Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.413
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Nature ; 630(8016): 360-367, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38778109

RESUMO

Implanted biomaterials and devices face compromised functionality and efficacy in the long term owing to foreign body reactions and subsequent formation of fibrous capsules at the implant-tissue interfaces1-4. Here we demonstrate that an adhesive implant-tissue interface can mitigate fibrous capsule formation in diverse animal models, including rats, mice, humanized mice and pigs, by reducing the level of infiltration of inflammatory cells into the adhesive implant-tissue interface compared to the non-adhesive implant-tissue interface. Histological analysis shows that the adhesive implant-tissue interface does not form observable fibrous capsules on diverse organs, including the abdominal wall, colon, stomach, lung and heart, over 12 weeks in vivo. In vitro protein adsorption, multiplex Luminex assays, quantitative PCR, immunofluorescence analysis and RNA sequencing are additionally carried out to validate the hypothesis. We further demonstrate long-term bidirectional electrical communication enabled by implantable electrodes with an adhesive interface over 12 weeks in a rat model in vivo. These findings may offer a promising strategy for long-term anti-fibrotic implant-tissue interfaces.


Assuntos
Materiais Biocompatíveis , Fibrose , Reação a Corpo Estranho , Próteses e Implantes , Adesivos Teciduais , Animais , Feminino , Humanos , Masculino , Camundongos , Ratos , Parede Abdominal , Adsorção , Materiais Biocompatíveis/química , Colo , Eletrodos Implantados , Fibrose/patologia , Fibrose/prevenção & controle , Reação a Corpo Estranho/prevenção & controle , Reação a Corpo Estranho/patologia , Coração , Pulmão , Camundongos Endogâmicos C57BL , Especificidade de Órgãos , Reação em Cadeia da Polimerase , Ratos Sprague-Dawley , Estômago , Suínos , Fatores de Tempo , Adesivos Teciduais/química , Imunofluorescência , Reprodutibilidade dos Testes , Análise de Sequência de RNA
2.
Chem Rev ; 123(24): 14084-14118, 2023 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-37972301

RESUMO

Bioadhesives have emerged as transformative and versatile tools in healthcare, offering the ability to attach tissues with ease and minimal damage. These materials present numerous opportunities for tissue repair and biomedical device integration, creating a broad landscape of applications that have captivated clinical and scientific interest alike. However, fully unlocking their potential requires multifaceted design strategies involving optimal adhesion, suitable biological interactions, and efficient signal communication. In this Review, we delve into these pivotal aspects of bioadhesive design, highlight the latest advances in their biomedical applications, and identify potential opportunities that lie ahead for bioadhesives as multifunctional technology platforms.


Assuntos
Adesivos Teciduais , Materiais Biocompatíveis , Tecnologia
3.
Small ; 20(24): e2307628, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38191883

RESUMO

Injectable bioadhesives are attractive for managing gastric ulcers through minimally invasive procedures. However, the formidable challenge is to develop bioadhesives that exhibit high injectability, rapidly adhere to lesion tissues with fast gelation, provide reliable protection in the harsh gastric environment, and simultaneously ensure stringent standards of biocompatibility. Here, a natural bioadhesive with tunable cohesion is developed based on the facile and controllable gelation between silk fibroin and tannic acid. By incorporating a hydrogen bond disruptor (urea or guanidine hydrochloride), the inherent network within the bioadhesive is disturbed, inducing a transition to a fluidic state for smooth injection (injection force <5 N). Upon injection, the fluidic bioadhesive thoroughly wets tissues, while the rapid diffusion of the disruptor triggers instantaneous in situ gelation. This orchestrated process fosters the formed bioadhesive with durable wet tissue affinity and mechanical properties that harmonize with gastric tissues, thereby bestowing long-lasting protection for ulcer healing, as evidenced through in vitro and in vivo verification. Moreover, it can be conveniently stored (≥3 m) postdehydration. This work presents a promising strategy for designing highly injectable bioadhesives utilizing natural feedstocks, avoiding any safety risks associated with synthetic materials or nonphysiological gelation conditions, and offering the potential for minimally invasive application.


Assuntos
Ligação de Hidrogênio , Úlcera Gástrica , Animais , Úlcera Gástrica/tratamento farmacológico , Injeções , Adesivos Teciduais/química , Adesivos/química , Fibroínas/química , Taninos/química , Ratos Sprague-Dawley
4.
Nat Mater ; 22(2): 249-259, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36357687

RESUMO

While mechanical stimulation is known to regulate a wide range of biological processes at the cellular and tissue levels, its medical use for tissue regeneration and rehabilitation has been limited by the availability of suitable devices. Here we present a mechanically active gel-elastomer-nitinol tissue adhesive (MAGENTA) that generates and delivers muscle-contraction-mimicking stimulation to a target tissue with programmed strength and frequency. MAGENTA consists of a shape memory alloy spring that enables actuation up to 40% strain, and an adhesive that efficiently transmits the actuation to the underlying tissue. MAGENTA activates mechanosensing pathways involving yes-associated protein and myocardin-related transcription factor A, and increases the rate of muscle protein synthesis. Disuse muscles treated with MAGENTA exhibit greater size and weight, and generate higher forces compared to untreated muscles, demonstrating the prevention of atrophy. MAGENTA thus has promising applications in the treatment of muscle atrophy and regenerative medicine.


Assuntos
Músculo Esquelético , Adesivos Teciduais , Humanos , Músculo Esquelético/metabolismo , Músculo Esquelético/patologia , Adesivos Teciduais/metabolismo , Corantes de Rosanilina/metabolismo , Atrofia Muscular/prevenção & controle , Atrofia Muscular/metabolismo , Atrofia Muscular/patologia , Contração Muscular
5.
Biomacromolecules ; 25(2): 1084-1095, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38289249

RESUMO

Benzaldehyde-conjugated chitosan (CH-CBA) was synthesized by a coupling reaction between chitosan (CH) and carboxybenzaldehyde (CBA). The pH-sensitive self-cross-linking can be achieved through the Schiff base reaction. The degree of substitution (DS) of CH-CBA was controlled at 1.4-12.7% by optimizing the pH and reagent stoichiometry. The dynamic Schiff base linkages conferred strong shear-thinning and self-healing properties to the hydrogels. The viscosity of the 2 wt/v % CH-CBA hydrogel decreased from 5.3 × 107 mPa·s at a shear rate of 10-2 s-1 to 2.0 × 103 mPa·s at 102 s-1 at pH 7.4. The CH-CBA hydrogel exhibited excellent biocompatibility in vitro and in vivo. Moreover, the hydrogel adhered strongly to porcine small intestine, colon, and cecum samples, comparable to commercial fibrin glue, and exhibited effective in vivo tissue sealing in a mouse cecal ligation and puncture model, highlighting its potential as a biomaterial for application in tissue adhesives, tissue engineering scaffolds, etc.


Assuntos
Quitosana , Adesivos Teciduais , Camundongos , Animais , Suínos , Quitosana/química , Adesivos Teciduais/química , Benzaldeídos , Hidrogéis/química , Bases de Schiff/química , Camundongos Endogâmicos CBA
6.
Biomacromolecules ; 25(5): 3178-3189, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38632677

RESUMO

Bioadhesives with all-inclusive properties for simultaneous strong and robust adhesion, cohesion, tracking, drug delivery, self-sterilization, and nontoxicity are still farfetched. Herein, a carbon dot (CD) is made to infuse each of the above-desired aspects with gelatin, an inexpensive edible protein. The CD derived through controlled hydrothermal pyrolysis of dopamine and terephthaldehyde retained -NH2, -OH, -COOH, and, most importantly, -CHO functionality on the CD surface for efficient skin adhesion and cross-linking. Facile fabrication of CD-gelatin bioadhesive through covalent conjugation of -CHO of the CD with -NH2 of gelatin through Schiff base formation was accomplished. This imparts remarkable self-healing attributes as well as excellent adhesion and cohesion evident from physicomechanical analysis in a porcine skin model. Improved porosity of the bioadhesive allows loading hemin as a model drug whose disembarkment is tracked with intrinsic CD photoluminescence. In a significant achievement, antibiotic-free self-sterilization of bioadhesive is demonstrated through visible light (white LED, 23 W)-irradiated photosensitization of the CD to produce reactive oxygen species for annihilation of both Gram-positive and Gram-negative bacteria with exceptional efficacy (99.9%). Thus, a comprehensive CD-gelatin bioadhesive for superficial and localized wound management is reported as a promising step for the transformation of the bioadhesive domain through controlled nanotization for futuristic clinical translations.


Assuntos
Carbono , Sistemas de Liberação de Medicamentos , Gelatina , Gelatina/química , Carbono/química , Animais , Suínos , Sistemas de Liberação de Medicamentos/métodos , Esterilização/métodos , Adesivos Teciduais/química , Adesivos Teciduais/farmacologia , Pele/metabolismo , Pele/efeitos dos fármacos
7.
Biomacromolecules ; 25(7): 4510-4522, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38877976

RESUMO

Stimuli-responsive adhesives with on-demand adhesion capabilities are highly advantageous for facilitating wound healing. However, the triggering conditions of stimuli-responsive adhesives are cumbersome, even though some of them are detrimental to the adhesive and adjacent natural tissues. Herein, a novel stimuli-responsive adhesive called shear-stiffening adhesive (SSA) has been created by constructing a poly(diborosiloxane)-based silicone network for the first time, and SSA exhibits a rate-responsive adhesion behavior. Furthermore, we introduced bactericidal factors (PVP-I) into SSA and applied it as a wound dressing to promote the healing of infected wounds. Impressively, the wound dressing not only has excellent biocompatibility and long-term antibacterial properties but also performs well in accelerating wound healing. Therefore, this study provides a new strategy for the synthesis of intelligent adhesives with force rate response, which simplifies the triggering conditions by the force rate. Thus, SSA has great potential to be applied in wound management as an intelligent bioadhesive with on-demand adhesion performance.


Assuntos
Bandagens , Silicones , Cicatrização , Cicatrização/efeitos dos fármacos , Animais , Silicones/química , Adesivos/química , Adesivos/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Camundongos , Adesivos Teciduais/química , Adesivos Teciduais/farmacologia , Humanos , Staphylococcus aureus/efeitos dos fármacos
8.
Soft Matter ; 20(26): 5122-5133, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38894656

RESUMO

Solid particles placed at the interface between hydrogels and biological tissues can create an adhesive joint through the adsorption of macromolecules onto their surfaces. Here, we investigated how this adhesion by particle bridging depends on the wetting of tissue surfaces and on the heterogeneities in tissue composition. Ex vivo peeling experiments were performed using poly(ethylene glycol) films coated with aggregates of silica nanoparticles deposited on the internal tissues of porcine liver. We show that the adhesion produced by particle bridging is altered by the presence of fluid wetting the tissue-hydrogel interface. For both uncoated and coated films, a transition from lubricated to adhesive contact was observed when all the interfacial fluid was drained. The presence of a silica nanoparticle coating shifted the transition towards more hydrated conditions and significantly enhanced adhesion in the adhesive regime. After 5 min of contact, the adhesion energy achieved on liver parenchyma with the coated films (7.7 ± 1.9 J m-2) was more than twice that of the uncoated films (3.2 ± 0.3 J m-2) or with a surgical cyanoacrylate glue (2.9 ± 1.9 J m-2). Microscopic observations during and after peeling revealed different detachment processes through either particle detachment or cohesive fracture in the tissue. These mechanisms could be directly related to the microanatomy of the liver parenchyma. The effects of both interfacial wetting and tissue composition on adhesion may provide guidelines to tailor the design of tissue adhesives using particle bridging.


Assuntos
Hidrogéis , Fígado , Dióxido de Silício , Molhabilidade , Animais , Suínos , Hidrogéis/química , Dióxido de Silício/química , Nanopartículas/química , Polietilenoglicóis/química , Adesivos Teciduais/química
9.
J Surg Res ; 295: 783-790, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38157730

RESUMO

INTRODUCTION: Our objective was to perform a feasibility study using real-world data from a learning health system (LHS) to describe current practice patterns of wound closure and explore differences in outcomes associated with the use of tissue adhesives and other methods of wound closure in the pediatric surgical population to inform a potentially large study. METHODS: A multi-institutional cross-sectional study was performed of a random sample of patients <18 y-old who underwent laparoscopic appendectomy, open or laparoscopic inguinal hernia repair, umbilical hernia repair, or repair of traumatic laceration from January 1, 2019, to December 31, 2019. Sociodemographic and operative characteristics were obtained from 6 PEDSnet (a national pediatric LHS) children's hospitals and OneFlorida Clinical Research Consortium (a PCORnet collaboration across 14 academic health systems). Additional clinical data elements were collected via chart review. RESULTS: Of the 692 patients included, 182 (26.3%) had appendectomies, 155 (22.4%) inguinal hernia repairs, 163 (23.6%) umbilical hernia repairs, and 192 (27.8%) traumatic lacerations. Of the 500 surgical incisions, sutures with tissue adhesives were the most frequently used (n = 211, 42.2%), followed by sutures with adhesive strips (n = 176, 35.2%), and sutures only (n = 72, 14.4%). Most traumatic lacerations were repaired with sutures only (n = 127, 64.5%). The overall wound-related complication rate was 3.0% and resumption of normal activities was recommended at a median of 14 d (interquartile ranges 14-14). CONCLUSIONS: The LHS represents an efficient tool to identify cohorts of pediatric surgical patients to perform comparative effectiveness research using real-world data to support medical and surgical products/devices in children.


Assuntos
Hérnia Inguinal , Hérnia Umbilical , Lacerações , Laparoscopia , Sistema de Aprendizagem em Saúde , Adesivos Teciduais , Humanos , Criança , Adesivos Teciduais/uso terapêutico , Lacerações/epidemiologia , Lacerações/cirurgia , Hérnia Inguinal/cirurgia , Estudos Transversais , Hérnia Umbilical/cirurgia , Suturas , Resultado do Tratamento , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Herniorrafia/efeitos adversos , Herniorrafia/métodos
10.
Cochrane Database Syst Rev ; 5: CD013421, 2024 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-38695613

RESUMO

BACKGROUND: During vascular interventions, connections that link arteries, veins, or synthetic grafts, which are known as an 'anastomosis', may be necessary. Vascular anastomoses can bleed from the needle holes that result from the creation of the anastomoses. Various surgical options are available for achieving hemostasis, or the stopping of bleeding, including the application of sealants directly onto the bleeding vessels or tissues. Sealants are designed for use in vascular surgery as adjuncts when conventional interventions are ineffective and are applied directly by the surgeon to seal bleeding anastomoses. Despite the availability of several different types of sealants, the evidence for the clinical efficacy of these hemostatic adjuncts has not been definitively established in vascular surgery patients. OBJECTIVES: To evaluate the benefits and harms of sealants as adjuncts for achieving anastomotic site hemostasis in patients undergoing vascular surgery. SEARCH METHODS: The Cochrane Vascular Information Specialist conducted systematic searches of the following databases: the Cochrane Vascular Specialised Register via the Cochrane Register of Studies; the Cochrane Central Register of Controlled Trials (CENTRAL); MEDLINE via Ovid; Embase via Ovid ; and CINAHL via EBSCO. We also searched ClinicalTrials.gov and the WHO International Clinical Trials Registry Platform for clinical trials. Reference lists of included trials and relevant reviews were also searched. The latest search date was 6 March 2023. SELECTION CRITERIA: We included randomized controlled trials that compared fibrin or synthetic sealant use with alternative interventions (e.g. manual compression, reversal of anticoagulation) for achieving anastomotic-site hemostasis in vascular surgery procedures. We included participants who underwent the creation of an anastomosis during vascular surgery. We excluded non-vascular surgery patients. DATA COLLECTION AND ANALYSIS: We have used standard Cochrane methods. Our primary outcomes were time to hemostasis, failure of hemostatic intervention, and intraoperative blood loss. Our secondary outcomes were operating time, death from bleeding complications up to 30 days, postoperative bleeding up to 30 days, unplanned return to the operating room for bleeding complications management up to 30 days, quality of life, and adverse events. We used GRADE to assess the certainty of evidence for each outcome. MAIN RESULTS: We found 24 randomized controlled trials that included a total of 2376 participants who met the inclusion criteria. All trials compared sealant use with standard care controls, including oxidized cellulose, gelatin sponge, and manual compression. All trials were at high risk of performance bias, detection bias, and other sources of bias. We downgraded the certainty of evidence for risk of bias concerns, inconsistency, imprecision and possible publication bias. Combining data on time to hemostasis showed that sealant use may reduce the mean time to hemostasis compared to control (mean difference (MD) -230.09 seconds, 95% confidence interval (CI) -329.24 to -130.94; P < 0.00001; 7 studies, 498 participants; low-certainty evidence). Combining data on failure of hemostatic intervention showed that sealant use may reduce the rate of failure compared to control, but the evidence is very uncertain (risk ratio (RR) 0.46, 95% CI 0.35 to 0.61; P < 0.00001; 17 studies, 2120 participants; very low-certainty evidence). We did not detect any clear differences between the sealant and control groups for intraoperative blood loss (MD -32.69 mL, 95% CI -96.21 to 30.83; P = 0.31; 3 studies, 266 participants; low-certainty evidence); operating time (MD -18.72 minutes, 95% CI -40.18 to 2.73; P = 0.09; 4 studies, 436 participants; low-certainty evidence); postoperative bleeding (RR 0.78, 95% CI 0.59 to 1.04; P = 0.09; 9 studies, 1216 participants; low-certainty evidence), or unplanned return to the operating room (RR 0.27, 95% CI 0.04 to 1.69; P = 0.16; 8 studies, 721 participants; low-certainty evidence). No studies reported death from bleeding or quality of life outcomes. AUTHORS' CONCLUSIONS: Based on meta-analysis of 24 trials with 2376 participants, our review demonstrated that sealant use for achieving anastomotic hemostasis in vascular surgery patients may result in reduced time to hemostasis, and may reduce rates of hemostatic intervention failure, although the evidence is very uncertain, when compared to standard controls. Our analysis showed there may be no differences in intraoperative blood loss, operating time, postoperative bleeding up to 30 days, and unplanned return to the operating room for bleeding complications up to 30 days. Deaths and quality of life could not be analyzed. Limitations include the risk of bias in all studies. Our review has demonstrated that using sealants may reduce the time required to achieve hemostasis and the rate of hemostatic failure. However, a significant risk of bias was identified in the included studies, and future trials are needed to provide unbiased data and address other considerations such as cost-effectiveness and adverse events with sealant use.


Assuntos
Anastomose Cirúrgica , Hemostasia Cirúrgica , Ensaios Clínicos Controlados Aleatórios como Assunto , Procedimentos Cirúrgicos Vasculares , Humanos , Hemostasia Cirúrgica/métodos , Hemostáticos/uso terapêutico , Adesivo Tecidual de Fibrina/uso terapêutico , Perda Sanguínea Cirúrgica/prevenção & controle , Adesivos Teciduais/uso terapêutico
11.
Ann Vasc Surg ; 103: 89-98, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38395347

RESUMO

BACKGROUND: To compare radiofrequency ablation (RFA) and cyanoacrylate closure (CAC) for large-diameter great saphenous vein (GSV) insufficiency between diameters of 12 and 16 mm. METHODS: This study is a single-center retrospective study. Subjects who underwent endovenous treatment with RFA (Group A) or CAC (Group B) for GSV insufficiency between June 2015 and June 2021 who were followed up for at least 2 years were included in the study. Subjects who had a 12-mm to 16-mm target vessel diameter and subjects with grade 3 and grade 4 reflux were included. Subjects' demographic data (age, sex), body mass indices, clinical, etiological, anatomic, pathophysiologic classification, GSV diameter, reflux grade, target vessel length, preoperative venous clinical severity score (VCSS), procedural time, postoperative first-day pain scores, postoperative 14th-day patient satisfaction scale, and postoperative complications were noted. In follow-up, subjects were evaluated with duplex ultrasonography and VCSS at 1, 6, 12, and 24 months. RESULTS: In total, 142 subjects were included (n = 71 for both groups). The mean GSV diameter was 13.21 ± 1.00 for Group A and 13.51 ± 0.97 for Group B. The groups did not differ in terms of age, sex, body mass index, clinical, etiological, anatomic, pathophysiologic classification, GSV diameter, reflux grade, target GSV length, preoperative VCSS, complications, postoperative 24-hr pain status or postoperative 14-day patient satisfaction scale (P > 0.05 for all comparisons). The procedure time was significantly shorter in Group B (34.68 ± 4.22 min for Group A vs. 22.59 ± 4.5 min for Group B, P = 0.001). In the 1-month and 6-month Duplex ultrasonography of the subjects, partial closure and patency rates in Group B were significantly higher than those in Group A (P = 0.003 and P = 0.025, respectively). At the 12-month and 24-month evaluation, closure rates did not show a statistically significant difference between the groups (P = 0.056 and P = 0.090, respectively). Preoperative and 1-month VCSS measurements did not show a statistically significant difference between groups (P > 0.05 for all comparisons). The 6-month, 12-month, and 24-month VCSS measurements of Group A were significantly higher than those in Group B. (P = 0.043, P = 0.009 and P = 0.002, respectively). CONCLUSIONS: Both RFA and CAC were found to be effective in the treatment of large-diameter GSV incompetency. The complication rates were similar between the 2 techniques. CAC had a shorter procedure time. Although the closure rates in the early postoperative period were better in the RFA group, long-term follow-up demonstrated similar patency rates. The functional results in the long-term follow-up were better in the RFA group.


Assuntos
Cianoacrilatos , Veia Safena , Insuficiência Venosa , Humanos , Veia Safena/diagnóstico por imagem , Veia Safena/fisiopatologia , Veia Safena/cirurgia , Estudos Retrospectivos , Feminino , Masculino , Insuficiência Venosa/diagnóstico por imagem , Insuficiência Venosa/cirurgia , Insuficiência Venosa/fisiopatologia , Insuficiência Venosa/terapia , Pessoa de Meia-Idade , Resultado do Tratamento , Cianoacrilatos/efeitos adversos , Cianoacrilatos/administração & dosagem , Fatores de Tempo , Adulto , Idoso , Ablação por Radiofrequência/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Adesivos Teciduais/uso terapêutico , Adesivos Teciduais/efeitos adversos
12.
J Drugs Dermatol ; 23(5): 380, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38709685

RESUMO

Wound repair of the pretibial and forearm regions presents a challenge during dermatologic surgery as these areas are under significant tension and exhibit increased skin fragility. Various methodologies have been proposed for the closure and repair of such wounds, however, the use of the bilayered suture technique may be simpler and more effective than other techniques such as the pinch stitch, pully stitch, slip-knot stitch, pulley set-back dermal suture, horizontal mattress suture, pully stitch, and tandem pulley stitch. Our objective was to describe a novel method for the repair of pretibial and forearm wounds following Mohs micrographic surgery utilizing bilayered closure followed by tissue adhesive application.  J Drugs Dermatol. 2024;23(5):380.     doi:10.36849/JDD.7139  .


Assuntos
Antebraço , Cirurgia de Mohs , Neoplasias Cutâneas , Técnicas de Sutura , Cicatrização , Humanos , Cirurgia de Mohs/efeitos adversos , Cirurgia de Mohs/métodos , Antebraço/cirurgia , Neoplasias Cutâneas/cirurgia , Adesivos Teciduais , Perna (Membro)/cirurgia , Masculino , Feminino
13.
Proc Natl Acad Sci U S A ; 118(28)2021 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-34264848

RESUMO

During operations, surgical mesh is commonly fixed on tissues through fasteners such as sutures and staples. Attributes of surgical mesh include biocompatibility, flexibility, strength, and permeability, but sutures and staples may cause stress concentration and tissue damage. Here, we show that the functions of surgical mesh can be significantly broadened by developing a family of materials called hydrogel-mesh composites (HMCs). The HMCs retain all the attributes of surgical mesh and add one more: adhesion to tissues. We fabricate an HMC by soaking a surgical mesh with a precursor, and upon cure, the precursor forms a polymer network of a hydrogel, in macrotopological entanglement with the fibers of the surgical mesh. In a surgery, the HMC is pressed onto a tissue, and the polymers in the hydrogel form covalent bonds with the tissue. To demonstrate the concept, we use a poly(N-isopropylacrylamide) (PNIPAAm)/chitosan hydrogel and a polyethylene terephthalate (PET) surgical mesh. In the presence a bioconjugation agent, the chitosan and the tissue form covalent bonds, and the adhesion energy reaches above 100 J⋅m-2 At body temperature, PNIPAAm becomes hydrophobic, so that the hydrogel does not swell and the adhesion is stable. Compared with sutured surgical mesh, the HMC distributes force over a large area. In vitro experiments are conducted to study the application of HMCs to wound closure, especially on tissues under high mechanical stress. The performance of HMCs on dynamic living tissues is further investigated in the surgery of a sheep.


Assuntos
Hidrogéis/farmacologia , Telas Cirúrgicas , Cicatrização , Animais , Artérias Carótidas/efeitos dos fármacos , Artérias Carótidas/patologia , Feminino , Fígado/efeitos dos fármacos , Fígado/patologia , Ovinos , Adesivos Teciduais/farmacologia , Cicatrização/efeitos dos fármacos
14.
J Mater Sci Mater Med ; 35(1): 15, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38456966

RESUMO

Accidental events or surgical procedures usually lead to tissue injury. Fibrin sealants have proven to optimize the healing process but have some drawbacks due to their allogeneic nature. Autologous fibrin sealants present several advantages. The aim of this study is to evaluate the performance of a new autologous fibrin sealant based on Endoret®PRGF® technology (E-sealant). One of the most widely used commercial fibrin sealants (Tisseel®) was included as comparative Control. E-sealant´s hematological and biological properties were characterized. The coagulation kinetics and the microstructure were compared. Their rheological profile and biomechanical behavior were also recorded. Finally, the swelling/shrinkage capacity and the enzymatic degradation of adhesives were determined. E-sealant presented a moderate platelet concentration and physiological levels of fibrinogen and thrombin. It clotted 30 s after activation. The microstructure of E-sealant showed a homogeneous fibrillar scaffold with numerous and scattered platelet aggregates. In contrast, Control presented absence of blood cells and amorphous protein deposits. Although in different order of magnitude, both adhesives had similar rheological profiles and viscoelasticity. Control showed a higher hardness but both adhesives presented a pseudoplastic hydrogel nature with a shear thinning behavior. Regarding their adhesiveness, E-sealant presented a higher tensile strength before cohesive failure but their elastic stretching capacity and maximum elongation was similar. While E-sealant presented a significant shrinkage process, Control showed a slight swelling over time. In addition, E-sealant presented a high enzymatic resorption rate, while Control showed to withstand the biodegradation process in a significant way. E-sealant presents optimal biochemical and biomechanical properties suitable for its use as a fibrin sealant with regenerative purposes.


Assuntos
Hemostáticos , Adesivos Teciduais , Adesivo Tecidual de Fibrina/química , Adesivos Teciduais/química , Medicina Regenerativa , Hemostáticos/química , Cicatrização
15.
BMC Surg ; 24(1): 122, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658932

RESUMO

Various studies have focused on the application of fibrin sealants (FS) in thyroid surgery. Utilizing a meta-analysis, this systematic review analyzed the findings of recent randomized controlled trials on the safety and efficacy of FS in patients who underwent thyroidectomy. The Cochrane Library, Web of Science, Embase, PubMed, and Medline databases were searched for relevant studies, without any language restrictions. Seven randomized controlled trials were included in the originally identified 69 studies. Overall, 652 patients received FS during thyroid surgery; their outcomes were compared with those of conventionally treated patients. The primary outcomes were total volume of wound drainage, length of hospitalization, and operative time. Significant differences were observed in the total volume of wound drainage (mean deviation (MD): -29.75, 95% confidence interval (CI): -55.39 to -4.11, P = 0.02), length of hospitalization (MD: -0.84, 95% CI: -1.02 to -0.66, P < 0.00001), and surgery duration (MD: -7.60, 95% CI: -14.75 to -0.45, P = 0.04). Secondary outcomes were seroma and hypoparathyroidism development. The risk of hypoparathyroidism did not differ between the FS and conventional groups (I = 0%, relative risk = 1.31, P = 0.38). Analysis of "seroma formation that required invasive treatment" indicated that FS showed some benefit (I2 = 8%, relative risk 0.44, P = 0.15). Heterogeneity among the different trials limited their conclusions. The meta-analysis showed that although FS use did not significantly reduce seroma or hypoparathyroidism incidence in patients after thyroidectomy, it significantly reduced the total drainage volume, length of hospitalization, and duration of surgery.


Assuntos
Adesivo Tecidual de Fibrina , Tireoidectomia , Humanos , Tireoidectomia/efeitos adversos , Tireoidectomia/métodos , Adesivo Tecidual de Fibrina/uso terapêutico , Resultado do Tratamento , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Tempo de Internação/estatística & dados numéricos , Ensaios Clínicos Controlados Aleatórios como Assunto , Duração da Cirurgia , Adesivos Teciduais/uso terapêutico
16.
Clin Oral Investig ; 28(6): 347, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38819478

RESUMO

OBJECTIVE: To overview the literature to answer the following question: "What is the performance of different therapies on wound healing and postoperative discomfort after palatal ASTG removal?" METHODS: SRs that evaluated the wound healing (WH), postoperative pain, bleeding, and analgesic consumption of patients submitted to de-epithelialized/free gingival grafts (FGG) or subepithelial connective tissue grafts (SCTG) removed from the palate were included. The searches were conducted on six white and two gray databases up to December 2023. Methodological quality was evaluated through AMSTAR 2. The synthesis of results was described as a narrative analysis. RESULTS: Ten SRs (involving 25 randomized clinical trials) related to low-level laser therapy (LLLT) (3), platelet-rich fibrin (PRF) (4), cyanoacrylate tissue adhesives (CTA) (2), and ozone therapy (OT) (1) were included in this overview. All techniques demonstrated improvements in WH. LLT, PRF, and CTA reduced pain and analgesic consumption. PRF and CTA reduced bleeding. Regarding methodological quality, the SRs were classified as critically low (2), low (5), moderate (2), or high quality (1). CONCLUSIONS: In SRs related to LLLT, PRF, CTA, and OT, the use of different therapies after palatal ASTG removal improved WH and postoperative discomfort. Due to the studies' low methodological quality and high heterogeneity, data should be interpreted with caution. CLINICAL RELEVANCE: The present overview compiles the evidence of SRs related to different therapies for WH and patients' postoperative experience and reveals that different treatments can significantly improve the clinical outcomes of patients who require ASTG removal for periodontal or peri-implant surgeries. REGISTRATION: PROSPERO registration number: CRD42022301257.


Assuntos
Dor Pós-Operatória , Fibrina Rica em Plaquetas , Cicatrização , Humanos , Palato/cirurgia , Gengiva/transplante , Terapia com Luz de Baixa Intensidade/métodos , Adesivos Teciduais/uso terapêutico , Tecido Conjuntivo/transplante , Revisões Sistemáticas como Assunto
17.
Clin Oral Investig ; 28(3): 180, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38418796

RESUMO

OBJECTIVE: Cyanoacrylate tissue adhesive has been presented as an alternative to sutures and several studies have compared them. The objective of this meta-analysis was to evaluate the effect of cyanoacrylate tissue adhesive on postoperative pain and swelling, following mandibular third molar surgery. MATERIALS AND METHODS: Database search was conducted in MEDLINE/PubMed and Scopus, along with extensive search in the grey literature, including randomized and non-randomized clinical trials that applied cyanoacrylate adhesive for closing mandibular third molar surgical sites and compared it with silk sutures, assessing postoperative pain and swelling. The search ended on September 22, 2023. RESULTS: Of 886 identified articles, six were included and meta-analyzed. Applying cyanoacrylate demonstrated a reduction in the overall postoperative pain (SMD = -0.57, 95% CI -1.00 to -0.15, p = 0.009). A similar outcome was noted when pain was evaluated on the first and last postoperative days, based on controlled clinical trials (SMD = -0.47, 95% CI -0.92 to -0.03, p = 0.04), and randomized trials (SMD = -0.97, 95% CI -1.31 to -0.62, p < 0.00001). Patients/sides received cyanoacrylate showed a decrease in postoperative swelling (SMD = -0.26, 95% CI -0.51 to -0.01, p = 0.04). Following the GRADE rating system, the quality of evidence on pain and swelling was judged as moderate and low, respectively. CONCLUSIONS: The use of cyanoacrylate adhesive may offer benefit in reducing postoperative pain and swelling following mandibular third molar surgery. Nevertheless, this should be further investigated, considering the low number of included reports. CLINICAL RELEVANCE: The current results could help clinicians who perform this procedure to manage postoperative pain and swelling more effectively.


Assuntos
Adesivos Teciduais , Dente Impactado , Humanos , Adesivos Teciduais/uso terapêutico , Cianoacrilatos/uso terapêutico , Dente Serotino/cirurgia , Dente Impactado/cirurgia , Extração Dentária/métodos , Trismo/tratamento farmacológico , Dor Pós-Operatória/prevenção & controle , Dor Pós-Operatória/tratamento farmacológico , Suturas , Edema/prevenção & controle , Edema/tratamento farmacológico , Seda
18.
J Pediatr Orthop ; 44(2): e203-e208, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37820062

RESUMO

BACKGROUND: Dermabond (Dermabond; Ethicon, Sommerville, NJ), is a skin adhesive commonly utilized in pediatric orthopedic surgery for postoperative wound care. Few studies have examined outcomes of Dermabond exposure in children. The purpose of this study is to estimate the incidence of skin reactions following Dermabond exposure in pediatric orthopedic surgery and investigate potential risk factors associated with Dermabond sensitivity. METHODS: This was a retrospective study of a level-one pediatric trauma center. All orthopaedic surgeries in 2019 were screened for Dermabond application. Three surgeons with the highest rates of Dermabond application defined our cohort. Out of 2990 surgeries in 2019, the 3 surgeons performed 234 surgeries with Dermabond. Postoperative reactions and repeat Dermabond exposures were collected for these 234 patients. Subjects with known allergies to Dermabond were excluded. Reactions were defined. as discoloration, irritation, and wound dehiscence. Significant differences between patients with repeat Dermabond exposures and those without were determined using χ 2 analysis. Associations between patient characteristics and sensitivity were determined using logistic regression analysis. P values less than 0.05 were considered significant. RESULTS: In all, 234 patients were included for analysis. The mean age at surgery was 12.5 years (SD 6.1), and 39% (92/234) of the cohort was male. Thirty-two patients (14%) experienced skin reactions during the study period (95% CI=7%-19%). Reactions most frequently included. erythema (10/32; 31%) and itchiness (10/32; 31%). Reactions were most frequently treated with oral antibiotics, Benadryl, or a dressing change. Of 144 patients with 1 Dermabond exposure, 17 (12%) experienced reactions (95% CI=7%-18%). Of 128 patients experiencing a repeat Dermabond exposure, 27 (21%) experienced reactions (95% CI=19%-34%, P =0.03). Age, surgical procedure, and surgical location were not, associated with a variable rate of sensitivity. CONCLUSIONS: Sensitivity to Dermabond after pediatric orthopedic surgery occurred at a higher rate than seen in adults, and patients with multiple Dermabond exposures experienced significantly higher sensitivity than patients with a single exposure. Increased awareness of this potential complication is needed to help inform decisions regarding Dermabond's application in pediatric orthopedics.


Assuntos
Procedimentos Ortopédicos , Adesivos Teciduais , Adulto , Humanos , Masculino , Criança , Adesivos Teciduais/efeitos adversos , Estudos Retrospectivos , Incidência , Procedimentos Ortopédicos/efeitos adversos
19.
Aesthetic Plast Surg ; 48(12): 2224-2230, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38456891

RESUMO

The following questions guided the study: Can the use of fibrin glue in drainless rhytidoplasty reduce hematoma prevalence, seroma prevalence increase patient satisfaction or decrease the length of hospital in the adult population compared with standard treatment? The following inclusion and exclusion criteria apply: The procedure performed was rhytidoplasty for both groups. Participants were limited to adults who did not have any other procedure performed during the study. The intervention consisted of the use of fibrin glue without drains compared to the control group, in which drains and/or pressure dressing were applied. Databases: clinicaltrials.gov, MEDLINE, COCHRANE, mRCT, PubMed, Google Scholar, Scopus, Embase, VHL, GHL were searched on 03/25/2023 by 2 different investigators. The Cochrane Risk of Bias Tool 2.0 was used. Five studies were included with a total number of 1277 participants (2554 face sides). The cumulative hematoma rate was OR 0.47 (95% CI 0.26-0.84) in favor of using fibrin glue. Insufficient data were available to assess seroma rate, patient satisfaction, and length of hospital stay. The risk of study bias was judged to be low and moderate. The certainty for the use of fibrin sealant versus drainage is high and the importance of outcomes is rated as important in the GRADEpro GDT tool. Fibrin glue use is more beneficial comparing to drainage in patients undergoing rhytidectomy in terms of hematoma prevalence. This study was registered in PROSPERO (CRD42023421475).Level of Evidence I This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Adesivo Tecidual de Fibrina , Ritidoplastia , Humanos , Ritidoplastia/métodos , Ritidoplastia/efeitos adversos , Adesivo Tecidual de Fibrina/uso terapêutico , Satisfação do Paciente/estatística & dados numéricos , Feminino , Seroma/prevenção & controle , Seroma/epidemiologia , Seroma/etiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Hematoma/etiologia , Hematoma/epidemiologia , Hematoma/prevenção & controle , Masculino , Adesivos Teciduais/uso terapêutico , Estética , Drenagem/métodos , Resultado do Tratamento , Tempo de Internação/estatística & dados numéricos
20.
Int J Mol Sci ; 25(10)2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38791286

RESUMO

In clinical practice, tissue adhesives have emerged as an alternative tool for wound treatments due to their advantages in ease of use, rapid application, less pain, and minimal tissue damage. Since most tissue adhesives are designed for internal use or wound treatments, the biodegradation of adhesives is important. To endow tissue adhesives with biodegradability, in the past few decades, various biodegradable polymers, either natural polymers (such as chitosan, hyaluronic acid, gelatin, chondroitin sulfate, starch, sodium alginate, glucans, pectin, functional proteins, and peptides) or synthetic polymers (such as poly(lactic acid), polyurethanes, polycaprolactone, and poly(lactic-co-glycolic acid)), have been utilized to develop novel biodegradable tissue adhesives. Incorporated biodegradable polymers are degraded in vivo with time under specific conditions, leading to the destruction of the structure and the further degradation of tissue adhesives. In this review, we first summarize the strategies of utilizing biodegradable polymers to develop tissue adhesives. Furthermore, we provide a symmetric overview of the biodegradable polymers used for tissue adhesives, with a specific focus on the degradability and applications of these tissue adhesives. Additionally, the challenges and perspectives of biodegradable polymer-based tissue adhesives are discussed. We expect that this review can provide new inspirations for the design of novel biodegradable tissue adhesives for biomedical applications.


Assuntos
Materiais Biocompatíveis , Adesivos Teciduais , Adesivos Teciduais/química , Humanos , Animais , Materiais Biocompatíveis/química , Polímeros/química , Plásticos Biodegradáveis/química , Quitosana/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA