Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.879
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Surg ; 79(6): 1315-1325, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38382641

RESUMO

OBJECTIVE: The aim of this study was to investigate the mid-term results of stented-assisted balloon-induced intimal disruption and relamination (STABILISE) in patients with aortic dissection with the implementation of volumetric analysis. METHODS: This was a single-center retrospective analysis of prospectively collected data. From May 2017 to September 2022, 42 patients underwent STABILISE for acute complicated or subacute high-risk aortic dissection. STABILISE was completed with distal extended endovascular aortic repair in 24 patients. A computed tomography scan was performed at baseline, before hospital discharge, and at 1, 3, and 5 years. Perfused total aortic, true lumen, and false lumen volumes were assessed for thoracic, visceral, and aorto-iliac segment. The ratio between false lumen and total volume was named perfusion dissection index (PDI). Complete remodeling was defined as PDI = 0, and positive remodeling as PDI ≤0.1. RESULTS: Technical success was 97.6%. No 30-day deaths, spinal cord injuries, or retrograde dissections were observed. Mean follow-up was 44 ± 19.4 months. Thoracic diameter was lower at last available computed tomography scan (36.7 vs 33.0 mm; P = .01). Aortic growth >5 mm was observed in 9.5% of the patients. Thoracic and visceral aortic complete remodeling were 92.8% and 83.3%, respectively, with no difference between acute and subacute group. Distal extended endovascular aortic repair significantly increased complete remodeling in the aorto-iliac segment, compared with STABILISE alone (69.6% vs 21.4%; P < .001). Freedom from vascular reinterventions at 3 years was 83.1% (95% confidence interval, 71.5%-96.6%). Total PDI ≤0.1 at first postoperative control was a predictor of vascular reinterventions (P < .0001). CONCLUSIONS: STABILISE is a safe and feasible technique associated with high mid-term rates of complete remodeling in the thoracic and visceral aorta. Volumetric analysis allows the quantification of aortic remodeling and represents a predictor of aortic reinterventions.


Assuntos
Dissecção Aórtica , Stents , Humanos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Masculino , Feminino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Fatores de Tempo , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Remodelação Vascular , Angiografia por Tomografia Computadorizada , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Valor Preditivo dos Testes , Reoperação , Aortografia , Fatores de Risco
2.
Catheter Cardiovasc Interv ; 103(6): 972-981, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38606477

RESUMO

BACKGROUND: Ethylene diamine tetra-acetic acid (EDTA) is a chelating agent used to dissolve calcium deposits but evidence in decalcifying atherosclerotic lesions is limited. AIMS: We assessed the feasibility and efficacy of EDTA delivered via porous balloon to target calcified lesions in cadaveric below-the-knee (BTK) arteries. METHODS: Using porcine carotid arteries, EDTA concentration was measured in the arterial wall and outside the artery at the 0-, 0.5-, 4-, and 24-h circulation after the injection through a porous balloon. In cadaver BTK samples, the proximal and distal anterior tibial artery (ATA) and distal posterior tibial artery (PTA) were studied. EDTA-2Na/H2O or EDTA-3Na/H2O were administrated using a porous balloon, then circulated for 6 h for EDTA-3Na/H2O and 24 h for EDTA-2Na/H2O and EDTA-3Na/H2O. Micro-CT imaging of the artery segments before and after the circulation and cross-sectional analyses were performed to evaluate calcium burden. RESULTS: In the porcine carotid study, EDTA was delivered through a porous balloon present in the arterial wall and was retained there for 24 h. In BTK arteries, cross-sectional analyses of micro-CT revealed a significant decrease in the calcium area in the distal ATA segment under 24-h circulation with EDTA-2Na/H2O and in the distal ATA segment under 24-h circulation with EDTA-3Na/H2O. The proximal ATA segment under 6-h circulation with EDTA-3Na/H2O showed no significant change in any parameters of calcium CONCLUSION: EDTA-3Na/H2O or EDTA-2Na/H2O with longer circulation times resulted in greater calcium reduction in atherosclerotic lesion. EDTA may have a potential therapeutic option for the treatment of atherosclerotic calcified lesions.


Assuntos
Angioplastia com Balão , Ácido Edético , Estudos de Viabilidade , Calcificação Vascular , Animais , Ácido Edético/farmacologia , Angioplastia com Balão/instrumentação , Porosidade , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Cadáver , Artérias da Tíbia/diagnóstico por imagem , Quelantes de Cálcio/farmacologia , Fatores de Tempo , Microtomografia por Raio-X , Humanos , Dispositivos de Acesso Vascular , Desenho de Equipamento , Sus scrofa , Doença Arterial Periférica/terapia , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/metabolismo , Placa Aterosclerótica , Suínos
3.
J Vasc Interv Radiol ; 35(7): 949-962.e13, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38554948

RESUMO

PURPOSE: To evaluate the clinical effectiveness and safety of drug-coated balloons (DCBs) compared with those of percutaneous transluminal angioplasty (PTA) for arteriovenous fistula (AVF) stenosis via a review of systematic reviews (SRs) and an update of the current meta-analysis. MATERIALS AND METHODS: Literature was searched to retrieve SRs comparing DCBs and PTA for AVFs. A narrative review of SRs and pooled analysis were performed. RESULTS: Eleven SRs were included. DCBs demonstrated favorable outcomes at 6 and 12 months compared with PTA, with improved patency in 7 SRs and a trend toward favorable outcomes without statistical significance in 3 SRs. Target lesion revascularization (TLR) was reported in 3 SRs; 2 reviews reported a significantly lower incidence in the DCB group than in the PTA group, whereas 1 review reported no significant differences at 12 months. Four studies reporting all-cause mortality revealed no significant difference between the 2 treatments. In the updated meta-analysis including 23 studies, DCBs demonstrated improved primary patency at 6 months (risk ratio [RR], 1.27; 95% CI, 1.07-1.50) and 12 months (RR, 1.36; 95% CI, 1.19-1.55) and were associated with a lower incidence of TLR at 6 months (RR, 0.54; 95% CI, 0.41-0.73) and 12 months (RR, 0.78; 95% CI, 0.62-0.99). There was no difference in mortality between the 2 groups for 24 months. CONCLUSIONS: A review of SRs and meta-analysis update revealed the consistent benefits of DCBs over PTA in treating AVFs in terms of primary patency and TLR. Compared with PTA, DCBs do not increase mortality risk.


Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica , Materiais Revestidos Biocompatíveis , Grau de Desobstrução Vascular , Humanos , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Angioplastia com Balão/mortalidade , Resultado do Tratamento , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Derivação Arteriovenosa Cirúrgica/mortalidade , Oclusão de Enxerto Vascular/terapia , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/diagnóstico por imagem , Fatores de Risco , Diálise Renal , Dispositivos de Acesso Vascular , Desenho de Equipamento , Fatores de Tempo
4.
J Cardiovasc Magn Reson ; 26(1): 100993, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38218433

RESUMO

BACKGROUND: Percutaneous-transluminal renal angioplasty (PTRA) and stenting aim to halt the progression of kidney disease in patients with renal artery stenosis (RAS), but its outcome is often suboptimal. We hypothesized that a model incorporating markers of renal function and oxygenation extracted using radiomics analysis of blood oxygenation-level dependent (BOLD)-MRI images may predict renal response to PTRA in swine RAS. MATERIALS AND METHODS: Twenty domestic pigs with RAS were scanned with CT and BOLD MRI before and 4 weeks after PTRA. Stenotic (STK) and contralateral (CLK) kidney volume, blood flow (RBF), and glomerular filtration rate (GFR) were determined, and BOLD-MRI R2 * maps were generated before and after administration of furosemide, a tubular reabsorption inhibitor. Radiomics features were extracted from pre-PTRA BOLD maps and Robust features were determined by Intraclass correlation coefficients (ICC). Prognostic models were developed to predict post-PTRA renal function based on the baseline functional and BOLD-radiomics features, using Lasso-regression for training, and testing with resampling. RESULTS: Twenty-six radiomics features passed the robustness test. STK oxygenation distribution pattern did not respond to furosemide, whereas in the CLK radiomics features sensitive to oxygenation heterogeneity declined. Radiomics-based model predictions of post-PTRA GFR (r = 0.58, p = 0.007) and RBF (r = 0.68; p = 0.001) correlated with actual measurements with sensitivity and specificity of 92% and 67%, respectively. Models were unsuccessful in predicting post-PTRA systemic measures of renal function. CONCLUSIONS: Several radiomics features are sensitive to cortical oxygenation patterns and permit estimation of post-PTRA renal function, thereby distinguishing subjects likely to respond to PTRA and stenting.


Assuntos
Modelos Animais de Doenças , Taxa de Filtração Glomerular , Imageamento por Ressonância Magnética , Valor Preditivo dos Testes , Obstrução da Artéria Renal , Circulação Renal , Stents , Sus scrofa , Obstrução da Artéria Renal/fisiopatologia , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/terapia , Animais , Oxigênio/sangue , Fatores de Tempo , Córtex Renal/diagnóstico por imagem , Córtex Renal/irrigação sanguínea , Córtex Renal/fisiopatologia , Córtex Renal/metabolismo , Furosemida/administração & dosagem , Angioplastia com Balão/instrumentação , Artéria Renal/diagnóstico por imagem , Artéria Renal/fisiopatologia , Feminino , Masculino , Diuréticos , Interpretação de Imagem Assistida por Computador , Resultado do Tratamento , Radiômica
5.
BMC Cardiovasc Disord ; 24(1): 315, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38909188

RESUMO

INTRODUCTION: Fibrosing mediastinitis (FM) is a rare disease characterized by excessive proliferation of fibrous tissue in the mediastinum and can cause bronchial stenosis, superior vena cava obstruction, pulmonary artery and vein stenosis, etc. CASE PRESENTATION: An aging patient with intermittent chest tightness and shortness of breath was diagnosed with FM associated pulmonary hypertension (FM-PH) by echocardiography and enhanced CT of the chest, and CT pulmonary artery (PA)/ pulmonary vein (PV) imaging revealed PA and PV stenosis. Selective angiography revealed complete occlusion of the right upper PV, and we performed endovascular intervention of the total occluded PV. After failure of the antegrade approach, the angiogram revealed well-developed collaterals of the occluded RSPV-V2b, so we chose to proceed via the retrograde approach. We successfully opened the occluded right upper PV and implanted a stent. CONCLUSIONS: This report may provide new management ideas for the interventional treatment of PV occlusion.


Assuntos
Veias Pulmonares , Stents , Humanos , Resultado do Tratamento , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Veias Pulmonares/cirurgia , Doença Crônica , Pneumopatia Veno-Oclusiva/terapia , Pneumopatia Veno-Oclusiva/diagnóstico por imagem , Pneumopatia Veno-Oclusiva/fisiopatologia , Pneumopatia Veno-Oclusiva/etiologia , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/terapia , Estenose de Veia Pulmonar/fisiopatologia , Estenose de Veia Pulmonar/etiologia , Mediastinite/diagnóstico , Mediastinite/terapia , Masculino , Flebografia , Angioplastia com Balão/instrumentação , Idoso , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/terapia , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/diagnóstico por imagem , Fibrose , Circulação Colateral , Circulação Pulmonar , Feminino
6.
Heart Vessels ; 39(7): 582-588, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38363331

RESUMO

The objective of the study is to investigate the difference in 1-year late lumen loss (LLL) between the high- (IN.PACT Admiral) and low-dose (Lutonix) paclitaxel-coated balloon (PCB). Although a recent randomized clinical trial demonstrated no difference in efficacy endpoint between high- and low-dose PCB, it remains unclear whether high-dose PCB was superior to low-dose PCB in actual clinical practice. We enrolled 64 patients with 67 de novo femoropopliteal lesions who underwent PCB angioplasty at Kokura Memorial Hospital from May 2014 to March 2020 and subsequent follow-up angiography after 1 year. The primary endpoint was 1-year LLL, whereas the secondary endpoints were binary restenosis and clinically driven target lesion revascularization (CD-TLR) after 1 year. The high- and low-dose PCB groups had 45 and 22 lesions, respectively. Although the low-dose PCB group had higher rates of coronary artery disease, hemodialysis, and chronic limb-threatening ischemia than the high-dose PCB group, the latter had a longer lesion length and more lesions with a TASC classification C or D than the former. The high-dose PCB group had a significantly lower LLL than the low-dose PCB group (0.40 ± 1.05 vs. 1.19 ± 1.03 mm; P = 0.003, respectively). Moreover, the high-dose PCB group had significantly lower rates of binary restenosis at 1 year than the low-dose PCB group (22.2% vs. 50.0%; P = 0.02, respectively). Moreover, negative LLL was only observed in the high-dose PCB group (33.3% vs. 0%, P = 0.005). The high-dose PCB group had a significantly lower LLL than the low-dose PCB group.


Assuntos
Angioplastia com Balão , Materiais Revestidos Biocompatíveis , Artéria Femoral , Paclitaxel , Doença Arterial Periférica , Artéria Poplítea , Humanos , Paclitaxel/administração & dosagem , Artéria Poplítea/diagnóstico por imagem , Masculino , Feminino , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/terapia , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Idoso , Angioplastia com Balão/instrumentação , Angioplastia com Balão/métodos , Angioplastia com Balão/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Fatores de Tempo , Grau de Desobstrução Vascular , Pessoa de Meia-Idade , Dispositivos de Acesso Vascular , Seguimentos , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos
7.
Ann Vasc Surg ; 105: 201-208, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38604500

RESUMO

BACKGROUND: Endovascular treatment (EVT) for aortoiliac (AI) occlusive lesions is now conducted worldwide, but there are challenges in EVT for complex AI lesions. The VIABAHN VBX (W.L. Gore & Associates, Flagstaff, AZ) is a next-generation balloon-expandable covered stent designed for use with complex AI lesions. The purpose of this study is to evaluate the medium-term outcomes of VIABAHN VBX for such lesions. METHODS: Symptomatic patients who underwent EVT with VIABAHN VBX for an AI lesion from 2018 to 2020 at 7 Japanese centers were reviewed retrospectively. The primary endpoints were primary patency and freedom from target lesion revascularization (TLR). RESULTS: A total of 95 EVT procedures with VIABAHN VBX for AI occlusive lesions were performed in 71 patients. The patients had high rates of dyslipidemia (53%) and chronic kidney disease (61%), and 22% had chronic limb-threatening ischemia (CLTI). The Transatlantic Inter-Society Consensus (TASC Ⅱ) class was A in 12 patients (17%), B in 12 (17%), C in 10 (14%), and D in 37 (52%). Severe calcification (360°) of the treated lesion was present in 31 patients (33%). The median procedure time was 84 (49-158) min, with a technical success rate of 100%. The median follow-up period was 36 (32-43) months. The 3-year primary and secondary patency of VIABAHN VBX were 91% and 99%, the 3-year freedom from TLR was 92%, and the 3-year freedom from major adverse limb event (MALE) was 98%. No limbs required major amputation. Lesion severity (TASC Ⅱ C or D) and severe calcification did not affect the primary patency or freedom from TLR. CONCLUSIONS: Medium-term outcomes after EVT with VIABAHN VBX for AI lesions were acceptable regardless of lesion severity and calcification. These results suggest that VIABAHN VBX may be suitable for AI occlusive lesions with severe anatomical complexity and/or severe calcification.


Assuntos
Doenças da Aorta , Artéria Ilíaca , Doença Arterial Periférica , Desenho de Prótese , Stents , Grau de Desobstrução Vascular , Humanos , Masculino , Feminino , Idoso , Estudos Retrospectivos , Artéria Ilíaca/fisiopatologia , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Fatores de Tempo , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Pessoa de Meia-Idade , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Doenças da Aorta/cirurgia , Japão , Resultado do Tratamento , Idoso de 80 Anos ou mais , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Fatores de Risco , Salvamento de Membro
8.
Ann Vasc Surg ; 104: 205-216, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38492725

RESUMO

BACKGROUND: This Bayesian network meta-analysis (NMA) sought to evaluate the efficacy of different endovascular treatments for femoropopliteal artery in-stent restenosis (FP-ISR). METHODS: PubMed, Embase, Cochrane Central Register of Controlled Trials, and Web of science for clinical trials from database inception to March 31, 2023, with no language restrictions to retrieve randomized controlled trials or cohort studies evaluating the impact of any kind of endovascular treatments for FP-ISR. Pair-wise meta-analysis and Bayesian NMA were performed to pool the outcome estimates different endovascular treatments. The primary end points under consideration were primary patency rates at both 6-month and 12-month follow-up. RESULTS: A total of 15 studies with 1,424 patients were ultimately enrolled to be analyzed, 7 types of endovascular treatment were identified for comparison. In terms of primary patency and freedom from target lesion revascularization (TLR) at 6-month and12-month follow-up, the direct meta-analysis findings showed that drug-coated balloons (DCB) and covered stent (CS) are considerably superior to plain old balloon angioplasty (POBA), Excimer laser atherectomy (ELA) + DCB is significantly better than DCB. According to the meta-analysis based on Bayesian theory, during the 6-month and 12-months follow-up, we could not find significant difference between the different treatments in terms of the primary patency and the freedom from TLR, based on the surface values under the cumulative ranking curve (SUCRA), CS was considered the best treatment in terms of primary patency (6 months SUCRA = 85.2; 12 months SUCRA = 78.9) and freedom from TLR (6 months SUCRA = 84.9; 12 months SUCRA = 70.9); directional atherectomy + POBA may lead to higher survival rate at 12 months (SUCRA = 89.1) than others treatments; in addition, both ELA + POBA and ELA + DCB have higher limb salvage than POBA. CONCLUSIONS: The findings of this NMA suggest that CS showed positive encouraging results in primary patency and TLR in FP-ISR at 6 and 12 months. However, due to the potential influence of certain confounding factors, the long-term results necessitate validation through numerous randomized controlled trials.


Assuntos
Procedimentos Endovasculares , Artéria Femoral , Doença Arterial Periférica , Artéria Poplítea , Stents , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Teorema de Bayes , Materiais Revestidos Biocompatíveis , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Artéria Femoral/fisiopatologia , Artéria Femoral/diagnóstico por imagem , Metanálise em Rede , Doença Arterial Periférica/terapia , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
9.
Ann Vasc Surg ; 104: 196-204, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38492729

RESUMO

BACKGROUND: The treatment of atherosclerotic lesions in the popliteal artery is challenging. This study aims to investigate the efficacy and safety of excimer laser ablation (ELA) combined with drug-coated balloon (DCB) for these lesions. METHODS: From June 2019 to December 2021, data of patients who underwent ELA combined with DCB in the popliteal artery were retrospectively reviewed. Demographics, lesion characteristics, periprocedural complications, and follow-up information were analyzed. The primary endpoint was primary patency. Secondary endpoints included major amputation-free survival rate, technical success, bailout stenting, clinically-driven target lesion reintervention, improvement of ankle-brachial index (ABI), and Rutherford class. RESULTS: A total of 61 patients were enrolled. The mean age was 73.4 ± 11.7 years. 20 (32.8%) patients had stenotic lesions, while 41 (67.2%) patients had chronic total occlusions. The mean length of these lesions was 7.3 ± 2.8 cm. Procedure technical success rate was 95.1%. Bailout stent was performed in 3 (4.9%) patients. Intraprocedural distal embolization occurred in 3 (4.9%) patients, while flow limiting dissections occurred in 3 (4.9%) patients. The mean ABI was significantly improved from 0.45 ± 0.13 at baseline to 0.90 ± 0.12 after ELA, 0.88 ± 0.11 at 6 months and 0.85 ± 0.12 at 12 months during the follow-up period. The median follow-up time was 28.2 ± 6.1 months. Reintervention was performed in 5 (8.2%) patients. The 2-year primary patency was 83.5%. CONCLUSIONS: ELA combined with DCB is a safe and effective strategy in the treatment of popliteal artery atherosclerotic lesions with low rates of bail-out stenting and high primary patency.


Assuntos
Angioplastia com Balão , Materiais Revestidos Biocompatíveis , Lasers de Excimer , Doença Arterial Periférica , Artéria Poplítea , Grau de Desobstrução Vascular , Humanos , Masculino , Feminino , Idoso , Artéria Poplítea/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/cirurgia , Estudos Retrospectivos , Lasers de Excimer/uso terapêutico , Pessoa de Meia-Idade , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Idoso de 80 Anos ou mais , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/terapia , Doença Arterial Periférica/diagnóstico por imagem , Fatores de Tempo , Dispositivos de Acesso Vascular , Resultado do Tratamento , Salvamento de Membro , Fatores de Risco , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Intervalo Livre de Progressão , Amputação Cirúrgica
10.
J Neuroradiol ; 51(4): 101175, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38219959

RESUMO

OBJECTIVE: This study aimed to compare the safety and efficacy of the Atlas stent released by the Gateway catheter and microcatheter in the treatment of intracranial stenosis (IS). METHODS: The primary efficacy and safety outcomes were the in-stent restenosis (ISR) rate and post-procedural stroke or death within one month. RESULTS: Atlas stents were deployed using the Gateway catheter and microcatheter in 19 (57.6 %) and 14 (42.4 %) procedures, respectively. Follow-up imaging data were available for 26 patients; the incidence of ISR was 15.4 %, and the ISR rate was higher, though not significantly, in the microcatheter group than in the Gateway group (30.0% vs. 6.25 %, P = .39). Clinical follow-up data were available for 30 patients; the post-procedural stroke rate was 3.3 % within one month and 13.3 % from one month to one year. The post-procedural stroke rate within one month was higher, though not significantly, in the microcatheter group than in the Gateway group (7.7% vs. 0 %, P = .43). The Gateway group had a significantly lower rate of post-procedural stroke in the same territory than that of the microcatheter group (0% vs. 30.8 %, P = .026). A higher incidence of residual stenosis <30 % was found in the non-ISR group than in the ISR group (72.2% vs. 0 %, P = .014). CONCLUSIONS: This study provides preliminary evidence that the Atlas stent is safe and effective for IS treatment. The use of the Gateway catheter to deliver the Atlas stent appears to be safer than using microcatheter. The incidence of ISR may be related to the degree of the residual stenosis.


Assuntos
Stents , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso , Acidente Vascular Cerebral/etiologia , Angioplastia com Balão/instrumentação , Angioplastia com Balão/métodos , Estudos Retrospectivos , Adulto
11.
N Engl J Med ; 383(8): 733-742, 2020 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-32813949

RESUMO

BACKGROUND: Standard percutaneous transluminal angioplasty is the current recommended treatment for dysfunctional hemodialysis fistulas, yet long-term outcomes of this treatment are poor. Drug-coated balloons delivering the antirestenotic agent paclitaxel may improve outcomes. METHODS: In this prospective, single-blinded, 1:1 randomized trial, we enrolled 330 participants at 29 international sites. Patients with new or restenotic lesions in native upper-extremity arteriovenous fistulas were eligible for participation. After successful high-pressure percutaneous transluminal angioplasty, participants were randomly assigned to receive treatment with a drug-coated balloon or a standard balloon. The primary effectiveness end point was target-lesion primary patency, defined as freedom from clinically driven target-lesion revascularization or access-circuit thrombosis during the 6 months after the index procedure. The primary safety end point, serious adverse events involving the arteriovenous access circuit within 30 days, was assessed in a noninferiority analysis (margin of noninferiority, 7.5 percentage points). The primary analyses included all participants with available end-point data. Additional sensitivity analyses were performed to assess the effect of missing data. RESULTS: A total of 330 participants underwent randomization; 170 were assigned to receive treatment with a drug-coated balloon, and 160 were assigned to receive treatment with a standard balloon. During the 6 months after the index procedure, target-lesion primary patency was maintained more often in participants who had been treated with a drug-coated balloon than in those who had been treated with a standard balloon (82.2% [125 of 152] vs. 59.5% [88 of 148]; difference in risk, 22.8 percentage points; 95% confidence interval [CI], 12.8 to 32.8; P<0.001). Drug-coated balloons were noninferior to standard balloons with respect to the primary safety end point (4.2% [7 of 166] and 4.4% [7 of 158], respectively; difference in risk, -0.2 percentage points; 95% CI, -5.5 to 5.0; P = 0.002 for noninferiority). Sensitivity analyses confirmed the results of the primary analyses. CONCLUSIONS: Drug-coated balloon angioplasty was superior to standard angioplasty for the treatment of stenotic lesions in dysfunctional hemodialysis arteriovenous fistulas during the 6 months after the procedure and was noninferior with respect to access circuit-related serious adverse events within 30 days. (Funded by Medtronic; IN.PACT AV Access Study ClinicalTrials.gov number, NCT03041467.).


Assuntos
Angioplastia com Balão/métodos , Derivação Arteriovenosa Cirúrgica , Fármacos Cardiovasculares/administração & dosagem , Paclitaxel/administração & dosagem , Dispositivos de Acesso Vascular/efeitos adversos , Grau de Desobstrução Vascular , Idoso , Angioplastia com Balão/instrumentação , Derivação Arteriovenosa Cirúrgica/instrumentação , Fármacos Cardiovasculares/efeitos adversos , Materiais Revestidos Biocompatíveis , Constrição Patológica/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Estudos Prospectivos , Diálise Renal/efeitos adversos , Método Simples-Cego , Extremidade Superior/irrigação sanguínea
12.
Eur J Vasc Endovasc Surg ; 63(1): 60-71, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34326002

RESUMO

OBJECTIVE: There have been concerns about the long term safety of paclitaxel coated devices in the lower limbs. A formal systematic review and meta-analysis of randomised controlled trials (RCTs) was performed to examine the long term risk of major amputation using paclitaxel coated balloons in peripheral arterial disease (PAD). METHOD: This systematic review was registered with PROSPERO (ID 227761). A broad bibliographic search was performed for RCTs investigating paclitaxel coated balloons in the peripheral arteries (femoropopliteal and infrapopliteal) for treatment of intermittent claudication or critical limb ischaemia (CLI). The literature search was last updated on 20 February 2021 without any restrictions on publication language, date, or status. Major amputations were analysed with time to event methods employing one and two stage models. Sensitivity and subgroup analyses, combinatorial meta-analysis, and a multivariable dose response meta-analysis to examine presence of a biological gradient were also performed. RESULTS: In all, 21 RCTs with 3 760 lower limbs were analysed (52% intermittent claudication and 48% CLI; median follow up two years). There were 87 major amputations of 2 216 limbs in the paclitaxel arms (4.0% crude risk) compared with 41 major amputations in 1 544 limbs in the control arms (2.7% crude risk). The risk of major amputation was significantly higher for paclitaxel coated balloons with a hazard ratio (HR) of 1.66 (95% CI 1.14 - 2.42; p = .008, one stage stratified Cox model). The prediction interval was 95% CI 1.10 - 2.46 (two stage model). The observed amputation risk was consistent for both femoropopliteal (p = .055) and infrapopliteal (p = .055) vessels. Number needed to harm was 35 for CLI. There was good evidence of a significant non-linear dose response relationship with accelerated risk per cumulative paclitaxel dose (chi square model p = .007). There was no evidence of publication bias (p = .80) and no significant statistical heterogeneity between studies (I2 = 0%, p = .77). Results were stable across sensitivity analyses (different models and subgroups based on anatomy and clinical indication and excluding unpublished trials). There were no influential single trials. Level of certainty in evidence was downrated from high to moderate because of sparse events in some studies. CONCLUSION: There appears to be heightened risk of major amputation after use of paclitaxel coated balloons in the peripheral arteries. Further investigations are warranted urgently.


Assuntos
Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Extremidade Inferior/cirurgia , Paclitaxel/administração & dosagem , Doença Arterial Periférica/cirurgia , Angioplastia com Balão/métodos , Artéria Femoral/cirurgia , Humanos , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/complicações , Artéria Poplítea/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco
13.
Eur J Vasc Endovasc Surg ; 63(2): 315-322, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34824011

RESUMO

OBJECTIVE: The optimal endovascular treatment for common iliac artery in stent re-stenosis has yet to be assessed. Treatment options include, among others, angioplasty alone and repeated stenting with covered stents. METHODS: This study retrospectively compared patency and target lesion revascularisation of these treatments. All patients who underwent endovascular treatment of common iliac artery in stent re-stenosis between 2007 and 2017 were included retrospectively. The primary end point was freedom from re-stenosis. Secondary endpoints were target lesion revascularisation rate (TLR) and freedom from occlusion during follow up. RESULTS: Seventy-four interventions were included, consisting of 37 angioplasties and 37 covered stent placements in 57 patients. Freedom from re-stenosis at four years was 72.6% (95% confidence interval [CI] 51.8% - 88.7%) in the covered stent group vs. 43.5% (95% CI 25.9% - 59.8%) in the percutaneous transluminal angioplasty (PTA) group (p = .003). The target lesion revascularisation (TLR) rate was 16.4% (95% CI 7.1% - 35.6%) and 43.6% (95% CI 28.0% - 63.2%) respectively (p = .020). There was no difference in freedom from occlusion; this was 90.8% (95% CI 73.9% - 97.0%) in the covered stent group and 79.1% (95% CI 58.4% - 90.3%) in the PTA group (p = .49). The difference in freedom from re-stenosis and TLR remained significant after sensitivity and multivariable analyses. CONCLUSION: Covered stents offer better outcomes for common iliac artery in stent re-stenosis than angioplasty alone.


Assuntos
Angioplastia com Balão/métodos , Procedimentos Endovasculares/métodos , Doença Arterial Periférica/cirurgia , Complicações Pós-Operatórias/cirurgia , Stents/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/instrumentação , Aterosclerose/cirurgia , Constrição Patológica/cirurgia , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Artéria Ilíaca/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular
14.
Ann Vasc Surg ; 79: 162-173, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34644639

RESUMO

BACKGROUND: Atherectomy is currently being used extensively for occlusive peripheral artery disease (PAD) interventions without proven benefits. This analysis examines the effects of atherectomy and other endovascular interventions on patient survival. OBJECTIVES: The aim of this study is to compare overall survival for patients undergoing PAD endovascular interventions, such as plain old balloon angioplasty (POBA), stent deployment and atherectomy. METHODS: Propensity score matched cohorts were constructed to conduct pairwise comparisons of overall survival in patients who underwent stenosis and occlusive PAD interventions between May 2011 and February 2020 using Vascular Quality Initiative (VQI) regional registry data. Inverse probability treatment weighting method was used to compare secondary outcomes of in-hospital mortality, length of stay, complications and major amputations. Comparative analysis was performed for POBA vs stenting, POBA vs atherectomy, and stenting vs atherectomy. RESULTS: A total number of 15281 eligible cases were identified. After propensity score matching, 6094, 4032, and 3312 cases were used to compare POBA versus stent deployment, POBA versus atherectomy and stent versus atherectomy, respectively. Stent deployment had significantly better overall survival compared with POBA and atherectomy (P < 0.001). Multivariable Cox proportional hazard models suggested stenting was associated with a reduction in mortality hazard by 30% compared with POBA (HR: 0.7; 95% CI: 0.6-0.82; P < 0.001) and a 40% mortality reduction compared with atherectomy (HR: 0.6; 95% CI: 0.48-0.75; P < 0.001). No significant difference was found between POBA and atherectomy. There was no statistical difference in other secondary outcomes which were comparable among all cohorts. CONCLUSIONS: Stent deployment was significantly superior to POBA and atherectomy in terms of overall survival with comparable complication and amputation rates. The natural history of PAD patients presenting with claudication is associated with an extremely low annual mortality risk. Therefore, further examinations of outcomes, especially in regards to mortality rates, both POBA and atherectomy on the management of PAD patients especially those presenting with claudication is warranted.


Assuntos
Angioplastia com Balão , Aterectomia , Doença Arterial Periférica/terapia , Idoso , Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Angioplastia com Balão/mortalidade , Aterectomia/efeitos adversos , Aterectomia/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Tempo de Internação , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Pontuação de Propensão , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
15.
Ann Vasc Surg ; 79: 324-334, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34648854

RESUMO

BACKGROUND: Fully absorbable polymeric scaffolds, as a potential alternative to permanent metallic stents, are entering the clinical field. The aim of this study is to assess the in vivo biocompatibility of a novel Sirolimus-eluting (SIR) absorbable scaffold based on poly(L-lactide) (PLLA) and poly(4-hydroxybutyrate) (P4HB) for interventional application. METHODS: Absorbable PLLA/P4HB scaffolds either loaded with SIR coating or unloaded scaffolds were implanted interventionally into common carotid arteries of 14 female. Bare metal stents (BMS) served as control. Peroral dual anti-platelet therapy was administered throughout the study. Stented common carotid arteries segments were explanted after 4 weeks, and assessed histomorphometrically. RESULTS: The absorbable scaffolds showed a decreased residual lumen area and higher stenosis after 4 weeks (PLLA/P4HB: 6.56 ± 0.41 mm² and 37.56 ± 4.67%; SIR-PLLA/P4HB: 6.90 ± 0.58 mm² and 35.60 ± 3.15%) as compared to BMS (15.29 ± 1.86 mm² and 7.65 ± 2.27%). Incorporation of SIR reduced the significantly higher inflammation of unloaded scaffolds however not to a level compared to bare metal stent (PLLA/P4HB: 1.20 ± 0.19; SIR-PLLA/P4HB: 0.96 ± 0.24; BMS: 0.54 ± 0.12). In contrast, the BMS showed a slightly elevated vascular injury score (0.74 ± 0.15), as compared to the PLLA/P4HB (0.54 ± 0.20) and the SIR-PLLA/P4HB (0.48 ± 0.15) groups. CONCLUSION: In this preclinical model, the new absorbable polymeric (SIR-) scaffolds showed similar technical feasability and safety for vascular application as the permanent metal stents. The higher inflammatory propensity of the polymeric scaffolds was slightly reduced by SIR-coating. A smaller strut thickness of the polymeric scaffolds might have been a positive effect on tissue ingrowth between the struts and needs to be addressed in future work on the stent design.


Assuntos
Implantes Absorvíveis , Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Artéria Carótida Primitiva/patologia , Poliésteres , Sirolimo/administração & dosagem , Angioplastia com Balão/efeitos adversos , Animais , Artéria Carótida Primitiva/diagnóstico por imagem , Estenose das Carótidas/etiologia , Estenose das Carótidas/patologia , Inflamação/etiologia , Inflamação/patologia , Teste de Materiais , Modelos Animais , Desenho de Prótese , Sus scrofa , Fatores de Tempo
16.
Ann Vasc Surg ; 78: 379.e1-379.e5, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34481882

RESUMO

BACKGROUND: To describe a retrograde recanalization for the proximal occluded lesion in right renal artery (RRA) in young patient with fibromuscular dysplasia (FMD). METHODS: A 10-year-old girl presented to our hospital with proximal RRA occlusion and refractory hypertension though she took anti-hypertension medicines. Her renin and aldosterone were beyond the normal level in both base state and excited state. Her glomerular filtration rate at right kidney was only 18.4 ml/min. Angiography revealed proximal RRA occlusion and a compensated collateral artery (CCA) from the infrarenal aorta to the RRA. She was thus diagnosed with focal FMD. A retrograde recanalization was performed through this CCA. RESULTS: Angioplasty and stenting were successfully performed to treat the proximal RRA occlusion. Postoperatively, the glomerular filtration rate in the right kidney improved. One-year follow-up revealed that, the blood pressure maintained at normal range without any antihypertensive agents. No other discomfort was complained. CONCLUSIONS: It is feasible to establish a working pathway with patient's compensated collateral artery to treat the renal artery occlusion.


Assuntos
Angioplastia com Balão , Circulação Colateral , Displasia Fibromuscular/complicações , Hipertensão Renovascular/terapia , Obstrução da Artéria Renal/terapia , Circulação Renal , Angioplastia com Balão/instrumentação , Pressão Sanguínea , Criança , Feminino , Displasia Fibromuscular/diagnóstico , Displasia Fibromuscular/fisiopatologia , Humanos , Hipertensão Renovascular/diagnóstico , Hipertensão Renovascular/etiologia , Hipertensão Renovascular/fisiopatologia , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/etiologia , Obstrução da Artéria Renal/fisiopatologia , Stents , Resultado do Tratamento
17.
Ren Fail ; 44(1): 155-170, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35166168

RESUMO

PURPOSE: To compare the efficacy and safety between paclitaxel coated balloon (PCB) angioplasty and conventional balloon (CB) angioplasty in the treatment of dysfunctional arteriovenous fistula (AVF). METHODS: We searched four major electronic databases (PubMed, EMBASE, Web of Science and the Cochrane Library) for randomized controlled trials (RCTs) published from inception through November 28, 2021. Outcomes of interest included target lesion primary patency (TLPP), technical success and all-cause mortality. The STATA package version 15.1 was utilized to undertake meta-analyses. RESULTS: Fourteen RCTs totaling 1535 patients were analyzed. The available data showed that there were no significant differences of TLPP rates at 3, 6, 9 and 12 months between the PCB group and the CB group (risk ratio (RR) 1.00, 95% confidence interval (CI) 0.93-1.07, p = 1.000, I2 = 33.5%, Cochrane Q test p = 0.185, fixed-effect model; RR 1.17, 95% CI 0.99-1.39, p = 0.065, I2 = 75.4%, Cochrane Q test p = 0.000, random-effect model; RR 0.81, 95% CI 0.35-1.89, p = 0.625, I2 = 62.8%, Cochrane Q test p = 0.045, random-effect model; RR 1.19, 95% CI 0.97-1.47, p = 0.096, I2 = 40.5%, Cochrane Q test p = 0.071, random-effect model). In addition, two groups had similar technical success rates (RR 1.00, 95% CI 0.97-1.03, p = 1.000, I2 = 0.0%, Cochrane Q test p = 0.596, fixed-effect model) and all-cause mortality rates (RR 1.00, 95% CI 0.54-1.84, p = 1.000, I2 = 0.0%, Cochrane Q test p = 0.599, fixed-effect model). CONCLUSIONS: PCB angioplasty did not appear to convey any obvious advantage over CB angioplasty in the treatment of dysfunctional AVF. However, further multi-center, large-scale and well-designed RCTs are needed to prove outcomes.


Assuntos
Angioplastia com Balão/instrumentação , Fístula Arteriovenosa/terapia , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Paclitaxel/administração & dosagem , Diálise Renal/efeitos adversos , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/mortalidade , Fístula Arteriovenosa/etiologia , Derivação Arteriovenosa Cirúrgica/mortalidade , Materiais Revestidos Biocompatíveis , Humanos , Paclitaxel/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Diálise Renal/mortalidade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
18.
Radiology ; 300(3): 715-724, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34227886

RESUMO

Background There is a paucity of randomized trials demonstrating superior efficacy of drug-coated balloon angioplasty (DCBA) compared with conventional percutaneous transluminal angioplasty (PTA) for below-the-knee arterial disease in patients with -critical limb ischemia. Purpose To compare DCBA versus PTA for below-the-knee lesions in participants with critical limb ischemia through 12 months. Materials and Methods In this prospective, randomized, two-center, double-blind superiority study, participants with critical limb ischemia with rest pain or tissue loss with atherosclerotic disease in the native below-the-knee arteries were randomly assigned (in a one-to-one ratio) to DCBA or PTA after stratification for diabetes and renal failure between November 2013 and October 2017. The primary efficacy end point was angiographic primary patency at 6 months analyzed on an intention-to-treat basis. Secondary end points through 12 months were composed of major adverse events including death and major amputations, wound healing, limb salvage, clinically driven target-lesion revascularization, and amputation-free survival. Primary and binary secondary end points, analyzed by using generalized-linear model and time-to-event analyses, were estimated with Kaplan-Meier survival curves and hazard ratios (Cox regression). Results Seventy participants (mean age, 61 years ± 10 [standard deviation]; 43 men) in the DCBA group and 68 (mean age, 64 years ± 10; 50 men) in the PTA group were evaluated. The percentage of patients with angiographic primary patency at 6 months was 43% (30 of 70) in the DCBA group and 38% (26 of 68) in the PTA group (P = .48). Through 12 months, the percentage of deaths was similar: 21% in the DCBA group and 16% in the PTA group (P = .43). Amputation-free survival rate assessed with Kaplan-Meier curves differed through 12 months: 59% (41 of 70) in the DCBA group compared with 78% (53 of 68) in the PTA group (P = .01). Conclusion In participants with critical limb ischemia, the drug-coated balloon angioplasty group and the conventional percutaneous transluminal angioplasty group had similar primary patency rates at 6 months after treatment of below-the-knee arteries. Amputation-free survival rates through 12 months were higher in the percutaneous transluminal angioplasty group. © RSNA, 2021 Online supplemental material is available for this article.


Assuntos
Angioplastia com Balão/instrumentação , Isquemia/cirurgia , Extremidade Inferior/irrigação sanguínea , Paclitaxel/administração & dosagem , Doença Arterial Periférica/cirurgia , Moduladores de Tubulina/administração & dosagem , Angiografia , Meios de Contraste , Método Duplo-Cego , Sistemas de Liberação de Medicamentos , Feminino , Humanos , Iohexol , Isquemia/diagnóstico por imagem , Salvamento de Membro , Extremidade Inferior/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Estudos Prospectivos
19.
Cardiovasc Diabetol ; 20(1): 221, 2021 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-34758835

RESUMO

BACKGROUND: RBP4 is an adipokine with an established role in atherosclerosis, while adiponectin has unique anti-inflammatory properties. We investigated the association of RBP4 and adiponectin with the presence of symptomatic peripheral artery disease (PAD) and their possible prognostic role in major adverse cardiovascular events (MACE). METHODS: We enrolled 168 consecutive patients with symptomatic, established PAD, requiring revascularization by endovascular means of any or both of their lower limbs. 88 age- and sex-matched subjects with less than 2 classical cardiovascular risk factors served as controls. Clinical parameters, glycemic and lipid profile, RBP4 and adiponectin levels were assayed. The occurrence of MACE was recorded during the 6-month follow-up and patients were assigned to MACE and non-MACE subgroups. RESULTS: The presence of symptomatic PAD was significantly correlated with age, diabetes, hsCRP, RBP4 and low adiponectin levels (p < 0.05). After adjustment for age, RBP4 (ß = 0.498, p < 0.001), and adiponectin (ß = -0.288, p < 0.001) levels remained as independent predictors of PAD presence in the whole study cohort. At baseline, MACE subgroup appeared with higher RBP-4 and hsCRP serum levels than non-MACE subgroup (p < 0.001), but no differences were detected for adiponectin (p = 0.758). Serum RBP4 levels remained independent predictor of MACE (ß = 0.455, p < 0.001) after adjustment for traditional cardiovascular risk factors. CONCLUSIONS: High RBP4 and low adiponectin serum levels are independently associated with PAD presence. In addition, RBP4 is an independent predictor of MACE incidence in symptomatic PAD patients.


Assuntos
Adiponectina/sangue , Angioplastia com Balão , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/terapia , Proteínas Plasmáticas de Ligação ao Retinol/análise , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Biomarcadores/sangue , Proteína C-Reativa/análise , Estudos de Casos e Controles , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/sangue , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/epidemiologia , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Stents , Resultado do Tratamento
20.
J Vasc Surg ; 73(6): 2198-2203.e3, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33385504

RESUMO

OBJECTIVE: We investigated the comparative effectiveness of different endovascular treatments for patients with failing autogenous arteriovenous fistulas (AVFs) with outflow vein stenosis. METHODS: The Medline (via PubMed) and SCOPUS databases were searched. We performed a systematic review and network meta-analysis of randomized controlled trials that had investigated the effectiveness of plain balloon angioplasty (PBA), cutting balloon angioplasty, and drug-coated balloon angioplasty (DCBA) to treat vein stenoses in autogenous AVFs. Studies of central vein stenosis were excluded. The main outcome measures were the failure rates at 6 months and 1 year after treatment. RESULTS: Eleven randomized controlled trials were included, with 814 patients, 395 of whom had undergone PBA. The network meta-analysis showed that DCBA at 6 months was significantly more effective than PBA (odds ratio, 0.39; 95% confidence interval, 0.18-0.81) and ranked as the best treatment option, although the difference was not statistically significant compared with cutting balloon angioplasty (odds ratio, 0.65; 95% confidence interval, 0.20-2.12). The differences among the three treatments at 1 year were not statistically significant. Additional conventional pairwise meta-analyses did not find significant differences at 1 year. CONCLUSIONS: In failing AVFs with outflow stenosis, DCBA was significantly superior to PBA, with improved 6-month failure rates. However the effectiveness of DCBA in the long term deserves further investigation.


Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Materiais Revestidos Biocompatíveis , Desenho de Equipamento , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Metanálise em Rede , Ensaios Clínicos Controlados Aleatórios como Assunto , Diálise Renal , Fatores de Tempo , Resultado do Tratamento , Dispositivos de Acesso Vascular , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS