Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Fluoresc ; 33(4): 1661-1671, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36809413

RESUMO

Lower back pain is a universal dilemma leaving a negative effect on both health and life quality. It was found that a fixed dose combination of chlorzoxazone and ibuprofen gave a higher efficiency than analgesic alone in treatment of acute lower back pain. Based on the significant benefit of that combination, a green, sensitive, rapid, direct, and cost-effective method is created for concurrent determination of ibuprofen and chlorzoxazone in presence of 2-amino para chlorophenol (a synthetic precursor and potential impurity of chlorzoxazone) adopting the synchronous spectrofluorimetric technique. Synchronous spectrofluorimetric technique is adopted to avoid the highly overlapped native spectra of both drugs. The synchronous spectrofluorometric method was applied at Δλ = 50 nm, ibuprofen was measured at 227 nm while chlorzoxazone was measured at 282 nm with no hindering from one to another. The various experimental variables affecting the performance of the suggested technique were explored and adjusted. The suggested technique showed good linearity from 0.02 to 0.6 and 0.1 to 5.0 µg/mL for ibuprofen and chlorzoxazone, respectively. The produced detection limits were 0.27 × 10-3 and 0.03, while the quantitation limits were 0.82 × 10-3 and 0.09 µg/mL for ibuprofen and chlorzoxazone, respectively. The suggested approach was successfully applied for the analysis of the studied drugs in the synthetic mixture, different pharmaceutical preparations, and spiked human plasma. The suggested technique was validated with respect to the International Council of Harmonization (ICH) recommendations. The suggested technique was found to be simpler and greener with lower cost compared to the earlier reported methods which required complicated techniques, longer time of analysis, and less safe solvents and reagents. Green profile assessment for the developed method compared with the reported spectrofluorometric method was performed using four assessment tools. These tools confirmed that the recommended technique attained the most possible green parameters, so it could be used as a greener option in routine quality control for analyzing the two drugs in genuine form and pharmaceutical preparations.


Assuntos
Ibuprofeno , Dor Lombar , Humanos , Clorzoxazona/análise , Fluorescência , Preparações Farmacêuticas , Espectrometria de Fluorescência/métodos
2.
J AOAC Int ; 96(4): 723-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24000743

RESUMO

A new, fast, accurate, precise, and sensitive RP-HPLC method for the simultaneous determination of acemetacin and chlorzoxazone has been developed. Response surface methodology with a central composite design was used to optimize the acetonitrile and ammonium acetate percentage in the mobile phase and pH of ammonium acetate. The optimum separation was achieved on a C18 column (250 x 4.6 mm id, 5 microm particle size) using the mobile phase methanol-acetonitrile-0.02 M ammonium acetate, pH 9.4 (25 + 35 + 40, v/v/v) at a flow rate of 1.5 mL/min; UV detection at 270 nm, and cyanocobalamin as an internal standard. This developed method was validated and successfully applied to a coated tablet pharmaceutical preparation.


Assuntos
Anti-Inflamatórios não Esteroides/análise , Clorzoxazona/análise , Cromatografia Líquida de Alta Pressão/métodos , Indometacina/análogos & derivados , Relaxantes Musculares Centrais/análise , Indometacina/análise , Comprimidos
3.
Pharmazie ; 68(1): 19-26, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23444776

RESUMO

Cytochrome P450 enzymes are responsible for the oxidative metabolism of most pharmaceutical compounds. A "cocktail" approach which employs simultaneous administration of a mixture of substrates of CYP enzymes was often used to assess the metabolic activity of multiple P450 forms in one experiment. Phenacetin, coumarin, tolbutamide, chlorzoxazone and testosterone are commonly used as probe substrates to evaluate cytochrome P450 function. An analytical strategy to simultaneously extract and analyze the five probe substrates and their major metabolites by HPLC-DAD was developed. The incubation was done with all the substrates in one step. The ten analytes were extracted simultaneously by solid-phase extraction (SPE) from rat liver microsomes. A C18 analytical column and mobile phase composed of acetonitrile and 0.02% aqueous phosphoric acid were used for the chromatographic separation with DAD detection. Limits of quantification varied between 0.02378 and 0.2361 microg/mL which contributed to quantify all these drugs and metabolites with UV detection. The method is applicable for the modeling and description of pharmacological interactions on rat cytochromes P450 or can be used for in vitro evaluation of cytochromes 1A2, 2A6, 2C11, 2E1 and 3A2.


Assuntos
Analgésicos não Narcóticos/análise , Anticoagulantes/análise , Clorzoxazona/análise , Cumarínicos/análise , Sistema Enzimático do Citocromo P-450/análise , Hipoglicemiantes/análise , Microssomos Hepáticos/enzimologia , Relaxantes Musculares Centrais/análise , Fenacetina/análise , Testosterona/análise , Tolbutamida/análise , Animais , Calibragem , Cromatografia Líquida de Alta Pressão , Meios de Cultura , Técnicas In Vitro , Extração Líquido-Líquido , Controle de Qualidade , Ratos , Padrões de Referência , Reprodutibilidade dos Testes , Espectrofotometria Ultravioleta
4.
J Fluoresc ; 22(2): 779-88, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22068956

RESUMO

A novel, simple, sensitive and selective spectrofluorimetric method was developed for the determination of trace amounts of chlorzoxazone and Ibuprofen in pharmaceutical tablets using optical sensor Eu-Tetracycline HCl doped in sol-gel matrix. The chlorzoxazone or Ibuprofen can remarkably enhance the luminescence intensity of Eu-Tetracycline HCl complex doped in a sol-gel matrix in dimethylformamide (DMF) at pH 9.7 and 6.3, respectively, λ(ex) = 400 nm. The enhancing of luminescence intensity peak of Eu-Tetracycline HCl complex at 617 nm is proportional to the concentration of chlorzoxazone or Ibuprofen a result that suggested profitable application as a simple optical sensor for chlorzoxazone or Ibuprofen assessment. The dynamic ranges found for the determination of chlorzoxazone and Ibuprofen concentration are 5 × 10(-9)-1 × 10(-4) and 1 × 10(-8)-7 × 10(-5) mol L(-1), and the limit of detection (LOD) and quantitation limit of detection (LOQ) are 3.1 × 10(-10), 9.6 × 10(-10) and 5.6 × 10(-10), 1.7 × 10(-9) mol L(-1), respectively.


Assuntos
Clorzoxazona/análise , Dimetilformamida/química , Corantes Fluorescentes/química , Ibuprofeno/análise , Dispositivos Ópticos , Compostos Organometálicos/química , Preparações Farmacêuticas/análise , Espectrometria de Fluorescência/métodos , Tetraciclinas/química , Géis/química , Luminescência , Estrutura Molecular , Comprimidos/química
5.
J Chromatogr Sci ; 46(7): 649-52, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18718143

RESUMO

A simple, rapid, and precise reversed-phase liquid chromatographic method is developed for simultaneous determination of paracetamol, aceclofenac, and chlorzoxazone in their ternary mixtures of commercial pharmaceutical preparation. This method uses a Zorbax SB C18, 250 x 4.6 mm, 5 microm analytical column. Mobile phase is acetonitrile and buffer (40:60, v/v), buffer containing 50 mM orthophosporic acid; pH of the buffer is adjusted to 6 with 10% w/v sodium hydroxide solution. The instrumental settings are at a flow rate of 1 mL/min; the column temperature is 25 degrees C, and detector wavelength is 270 nm. The sample concentrations are measured on weight basis to avoid the internal standard. The method is validated and shown to be linear. The correlation coefficients for paracetamol, aceclofenac, and chlorzoxazone are 0.9981, 0.9990, and 0.9986, respectively. The recovery values for paracetamol, aceclofenac, and chlorzoxazone ranged from 100.7-101.4%, 100.4-101.0%, and 100.5-101.3%, respectively. The relative standard deviation for six replicates is always less than 2%. This HPLC method is successfully applied to the simultaneous quantitative analysis of the title drugs in tablets and can be applied for assay and dissolution test of tablets for the estimation of paracetamol, aceclofenac, and chlorozoxazone in their commercial samples.


Assuntos
Acetaminofen/análise , Clorzoxazona/análise , Cromatografia Líquida de Alta Pressão/métodos , Diclofenaco/análogos & derivados , Diclofenaco/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Braz. J. Pharm. Sci. (Online) ; 59: e20918, 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1429951

RESUMO

Abstract Solubility of pharmaceutical drugs in organic solvents is one of the important parameters to understand the equilibrium concentration of solute-solvent, which helps optimize and design crystallization conditions to obtain the desired product crystals. In the present study, Chlorzoxazone (CHZ) is used as a model pharmaceutical compound to investigate the equilibrium solubility, the influence of solvent and the operating conditions on the shape, and the size distribution. The solubility of CHZ is determined in organic solvents like Isopropanol, Ethanol, and 2-Ethoxyethylacetate, Ethylacetate and Ethyllactate using shake flask method from -5ºC to 60ºC. The solubility of CHZ in these solvents shows an increasing trend as the temperature increases in the following order: ethyllactate + water (0.5+0.5) < ethylacetate < isopropanol < ethanol < 2-ethoxyethylacetate < ethyllactate + water (0.75+0.25). The solvents, isopropanol, ethanol, and ethyl lactate, produce needle-shaped crystals, while 2-ethoxyethylacetate and ethyl acetate tend to produce plate shaped crystals. CHZ crystals obtained from 2-ethoxyethylacetate tend to have plate shaped crystals with a lower aspect ratio and are selected for batch cooling crystallization experiments performed at different cooling rates, and agitation. It is found that the agitation at 300 rpm and the cooling rate 0.2ºC/min produce more uniform crystal size distribution


Assuntos
Solventes/classificação , Clorzoxazona/análise , Cristalização/classificação , Solubilidade , Preparações Farmacêuticas/administração & dosagem
7.
Spectrochim Acta A Mol Biomol Spectrosc ; 205: 376-380, 2018 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-30048941

RESUMO

Traditional Partial Least Squares (PLS) and Advanced Artificial Neural Network (ANN) models were applied for the quantitative determination of paracetamol (PAR) and chlorzoxazone (CZX) together with their process-related impurities namely; 4-aminophenol (AP), 4­chloroacetanilide (AC), 4­nitrophenol (NP), 4­chlorophenol (CP) and 2­amino-4-chlorophenol (ACP). Both models were applied first to full spectrum data then the results were compared to those obtained after wavelength selection using Genetic Algorithm (GA). A 5-level 7-factor experimental design was used giving rise to 25 mixtures containing different proportions of the seven compounds. The calibration set was composed of 15 mixtures while 9 mixtures were used in the validation set to test the predictive ability of the suggested models. The four models PLS, ANN, GA-PLS and GA-ANN were successfully applied for the determination of PAR and CZX in their pure and pharmaceutical dosage form. One way ANOVA was carried out between the developed methods and the official ones for PAR and CZX and no significant difference was found. The four models can be easily applied for the determination of the selected drugs in quality control laboratories lacking expensive HPLC instruments.


Assuntos
Acetaminofen/análise , Clorzoxazona/análise , Contaminação de Medicamentos , Acetaminofen/química , Algoritmos , Análise de Variância , Clorzoxazona/química , Cromatografia Líquida de Alta Pressão , Formas de Dosagem , Análise dos Mínimos Quadrados , Redes Neurais de Computação , Espectrofotometria Ultravioleta
8.
J Chromatogr Sci ; 56(9): 819-827, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29920591

RESUMO

Recently, analytical separation techniques have the potential toward green approaches to reduce the environmental impact. This study focuses on the development of an analytical method for the determination of paracetamol and chlorzoxazone in their pharmaceutical combination. The separation was achieved using a home-made capillary column (0.10 mm i.d. × 200 mm length) filled with porous cross-linked hexyl polymethacrylate as monolithic stationary phase. The method proved to be simple, fast, sensitive, efficient, cost-effective and green approach due to the combination of the amazing properties of a monolithic material and a miniaturized liquid chromatography, which would be considered as a step toward reducing the analytical costs and the environmental impact of chromatographic applications. Both components were detected using a 3-nL nano-UV cell fixed at 270 nm wavelength. The optimized mobile phase was composed of 1% aqueous formic acid solution and acetonitrile at 40:60 ratio, 1.0 µL/min flow rate, 4.0 nL injection volume and 50°C column temperature. Under the optimized conditions, paracetamol and chlorzoxazone have been separated in about 6.5 min with chromatographic resolution of 2.37. The prepared column and the analysis method was fully validated and compared with other reported works. All findings allow to conclude that the prepared column and proposed method are applicable for quality control and routine analysis of the two drugs.


Assuntos
Acetaminofen/análise , Clorzoxazona/análise , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Ácidos Polimetacrílicos/química , Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia de Fase Reversa/instrumentação , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Comprimidos
9.
PLoS One ; 13(10): e0205371, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30304050

RESUMO

Helium, a minor component of natural gas and radioactive minerals, is most commonly used as a carrier in gas chromatography-mass spectrometry (GC-MS). Its scarcity leads to limited availability and higher costs. In this experiment, hydrogen from a safe source of a hydrogen generator was tested as a substitutive carrier gas for the detection of adulterant in traditional Chinese medicine (TCM) and food supplements by GC-MS analysis. We found that the limits of detection (LODs) of using hydrogen were from 10 to 1000 µg/g. The levels of LODs tested among 170 drugs remain the same whether hydrogen or helium was used as a carrier gas with the exception of 7 drugs-benzbromarone, estradiol benzoate, bezafibrate, mefenamic acid, oxymetholone, piperidenafil and cetilistat. The real sample analysis results using hydrogen were as satisfactory as those using helium. In addition, the retention time was shortened after the chromatographic performance was optimized. In summary, it is worth considering hydrogen as a carrier gas due to its affordable costs, energy efficiency, carbon reduction and chromatographic advantages to detect adulterated drugs in TCM and dietary supplement using GC-MS.


Assuntos
Suplementos Nutricionais/análise , Contaminação de Medicamentos/prevenção & controle , Medicamentos de Ervas Chinesas/análise , Hidrogênio/química , Clorzoxazona/análise , Contaminação de Medicamentos/economia , Cromatografia Gasosa-Espectrometria de Massas/métodos , Hélio/química , Hélio/economia , Humanos , Hidrogênio/economia , Limite de Detecção , Oximetolona/análise , Pirimidinonas/análise , Citrato de Sildenafila/análise , Sulfonas/análise
10.
J AOAC Int ; 90(3): 693-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17580621

RESUMO

New, simple, rapid, and precise reversed-phase high-performance liquid chromatographic (LC) methods were developed for the simultaneous determination of chlorzoxazone (CH) and ketoprofen (KT) in binary mixtures and in ternary mixtures containing the CH degradation product, 2-amino-4-chlorophenol (CD). The analytes were separated by LC on a Lichrosphere 60 C18 column (250 x 4 mm, 5 microm). The mobile phases, methanol-water (40:60, v/v) at 1 mL/min and methanol-0.05% phosphoric acid (60:40, v/v, pH 2.81) at 1.5 mL/min, satisfactorily resolved the binary and ternary mixtures, respectively. The UV detector was operated at 280 nm for the determination of CH and at 254 nm for the determination of KT and CD. Linearity, accuracy, and precision were found to be acceptable over the concentration ranges of 20-240 and 5-60 microg/mL for CH and KT, respectively, in the binary mixtures and 50-300, 10-60, and 20-160 microg/mL for CH, KT, and CD, respectively, in the ternary mixtures. The optimized methods proved to be specific, robust, and accurate for the quality control of CH and KT in pharmaceutical preparations.


Assuntos
Química Farmacêutica/métodos , Clorzoxazona/análise , Cromatografia Líquida/métodos , Cetoprofeno/análise , Técnicas de Química Analítica/métodos , Clorzoxazona/química , Cromatografia/métodos , Cromatografia Líquida de Alta Pressão , Concentração de Íons de Hidrogênio , Cetoprofeno/química , Modelos Químicos , Preparações Farmacêuticas , Controle de Qualidade , Reprodutibilidade dos Testes , Comprimidos , Fatores de Tempo
11.
J AOAC Int ; 90(1): 82-93, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17373439

RESUMO

This paper presents a simple, specific, and precise high-performance liquid chromatographic method for the simultaneous determination of paracetamol (PCM), chlorzoxazone (CXZ), and their related impurities in bulk raw materials and solid dosage forms. The mobile phase consisted of water-methanol-glacial acetic acid (60 + 40 + 2, v/v/v). A column containing octadecylsilane chemically bonded to porous silica particles (Spherisorb ODS 1, 25 cm x 4.6 mm, 5 microm) was used as stationary phase. Detection was performed using a variable wavelength ultraviolet-visible detector set at 272 nm for all compounds. Solutions were injected into the chromatograph under isocratic condition at a constant flow rate of 1.2 mL/min. The method was validated according to International Conference on Harmonization requirements and demonstrates good accuracy and precision and a wide linearity range. The method separates PCM, CXZ, and 3 major impurities [4-aminophenol (4AP), 4'-chloracetanilide (4CA), and p-chlorophenol (PCP)] with fair resolution in less than 15 min. The developed method is rapid and sensitive (limit of detection for 4AP, 4CA, and PCP established at 31.25, 39.06, and 65.16 ng/mL, respectively) and, therefore, suitable for quality control and stability studies of these compounds in dosage forms.


Assuntos
Acetamidas/análise , Acetaminofen/análise , Aminofenóis/análise , Clorofenóis/análise , Clorzoxazona/análise , Preparações Farmacêuticas/química , Acetamidas/isolamento & purificação , Acetaminofen/isolamento & purificação , Aminofenóis/isolamento & purificação , Clorofenóis/isolamento & purificação , Clorzoxazona/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Estrutura Molecular , Soluções
12.
Artigo em Inglês | MEDLINE | ID: mdl-27038581

RESUMO

In this work, resolution and quantitation of spectral signals are achieved by several univariate and multivariate techniques. The novel pure component contribution algorithm (PCCA) along with mean centering of ratio spectra (MCR) and the factor based partial least squares (PLS) algorithms were developed for simultaneous determination of chlorzoxazone (CXZ), aceclofenac (ACF) and paracetamol (PAR) in their pure form and recently co-formulated tablets. The PCCA method allows the determination of each drug at its λmax. While, the mean centered values at 230, 302 and 253nm, were used for quantification of CXZ, ACF and PAR, respectively, by MCR method. Partial least-squares (PLS) algorithm was applied as a multivariate calibration method. The three methods were successfully applied for determination of CXZ, ACF and PAR in pure form and tablets. Good linear relationships were obtained in the ranges of 2-50, 2-40 and 2-30µgmL(-1) for CXZ, ACF and PAR, in order, by both PCCA and MCR, while the PLS model was built for the three compounds each in the range of 2-10µgmL(-1). The results obtained from the proposed methods were statistically compared with a reported one. PCCA and MCR methods were validated according to ICH guidelines, while PLS method was validated by both cross validation and an independent data set. They are found suitable for the determination of the studied drugs in bulk powder and tablets.


Assuntos
Acetaminofen/análise , Algoritmos , Clorzoxazona/análise , Diclofenaco/análogos & derivados , Análise Espectral/métodos , Acetaminofen/química , Calibragem , Química Farmacêutica , Clorzoxazona/química , Diclofenaco/análise , Diclofenaco/química , Análise dos Mínimos Quadrados , Padrões de Referência , Análise de Regressão , Reprodutibilidade dos Testes , Soluções , Comprimidos
13.
Guang Pu Xue Yu Guang Pu Fen Xi ; 25(4): 620-3, 2005 Apr.
Artigo em Zh | MEDLINE | ID: mdl-16097701

RESUMO

The present paper is to study ratio spectrophotometry for its application to the assay of compound pharmacy preparations. According to the feature of ratio spectra, the wavelength pair was selected at the peak point or valley point of ratio spectra to establish ratio spectrophotometry for the determination of Co-Chlorzoxazone tablet and injection of caffeine and sodium benzoate. The average recoveries and relative standard deviations for Chlorzoxazone and paracetamol were 100.0% and 1.28%, and 100.0% and 0.84%, respectively; the average recoveries and relative standard deviations for caffeine and sodium benzoate were 99.98% and 0.70%, and 99.91% and 0.78%, respectively. It is concluded that as long as the ratio spectra exhibit at least one peak and one valley, the results are satisfactory.


Assuntos
Química Farmacêutica/métodos , Preparações Farmacêuticas/química , Espectrofotometria Ultravioleta/métodos , Acetaminofen/análise , Acetaminofen/química , Algoritmos , Cafeína/análise , Cafeína/química , Cafeína/normas , Clorzoxazona/análise , Clorzoxazona/química , Preparações Farmacêuticas/análise , Padrões de Referência , Reprodutibilidade dos Testes , Benzoato de Sódio/análise , Benzoato de Sódio/química , Benzoato de Sódio/normas
14.
Toxicol Sci ; 48(2): 189-96, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10353310

RESUMO

The aim of this study was to examine if the drug chlorzoxazone has any influence on the toxicokinetics of acetone and toluene. Chlorzoxazone is mainly metabolized by the same enzyme (Cytochrome P450 2E1) as ethanol and many other organic solvents. Ten male volunteers were exposed to solvent vapor (2 h, 50 watt) in an exposure chamber. Each subject was exposed to acetone only (250 ppm), acetone + chlorzoxazone, toluene (50 ppm) only, toluene + chlorzoxazone, and chlorzoxazone only. Chlorzoxazone (500 mg) was taken as two tablets 1 h prior to solvent exposure. Samples of blood, urine and exhaled air were collected before, during and until 20 h post exposure. The samples were analyzed by head-space gas chromatography (acetone and toluene) and high-performance liquid chromatography (chlorzoxazone, 6-hydroxychlorzoxazone and hippuric acid). The time-concentration curves of acetone and toluene in blood were fitted to one- and four-compartment toxicokinetic models, respectively. Intake of chlorzoxazone was associated with slight but significant increases in the area under the blood concentration-time curve (AUC) and steady state concentration of acetone in blood, along with non significant tendencies to an increased half time in blood and an increased AUC in urine. Except for a delayed excretion of hippuric acid in urine, no effects on the toluene toxicokinetics were seen after chlorzoxazone treatment. Small increases in chlorzoxazone plasma levels were seen after exposure compared to chlorzoxazone alone. These interactions, although statistically significant, seem to be small compared to the interindividual variability on metabolism and toxicokinetics.


Assuntos
Acetona/farmacocinética , Clorzoxazona/farmacologia , Relaxantes Musculares Centrais/farmacologia , Tolueno/farmacocinética , Acetona/análise , Acetona/sangue , Administração por Inalação , Administração Oral , Adulto , Testes Respiratórios , Clorzoxazona/análise , Cromatografia Gasosa , Cromatografia Líquida de Alta Pressão , Interações Medicamentosas , Hipuratos/urina , Humanos , Masculino , Pessoa de Meia-Idade , Tolueno/análise , Tolueno/sangue , Urina/química
15.
Artigo em Inglês | MEDLINE | ID: mdl-12504188

RESUMO

A simple, accurate and sensitive HPLC method for the in vitro determination of 6-hydroxychlorzoxazone and chlorzoxazone in porcine microsome samples is described. Chromatography was performed on a YMC-Pack ODS-AQ column using a mobile phase of 0.05% phosphoric acid pH 3-methanol (60:40, v/v). UV detection was carried out at 287 nm. The detector response was linear over the concentration range 25-2000 ng/ml. This assay produced quick, accurate, and repeatable results.


Assuntos
Clorzoxazona/análogos & derivados , Clorzoxazona/análise , Microssomos/química , Animais , Cromatografia Líquida de Alta Pressão , Padrões de Referência , Espectrofotometria Ultravioleta , Suínos
16.
J Pharm Sci ; 68(7): 910-2, 1979 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-458615

RESUMO

A fluorometric determination for chlorzoxazone was developed based on the intrinsic drug fluorescence in chloroform using excitation and emission wavelengths of 286 and 310 nm, respectively. A calibration curve for chlorzoxazone in chloroform gave a linear working range of 0.027-2.3 microgram/ml (r = 0.9999) with the minimum detectability at 27 ng/ml. The procedure was applied to chlorzoxazone analysis in spiked plasma and urine samples. Minimum detectable drug levels in these samples were 60 and 130 ng/ml, respectively. Data revealed that chlorzoxazone could be determined in plasma and urine even in the presence of 20-fold molar excesses of its major metabolite, 6-hydroxychlorzoxaxone, and acetaminophen. The method also was applicable to chlorzoxazone analysis in a commercial dosage form containing acetaminophen.


Assuntos
Benzoxazóis/análise , Clorzoxazona/análise , Adulto , Clorzoxazona/sangue , Clorzoxazona/urina , Humanos , Masculino , Métodos , Espectrometria de Fluorescência , Comprimidos/análise , Fatores de Tempo
17.
J Pharm Sci ; 68(1): 32-6, 1979 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-758460

RESUMO

High pressure liquid chromatography using reversed-phase and/or ion-pair techniques was used to optimize resolution of aspirin-containing muscle relaxant mixtures as well as other therapeutic agents commonly found in muscle relaxant-analgesic mixtures. The compounds were chromatographed on an octadecylsilane column using methanol--water solvent systems, some of which contained tetrabutylammonium cation as counterion. Mixtures of methocarbamol--aspirin and chlorzoxazone--acetaminophen were selected to demonstrate separation and quantification. The methocarbamol--aspirin mixture was chromatographed with methanol--water (40:60, pH 6.8) containing 0.01 M tetrabutylammonium cation at a flow rate of 2.0 ml/min. The chlorzoxazone--acetaminophen mixture was chromatographed with methanol--water (50:50) at a 2.0 ml/min flow rate. The separation and quantitation of each mixture were achieved in approximately 8 min with accuracy in the 2--3% range.


Assuntos
Analgésicos/análise , Relaxantes Musculares Centrais/análise , Acetaminofen/análise , Aspirina/análise , Clorzoxazona/análise , Cromatografia Líquida de Alta Pressão/métodos , Combinação de Medicamentos , Metocarbamol/análise , Métodos
18.
J Pharm Biomed Anal ; 7(6): 693-8, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2490773

RESUMO

Two spectrophotometric methods have been developed for the simultaneous determination of chlorzoxazone and acetaminophen in their combined dosage forms. No preliminary separation step is required in either method. The first, an absorbance ratio technique using the isoabsorptive point as one of the wavelengths, together with "Q curve" analysis gives accurate and reproducible results for both drugs. The second, a difference spectrophotometric method is based on measurement of absorbance of an alkaline solution relative to that of an acidic solution of identical concentration of the sample at two different wavelengths. The method is suitable for routine analysis of such combinations of the drugs.


Assuntos
Acetaminofen/análise , Clorzoxazona/análise , Combinação de Medicamentos , Reprodutibilidade dos Testes , Espectrofotometria Ultravioleta/métodos , Comprimidos
19.
J Pharm Biomed Anal ; 20(5): 727-35, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10701980

RESUMO

The present work describes a quantitative thin layer procedure for estimating primidone, clorazepate dipotassium and chlorzoxazone in bulk powders and in dosage forms, each in the presence of its degradation product. The method consists of dissolving the drug in ethanol (for primidone), or methanol (for clorazepate dipotassium and chlorzoxazone) and then spotting this solution on a thin layer of silica gel G254. Quantitation is achieved by comparing the areas under the peaks obtained from scanning the thin layer chromatographic plates in a spectrodensitometer.


Assuntos
Anticonvulsivantes/análise , Clorzoxazona/análise , Clorazepato Dipotássico/análise , Primidona/análise , Cápsulas/normas , Densitometria/métodos , Densitometria/normas , Reprodutibilidade dos Testes , Comprimidos/normas
20.
J Pharm Biomed Anal ; 32(6): 1145-8, 2003 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-12907257

RESUMO

A simple, precise and rapid reversed phase HPLC method was developed for the simultaneous estimation of aspirin (AS) and isosorbide 5-mononitrate (ISM) in combined formulation. The method was carried out on a Thermo Quest C18 column using a mixture of water:methanol (water pH adjusted to 3.4 using dilute orthophosphoric acid) and detection was carried out at 215 nm using chlorzoxazone as internal standard. Both the drugs showed linearity in the range of 2-10 microg/ml and limits of quantification was found to be 4 and 40 ng/ml for AS and ISM, respectively.


Assuntos
Aspirina/análise , Cromatografia Líquida de Alta Pressão/métodos , Dinitrato de Isossorbida/análogos & derivados , Dinitrato de Isossorbida/análise , Clorzoxazona/análise , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA