Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
World J Urol ; 38(6): 1563-1568, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31515606

RESUMO

PURPOSE: To evaluate the ablation capacity using two Thulium fiber lasers (TFL) in a porcine kidney model. METHODS: All tissue samples were mounted on a motorized stage for a precise speed of cutting. A continuous wave (cw) TFL and a super pulsed (SP) TFL were used at power settings of 60 and 120 W with 200 and 600 µm laser fibers. After lactate dehydrogenase staining, histological evaluation was performed to measure the vaporization volume (VV), ablation depth (AD), thermo-mechanical damage zones (TMZ), coagulation zones (CZ) and the carbonization grade (CG). RESULTS: At 120 W, no significant differences were seen between 200 and 600 µm fibers utilizing the cw TFL regarding VV (24.6 vs. 28.2 mm3/s), AD (5.6 vs. 5.7 mm), TMZ (0 vs. 0 mm2) and CZ (18.1 vs. 12.3 mm2). Using the SP TFL, no significant differences between both fiber diameters with regard to VV (4 vs. 6.2 mm3/s), AD (2.7 vs. 3.4 mm), TMZ (1 vs. 2.6 mm2) and CZ (3.1 vs. 2.2 mm2) at 120 W were found, respectively. However, the VV of the cw TFL at 60 W was significantly less compared to 120 W using 200 and 600 µm fibers, respectively, whereas the SP TFL did not show significant differences between 60 and 120 W with regard to VV. SP TFL showed a consistently lower CG compared to cw TFL. CONCLUSIONS: This experiment suggests that there is no significant difference using 200 or 600 µm laser fibers in cw or SP TFLs. However, the cw TFL produces a coagulation zone three to five times larger than the SP TFL regardless of the fiber diameter.


Assuntos
Rim/lesões , Rim/cirurgia , Terapia a Laser/efeitos adversos , Terapia a Laser/instrumentação , Fibras Ópticas/efeitos adversos , Túlio , Animais , Desenho de Equipamento , Modelos Animais , Suínos
2.
Am J Otolaryngol ; 40(5): 631-635, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31178283

RESUMO

PURPOSE: To determine the thermal energy damage potential by heat sources, such as endoscopes and fiber optic light cables, in contact with materials commonly placed around an operating room (OR) table. MATERIALS AND METHOD: Injury by xenon and halogen light sources were tested by direct and indirect contact using fiber optic light bundle cables and scopes at light intensities between ranging from Standby to 100%. The scopes had diameters ranging from 2.7 mm to 10 mm and were set at varying angles. The materials tested were surgical drapes, cotton towels, child shirts, child pants, lap sponges, X-ray detectable sponges, and Mayo covers. The damage potential was determined qualitatively by presence of smoking or smell of burning. RESULTS: Permutations involving direct contact were able to cause thermal injury, while permutations involving indirect contact, endoscopes, or halogen lamp were not. The xenon light source with the fiber optic light cable created thermal injury at light intensities of 50%, 75%, and 100%. Time to injury increased as light intensity was decreased. Only the surgical drape, child shorts, and cotton towel showed evidence of burn injury. CONCLUSIONS: This report supports the potential for thermal injury to the patient secondary to fiber optic light sources, although this potential may be limited in extent. The injury risk can be reduced by avoiding direct contact to materials overlying the patient, confirming standby mode or 25% light intensity, and maintaining the endoscope connected to the fiber optic cable at all times.


Assuntos
Queimaduras/etiologia , Endoscópios/efeitos adversos , Luz/efeitos adversos , Salas Cirúrgicas , Fibras Ópticas/efeitos adversos , Segurança do Paciente , Queimaduras/epidemiologia , Desenho de Equipamento , Segurança de Equipamentos , Temperatura Alta/efeitos adversos , Humanos , Doença Iatrogênica , Modelos Teóricos , Medição de Risco , Estados Unidos
3.
Exp Brain Res ; 235(10): 3081-3092, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28744621

RESUMO

In this study, we explored the effects of a longer term application, up to 12 weeks, of photobiomodulation in normal, naïve macaque monkeys. Monkeys (n = 5) were implanted intracranially with an optical fibre device delivering photobiomodulation (red light, 670 nm) to a midline midbrain region. Animals were then aldehyde-fixed and their brains were processed for immunohistochemistry. In general, our results showed that longer term intracranial application of photobiomodulation had no adverse effects on the surrounding brain parenchyma or on the nearby dopaminergic cell system. We found no evidence for photobiomodulation generating an inflammatory glial response or neuronal degeneration near the implant site; further, photobiomodulation did not induce an abnormal activation or mitochondrial stress in nearby cells, nor did it cause an abnormal arrangement of the surrounding vasculature (endothelial basement membrane). Finally, because of our interest in Parkinson's disease, we noted that photobiomodulation had no impact on the number of midbrain dopaminergic cells and the density of their terminations in the striatum. In summary, we found no histological basis for any major biosafety concerns associated with photobiomodulation delivered by our intracranial approach and our findings set a key template for progress onto clinical trial on patients with Parkinson's disease.


Assuntos
Corpo Estriado , Neurônios Dopaminérgicos , Terapia com Luz de Baixa Intensidade/efeitos adversos , Mesencéfalo , Fibras Ópticas/efeitos adversos , Próteses e Implantes/efeitos adversos , Animais , Terapia com Luz de Baixa Intensidade/instrumentação , Macaca fascicularis
4.
Med Sci Monit ; 22: 362-6, 2016 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-26839152

RESUMO

BACKGROUND: To treat moderate to severe acne vulgaris, we developed an optical fiber imported intra-tissue photodynamic therapy: the optical fiber irradiation 5-aminolevulinic acid photodynamic therapy (OFI-ALA-PDT). The aim of this study was to compare the treatment effect and tolerability of OFI-ALA-PDT versus traditional ALA-PDT in the treatment of moderate to severe acne vulgaris. MATERIAL/METHODS: 60 patients with facial acne enrolled into this study were randomly divided into an OFI-ALA-PDT group and a traditional ALA-PDT group, with 30 patients in each group. The difference between these 2 groups was the red light irradiation methods used. In the OFI-ALA-PDT group we used intra-tissue irradiation (import the red light directly into the target lesion with optical fiber) for 5 min, while the traditional ALA-PDT group received whole-face irradiation for 20 min. All patients received 1 irradiation every 7 to 10 days for a total of 6 irradiations. Treatment effects and adverse reactions were recorded after the 4th and 6th irradiation, and at 4, 8, 16 weeks after the entire treatment. RESULTS: After the 4th irradiation, significantly different effective rates were observed in these groups (90.0% for the OFI-ALA-PDT group and 66.7% for the control group). However, no significant difference in effective rate was recorded in the later observations. There were 182 adverse reactions in the OFI-ALA-PDT group and 497 in the control group, which showed a significant difference (P<0.05). CONCLUSIONS: OFI-ALA-PDT showed improved treatment effective rate in the early stage of irradiation, and it had fewer adverse reactions.


Assuntos
Acne Vulgar/tratamento farmacológico , Ácido Aminolevulínico/uso terapêutico , Fibras Ópticas , Fotoquimioterapia , Ácido Aminolevulínico/efeitos adversos , Estudos de Casos e Controles , Seguimentos , Humanos , Fibras Ópticas/efeitos adversos , Fotoquimioterapia/efeitos adversos
5.
Surg Endosc ; 23(8): 1720-3, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19030930

RESUMO

BACKGROUND: Laparoscopy requires a reliable light source to provide adequate visualization. However, thermal energy is produced as a by-product from the optical cable. This study attempts to quantify the degree of possible thermal damage secondary to the fiber-optic light source. METHODS: Using a digital thermometer, temperature measurements were recorded at the tip of optical cables from five different light sources (Karl Storz, Inc., Tuttlingen, Germany). Temperature measurements were recorded with new and old bulbs. The tip of the cable was applied to surgical drapes and the time to charring was recorded. Subsequently, the tip of the optical cable was applied to a porcine model and tissue samples were obtained after varying amounts of time (5, 15, 30, 60, and 90 s). Sections of the damaged tissue were prepared for microscopic evaluation. Parameters for thermal injury included extent of epidermal, dermal, and subcutaneous fat damage and necrosis. The lateral extent and depth of injury were measured. RESULTS: The maximum temperature at the tip of the optical cable varied between 119.5 degrees C and 268.6 degrees C. When surgical drapes were exposed to the tip of the light source, the time to char was 3-6 s. The degree and volume of injury increased with longer exposure times, and significant injury was recorded with the optical cable 3 mm from the skin. CONCLUSIONS: This study demonstrates that the temperature at the tip of the optical light cord can induce extensive damage. The by-product of light, heat, can produce immediate superficial tissue necrosis that can extend into the subcutaneous fat even when the optical tip is not in direct contact with the skin. In addition, our study shows the variation in temperature that exists between light sources and bulb status. Overall, surgeons must realize and respect the potential complications associated with optical technology.


Assuntos
Queimaduras/etiologia , Temperatura Alta/efeitos adversos , Laparoscopia/métodos , Iluminação/efeitos adversos , Fibras Ópticas/efeitos adversos , Animais , Queimaduras/patologia , Feminino , Iluminação/instrumentação , Projetos Piloto , Índice de Gravidade de Doença , Pele/lesões , Pele/patologia , Suínos
6.
J Clin Neurosci ; 16(2): 236-40, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19071023

RESUMO

We prospectively investigated the complications associated with intraparenchymal intracranial pressure (ICP) monitoring using the Camino intracranial pressure device. A fiberoptic ICP monitoring transducer was implanted in 631 patients. About half of the patients (n=303) also received an external ventricular drainage set (EVDS). The durations (mean+/-SD) of ICP monitoring in patients without and with an EVDS were 6.5+/-4.4 and 7.3+/-5.1 days, respectively. Infection occurred in 6 patients with only an ICP transducer (6/328, 1.8%) and 24 patients with an EVDS also (24/303, 7.9%). The duration of monitoring had no effect on infection, whereas the use of an EVDS for more than 9 days increased infection risk by 5.11 times. Other complications included transducer disconnection (2.37%), epidural hematoma (0.47%), contusion (0.47%), defective probe (0.31%), broken transducer (0.31%), dislocation of the fixation screw (0.15%), and intraparenchymal hematoma (0.15%). In conclusion, intraparenchymal ICP monitoring systems can be safely used in patients who either have, or are at risk of developing, increased ICP.


Assuntos
Pressão Intracraniana/fisiologia , Monitorização Fisiológica/instrumentação , Fibras Ópticas/efeitos adversos , Fatores de Risco , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Escala de Coma de Glasgow , Humanos , Lactente , Hipertensão Intracraniana/diagnóstico , Hipertensão Intracraniana/fisiopatologia , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/efeitos adversos , Monitorização Fisiológica/métodos , Estudos Prospectivos , Estudos Retrospectivos , Estatísticas não Paramétricas , Adulto Jovem
8.
Am J Otolaryngol ; 29(3): 171-6, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18439950

RESUMO

PURPOSE: The purpose of the study was to systematically explore the fire and burn risk associated with fiberoptic cables and electrosurgical devices. MATERIALS AND METHODS: A 300-W light source was connected to a standard gray fiberoptic light cable. The end of the cable was either rested atop or buried within a cotton towel or polypropylene drape in the presence or absence of 100% oxygen for up to 10 minutes. A monopolar electrosurgical device set at 1 W, 10 W, or 30 W was tested on a cotton towel or polypropylene drape for a period of 30 seconds. All trials were repeated. RESULTS: Resting the light cable on top of the cotton towel or polypropylene drape with or without oxygen produced no result. Burying the end of the cable within the drape produced a hole in the drape within 15 seconds both with and without oxygen. Burying the end of the cable within the cotton towel produced a yellow discoloration after 2 minutes both with and without oxygen. The monopolar electrosurgical device set at 30 W burned immediately through the polypropylene drape, producing a skin burn. All other trials with monopolar electrocautery produced no result. No flame or fire was produced in any trial. CONCLUSIONS: Fiberoptic cables and electrosurgical generators represent a serious burn risk for surgical patients, with operating room drapes and towels affording only limited protection. Otolaryngologists should be keenly aware of the risks that these devices represent because our specialty uses them frequently.


Assuntos
Queimaduras por Corrente Elétrica/etiologia , Eletrocirurgia/efeitos adversos , Endoscópios/efeitos adversos , Endoscopia/efeitos adversos , Incêndios/estatística & dados numéricos , Fibras Ópticas/efeitos adversos , Roupas de Cama, Mesa e Banho , Queimaduras por Corrente Elétrica/epidemiologia , Eletrocirurgia/instrumentação , Segurança de Equipamentos , Humanos , Incidência , Salas Cirúrgicas , Estudos Retrospectivos
9.
Cardiovasc Interv Ther ; 33(3): 270-276, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28674929

RESUMO

The frequency of a large pressure signal drift (PDs) caused by pressure wire using optical fibers and its effect on fractional flow reserve (FFR)-based decision-making is not clear. We used pressure wires using optical fibers as "workhorse wires" for 95 consecutive lesions. The wire was normalized at the tip of the guiding catheter just before performing the percutaneous coronary intervention (PCI) and was used without re-normalization until the end of the PCI. The drift value at the end of the procedures was evaluated. Four per cent (n = 4) of patients showed a large drift (PD >3 mmHg). Classification discordance between read-out and PD-corrected FFR values was detected in 8 (8%) measurements in total. The decision changed from FFR ≤0.80 to >0.80 in 7 (7%) measurements and vice versa in 1 (1%) measurement. PD showed no effect on decision-making when the FFR read-out value was <0.78 or >0.82. The frequency of large drifts caused by pressure wires using optical fibers was 4%. However, no case showed decision changes when the FFR gray zone was considered.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Fibras Ópticas/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Idoso , Estenose Coronária/fisiopatologia , Estenose Coronária/cirurgia , Vasos Coronários/fisiopatologia , Vasos Coronários/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos
10.
J Neurosurg ; 124(6): 1829-41, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26613166

RESUMO

OBJECT The authors of this study used a newly developed intracranial optical fiber device to deliver near-infrared light (NIr) to the midbrain of 6-hydroxydopamine (6-OHDA)-lesioned rats, a model of Parkinson's disease. The authors explored whether NIr had any impact on apomorphine-induced turning behavior and whether it was neuroprotective. METHODS Two NIr powers (333 nW and 0.16 mW), modes of delivery (pulse and continuous), and total doses (634 mJ and 304 J) were tested, together with the feasibility of a midbrain implant site, one considered for later use in primates. Following a striatal 6-OHDA injection, the NIr optical fiber device was implanted surgically into the midline midbrain area of Wistar rats. Animals were tested for apomorphine-induced rotations, and then, 23 days later, their brains were aldehyde fixed for routine immunohistochemical analysis. RESULTS The results showed that there was no evidence of tissue toxicity by NIr in the midbrain. After 6-OHDA lesion, regardless of mode of delivery or total dose, NIr reduced apomorphine-induced rotations at the stronger, but not at the weaker, power. The authors found that neuroprotection, as assessed by tyrosine hydroxylase expression in midbrain dopaminergic cells, could account for some, but not all, of the observed behavioral improvements; the groups that were associated with fewer rotations did not all necessarily have a greater number of surviving cells. There may have been other "symptomatic" elements contributing to behavioral improvements in these rats. CONCLUSIONS In summary, when delivered at the appropriate power, delivery mode, and dosage, NIr treatment provided both improved behavior and neuroprotection in 6-OHDA-lesioned rats.


Assuntos
Mesencéfalo/fisiopatologia , Mesencéfalo/efeitos da radiação , Transtornos Parkinsonianos/fisiopatologia , Transtornos Parkinsonianos/terapia , Fototerapia/métodos , Animais , Apomorfina/farmacologia , Sobrevivência Celular/fisiologia , Sobrevivência Celular/efeitos da radiação , Agonistas de Dopamina/farmacologia , Neurônios Dopaminérgicos/efeitos dos fármacos , Neurônios Dopaminérgicos/patologia , Neurônios Dopaminérgicos/fisiologia , Neurônios Dopaminérgicos/efeitos da radiação , Relação Dose-Resposta à Radiação , Estudos de Viabilidade , Imuno-Histoquímica , Terapia com Luz de Baixa Intensidade , Masculino , Mesencéfalo/efeitos dos fármacos , Mesencéfalo/patologia , Movimento/efeitos dos fármacos , Movimento/efeitos da radiação , Fibras Ópticas/efeitos adversos , Oxidopamina , Transtornos Parkinsonianos/patologia , Fototerapia/efeitos adversos , Fototerapia/instrumentação , Próteses e Implantes/efeitos adversos , Ratos Wistar , Tirosina 3-Mono-Oxigenase/metabolismo
12.
Int Urol Nephrol ; 47(12): 1947-52, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26438326

RESUMO

PURPOSE: To compare the efficacy and safety of 365- and 550-µm Ho:YAG laser fiber in semirigid ureteroscopic lithotripsy and to identify parameters that may affect laser energy and time during the procedure. METHODS: A database of 111 patients who undergone a semirigid ureteroscopy (SRURS) for ureteral stone lithotripsy was analyzed. A 365-µm core fiber was used in 56 cases, and a multiple-uses 550-µm laser fiber was used in 55 cases. A standard 6.4 W protocol (8 Hz, 0.8 J/pulse) was used in all cases. The association between laser fiber diameter and several preoperative, intraoperative and postoperative parameters was evaluated. RESULTS: Mean stone burden was 54.1 ± 39.1 mm(2), and postoperative stone-free and complication rate was 100.0 and 16.2 %, respectively. The 550-µm laser fiber diameter was significantly associated with lower laser energy (p = 0.01), energy/mm(3) (p = 0.031), number of pulses (p = 0.012), laser time (p = 0.012) and laser time/mm(3) (p = 0.043), while it did not affect postoperative outcomes. The multivariate analysis showed that shorter procedure duration, smaller stone burden and the 550-µm laser fiber were all significant independent predictors for decreased laser energy consumption. CONCLUSION: The 550-µm laser fiber may decrease laser energy and time during SRURS lithotripsy with Ho:YAG laser compared to the 365 µm. Given its lower cost, it may represent the optimal choice for semirigid procedures.


Assuntos
Lasers de Estado Sólido/uso terapêutico , Litotripsia a Laser/instrumentação , Fibras Ópticas , Cálculos Ureterais/terapia , Adulto , Idoso , Feminino , Humanos , Litotripsia a Laser/efeitos adversos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Fibras Ópticas/efeitos adversos , Estudos Retrospectivos , Cálculos Ureterais/patologia , Ureteroscópios
13.
Biomed Tech (Berl) ; 59(1): 19-28, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24197764

RESUMO

Optical stimulation for hearing restoration is developing as an alternative therapy to electrical stimulation. For a more frequency-specific activation of the auditory system, light-guiding fibres need to be inserted into the coiled cochlea. To enable insertion with minimal trauma, glass fibres embedded in silicone were used as models. Thus, glass fibres of varying core/cladding diameter with and without silicon coating (single as well as in bundles) were inserted into a human scala tympani (ST) model. Insertion cochlear model force measurements were performed, and the thinner glass fibres that showed low insertion forces in the model were inserted into cadaveric human temporal bones. Silicone-coated glass fibres with different core/cladding diameters and bundle sizes could be inserted up to a maximum depth of 20 mm. Fibres with a core/cladding diameter of 50/55 µm break during insertion deeper than 7-15 mm into the ST model, whereas thinner fibres (20/25 µm) could be inserted in the model without breakage and in human temporal bones without causing trauma to the inner ear structures. The insertion forces of silicone-coated glass fibres are comparable to those measured with conventional cochlear implant (CI) electrodes. As demonstrated in human temporal bones, a minimal traumatic implantation of an optical CI may be considered feasible.


Assuntos
Cóclea/lesões , Cóclea/fisiopatologia , Implantes Cocleares/efeitos adversos , Fibras Ópticas/efeitos adversos , Fraturas Cranianas/etiologia , Fraturas Cranianas/fisiopatologia , Osso Temporal/fisiopatologia , Cóclea/cirurgia , Implante Coclear/efeitos adversos , Simulação por Computador , Fricção , Humanos , Técnicas In Vitro , Modelos Biológicos , Estresse Mecânico , Osso Temporal/lesões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA