Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.972
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 121(33): e2407971121, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39110725

RESUMO

Artificial neuromorphic devices can emulate dendric integration, axonal parallel transmission, along with superior energy efficiency in facilitating efficient information processing, offering enormous potential for wearable electronics. However, integrating such circuits into textiles to achieve biomimetic information perception, processing, and control motion feedback remains a formidable challenge. Here, we engineer a quasi-solid-state iontronic synapse fiber (ISF) comprising photoresponsive TiO2, ion storage Co-MoS2, and an ion transport layer. The resulting ISF achieves inherent short-term synaptic plasticity, femtojoule-range energy consumption, and the ability to transduce chemical/optical signals. Multiple ISFs are interwoven into a synthetic neural fabric, allowing the simultaneous propagation of distinct optical signals for transmitting parallel information. Importantly, IFSs with multiple input electrodes exhibit spatiotemporal information integration. As a proof of concept, a textile-based multiplexing neuromorphic sensorimotor system is constructed to connect synaptic fibers with artificial fiber muscles, enabling preneuronal sensing information integration, parallel transmission, and postneuronal information output to control the coordinated motor of fiber muscles. The proposed fiber system holds enormous promise in wearable electronics, soft robotics, and biomedical engineering.


Assuntos
Sinapses , Têxteis , Sinapses/fisiologia , Dispositivos Eletrônicos Vestíveis , Biomimética/métodos , Biomimética/instrumentação , Humanos , Plasticidade Neuronal/fisiologia
2.
Proc Natl Acad Sci U S A ; 120(6): e2217828120, 2023 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-36716364

RESUMO

Thermal sensations contribute to our ability to perceive and explore the physical world. Reproducing these sensations in a spatiotemporally programmable manner through wireless computer control could enhance virtual experiences beyond those supported by video, audio and, increasingly, haptic inputs. Flexible, lightweight and thin devices that deliver patterns of thermal stimulation across large areas of the skin at any location of the body are of great interest in this context. Applications range from those in gaming and remote socioemotional communications, to medical therapies and physical rehabilitation. Here, we present a set of ideas that form the foundations of a skin-integrated technology for power-efficient generation of thermal sensations across the skin, with real-time, closed-loop control. The systems exploit passive cooling mechanisms, actively switchable thermal barrier interfaces, thin resistive heaters and flexible electronics configured in a pixelated layout with wireless interfaces to portable devices, the internet and cloud data infrastructure. Systematic experimental studies and simulation results explore the essential mechanisms and guide the selection of optimized choices in design. Demonstration examples with human subjects feature active thermoregulation, virtual social interactions, and sensory expansion.


Assuntos
Pele , Realidade Virtual , Humanos , Eletrônica , Sensação Térmica , Comunicação
3.
Proc Natl Acad Sci U S A ; 120(9): e2219394120, 2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-36802437

RESUMO

Vocal fatigue is a measurable form of performance fatigue resulting from overuse of the voice and is characterized by negative vocal adaptation. Vocal dose refers to cumulative exposure of the vocal fold tissue to vibration. Professionals with high vocal demands, such as singers and teachers, are especially prone to vocal fatigue. Failure to adjust habits can lead to compensatory lapses in vocal technique and an increased risk of vocal fold injury. Quantifying and recording vocal dose to inform individuals about potential overuse is an important step toward mitigating vocal fatigue. Previous work establishes vocal dosimetry methods, that is, processes to quantify vocal fold vibration dose but with bulky, wired devices that are not amenable to continuous use during natural daily activities; these previously reported systems also provide limited mechanisms for real-time user feedback. This study introduces a soft, wireless, skin-conformal technology that gently mounts on the upper chest to capture vibratory responses associated with vocalization in a manner that is immune to ambient noises. Pairing with a separate, wirelessly linked device supports haptic feedback to the user based on quantitative thresholds in vocal usage. A machine learning-based approach enables precise vocal dosimetry from the recorded data, to support personalized, real-time quantitation and feedback. These systems have strong potential to guide healthy behaviors in vocal use.


Assuntos
Canto , Distúrbios da Voz , Voz , Humanos , Retroalimentação , Distúrbios da Voz/etiologia , Voz/fisiologia , Prega Vocal/fisiologia
4.
Circulation ; 149(19): e1134-e1142, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38545775

RESUMO

Wearable biosensors (wearables) enable continual, noninvasive physiologic and behavioral monitoring at home for those with pediatric or congenital heart disease. Wearables allow patients to access their personal data and monitor their health. Despite substantial technologic advances in recent years, issues with hardware design, data analysis, and integration into the clinical workflow prevent wearables from reaching their potential in high-risk congenital heart disease populations. This science advisory reviews the use of wearables in patients with congenital heart disease, how to improve these technologies for clinicians and patients, and ethical and regulatory considerations. Challenges related to the use of wearables are common to every clinical setting, but specific topics for consideration in congenital heart disease are highlighted.


Assuntos
American Heart Association , Técnicas Biossensoriais , Cardiopatias Congênitas , Dispositivos Eletrônicos Vestíveis , Humanos , Cardiopatias Congênitas/diagnóstico , Técnicas Biossensoriais/instrumentação , Estados Unidos
5.
Annu Rev Biomed Eng ; 26(1): 331-355, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38959390

RESUMO

Recent advancements in soft electronic skin (e-skin) have led to the development of human-like devices that reproduce the skin's functions and physical attributes. These devices are being explored for applications in robotic prostheses as well as for collecting biopotentials for disease diagnosis and treatment, as exemplified by biomedical e-skins. More recently, machine learning (ML) has been utilized to enhance device control accuracy and data processing efficiency. The convergence of e-skin technologies with ML is promoting their translation into clinical practice, especially in healthcare. This review highlights the latest developments in ML-reinforced e-skin devices for robotic prostheses and biomedical instrumentations. We first describe technological breakthroughs in state-of-the-art e-skin devices, emphasizing technologies that achieve skin-like properties. We then introduce ML methods adopted for control optimization and pattern recognition, followed by practical applications that converge the two technologies. Lastly, we briefly discuss the challenges this interdisciplinary research encounters in its clinical and industrial transition.


Assuntos
Aprendizado de Máquina , Robótica , Dispositivos Eletrônicos Vestíveis , Humanos , Robótica/métodos , Pele , Desenho de Equipamento , Engenharia Biomédica/métodos
6.
Circ Res ; 132(5): 652-670, 2023 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-36862812

RESUMO

Wearable devices, such as smartwatches and activity trackers, are commonly used by patients in their everyday lives to manage their health and well-being. These devices collect and analyze long-term continuous data on measures of behavioral or physiologic function, which may provide clinicians with a more comprehensive view of a patients' health compared with the traditional sporadic measures captured by office visits and hospitalizations. Wearable devices have a wide range of potential clinical applications ranging from arrhythmia screening of high-risk individuals to remote management of chronic conditions such as heart failure or peripheral artery disease. As the use of wearable devices continues to grow, we must adopt a multifaceted approach with collaboration among all key stakeholders to effectively and safely integrate these technologies into routine clinical practice. In this Review, we summarize the features of wearable devices and associated machine learning techniques. We describe key research studies that illustrate the role of wearable devices in the screening and management of cardiovascular conditions and identify directions for future research. Last, we highlight the challenges that are currently hindering the widespread use of wearable devices in cardiovascular medicine and provide short- and long-term solutions to promote increased use of wearable devices in clinical care.


Assuntos
Fármacos Cardiovasculares , Insuficiência Cardíaca , Doença Arterial Periférica , Dispositivos Eletrônicos Vestíveis , Humanos , Hospitalização
7.
Brain ; 147(6): 2038-2052, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38195196

RESUMO

In Parkinson's disease, imbalances between 'antikinetic' and 'prokinetic' patterns of neuronal oscillatory activity are related to motor dysfunction. Invasive brain recordings from the motor network have suggested that medical or surgical therapy can promote a prokinetic state by inducing narrowband gamma rhythms (65-90 Hz). Excessive narrowband gamma in the motor cortex promotes dyskinesia in rodent models, but the relationship between narrowband gamma and dyskinesia in humans has not been well established. To assess this relationship, we used a sensing-enabled deep brain stimulator system, attached to both motor cortex and basal ganglia (subthalamic or pallidal) leads, paired with wearable devices that continuously tracked motor signs in the contralateral upper limbs. We recorded 984 h of multisite field potentials in 30 hemispheres of 16 subjects with Parkinson's disease (2/16 female, mean age 57 ± 12 years) while at home on usual antiparkinsonian medications. Recordings were done 2-4 weeks after implantation, prior to starting therapeutic stimulation. Narrowband gamma was detected in the precentral gyrus, subthalamic nucleus or both structures on at least one side of 92% of subjects with a clinical history of dyskinesia. Narrowband gamma was not detected in the globus pallidus. Narrowband gamma spectral power in both structures co-fluctuated similarly with contralateral wearable dyskinesia scores (mean correlation coefficient of ρ = 0.48 with a range of 0.12-0.82 for cortex, ρ = 0.53 with a range of 0.5-0.77 for subthalamic nucleus). Stratification analysis showed the correlations were not driven by outlier values, and narrowband gamma could distinguish 'on' periods with dyskinesia from 'on' periods without dyskinesia. Time lag comparisons confirmed that gamma oscillations herald dyskinesia onset without a time lag in either structure when using 2-min epochs. A linear model incorporating the three oscillatory bands (beta, theta/alpha and narrowband gamma) increased the predictive power of dyskinesia for several subject hemispheres. We further identified spectrally distinct oscillations in the low gamma range (40-60 Hz) in three subjects, but the relationship of low gamma oscillations to dyskinesia was variable. Our findings support the hypothesis that excessive oscillatory activity at 65-90 Hz in the motor network tracks with dyskinesia similarly across both structures, without a detectable time lag. This rhythm may serve as a promising control signal for closed-loop deep brain stimulation using either cortical or subthalamic detection.


Assuntos
Estimulação Encefálica Profunda , Ritmo Gama , Córtex Motor , Doença de Parkinson , Humanos , Doença de Parkinson/fisiopatologia , Feminino , Masculino , Pessoa de Meia-Idade , Ritmo Gama/fisiologia , Estimulação Encefálica Profunda/métodos , Córtex Motor/fisiopatologia , Idoso , Adulto , Discinesias/fisiopatologia , Discinesias/etiologia , Núcleo Subtalâmico/fisiopatologia , Rede Nervosa/fisiopatologia
8.
Proc Natl Acad Sci U S A ; 119(35): e2202118119, 2022 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-35994641

RESUMO

Textiles hold great promise as a soft yet durable material for building comfortable robotic wearables and assistive devices at low cost. Nevertheless, the development of smart wearables composed entirely of textiles has been hindered by the lack of a viable sheet-based logic architecture that can be implemented using conventional fabric materials and textile manufacturing processes. Here, we develop a fully textile platform for embedding pneumatic digital logic in wearable devices. Our logic-enabled textiles support combinational and sequential logic functions, onboard memory storage, user interaction, and direct interfacing with pneumatic actuators. In addition, they are designed to be lightweight, easily integrable into regular clothing, made using scalable fabrication techniques, and durable enough to withstand everyday use. We demonstrate a textile computer capable of input-driven digital logic for controlling untethered wearable robots that assist users with functional limitations. Our logic platform will facilitate the emergence of future wearables powered by embedded fluidic logic that fully leverage the innate advantages of their textile construction.


Assuntos
Robótica , Indústria Têxtil , Têxteis , Dispositivos Eletrônicos Vestíveis , Biotecnologia , Lógica
9.
Eur Heart J ; 45(30): 2771-2781, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-38864173

RESUMO

BACKGROUND AND AIMS: In patients with de novo heart failure with reduced ejection fraction (HFrEF), improvement of left ventricular ejection fraction (LVEF) is expected to occur when started on guideline-recommended medical therapy. However, improvement may not be completed within 90 days. METHODS: Patients with HFrEF and LVEF ≤ 35% prescribed a wearable cardioverter-defibrillator between 2017 and 2022 from 68 sites were enrolled, starting with a registry phase for 3 months and followed by a study phase up to 1 year. The primary endpoints were LVEF improvement > 35% between Days 90 and 180 following guideline-recommended medical therapy initiation and the percentage of target dose reached at Days 90 and 180. RESULTS: A total of 598 patients with de novo HFrEF [59 years (interquartile range 51-68), 27% female] entered the study phase. During the first 180 days, a significant increase in dosage of beta-blockers, renin-angiotensin system inhibitors, and mineralocorticoid receptor antagonists was observed (P < .001). At Day 90, 46% [95% confidence interval (CI) 41%-50%] of study phase patients had LVEF improvement > 35%; 46% (95% CI 40%-52%) of those with persistently low LVEF at Day 90 had LVEF improvement > 35% by Day 180, increasing the total rate of improvement > 35% to 68% (95% CI 63%-72%). In 392 patients followed for 360 days, improvement > 35% was observed in 77% (95% CI 72%-81%) of the patients. Until Day 90, sustained ventricular tachyarrhythmias were observed in 24 wearable cardioverter-defibrillator carriers (1.8%). After 90 days, no sustained ventricular tachyarrhythmia occurred in wearable cardioverter-defibrillator carriers. CONCLUSIONS: Continuous optimization of guideline-recommended medical therapy for at least 180 days in HFrEF is associated with additional LVEF improvement > 35%, allowing for better decision-making regarding preventive implantable cardioverter-defibrillator therapy.


Assuntos
Insuficiência Cardíaca , Volume Sistólico , Humanos , Feminino , Masculino , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Pessoa de Meia-Idade , Idoso , Volume Sistólico/fisiologia , Antagonistas de Receptores de Mineralocorticoides/uso terapêutico , Função Ventricular Esquerda/fisiologia , Desfibriladores Implantáveis , Antagonistas Adrenérgicos beta/uso terapêutico , Duração da Terapia , Dispositivos Eletrônicos Vestíveis , Sistema de Registros
10.
Nano Lett ; 24(19): 5904-5912, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38700588

RESUMO

Stretchable electroluminescent devices represent an emerging optoelectronic technology for future wearables. However, their typical construction on sub-millimeter-thick elastomers has limited moisture permeability, leading to discomfort during long-term skin attachment. Although breathable textile displays may partially address this issue, they often have distinct visual appearances with discrete emissions from fibers or fiber junctions. This study introduces a convenient procedure to create stretchable, permeable displays with continuous luminous patterns. The design utilizes ultrathin nanocomposite devices embedded in a porous elastomeric microfoam to achieve high moisture permeability. These displays also exhibit excellent deformability, low-voltage operation, and excellent durability. Additionally, the device is decorated with fluorinated silica nanoparticles to achieve self-cleaning and washable capabilities. The practical implementation of these nanocomposite devices is demonstrated by creating an epidermal counter display that allows intimate integration with the human body. These developments provide an effective design of stretchable and breathable displays for comfortable wearing.

11.
BMC Bioinformatics ; 25(1): 243, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39026153

RESUMO

The growing number of portable consumer-grade electroencephalography (EEG) wearables offers potential to track brain activity and neurological disease in real-world environments. However, accompanying open software tools to standardize custom recordings and help guide independent operation by users is lacking. To address this gap, we developed HEROIC, an open-source software that allows participants to remotely collect advanced EEG data without the aid of an expert technician. The aim of HEROIC is to provide an open software platform that can be coupled with consumer grade wearables to record EEG data during customized neurocognitive tasks outside of traditional research environments. This article contains a description of HEROIC's implementation, how it can be used by researchers and a proof-of-concept demonstration highlighting the potential for HEROIC to be used as a scalable and low-cost EEG data collection tool. Specifically, we used HEROIC to guide healthy participants through standardized neurocognitive tasks and captured complex brain data including event-related potentials (ERPs) and powerband changes in participants' homes. Our results demonstrate HEROIC's capability to generate data precisely synchronized to presented stimuli, using a low-cost, remote protocol without reliance on an expert operator to administer sessions. Together, our software and its capabilities provide the first democratized and scalable platform for large-scale remote and longitudinal analysis of brain health and disease.


Assuntos
Encéfalo , Eletroencefalografia , Software , Dispositivos Eletrônicos Vestíveis , Eletroencefalografia/métodos , Humanos , Encéfalo/fisiologia , Potenciais Evocados/fisiologia , Masculino
12.
Med Res Rev ; 44(1): 23-65, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37246889

RESUMO

Cytokines are compounds that belong to a special class of signaling biomolecules that are responsible for several functions in the human body, being involved in cell growth, inflammatory, and neoplastic processes. Thus, they represent valuable biomarkers for diagnosing and drug therapy monitoring certain medical conditions. Because cytokines are secreted in the human body, they can be detected in both conventional samples, such as blood or urine, but also in samples less used in medical practice such as sweat or saliva. As the importance of cytokines was identified, various analytical methods for their determination in biological fluids were reported. The gold standard in cytokine detection is considered the enzyme-linked immunosorbent assay method and the most recent ones have been considered and compared in this study. It is known that the conventional methods are accompanied by a few disadvantages that new methods of analysis, especially electrochemical sensors, are trying to overcome. Electrochemical sensors proved to be suited for the elaboration of integrated, portable, and wearable sensing devices, which could also facilitate cytokines determination in medical practice.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Humanos , Suor/química , Saliva/química , Técnicas Biossensoriais/métodos
13.
Am J Epidemiol ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38960702

RESUMO

BACKGROUND: Studies examining the joint associations of lifestyle exposures can reveal novel synergistic and joint effects, but no study has examined the joint association of diet and physical activity (PA) with type 2 diabetes (T2D) and hypertension. The aim of this study is to examine the joint associations of PA and diet with incidence of type T2D and hypertension, as a combined outcome and separately in a large sample of UK adults. METHODS: This prospective cohort study included 144,288 UK Biobank participants aged 40-69. Moderate to vigorous PA (MVPA) was measured using the International Physical Activity Questionnaire and a wrist accelerometer. We categorised PA and diet indicators (diet quality score (DQS) and energy intake (EI)) based on tertiles and derived joint PA and diet variables. Outcome was major cardiometabolic disease incidence (combination of T2D and hypertension). RESULTS: A total of 14,003(7.1%) participants developed T2D, 28,075(19.2%) developed hypertension, and 30,529(21.2%) developed T2D or hypertension over a mean follow-up of 10.9(3.7) years. Participants with middle and high self-reported MVPA levels had lower risk of major cardiometabolic disease regardless of diet, e.g. among high DQS group, hazard ratios in middle and high MVPA group were 0.90 (95%CI:0.86-0.94), and 0.88(95%CI:0.84-0.92), respectively. Participants with jointly high device-measured MVPA and high DQS levels had lower major cardiometabolic disease risk (HR: 0.84, 95%CI:0.71-0.99). The equivalent joint device-measured MVPA and EI exposure analyses showed no clear pattern of associations with the outcomes. CONCLUSION: Higher PA is an important component in cardiometabolic disease prevention across all diet quality and total EI groups. The observed lack of association between diet health outcomes may stem from a lower DQS.

14.
Oncologist ; 29(4): e419-e430, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-37971410

RESUMO

INTRODUCTION: The aim of this systematic review was to summarize the current literature on wearable technologies in oncology patients for the purpose of prognostication, treatment monitoring, and rehabilitation planning. METHODS: A search was conducted in Medline ALL, Cochrane Central Register of Controlled Trials, Embase, Emcare, CINAHL, Scopus, and Web of Science, up until February 2022. Articles were included if they reported on consumer grade and/or non-commercial wearable devices in the setting of either prognostication, treatment monitoring or rehabilitation. RESULTS: We found 199 studies reporting on 18 513 patients suitable for inclusion. One hundred and eleven studies used wearable device data primarily for the purposes of rehabilitation, 68 for treatment monitoring, and 20 for prognostication. The most commonly-reported brands of wearable devices were ActiGraph (71 studies; 36%), Fitbit (37 studies; 19%), Garmin (13 studies; 7%), and ActivPAL (11 studies; 6%). Daily minutes of physical activity were measured in 121 studies (61%), and daily step counts were measured in 93 studies (47%). Adherence was reported in 86 studies, and ranged from 40% to 100%; of these, 63 (74%) reported adherence in excess of 80%. CONCLUSION: Wearable devices may provide valuable data for the purposes of treatment monitoring, prognostication, and rehabilitation. Future studies should investigate live-time monitoring of collected data, which may facilitate directed interventions.


Assuntos
Neoplasias , Dispositivos Eletrônicos Vestíveis , Humanos , Monitores de Aptidão Física , Exercício Físico , Neoplasias/terapia , Oncologia
15.
Hum Brain Mapp ; 45(4): e26620, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38436603

RESUMO

A primary goal of neuroscience is to understand the relationship between the brain and behavior. While magnetic resonance imaging (MRI) examines brain structure and function under controlled conditions, digital phenotyping via portable automatic devices (PAD) quantifies behavior in real-world settings. Combining these two technologies may bridge the gap between brain imaging, physiology, and real-time behavior, enhancing the generalizability of laboratory and clinical findings. However, the use of MRI and data from PADs outside the MRI scanner remains underexplored. Herein, we present a Preferred Reporting Items for Systematic Reviews and Meta-Analysis systematic literature review that identifies and analyzes the current state of research on the integration of brain MRI and PADs. PubMed and Scopus were automatically searched using keywords covering various MRI techniques and PADs. Abstracts were screened to only include articles that collected MRI brain data and PAD data outside the laboratory environment. Full-text screening was then conducted to ensure included articles combined quantitative data from MRI with data from PADs, yielding 94 selected papers for a total of N = 14,778 subjects. Results were reported as cross-frequency tables between brain imaging and behavior sampling methods and patterns were identified through network analysis. Furthermore, brain maps reported in the studies were synthesized according to the measurement modalities that were used. Results demonstrate the feasibility of integrating MRI and PADs across various study designs, patient and control populations, and age groups. The majority of published literature combines functional, T1-weighted, and diffusion weighted MRI with physical activity sensors, ecological momentary assessment via PADs, and sleep. The literature further highlights specific brain regions frequently correlated with distinct MRI-PAD combinations. These combinations enable in-depth studies on how physiology, brain function and behavior influence each other. Our review highlights the potential for constructing brain-behavior models that extend beyond the scanner and into real-world contexts.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Mapeamento Encefálico , Neuroimagem
16.
Biostatistics ; 24(3): 539-561, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-36519565

RESUMO

With the advent of continuous health monitoring with wearable devices, users now generate their unique streams of continuous data such as minute-level step counts or heartbeats. Summarizing these streams via scalar summaries often ignores the distributional nature of wearable data and almost unavoidably leads to the loss of critical information. We propose to capture the distributional nature of wearable data via user-specific quantile functions (QF) and use these QFs as predictors in scalar-on-quantile-function-regression (SOQFR). As an alternative approach, we also propose to represent QFs via user-specific L-moments, robust rank-based analogs of traditional moments, and use L-moments as predictors in SOQFR (SOQFR-L). These two approaches provide two mutually consistent interpretations: in terms of quantile levels by SOQFR and in terms of L-moments by SOQFR-L. We also demonstrate how to deal with multi-modal distributional data via Joint and Individual Variation Explained using L-moments. The proposed methods are illustrated in a study of association of digital gait biomarkers with cognitive function in Alzheimers disease. Our analysis shows that the proposed methods demonstrate higher predictive performance and attain much stronger associations with clinical cognitive scales compared to simple distributional summaries.


Assuntos
Doença de Alzheimer , Dispositivos Eletrônicos Vestíveis , Humanos , Doença de Alzheimer/diagnóstico , Marcha , Análise de Dados
17.
BMC Med ; 22(1): 36, 2024 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-38273340

RESUMO

BACKGROUND: Continuous assessment and remote monitoring of cognitive function in individuals with mild cognitive impairment (MCI) enables tracking therapeutic effects and modifying treatment to achieve better clinical outcomes. While standardized neuropsychological tests are inconvenient for this purpose, wearable sensor technology collecting physiological and behavioral data looks promising to provide proxy measures of cognitive function. The objective of this study was to evaluate the predictive ability of digital physiological features, based on sensor data from wrist-worn wearables, in determining neuropsychological test scores in individuals with MCI. METHODS: We used the dataset collected from a 10-week single-arm clinical trial in older adults (50-70 years old) diagnosed with amnestic MCI (N = 30) who received a digitally delivered multidomain therapeutic intervention. Cognitive performance was assessed before and after the intervention using the Neuropsychological Test Battery (NTB) from which composite scores were calculated (executive function, processing speed, immediate memory, delayed memory and global cognition). The Empatica E4, a wrist-wearable medical-grade device, was used to collect physiological data including blood volume pulse, electrodermal activity, and skin temperature. We processed sensors' data and extracted a range of physiological features. We used interpolated NTB scores for 10-day intervals to test predictability of scores over short periods and to leverage the maximum of wearable data available. In addition, we used individually centered data which represents deviations from personal baselines. Supervised machine learning was used to train models predicting NTB scores from digital physiological features and demographics. Performance was evaluated using "leave-one-subject-out" and "leave-one-interval-out" cross-validation. RESULTS: The final sample included 96 aggregated data intervals from 17 individuals. In total, 106 digital physiological features were extracted. We found that physiological features, especially measures of heart rate variability, correlated most strongly to the executive function compared to other cognitive composites. The model predicted the actual executive function scores with correlation r = 0.69 and intra-individual changes in executive function scores with r = 0.61. CONCLUSIONS: Our findings demonstrated that wearable-based physiological measures, primarily HRV, have potential to be used for the continuous assessments of cognitive function in individuals with MCI.


Assuntos
Disfunção Cognitiva , Dispositivos Eletrônicos Vestíveis , Idoso , Humanos , Pessoa de Meia-Idade , Cognição , Disfunção Cognitiva/diagnóstico , Aprendizado de Máquina , Testes Neuropsicológicos , Ensaios Clínicos como Assunto
18.
Small ; 20(9): e2305951, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37817356

RESUMO

Conductive microfibers play a significant role in the flexibility, stretchability, and conductivity of electronic skin (e-skin). Currently, the fabrication of conductive microfibers suffers from either time-consuming and complex operations or is limited in complex fabrication environments. Thus, it presents a one-step method to prepare conductive hydrogel microfibers based on microfluidics for the construction of ultrastretchable e-skin. The microfibers are achieved with conductive MXene cores and hydrogel shells, which are solidified with the covalent cross-linking between sodium alginate and calcium chloride, and mechanically enhanced by the complexation reaction of poly(vinyl alcohol) and sodium hydroxide. The microfiber conductivities are tailorable by adjusting the flow rate and concentration of core and shell fluids, which is essential to more practical applications in complex scenarios. More importantly, patterned e-skin based on conductive hydrogel microfibers can be constructed by combining microfluidics with 3D printing technology. Because of the great advantages in mechanical and electrical performance of the microfibers, the achieved e-skin shows impressive stretching and sensitivity, which also demonstrate attractive application values in motion monitoring and gesture recognition. These characteristics indicate that the ultrastretchable e-skin based on conductive hydrogel microfibers has great potential for applications in health monitoring, wearable devices, and smart medicine.


Assuntos
Hidrogéis , Pele , Condutividade Elétrica , Eletricidade , Alginatos
19.
Small ; 20(11): e2306769, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37932007

RESUMO

Fresh sweat contains a diverse range of physiological indicators that can effectively reflect changes in the body. However, existing wearable sweat detection systems face challenges in efficiently collecting and detecting fresh sweat in real-time. Additionally, they often lack the necessary deformation capabilities, resulting in discomfort for the wearer. Here, a fully elastic wearable electrochemical sweat detection system is developed that integrates a sweat-collecting microfluidic chip, a multi-parameter electrochemical sensor, a micro-heater, and a sweat detection elastic circuit board system. The unique tree-bionic structure of the microfluidic chip significantly enhances the efficiency of fresh sweat collection and discharge, enabling real-time detection by the electrochemical sensors. The sweat multi-parameter electrochemical sensor offers high-precision and high-sensitivity measurements of sodium ions, potassium ions, lactate, and glucose. The electronic system is built on an elastic circuit board that matches perfectly to wrinkled skin, ensuring improved wearing comfort and enabling multi-channel data sampling, processing, and wireless transmission. This state-of-the-art system represents a significant advancement in the field of elastic wearable sweat detection and holds promising potential for extending its capabilities to the detection of other sweat markers or various wearable applications.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Suor/química , Microfluídica , Árvores , Biônica , Íons/análise , Técnicas Biossensoriais/métodos
20.
Small ; : e2404771, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39109931

RESUMO

Triboelectric nanogenerators (TENG) are promising alternatives for clean energy harvesting. However, the material utilization in the development of TENG relies majorly on polymers derived from non-renewable resources. Therefore, minimizing the carbon footprint associated with such TENG development demands a shift toward usage of sustainable materials. This study pioneers using natural rubber (NR) as a sustainable alternative in TENG development. Infusing graphene in NR, its dielectric constant and tribonegativity are optimized, yielding a remarkable enhancement. The optimized sample exhibits a dielectric constant of 411 (at 103 Hz) and a contact potential difference (CPD) value of 1.85 V. In contrast, the pristine NR sample showed values of 6 and 3.06 V for the dielectric constant and CPD. Simulation and experimental studies fine-tune the TENG's performance, demonstrating excellent agreement between theoretical predictions and practical studies. Sensors developed via stencil printing technique possess a remarkably low layer thickness of 270 µm, and boast a power density of 420 mW m-2, a staggering 250% increase over conventional NR. Moreover, the material is pressure sensitive, enabling precise real-time human motion detection, including finger contact, finger bending, neck bending, and arm bending. This versatile sensor offers wireless monitoring, empowering healthcare monitoring based on the Internet of Things.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA