Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Sep Sci ; 40(21): 4222-4233, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28837263

RESUMO

A new facile magnetic micro-solid-phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite-MCM-41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 µg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite-MCM-41 at pH 12. The analyte was desorbed using 100 µL of acetonitrile prior to gas chromatography determination. This method was rapid in which the adsorption procedure was completed in 60 s. Under the optimized conditions using 15 mL of antidepressant drugs sample, the calibration curve showed good linearity in the range of 0.05-500 µg/L (r2  = 0.996-0.999). Good limits of detection (0.008-0.010 µg/L) were obtained for the analytes with good relative standard deviations of <8.0% (n = 5) for the determination of 0.1, 5.0, and 500.0 µg/L of antidepressant drugs. This method was successfully applied to the determination of amitriptyline and chlorpromazine in plasma and urine samples. The recoveries of spiked plasma and urine samples were in the range of 86.1-115.4%. Results indicate that magnetite micro-solid-phase extraction with gas chromatography and mass spectrometry is a convenient, fast, and economical method for the extraction and determination of amitriptyline and chlorpromazine in biological samples.


Assuntos
Antidepressivos/sangue , Antidepressivos/urina , Óxido Ferroso-Férrico , Dióxido de Silício , Amitriptilina/sangue , Amitriptilina/urina , Clorpromazina/sangue , Clorpromazina/urina , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Nanopartículas de Magnetita , Extração em Fase Sólida
2.
J AOAC Int ; 96(2): 282-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23767351

RESUMO

Sequential injection chromatography (SIC) is a recent, simple, and inexpensive green miniaturized separation technique. In the current study, SIC was exploited for the first time for biochemical analysis. A new SIC method for the separation and quantification of chlorpromazine in human urine, as well as pharmaceutical formulations, was developed and validated. Clozapine was used as an internal standard. Chlorpromazine was successfully separated on a C18 monolithic column (25x4.6 mm id). The UV detection was carried out at 250 nm using miniaturized fiber optic spectrometric devices. The optimum mobile phase composition was 30 mmol/L phosphate-acetonitrile-methanol (55.0 + 31.5 + 13.5, v/v/v) at pH 3.0. The sample volume was 40 microL and flow rate was 40 microL/s. Acceptable chromatographic results were obtained. The resolution was 2.7, peak symmetry was 1.1, and number of theoretical plates was more than 1 x 10(6). Good linearity (r = 0.9997) in the range of 25-100 microg/mL was also obtained. The method offered acceptable recovery for both human urine (89.6-93.1%) and pharmaceutical formulations (96.9-98.5%), which was sensitive enough to detect chlorpromazine. The LOD and LOQ in human urine were 61 and 204 ng/mL, respectively. The method was rapid and reagent-saving, and hence safe for the environment. The sample throughput was 26.3 samples/h and the total volume of consumed reagents was 4.0 mL.


Assuntos
Antipsicóticos/química , Antipsicóticos/urina , Clorpromazina/química , Clorpromazina/urina , Cromatografia/métodos , Clozapina/química , Clozapina/urina , Humanos , Estrutura Molecular , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
J Huazhong Univ Sci Technolog Med Sci ; 31(2): 277-284, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21505999

RESUMO

A simple method has been proposed for the determination of clozapine (CLZ) and chlorpromazine (CPZ) in human urine by dispersive liquid-liquid microextraction (DLLME) in combination with high-performance liquid chromatography-ultraviolet detector (HPLC-UV). All important variables influencing the extraction efficiency, such as pH, types of the extraction solvent and the disperser solvent and their volume, ionic strength and centrifugation time were investigated and optimized. Under the optimal conditions, the limit of detection (LODs) and quantification (LOQs) of the method were 13 and 39 ng/mL for CLZ, and 2 and 6 ng/mL for CPZ, respectively. The relative standard deviations (RSDs) of the targets were less than 5.1% (C=0.100 µg/mL, n=9). Good linear behaviors over the tested concentration ranges were obtained with the values of R (2)>0.999 for the targets. The absolute extraction efficiencies of CLZ and CPZ from the spiked blank urine samples were 98.3% and 97.8%, respectively. The applicability of the technique was validated by analyzing urine samples and the mean recoveries for spiked urine samples ranged from 93.3% to 105.0%. The method was successfully applied for the determination of CLZ and CPZ in real human urine.


Assuntos
Clorpromazina/urina , Cromatografia Líquida de Alta Pressão/métodos , Clozapina/urina , Microextração em Fase Líquida/métodos , Antipsicóticos/urina , Humanos , Sensibilidade e Especificidade , Raios Ultravioleta
4.
Int J Legal Med ; 123(3): 247-52, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19048267

RESUMO

On-site drug screening devices are widely used today for their simple test procedures and instantaneous results. Among other devices, a Triage Drug of Abuse panel is considered to be highly reliable for its high specificity and sensitivity of abused drugs. Although it is known that a false positive amphetamine (AMP) result may be obtained from the urine samples containing putrefactive amines or ephedrine-related compounds, no clinical false negative methamphetamine results have been reported to date. However, a false negative Triage result was obtained from the urine of a fatal methamphetamine poisoning victim taking Vegetamine tablets. Further experimental analyses revealed that the cross-reactivity of methamphetamine and chlorpromazine metabolites, including nor-2-chlorpromazine sulfoxide, was the cause for a false negative Triage reaction for AMP. Forensic scientists and clinicians must be aware of the limitations of on-site drug testing devices and the need for the confirmatory laboratory tests for the precise identification and quantification of drugs in suspicious intoxication cases, as also recommended by the manufacturers.


Assuntos
Transtornos Relacionados ao Uso de Anfetaminas/diagnóstico , Antipsicóticos/urina , Clorpromazina/urina , Metanfetamina/intoxicação , Metanfetamina/urina , Fenobarbital/urina , Detecção do Abuso de Substâncias/instrumentação , Adulto , Transtornos Relacionados ao Uso de Anfetaminas/urina , Animais , Autopsia/legislação & jurisprudência , Clorpromazina/análogos & derivados , Reações Cruzadas , Combinação de Medicamentos , Reações Falso-Negativas , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Masculino , Ratos
5.
Ultrason Sonochem ; 59: 104696, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31430655

RESUMO

We report a novel electrochemical sensor for the sensitive and selective determination of the antipsychotic drug chlorpromazine (CPZ) based on the iron (Fe) nanoparticles-loaded graphene oxide (GO-Fe)/three dimensional (3D) honeycomb-like zinc oxide (ZnO) nanohybrid modified screen printed carbon electrode (SPCE). The 3D hierarchical honeycomb-like ZnO was synthesized using a novel aqueous hydrothermal method and the GO-Fe/ZnO nanohybrid was prepared based on an inexpensive and fast sonochemical method using a high-intensity ultrasonic bath (Delta DC200H, 200 W, 40 KHz). Characterizations including scanning electron microscopy, elemental mapping, transmission electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, and Raman spectroscopy were carried out as part of this work. The electrocatalytic oxidation behavior of CPZ at various electrodes was investigated using the cyclic voltammetry technique, through which the GO-Fe/ZnO modified SPCE was identified as the best performing electrode. The quantitative determination of CPZ was then performed using the differential pulse voltammetry technique. The as-prepared GO-Fe/ZnO/SPCE sensor exhibited a quick and sensitive response towards the oxidation of CPZ with linear concentration ranges from 0.02 to 172.74 µM and 222.48 to 1047.74 µM. The modified SPCE sensor displayed a low detection limit (LOD) of 0.02 µM and a high sensitivity of 7.56 µA µM-1 cm-2. The proposed sensor also showed remarkable operational and storage stability, reproducibility, and repeatability. Furthermore, the practicability of the GO-Fe/ZnO/SPCE sensor has been verified with real sample analysis using commercial antipsychotic CPZ tablets and human urine samples, and adequate recovery has been achieved.


Assuntos
Clorpromazina/análise , Grafite/química , Ferro/química , Limite de Detecção , Nanotecnologia , Ondas Ultrassônicas , Óxido de Zinco/química , Antipsicóticos/análise , Antipsicóticos/química , Antipsicóticos/urina , Técnicas de Química Sintética , Clorpromazina/química , Clorpromazina/urina , Eletroquímica , Eletrodos , Humanos , Concentração de Íons de Hidrogênio , Nanopartículas Metálicas/química , Modelos Moleculares , Conformação Molecular
6.
Anal Chem ; 80(8): 3050-7, 2008 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-18336013

RESUMO

Electrospray ionization (ESI)-time-of-flight (TOF) MS enables searching a wide number of pharmaco/toxicologically relevant compounds (PTRC) in biosamples. However, the number of identifiable PTRC depends on extension of reference database of chemical formulas/compound names. Previous approaches proposed in-house or commercial databases with limitations either in PTRC number or content (e.g., few metabolites, presence of non-PTRC). In the frame of development of a ESI-TOF PTRC screening procedure, a subset of PubChem Compound as reference database is proposed. Features of this database (approximately 50,500 compounds) are illustrated, and its performance evaluated through analysis by capillary electrophoresis (CE)-ESI-TOF of hair/blood/urine collected from subjects under treatment with known drugs or by comparison with reference standards. The database is rich in parent compounds of pharmaceutical and illicit drugs, pesticides, and poisons and contains many metabolites (including about 6000 phase I metabolites and 180 glucuronides) and related substances (e.g., impurities, esters). The average number of hits with identical chemical formula is 1.82 +/- 2.27 (median = 1, range 1-39). Minor deficiencies, redundancies, and errors have been detected that do not limit the potential of the database in identifying unknown PTRC. The database allows a much broader search for PTRC than other commercial/in-house databases of chemical formulas/compound names previously proposed. However, the probability that a search retrieves different PTRC having identical chemical formula is higher than with smaller databases, and additional information (anamnestic/circumstantial data, concomitant presence of parent drug and metabolite, selective sample preparation, liquid chromatographic retention, and CE migration behavior) must be used in order to focus the search more tightly.


Assuntos
Substâncias Perigosas/análise , Preparações Farmacêuticas/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Clorpromazina/intoxicação , Clorpromazina/urina , Citalopram/análise , Citalopram/metabolismo , Cocaína/sangue , Feminino , Cabelo/química , Substâncias Perigosas/metabolismo , Humanos , Preparações Farmacêuticas/metabolismo , Suicídio
7.
J Pharm Biomed Anal ; 45(5): 769-74, 2007 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-17988816

RESUMO

In the present work, hollow fiber liquid phase microextraction (HF-LPME) in conjunction with reversed-phase HPLC/UV was developed for extraction and determination of trace amounts of chlorpromazine in biological fluids. The drug was extracted from an 11 ml aqueous sample (source phase; SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase; MP) followed by the back-extraction into a second aqueous solution (receiving phase; RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency of the drug were examined and optimized. Under the optimal conditions, enrichment factor of 250, dynamic linear range of 1-500 microgl(-1), and limit of detection of 0.5 microgl(-1) were obtained for the drug. The percent relative intra-day and inter-day standard deviation (R.S.D.%) based on three replicate determinations were 6.7 and 10.3%, respectively. The method was applied to drug level monitoring in the biological fluids and satisfactory results were obtained.


Assuntos
Antipsicóticos/análise , Antipsicóticos/isolamento & purificação , Clorpromazina/análise , Clorpromazina/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Antipsicóticos/sangue , Antipsicóticos/química , Antipsicóticos/urina , Soluções Tampão , Clorpromazina/sangue , Clorpromazina/química , Clorpromazina/urina , Humanos , Concentração de Íons de Hidrogênio , Cinética , Membranas Artificiais , Microquímica/métodos , Estrutura Molecular , Concentração Osmolar , Padrões de Referência , Espectrofotometria Ultravioleta , Fatores de Tempo , Água/química
8.
J Clin Pathol ; 22(5): 602-4, 1969 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-5364446

RESUMO

A method is described for the detection of methaqualone and its metabolites in the presence of large doses of other drugs.


Assuntos
Metaqualona/metabolismo , Metaqualona/urina , Clorpromazina/urina , Cromatografia em Camada Fina , Difenidramina/urina , Humanos , Metadona/urina , Métodos
9.
J Pharm Biomed Anal ; 13(9): 1161-6, 1995 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8573643

RESUMO

A LC method was developed for the concurrent assay of R(+) and S(-) promethazine from human urine and serum. The method involves the use of solid-phase extraction for sample clean-up. Chromatographic resolution of the enantiomers was performed under isocratic conditions using a mobile phase of hexane-1,2-dichlorethane-absolute ethanol-trifluoroacetic acid (400:150:100:1, v/v/v/v) at a flow rate of 1 ml min-1 on a brush-type column KK-CARNU. The enantiomers were detected by fluorescence using an excitation wavelength of 250 nm and a 280 nm emission cutoff filter. Chlorpromazine was used as the internal standard for urine analysis. Standard addition was used for promethazine analysis from serum. Drug to internal standard ratios were linear from 0.25 to 10 micrograms ml-1 in urine. Serum levels were linear from 2 to 10 ng ml-1.


Assuntos
Clorpromazina/urina , Antagonistas dos Receptores Histamínicos H1/urina , Prometazina/urina , Clorpromazina/sangue , Cromatografia Líquida , Etanol/química , Dicloretos de Etileno/química , Hexanos/química , Antagonistas dos Receptores Histamínicos H1/sangue , Humanos , Prometazina/sangue , Padrões de Referência , Espectrometria de Fluorescência , Estereoisomerismo , Ácido Trifluoracético/química
10.
J Pharm Biomed Anal ; 36(1): 197-203, 2004 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-15351066

RESUMO

A new chemiluminescence (CL) method is proposed for the determination of chlorpromazine hydrochloride, which is based on the dichloromethane solvent extraction of ion-pair complex of tetrachloroaurate(III) with chlorpromazine hydrochloride and luminol chemiluminescence detection in a reversed micellar medium formed by the cation surfactant cetyltrimethylammonium bromide in a dichloromethane-cyclohexane (1:1 V/V)-water (0.3 mol/L Na2CO3 buffer solution with the pH of 11.5). The ion-pair complex of tetrachloroaurate(III) with chlorpromazine hydrochloride produced an analytical chemiluminescence signal when it entered the reversed micellar water pool. In the optimum conditions, CL intensities are proportional to concentrations of the studied drug over the range 0.05 approximately 10 microg/mL with a detection limit (DL) of 6 ng/mL. The relative standard deviation (R.S.D.) is 2.6% for 1.25 microg/mL chlorpromazine hydrochloride (n = 11). R.S.D. (precision) of inter-day and intra-day is less than 6%, and accuracy of inter-day and intra-day is satisfactory. The method has been applied to the determination of studied drug in pharmaceutical preparations and biological fluids with satisfactory results.


Assuntos
Clorpromazina/análise , Medições Luminescentes/métodos , Luminol/química , Tecnologia Farmacêutica/métodos , Soluções Tampão , Cloretos/química , Clorpromazina/química , Clorpromazina/urina , Compostos de Ouro/química , Substâncias Luminescentes/química , Medições Luminescentes/instrumentação , Micelas , Padrões de Referência , Solventes/química , Tecnologia Farmacêutica/instrumentação
11.
Forensic Sci Int ; 50(2): 167-77, 1991 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1660844

RESUMO

A simple and sensitive method is described for quantitative analysis of chlorpromazine in blood, serum, urine and tissue homogenate. The chlorpromazine cation radical produced by adding perchloric acid and 2,3-dichloro-5,6-dicyano-p-benzoquinone to the sample can be detected by the ESR method at room temperature. The sensitivity limit is 10 ng, that is, 20 microliters of the solution containing 0.5 microgram chlorpromazine/ml. The time needed for the measurement is within 10 min. The chlorpromazine radical thus produced is very stable; for example, 95% of the radical was observed after 24 h. The advantage of this method is discussed by comparing with the ordinary spectrophotometry which requires the purification of the sample.


Assuntos
Clorpromazina/análise , Clorpromazina/sangue , Clorpromazina/urina , Espectroscopia de Ressonância de Spin Eletrônica , Humanos , Valor Preditivo dos Testes , Espectrofotometria Ultravioleta
12.
Se Pu ; 30(9): 938-42, 2012 Sep.
Artigo em Zh | MEDLINE | ID: mdl-23285977

RESUMO

Based on the phenomenon that each of chlorpromazine (CPZ), promethazine (PMZ), chlorpromazine sulfoxide (CPZSO) and promethazine sulfoxide (PMZSO) could enhance the electrochemiluminescence (ECL) intensity of tris(2,2'-bipyridyl) ruthenium, a novel and sensitive method was proposed for the simultaneous determination of CPZ, PMZ and their main metabolites using capillary electrophoresis (CE) coupled with ECL detection. The influences of several experimental parameters were explored. The optimum experimental conditions were as follows: detection potential of 1. 20 V (Ag/AgCl), 40 mmol/L of phosphate buffer solution (pH 6.5) containing 5 mmol/L tris(2,2'-bipyridyl) ruthenium in ECL detection cell, running buffer solution of 18 mmol/L (pH 4.8), sample injection of 8 s at 11 kV, and separation voltage of 13.5 kV. The detection limits (3sigma) of this method were 8.3 x 10(-7) g/L for CPZ, 7.2 x 10(-6) g/L for PMZ, 1.9 x 10(-5) g/L for CPZSO and 3.7 x 10(-6) g/L for PMZSO. The linear ranges of ECL intensity versus mass concentration of medicaments were 7. 1 x 10(-6) - 6. 3 x 10(-3) g/L for CPZ, 7.5 x 10(-5) - 4.6 x 10(-3) g/L for PMZ, 9.7 x 10(-5) - 3.6 x 10(-3) g/L for CPZSO and 8.1 x 10(-5) - 7.7 x 10(-3) g/L for PMZSO. The relative standard deviations (RSDs) of the four target compounds were not more than 3% for ECL intensity and 1% for migration time. This method has the merits of simplicity, speediness, sensitivity, small sample injection, and free from interference. This method was successfully utilized to directly and simultaneously detect CPZ, PMZ, CPZSO and PMZSO in urine samples of pet dogs.


Assuntos
Clorpromazina/análise , Técnicas Eletroquímicas/métodos , Eletroforese Capilar/métodos , Luminescência , Prometazina/análise , Animais , Clorpromazina/análogos & derivados , Clorpromazina/metabolismo , Clorpromazina/urina , Cães , Prometazina/análogos & derivados , Prometazina/metabolismo , Prometazina/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA