (P < 0.001), but the yield of those tests rose from 24.5% to 29.2% (P = 0.07). Among tests that were noncompliant with ADP guidance, yield was similar pre- and post-updated hs-cTn ADP implementation (pre 13.0%, post 15.4% (P = 0.43). CONCLUSION: Implementation of hs-cTn supported by an updated ADP was associated with a lower rate of stress testing and coronary CT angiogram.


Assuntos
Infarto do Miocárdio , Troponina , Humanos , Infarto do Miocárdio/diagnóstico , Coração , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Serviço Hospitalar de Emergência , Biomarcadores , Troponina T
17.
Can J Anaesth ; 70(11): 1776-1788, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37853279

RESUMO

PURPOSE: Myocardial injury after noncardiac surgery is common and mostly asymptomatic. The ideal target population that will benefit from routine troponin measurements in low and middle income countries (LMICs) is unclear. This study aims to evaluate the clinical outcomes of a cohort of high-risk surgical patients according to high-sensitivity troponin T (hsTnT) in an LMIC setting. METHODS: We conducted a prospective cohort study of 442 high-risk patients undergoing noncardiac surgery at a Brazilian hospital between February 2019 and March 2020. High-sensitivity troponin T levels were measured preoperatively, 24 hr, and 48 hr after surgery and stratified into three groups: normal (< 20 ng·L-1); minor elevation (20-65 ng·L-1); and major elevation (> 65 ng·L-1). We performed survival analysis to determine the association between myocardial injury and one-year mortality. We described medical interventions and evaluated unplanned intensive care unit (ICU) admission and complications using multivariable models. RESULTS: Postoperative myocardial injury occurred in 45% of patients. Overall, 30-day mortality was 8%. Thirty-day and one-year mortality were higher in patients with hsTnT ≥ 20 ng·L-1. One-year mortality was 18% in the unaltered troponin group vs 31% and 41% for minor and major elevation groups, respectively. Multivariable analysis of one-year survival showed a hazard ratio (HR) of 1.94 (95% confidence interval [CI], 1.22 to 3.09) for the minor elevation group and a HR of 2.73 (95% CI, 1.67 to 4.45) for the troponin > 65 ng·L-1 group. Patients with altered troponin had more unplanned ICU admissions (13% vs 5%) and more complications (78% vs 48%). CONCLUSION: This study supports evidence that hsTnT is an important prognostic marker and a strong predictor of all-cause mortality after surgery. Troponin measurement in high-risk surgical patients could potentially be used as tool to scale-up care in LMIC settings. STUDY REGISTRATION: ClinicalTrials.gov (NCT04187664); first submitted 5 December 2019.


RéSUMé: OBJECTIF: Les lésions myocardiques après une chirurgie non cardiaque sont courantes et la plupart du temps asymptomatiques. Nous ne connaissons pas la population cible idéale qui bénéficierait de mesures régulières de la troponine dans les pays à revenu faible et intermédiaire (PRFI). Cette étude vise à évaluer les issues cliniques d'une cohorte de patient·es de chirurgie à haut risque grâce à la troponine T à haute sensibilité (hsTnT) dans un contexte de PRFI. MéTHODE: Nous avons mené une étude de cohorte prospective auprès de 442 patient·es à haut risque bénéficiant d'une chirurgie non cardiaque dans un hôpital brésilien entre février 2019 et mars 2020. Les taux de troponine T à haute sensibilité ont été mesurés avant l'opération, 24 heures et 48 heures après la chirurgie, et stratifiés en trois groupes : normaux (< 20 ng·L−1), élévation mineure (20­65 ng·L−1) et élévation majeure (> 65 ng·L−1). Nous avons réalisé une analyse de survie pour déterminer l'association entre les lésions myocardiques et la mortalité à un an. Nous avons décrit les interventions médicales et évalué les admissions non planifiées à l'unité de soins intensifs (USI) ainsi que les complications à l'aide de modèles multivariables. RéSULTATS: Une lésion myocardique postopératoire est survenue chez 45 % des patient·es. La mortalité globale à 30 jours était de 8 %. La mortalité à trente jours et à un an était plus élevée chez les patient·es avec une hsTnT ≥ 20 ng·L−1. La mortalité à un an était de 18 % dans le groupe troponine inchangée vs 31 % et 41 % pour les groupes à élévation mineure et majeure de la troponine, respectivement. L'analyse multivariée de la survie à un an a montré un rapport de risque (RR) de 1,94 (intervalle de confiance [IC] à 95 %, 1,22 à 3,09) pour le groupe d'élévation mineure et un RR de 2,73 (IC 95 %, 1,67 à 4,45) pour le groupe avec une troponine > 65 ng·L−1. Les admissions non planifiées à l'USI étaient plus fréquentes chez les patient·es présentant une troponine altérée (13 % vs 5 %), tout comme les complications (78 % vs 48 %). CONCLUSION: Cette étude soutient les données probantes selon lesquelles la hsTnT est un marqueur pronostique important et un prédicteur fort de la mortalité toutes causes confondues après la chirurgie. La mesure de la troponine chez la patientèle chirurgicale à risque élevé pourrait potentiellement être utilisée comme outil pour intensifier les soins dans les PRFI. ENREGISTREMENT DE L'éTUDE: ClinicalTrials.gov (NCT04187664); soumis pour la première fois le 5 décembre 2019.


Assuntos
Países em Desenvolvimento , Troponina , Humanos , Troponina T , Estudos Prospectivos , Medição de Risco , Biomarcadores
18.
BMC Med Inform Decis Mak ; 23(1): 25, 2023 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-36732708

RESUMO

AIMS: In the present study, we aimed to evaluate the performance of machine learning (ML) models for identification of acute myocardial infarction (AMI) or death within 30 days among emergency department (ED) chest pain patients. METHODS AND RESULTS: Using data from 9519 consecutive ED chest pain patients, we created ML models based on logistic regression or artificial neural networks. Model inputs included sex, age, ECG and the first blood tests at patient presentation: High sensitivity TnT (hs-cTnT), glucose, creatinine, and hemoglobin. For a safe rule-out, the models were adapted to achieve a sensitivity > 99% and a negative predictive value (NPV) > 99.5% for 30-day AMI/death. For rule-in, we set the models to achieve a specificity > 90% and a positive predictive value (PPV) of > 70%. The models were also compared with the 0 h arm of the European Society of Cardiology algorithm (ESC 0 h); An initial hs-cTnT < 5 ng/L for rule-out and ≥ 52 ng/L for rule-in. A convolutional neural network was the best model and identified 55% of the patients for rule-out and 5.3% for rule-in, while maintaining the required sensitivity, specificity, NPV and PPV levels. ESC 0 h failed to reach these performance levels. DISCUSSION: An ML model based on age, sex, ECG and blood tests at ED arrival can identify six out of ten chest pain patients for safe early rule-out or rule-in with no need for serial blood tests. Future studies should attempt to improve these ML models further, e.g. by including additional input data.


Assuntos
Infarto do Miocárdio , Troponina T , Humanos , Estudos Prospectivos , Biomarcadores , Infarto do Miocárdio/diagnóstico , Dor no Peito/diagnóstico , Valor Preditivo dos Testes , Eletrocardiografia , Serviço Hospitalar de Emergência
19.
Int J Mol Sci ; 24(24)2023 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-38139114

RESUMO

Numerous studies have been published suggesting that troponin levels are related to adverse outcomes in chronic cardiac and non-cardiac conditions. Our study investigated whether troponin levels gathered from unselected blood samples taken during outpatient care are associated with adverse outcomes in a population with stable coronary artery disease. In a cohort of 949 patients with stable coronary artery disease, an average age of 67.5 ± 9.5 years, 69.5% male, 52.1% diabetics, 51.6% with previous myocardial infarction, and 57.9% with triple-vessel disease, 21.7% of patients encountered new events during an average period of monitoring of 2.07 ± 0.81 years. Troponin I/99th percentile categorized into tertiles emerged as an independent predictor of death and combined events risk (hazard ratio: 2.02 (1.13-3.60), p = 0.017; 2.30 (1.37-3.88, p = 0.002, respectively). A troponin ratio > 0.24 was able to identify 53.3% of patients at risk of death and heart failure hospitalization. In patients with stable coronary artery disease who are adherent to treatment, troponin levels are independently associated with death and heart failure hospitalization in a medium-term follow-up.


Assuntos
Doença da Artéria Coronariana , Insuficiência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Troponina I , Pacientes Ambulatoriais , Biomarcadores
20.
Int Heart J ; 64(4): 590-595, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37518339

RESUMO

The European Society of Cardiology recommends the 0/1-hour algorithm for risk stratification of patients with suspected non-ST-elevation myocardial infarction as class I, level B; however, there are few reports on the long-term prognosis, resulting in a rule-out group. We aimed to determine whether implementation of the 0-hour/1-hour algorithm is safe and effective in emergency department (ED) patients with possible acute coronary syndrome (ACS) through a 1-year follow-up period. Our study analyzed the 1-year follow-up data from a prospective pre-post study of 1106 ED patients with possible ACS from 4 hospitals in Japan and Taiwan. Patients were 18 years or older. Accrual occurred for 1 year after implementing the 0-1-hour algorithm from November 2014 to December 2018. Overall, 520 patients were stratified into the rule-out group. Major advanced cardiovascular events (all-cause death, acute myocardial infarction [AMI], stroke, unstable angina, and revascularization) at 1-year were determined using data from health records and phone calls. The 0-1-hour algorithm stratified 47.0% of patients in the rule-out group. Over the 1-year follow-up period (follow-up rate = 86.9%), cardiovascular death and subsequent AMI did not occur in the rule-out group. Among the 27 patients who underwent the procedure within 30 days post-index visit, 3 patients (0.7%) had a stroke, 6 patients (1.3%) died of non-cardiovascular cause, and 30 patients (6.7%) underwent coronary revascularization within 1 year. At the 1-year follow-up, implementation of the 0-hour/1-hour algorithm was associated with very low rates of adverse event among patients in the rule-out group.


Assuntos
Síndrome Coronariana Aguda , Infarto do Miocárdio , Acidente Vascular Cerebral , Humanos , Estudos Prospectivos , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/diagnóstico , Serviço Hospitalar de Emergência , Dor no Peito , Algoritmos , Troponina T , Biomarcadores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA