Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Neuroimage ; 237: 118175, 2021 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-34000407

RESUMO

PURPOSE: Susceptibility Weighted Imaging (SWI) has become established in the clinical investigation of stroke, microbleeds, tumor vascularization, calcification and iron deposition, but suffers from a number of shortcomings and artefacts. The goal of this study was to reduce the sensitivity of SWI to strong B1 and B0 inhomogeneities at ultra-high field to generate homogeneous images with increased contrast and free of common artefacts. All steps in SWI processing have been addressed - coil combination, phase unwrapping, image combination over echoes, phase filtering and homogeneity correction - and applied to an efficient bipolar multi-echo acquisition to substantially improve the quality of SWI. PRINCIPAL RESULTS: Our findings regarding the optimal individual processing steps lead us to propose a Contrast-weighted, Laplace-unwrapped, bipolar multi-Echo, ASPIRE-combined, homogeneous, improved Resolution SWI, or CLEAR-SWI. CLEAR-SWI was compared to two other multi-echo SWI methods and standard, single-echo SWI with the same acquisition time at 7 T in 10 healthy volunteers and with single-echo SWI in 13 patients with brain tumors. CLEAR-SWI had improved contrast-to-noise and homogeneity, reduced signal dropout and was not compromised by the artefacts which affected standard SWI in 10 out of 13 cases close to tumors (as assessed by expert raters), as well as generating T2* maps and phase images which can be used for Quantitative Susceptibility Mapping. In a comparison with other multi-echo SWI methods, CLEAR-SWI had the fewest artefacts, highest SNR and generally higher contrast-to-noise. MAJOR CONCLUSIONS: CLEAR-SWI eliminates the artefacts common in standard, single-echo SWI, reduces signal dropouts and improves image homogeneity and contrast-to-noise. Applied clinically, in a study of brain tumor patients, CLEAR-SWI was free of the artefacts which affected standard, single-echo SWI.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Imagem Ecoplanar/normas , Processamento de Imagem Assistida por Computador/normas , Neuroimagem/normas , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
Neuroimage ; 236: 118043, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33857617

RESUMO

Diffusion tensor imaging (DTI) of the spinal cord is technically challenging due to the size of its structure and susceptibility-induced field inhomogeneity, which impedes clinical applications. This study aimed to achieve high-fidelity spinal cord DTI with reasonable SNR and practical acquisition efficiency. Particularly, a distortion-free multi-shot EPI technique, namely point-spread-function encoded EPI (PSF-EPI), was adopted for diffusion imaging of the cervical spinal cord (CSC). The shot number can be reduced to six for sagittal scans through titled-CAIPI acceleration and partial Fourier undersampling, consequently rendering this technique beneficial in clinics. Fifteen healthy volunteers and seven patients with metallic implants underwent sagittal scans using tilted-CAIPI PSF-EPI at 3T. Unsuppressed fat signals were further removed by retrospective water/fat separation using the intrinsic chemical-shift encoded signals. Compared with multi-shot interleaved EPI method, highly accelerated PSF-EPI method provided evidently improved distortion reduction and higher consistency with anatomical references even with metallic implants. Additionally, axial DTI scans using PSF-EPI were also evaluated quantitatively, and the measured DTI metrics are similar to those obtained from the zonal oblique multi-slice EPI (ZOOM-EPI) method and reported values. The high anatomical consistency, practical scan time and quantitative reliability indicate PSF-EPI's clinical potential for CSC diffusion imaging.


Assuntos
Medula Cervical/anatomia & histologia , Medula Cervical/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Imagem Ecoplanar/métodos , Adulto , Imagem de Tensor de Difusão/normas , Imagem Ecoplanar/normas , Humanos
3.
Neuroimage ; 237: 118099, 2021 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-33940144

RESUMO

High-resolution diffusion MRI (dMRI) is a crucial tool in neuroscience studies to detect fine fiber structure, depict complex fiber architecture and analyze cortical anisotropy. However, high-resolution dMRI is limited by its intrinsically low SNR due to diffusion attenuation. A series of techniques have been proposed to improve the SNR performance, but most of them are at the cost of long scan time, which in turn sacrifice the SNR efficiency, especially for large FOV imaging, such as whole-brain imaging. Recently, a combination of 3D multi-slab acquisition and simultaneous multi-slice (SMS) excitation, namely simultaneous multi-slab (SMSlab), has been demonstrated to have potential for high-resolution diffusion imaging with high SNR and SNR efficiency. In our previous work, we have proposed a 3D Fourier encoding and reconstruction framework for SMSlab acquisition. In this study, we extend this 3D k-space framework to diffusion imaging, by developing a novel navigator acquisition strategy and exploring a k-space-based phase correction method. In vivo brain data are acquired using the proposed SMSlab method and compared with a series of different acquisitions, including the traditional 3D multi-slab, 2D SMS and 2D single-shot EPI (ss-EPI) acquisitions. The results demonstrate that SMSlab has a better SNR performance compared with 3D multi-slab and 2D SMS. The detection capacity of fine fiber structures is improved using SMSlab, compared with the low-resolution diffusion imaging using conventional 2D ss-EPI.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/normas , Neuroimagem/métodos , Neuroimagem/normas , Adulto , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Humanos
4.
Neuroimage ; 241: 118435, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34324976

RESUMO

Mapping mesoscopic cortical functional units such as columns or laminae is increasingly pursued by ultra-high field (UHF) functional magnetic resonance imaging (fMRI). The most popular approach for high-resolution fMRI is currently gradient-echo (GE) blood oxygenation level-dependent (BOLD) fMRI. However, its spatial accuracy is reduced due to its sensitivity to draining vessels, including pial veins, whereas spin-echo (SE) BOLD signal is expected to have higher spatial accuracy, albeit with lower sensitivity than the GE-BOLD signal. Here, we introduce a new double spin-echo (dSE) echo-planar imaging (EPI) method to improve the sensitivity of SE-BOLD contrast by averaging two spin-echoes using three radiofrequency pulses. Human fMRI experiments were performed with slices perpendicular to the central sulcus between motor and sensory cortices at 7 T during fist-clenching with touching. First, we evaluated the feasibility of single-shot dSE-EPI for BOLD fMRI with 1.5 mm isotropic resolution and found that dSE-BOLD fMRI has higher signal-to-noise ratio (SNR), temporal SNR (tSNR), and higher functional sensitivity than conventional SE-BOLD fMRI. Second, to investigate the laminar specificity of dSE-BOLD fMRI, we implemented a multi-shot approach to achieve 0.8-mm isotropic resolution with sliding-window reconstruction. Unlike GE-BOLD fMRI, the cortical profile of dSE-BOLD fMRI peaked at ~ 1.0 mm from the surface of the primary motor and sensory cortices, demonstrating an improvement of laminar specificity in humans over GE-BOLD fMRI. The proposed multi-shot dSE-EPI method is viable for high spatial resolution UHF-fMRI studies in the pursuit of resolving mesoscopic functional units.


Assuntos
Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/metabolismo , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Processamento de Imagem Assistida por Computador/normas , Adulto , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Masculino , Reprodutibilidade dos Testes
5.
Neuroimage ; 236: 118082, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33882349

RESUMO

Recent methodological advances in MRI have enabled substantial growth in neuroimaging studies of non-human primates (NHPs), while open data-sharing through the PRIME-DE initiative has increased the availability of NHP MRI data and the need for robust multi-subject multi-center analyses. Streamlined acquisition and analysis protocols would accelerate and improve these efforts. However, consensus on minimal standards for data acquisition protocols and analysis pipelines for NHP imaging remains to be established, particularly for multi-center studies. Here, we draw parallels between NHP and human neuroimaging and provide minimal guidelines for harmonizing and standardizing data acquisition. We advocate robust translation of widely used open-access toolkits that are well established for analyzing human data. We also encourage the use of validated, automated pre-processing tools for analyzing NHP data sets. These guidelines aim to refine methodological and analytical strategies for small and large-scale NHP neuroimaging data. This will improve reproducibility of results, and accelerate the convergence between NHP and human neuroimaging strategies which will ultimately benefit fundamental and translational brain science.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética/normas , Neuroimagem/normas , Animais , Encéfalo/anatomia & histologia , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Neuroimagem Funcional/métodos , Neuroimagem Funcional/normas , Macaca mulatta , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Reprodutibilidade dos Testes
6.
Hum Brain Mapp ; 42(13): 4205-4223, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34156132

RESUMO

Echo planar imaging (EPI) is widely used in functional and diffusion-weighted MRI, but suffers from significant geometric distortions in the phase encoding direction caused by inhomogeneities in the static magnetic field (B0 ). This is a particular challenge for EPI at very high field (≥7 T), as distortion increases with higher field strength. A number of techniques for distortion correction exist, including those based on B0 field mapping and acquiring EPI scans with opposite phase encoding directions. However, few quantitative comparisons of distortion compensation methods have been performed using human EPI data, especially at very high field. Here, we compared distortion compensation using B0 field maps and opposite phase encoding scans in two different software packages (FSL and AFNI) applied to 7 T gradient echo (GE) EPI data from 31 human participants. We assessed distortion compensation quality by quantifying alignment to anatomical reference scans using Dice coefficients and mutual information. Performance between FSL and AFNI was equivalent. In our whole-brain analyses, we found superior distortion compensation using GE scans with opposite phase encoding directions, versus B0 field maps or spin echo (SE) opposite phase encoding scans. However, SE performed better when analyses were limited to ventromedial prefrontal cortex, a region with substantial dropout. Matching the type of opposite phase encoding scans to the EPI data being corrected (e.g., SE-to-SE) also yielded better distortion correction. While the ideal distortion compensation approach likely varies depending on methodological differences across experiments, this study provides a framework for quantitative comparison of different distortion compensation methods.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/fisiopatologia , Imagem Ecoplanar , Neuroimagem Funcional , Adulto , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Família , Feminino , Neuroimagem Funcional/métodos , Neuroimagem Funcional/normas , Humanos , Masculino , Pessoa de Meia-Idade , Transtornos Psicóticos/diagnóstico por imagem , Transtornos Psicóticos/fisiopatologia , Esquizofrenia/diagnóstico por imagem , Esquizofrenia/fisiopatologia
7.
Hum Brain Mapp ; 42(9): 2833-2850, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-33729637

RESUMO

Looping Star is a near-silent, multi-echo, 3D functional magnetic resonance imaging (fMRI) technique. It reduces acoustic noise by at least 25dBA, with respect to gradient-recalled echo echo-planar imaging (GRE-EPI)-based fMRI. Looping Star has successfully demonstrated sensitivity to the cerebral blood-oxygen-level-dependent (BOLD) response during block design paradigms but has not been applied to event-related auditory perception tasks. Demonstrating Looping Star's sensitivity to such tasks could (a) provide new insights into auditory processing studies, (b) minimise the need for invasive ear protection, and (c) facilitate the translation of numerous fMRI studies to investigations in sound-averse patients. We aimed to demonstrate, for the first time, that multi-echo Looping Star has sufficient sensitivity to the BOLD response, compared to that of GRE-EPI, during a well-established event-related auditory discrimination paradigm: the "oddball" task. We also present the first quantitative evaluation of Looping Star's test-retest reliability using the intra-class correlation coefficient. Twelve participants were scanned using single-echo GRE-EPI and multi-echo Looping Star fMRI in two sessions. Random-effects analyses were performed, evaluating the overall response to tones and differential tone recognition, and intermodality analyses were computed. We found that multi-echo Looping Star exhibited consistent sensitivity to auditory stimulation relative to GRE-EPI. However, Looping Star demonstrated lower test-retest reliability in comparison with GRE-EPI. This could reflect differences in functional sensitivity between the techniques, though further study is necessary with additional cognitive paradigms as varying cognitive strategies between sessions may arise from elimination of acoustic scanner noise.


Assuntos
Córtex Auditivo/fisiologia , Percepção Auditiva/fisiologia , Discriminação Psicológica/fisiologia , Neuroimagem Funcional/normas , Imageamento por Ressonância Magnética/normas , Adulto , Córtex Auditivo/diagnóstico por imagem , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Feminino , Neuroimagem Funcional/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Ruído
8.
Hum Brain Mapp ; 42(13): 4144-4154, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-30761676

RESUMO

Advanced perfusion-weighted imaging (PWI) methods that combine gradient echo (GE) and spin echo (SE) data are important tools for the study of brain tumours. In PWI, single-shot, EPI-based methods have been widely used due to their relatively high imaging speed. However, when used with increasing spatial resolution, single-shot EPI methods often show limitations in whole-brain coverage for multi-contrast applications. To overcome this limitation, this work employs a new version of EPI with keyhole (EPIK) to provide five echoes: two with GEs, two with mixed GESE and one with SE; the sequence is termed "GESE-EPIK." The performance of GESE-EPIK is evaluated against its nearest relative, EPI, in terms of the temporal signal-to-noise ratio (tSNR). Here, data from brain tumour patients were acquired using a hybrid 3T MR-BrainPET scanner. GESE-EPIK resulted in reduced susceptibility artefacts, shorter TEs for the five echoes and increased brain coverage when compared to EPI. Moreover, compared to EPI, EPIK achieved a comparable tSNR for the first and second echoes and significantly higher tSNR for other echoes. A new method to obtain multi-echo GE and SE data with shorter TEs and increased brain coverage is demonstrated. As proposed here, the workflow can be shortened and the integration of multimodal clinical MR-PET studies can be facilitated.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Imagem Ecoplanar , Processamento de Imagem Assistida por Computador , Imagem de Perfusão , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Humanos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Imagem Multimodal/métodos , Imagem Multimodal/normas , Imagem de Perfusão/métodos , Imagem de Perfusão/normas , Tomografia por Emissão de Pósitrons/métodos , Tomografia por Emissão de Pósitrons/normas
9.
Neuroimage ; 221: 117170, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32682096

RESUMO

PURPOSE: A distortion correction method for single-shot EPI was proposed. Point-spread-function encoded EPI (PSF-EPI) images were used as the references to correct traditional EPI images based on deep neural network. THEORY AND METHODS: The PSF-EPI method can obtain distortion-free echo planar images. In this study, a 2D U-net based network was trained to achieve the distortion correction of single-shot EPI (SS-EPI) images, using PSF-EPI images as targets in the training stage. Anatomical T2W-TSE images were also fed into the network to improve the quality of the results. The applications in diffusion-weighted images were used as examples in this work. The network was trained on data acquired on healthy volunteers and tested on data of both healthy volunteers and patients. The corrected EPI images from the proposed method were also compared with those from field-mapping and top-up based distortion correction methods. RESULTS: Experimental results showed that the proposed method can correct for EPI distortions better than both the field-mapping and top-up based methods, and the results were close to the distortion-free images from PSF-EPI. Additionally, inclusion of T2W-TSE images helped improve distortion correction of the SS-EPI images without contaminating the output noticeably. The experiments with patients and different MRI platforms demonstrated the generalization feasibility of the proposed method preliminarily. CONCLUSION: Through the correction of diffusion-weighted images, the proposed deep-learning based method was demonstrated to have the feasibility to correct for the distortion of EPI images.


Assuntos
Encéfalo/diagnóstico por imagem , Aprendizado Profundo , Imagem de Difusão por Ressonância Magnética/normas , Imagem Ecoplanar/normas , Modelos Teóricos , Neuroimagem/normas , Adulto , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Humanos , Neuroimagem/métodos
10.
Neuroimage ; 208: 116434, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31812715

RESUMO

Functional imaging with sub-millimeter spatial resolution is a basic requirement for assessing functional MRI (fMRI) responses across different cortical depths and is used extensively in the emerging field of laminar fMRI. Such studies seek to investigate the detailed functional organization of the brain and may develop to a new powerful tool for human neuroscience. However, several studies have shown that measurement of laminar fMRI responses can be biased by the image acquisition and data processing strategies. In this work, measurements with three different gradient-echo EPI BOLD fMRI protocols with a voxel size down to 650 â€‹µm isotropic were performed at 9.4 â€‹T. We estimated how prospective motion correction can help to improve spatial accuracy by reducing the number of spatial resampling steps in postprocessing. In addition, we demonstrate key requirements for accurate geometric distortion correction to ensure that distortion correction maps are properly aligned to the functional data and that strong variations of distortions near large veins can lead to signal overlays which cannot be corrected for during postprocessing. Furthermore, this study illustrates the spatial extent of bias induced by pial and other larger veins in laminar BOLD experiments. Since these issues under investigation affect studies performed with more conventional spatial resolutions, the methods applied in this work may also help to improve the understanding of the BOLD signal more broadly.


Assuntos
Córtex Cerebral , Veias Cerebrais , Imagem Ecoplanar/normas , Neuroimagem Funcional/normas , Processamento de Imagem Assistida por Computador/normas , Adulto , Córtex Cerebral/anatomia & histologia , Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/fisiologia , Movimentos da Cabeça/fisiologia , Humanos , Percepção Visual/fisiologia , Adulto Jovem
11.
Neuroimage ; 221: 117172, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32682095

RESUMO

Post-mortem diffusion MRI (dMRI) enables acquisitions of structural imaging data with otherwise unreachable resolutions - at the expense of longer scanning times. These data are typically acquired using highly segmented image acquisition strategies, thereby resulting in an incomplete signal decay before the MRI encoding continues. Especially in dMRI, with low signal intensities and lengthy contrast encoding, such temporal inefficiency translates into reduced image quality and longer scanning times. This study introduces Multi Echo (ME) acquisitions to dMRI on a human MRI system - a time-efficient approach, which increases SNR (Signal-to-Noise Ratio) and reduces noise bias for dMRI images. The benefit of the introduced ME-dMRI method was validated using numerical Monte Carlo simulations and showcased on a post-mortem brain of a wild chimpanzee. The proposed Maximum Likelihood Estimation echo combination results in an optimal SNR without detectable signal bias. The combined strategy comes at a small price in scanning time (here 30% additional) and leads to a substantial SNR increase (here white matter: ~ 1.6x, equivalent to 2.6 averages, grey matter: ~ 1.9x, equivalent to 3.6 averages) and a general reduction of the noise bias.


Assuntos
Imagem de Difusão por Ressonância Magnética/normas , Imagem Ecoplanar/normas , Substância Cinzenta/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/normas , Neuroimagem/normas , Substância Branca/diagnóstico por imagem , Animais , Autopsia , Simulação por Computador , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Método de Monte Carlo , Neuroimagem/métodos , Pan troglodytes , Reprodutibilidade dos Testes , Razão Sinal-Ruído
12.
Neuroimage ; 216: 116861, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32305565

RESUMO

Over the recent years, significant advances in Spin-Echo (SE) Echo-Planar (EP) Diffusion MRI (dMRI) have enabled improved fiber tracking conspicuity in the human brain. At the same time, pushing the spatial resolution and using higher b-values inherently expose the acquired images to further eddy-current-induced distortion and blurring. Recently developed data-driven correction techniques, capable of significantly mitigating these defects, are included in the reconstruction pipelines developed for the Human Connectome Project (HCP) driven by the NIH BRAIN initiative. In this case, however, corrections are derived from the original diffusion-weighted (DW) magnitude images affected by distortion and blurring. Considering the complexity of k-space deviations in the presence of time varying high spatial order eddy currents, distortion and blurring may not be fully reversed when relying on magnitude DW images only. An alternative approach, consisting of iteratively reconstructing DW images based on the actual magnetic field spatiotemporal evolution measured with a magnetic field monitoring camera, has been successfully implemented at 3T in single band dMRI (Wilm et al., 2017, 2015). In this study, we aim to demonstrate the efficacy of this eddy current correction method in the challenging context of HCP-style multiband (MB â€‹= â€‹2) dMRI protocol. The magnetic field evolution was measured during the EP-dMRI readout echo train with a field monitoring camera equipped with 16 19F NMR probes. The time variation of 0th, 1st and 2nd order spherical field harmonics were used to reconstruct DW images. Individual DW images reconstructed with and without field correction were compared. The impact of eddy current correction was evaluated by comparing the corresponding direction-averaged DW images and fractional anisotropy (FA) maps. 19F field monitoring data confirmed the existence of significant field deviations induced by the diffusion-encoding gradients, with variations depending on diffusion gradient amplitude and direction. In DW images reconstructed with the field correction, residual aliasing artifacts were reduced or eliminated, and when high b-values were applied, better gray/white matter delineation and sharper gyri contours were observed, indicating reduced signal blurring. The improvement in image quality further contributed to sharper contours and better gray/white matter delineation in mean DW images and FA maps. In conclusion, we demonstrate that up-to-2nd-order-eddy-current-induced field perturbation in multiband, in-plane accelerated HCP-style dMRI acquisition at 7T can be corrected by integrating the measured field evolution in image reconstruction.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/normas , Imagem Ecoplanar/normas , Processamento de Imagem Assistida por Computador/normas , Campos Magnéticos , Neuroimagem/normas , Adulto , Artefatos , Conectoma , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neuroimagem/métodos , Projetos Piloto , Estudo de Prova de Conceito
13.
Hum Brain Mapp ; 41(3): 797-814, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31692177

RESUMO

Resting-state functional magnetic resonance imaging (rsfMRI) is a promising task-free functional imaging approach, which may complement or replace task-based fMRI (tfMRI) in patients who have difficulties performing required tasks. However, rsfMRI is highly sensitive to head movement and physiological noise, and validation relative to tfMRI and intraoperative electrocortical mapping is still necessary. In this study, we investigate (a) the feasibility of real-time rsfMRI for presurgical mapping of eloquent networks with monitoring of data quality in patients with brain tumors and (b) rsfMRI localization of eloquent cortex compared with tfMRI and intraoperative electrocortical stimulation (ECS) in retrospective analysis. Five brain tumor patients were studied with rsfMRI and tfMRI on a clinical 3T scanner using MultiBand(8)-echo planar imaging (EPI) with repetition time: 400 ms. Moving-averaged sliding-window correlation analysis with regression of motion parameters and signals from white matter and cerebrospinal fluid was used to map sensorimotor and language resting-state networks. Data quality monitoring enabled rapid optimization of scan protocols, early identification of task noncompliance, and head movement-related false-positive connectivity to determine scan continuation or repetition. Sensorimotor and language resting-state networks were identifiable within 1 min of scan time. The Euclidean distance between ECS and rsfMRI connectivity and task-activation in motor cortex, Broca's, and Wernicke's areas was 5-10 mm, with the exception of discordant rsfMRI and ECS localization of Wernicke's area in one patient due to possible cortical reorganization and/or altered neurovascular coupling. This study demonstrates the potential of real-time high-speed rsfMRI for presurgical mapping of eloquent cortex with real-time data quality control, and clinically acceptable concordance of rsfMRI with tfMRI and ECS localization.


Assuntos
Mapeamento Encefálico/normas , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Córtex Cerebral/diagnóstico por imagem , Imagem de Tensor de Difusão/normas , Imagem Ecoplanar/normas , Eletrocorticografia/normas , Rede Nervosa/diagnóstico por imagem , Cuidados Pré-Operatórios , Adulto , Mapeamento Encefálico/métodos , Córtex Cerebral/fisiologia , Imagem de Tensor de Difusão/métodos , Imagem Ecoplanar/métodos , Estimulação Elétrica/métodos , Eletrocorticografia/métodos , Estudos de Viabilidade , Feminino , Humanos , Monitorização Neurofisiológica Intraoperatória/métodos , Monitorização Neurofisiológica Intraoperatória/normas , Idioma , Masculino , Pessoa de Meia-Idade , Rede Nervosa/fisiologia , Córtex Sensório-Motor/diagnóstico por imagem , Córtex Sensório-Motor/fisiologia
14.
Neuroimage ; 189: 159-170, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30593904

RESUMO

Gradient echo echo-planar imaging (GE EPI) is used for most fMRI studies but can suffer substantially from image distortions and BOLD sensitivity (BS) loss due to susceptibility-induced magnetic field inhomogeneities. While there are various post-processing methods for correcting image distortions, signal dropouts cannot be recovered and therefore need to be addressed at the data acquisition stage. Common approaches for reducing susceptibility-related BS loss in selected brain areas are: z-shimming, inverting the phase encoding (PE) gradient polarity, optimizing the slice tilt and increasing spatial resolution. The optimization of these parameters can be based on atlases derived from multiple echo-planar imaging (EPI) acquisitions. However, this requires resource and time, which imposes a practical limitation on the range over which parameters can be optimised meaning that the chosen settings may still be sub-optimal. To address this issue, we have developed an automated method that can be used to optimize across a large parameter space. It is based on numerical signal simulations of the BS loss predicted by physical models informed by a large database of magnetic field (B0) maps acquired on a broad cohort of participants. The advantage of our simulation-based approach compared to previous methods is that it saves time and expensive measurements and allows for optimizing EPI protocols by incorporating a broad range of factors, including different resolutions, echo times or slice orientations. To verify the numerical optimisation, results are compared to those from an earlier study and to experimental BS measurements carried out in six healthy volunteers.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem Ecoplanar/normas , Neuroimagem/normas , Adulto , Imagem Ecoplanar/métodos , Humanos , Neuroimagem/métodos , Reprodutibilidade dos Testes
15.
Neuroimage ; 168: 71-87, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28602943

RESUMO

Functional MRI (fMRI) at 7T and above provides improved Signal-to-Noise Ratio and Contrast-to-Noise Ratio compared to 3T acquisitions. In addition to the beneficial effects on spin polarization and magnetization of deoxyhemoglobin, the increased applied field also further magnetizes air and tissue. While the magnets themselves typically provide a static B0 field with sufficient spatial homogeneity, the diamagnetism of tissue and the paramagnetism of air causes local field deviations inside the human head. These spatially-varying field offsets (ΔB0) cause image artifacts, especially in single shot EPI, including geometric distortion, signal dropout, and blurring. These effects are particularly strong near air-tissue interfaces such as the frontal sinus, and ear canals. Furthermore, if the field offsets are dynamically modulated through physiological processes such as respiration or motion, then the effect on the image time-series can be even more problematic. While post-processing methods have been developed to mitigate these effects, the ideal solution would be to reduce the ΔB0 variations at their source. Typically 7T scanners contain 2nd and some 3rd order spherical harmonic shim coil terms to cancel static ΔB0 variations of low spatial order. In this article, we will motivate the need for improved, higher-order compensation for B0 inhomogeneity and potentially add dynamic control of these fields. We discuss and compare several promising hardware approaches for static and dynamic B0 shimming using either higher-order spherical harmonic shim coils or multi-coil shim arrays as well as passive shimming approaches, and active variants such and adaptive current networks.


Assuntos
Artefatos , Encéfalo/diagnóstico por imagem , Imagem Ecoplanar , Neuroimagem Funcional , Imagem Ecoplanar/instrumentação , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Neuroimagem Funcional/instrumentação , Neuroimagem Funcional/métodos , Neuroimagem Funcional/normas , Humanos
16.
Neuroimage ; 168: 321-331, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-27397624

RESUMO

We propose a method to calculate field maps from the phase of each EPI in an fMRI time series. These field maps can be used to correct the corresponding magnitude images for distortion caused by inhomogeneity in the static magnetic field. In contrast to conventional static distortion correction, in which one 'snapshot' field map is applied to all subsequent fMRI time points, our method also captures dynamic changes to B0 which arise due to motion and respiration. The approach is based on the assumption that the non-B0-related contribution to the phase measured by each radio-frequency coil, which is dominated by the coil sensitivity, is stable over time and can therefore be removed to yield a field map from EPI. Our solution addresses imaging with multi-channel coils at ultra-high field (7T), where phase offsets vary rapidly in space, phase processing is non-trivial and distortions are comparatively large. We propose using dual-echo gradient echo reference scan for the phase offset calculation, which yields estimates with high signal-to-noise ratio. An extrapolation method is proposed which yields reliable estimates for phase offsets even where motion is large and a tailored phase unwrapping procedure for EPI is suggested which gives robust results in regions with disconnected tissue or strong signal decay. Phase offsets are shown to be stable during long measurements (40min) and for large head motions. The dynamic distortion correction proposed here is found to work accurately in the presence of large motion (up to 8.1°), whereas a conventional method based on single field map fails to correct or even introduces distortions (up to 11.2mm). Finally, we show that dynamic unwarping increases the temporal stability of EPI in the presence of motion. Our approach can be applied to any EPI measurements without the need for sequence modification.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem Ecoplanar/métodos , Neuroimagem Funcional/métodos , Processamento de Imagem Assistida por Computador/métodos , Adulto , Encéfalo/fisiologia , Imagem Ecoplanar/instrumentação , Imagem Ecoplanar/normas , Feminino , Neuroimagem Funcional/instrumentação , Neuroimagem Funcional/normas , Humanos , Processamento de Imagem Assistida por Computador/normas , Masculino , Imagens de Fantasmas
17.
Neuroimage ; 168: 332-344, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28506874

RESUMO

Functional MRI at ultra-high magnetic fields (≥ 7T) provides the opportunity to probe columnar and laminar processing in the human brain in vivo at sub-millimeter spatial scales. However, fMRI data only indirectly reflects the neuronal laminar profile due to a bias to ascending and pial veins inherent in gradient- and spin-echo BOLD fMRI. In addition, accurate delineation of the cortical depths is difficult, due to the relatively large voxel sizes and lack of sufficient tissue contrast in the functional images. In conventional depth-dependent fMRI studies, anatomical and functional data are acquired with different image read-out modules, the fMRI data are distortion-corrected and vascular biases are accounted for by subtracting the depth-dependent activation profiles of different stimulus conditions. In this study, using high-resolution gradient-echo fMRI data (0.7 mm isotropic) of the human visual cortex, we propose instead, that depth-dependent functional information is best preserved if data analysis is performed in the original functional data space. To achieve this, we acquired anatomical images with high tissue contrast and similar distortion to the functional images using multiple inversion-recovery time EPI, thereby eliminating the need to un-distort the fMRI data. We demonstrate higher spatial accuracy for the cortical layer definitions of this approach as compared to the more conventional approach using MP2RAGE anatomy. In addition, we provide theoretical arguments and empirical evidence that vascular biases can be better accounted for using division instead of subtraction of the depth-dependent profiles. Finally, we show that the hemodynamic response of grey matter has relatively stronger post-stimulus undershoot than the pial vein voxels. In summary, we show that the choice of fMRI data acquisition and processing can impact observable differences in the cortical depth profiles and present evidence that cortical depth-dependent modulation of the BOLD signal can be resolved using gradient-echo imaging.


Assuntos
Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/fisiologia , Imagem Ecoplanar/métodos , Neuroimagem Funcional/métodos , Adulto , Córtex Cerebral/anatomia & histologia , Imagem Ecoplanar/normas , Feminino , Neuroimagem Funcional/normas , Humanos , Masculino , Córtex Visual/anatomia & histologia , Córtex Visual/diagnóstico por imagem , Córtex Visual/fisiologia
18.
Neuroimage ; 176: 404-416, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29738911

RESUMO

Accelerated functional Magnetic Resonance Imaging (fMRI) with 'multiband' protocols is now relatively widespread. These protocols can be used to dramatically reduce the repetition time (TR) and produce a time-series sampled at a higher temporal resolution, which may produce benefits in the statistical methods typically used to analyse fMRI data. We tested the effects of higher temporal resolutions for fMRI on statistical outcome measures in a comprehensive manner on two different MRI scanner platforms. Spatial resolution was maintained at a constant of 3 mm isotropic voxels, and an in-plane acceleration factor of 2 was used for all experiments. Experiment 1 tested a range of acceleration factors (1-6) against a standard EPI protocol on a single composite task that mapped a number of basic sensory, motor, and cognitive networks. Experiment 2 compared the standard protocol with acceleration factors of 2 and 3 on both resting-state and two task paradigms (an N-back task, and faces/places task), with a number of different analysis approaches. Results from experiment 1 showed modest but relatively inconsistent effects of the higher sampling rate on statistical outcome measures. Experiment 2 showed strong benefits of the multiband protocols on results derived from resting-state data, but more varied effects on results from the task paradigms. Notably, the multiband protocols were superior when Multi-Voxel Pattern Analysis was used to interrogate the faces/places data, but showed less benefit in conventional General Linear Model analyses of the same data. In general, ROI-derived measures of statistical effects benefitted only modestly from higher sampling resolution, with greater effects seen when using a measure of the top range of statistical values. Across both experiments, results from the two scanner platforms were broadly comparable. The statistical benefits of high temporal resolution fMRI with multiband protocols may therefore depend on a number of factors, including the nature of the investigation (resting-state vs. task-based), the experimental design, the particular statistical outcome measure, and the type of analysis used.


Assuntos
Córtex Cerebral/fisiologia , Interpretação Estatística de Dados , Neuroimagem Funcional/normas , Processamento de Imagem Assistida por Computador/normas , Imageamento por Ressonância Magnética/normas , Projetos de Pesquisa , Adulto , Córtex Cerebral/diagnóstico por imagem , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Feminino , Neuroimagem Funcional/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Memória de Curto Prazo/fisiologia , Reconhecimento Visual de Modelos/fisiologia , Adulto Jovem
19.
Neuroimage ; 168: 490-498, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28027961

RESUMO

Presurgical planning with fMRI benefits from increased reliability and the possibility to reduce measurement time introduced by using ultra-high field. Echo-planar imaging suffers, however, from geometric distortions which scale with field strength and potentially give rise to clinically significant displacement of functional activation. We evaluate the effectiveness of a dynamic distortion correction (DDC) method based on unmodified single-echo EPI in the context of simulated presurgical planning fMRI at 7T and compare it with static distortion correction (SDC). The extent of distortion in EPI and activation shifts are investigated in a group of eleven patients with a range of neuropathologies who performed a motor task. The consequences of neglecting to correct images for susceptibility-induced distortions are assessed in a clinical context. It was possible to generate time series of EPI-based field maps which were free of artifacts in the eloquent brain areas relevant to presurgical fMRI, despite the presence of signal dropouts caused by pathologies and post-operative sites. Distortions of up to 5.1mm were observed in the primary motor cortex in raw EPI. These were accurately corrected with DDC and slightly less accurately with SDC. The dynamic nature of distortions in UHF clinical fMRI was demonstrated via investigation of temporal variation in voxel shift maps, confirming the potential inadequacy of SDC based on a single reference field map, particularly in the vicinity of pathologies or in the presence of motion. In two patients, the distortion correction was potentially clinically significant in that it might have affected the localization or interpretation of activation and could thereby have influenced the treatment plan. Distortion correction is shown to be effective and clinically relevant in presurgical planning at 7T.


Assuntos
Mapeamento Encefálico/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Transtornos Cerebrovasculares/diagnóstico por imagem , Imagem Ecoplanar/métodos , Processamento de Imagem Assistida por Computador/métodos , Córtex Motor/diagnóstico por imagem , Adulto , Artefatos , Mapeamento Encefálico/normas , Neoplasias Encefálicas/cirurgia , Transtornos Cerebrovasculares/cirurgia , Imagem Ecoplanar/normas , Feminino , Humanos , Processamento de Imagem Assistida por Computador/normas , Masculino , Pessoa de Meia-Idade , Córtex Motor/fisiologia , Procedimentos Neurocirúrgicos , Cuidados Pré-Operatórios
20.
Neuroimage ; 147: 726-735, 2017 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-27902936

RESUMO

Resting-state fMRI studies have become very important in cognitive neuroscience because they are able to identify BOLD fluctuations in brain circuits involved in motor, cognitive, or perceptual processes without the use of an explicit task. Such approaches have been fruitful when applied to various disordered populations, or to children or the elderly. However, insufficient attention has been paid to the consequences of the loud acoustic scanner noise associated with conventional fMRI acquisition, which could be an important confounding factor affecting auditory and/or cognitive networks in resting-state fMRI. Several approaches have been developed to mitigate the effects of acoustic noise on fMRI signals, including sparse sampling protocols and interleaved silent steady state (ISSS) acquisition methods, the latter being used only for task-based fMRI. Here, we developed an ISSS protocol for resting-state fMRI (rs-ISSS) consisting of rapid acquisition of a set of echo planar imaging volumes following each silent period, during which the steady state longitudinal magnetization was maintained with a train of relatively silent slice-selective excitation pulses. We evaluated the test-retest reliability of intensity and spatial extent of connectivity networks of fMRI BOLD signal across three different days for rs-ISSS and compared it with a standard resting-state fMRI (rs-STD). We also compared the strength and distribution of connectivity networks between rs-ISSS and rs-STD. We found that both rs-ISSS and rs-STD showed high reproducibility of fMRI signal across days. In addition, rs-ISSS showed a more robust pattern of functional connectivity within the somatosensory and motor networks, as well as an auditory network compared with rs-STD. An increased connectivity between the default mode network and the language network and with the anterior cingulate cortex (ACC) network was also found for rs-ISSS compared with rs-STD. Finally, region of interest analysis showed higher interhemispheric connectivity in Heschl's gyri in rs-ISSS compared with rs-STD, with lower variability across days. The present findings suggest that rs-ISSS may be advantageous for detecting network connectivity in a less noisy environment, and that resting-state studies carried out with standard scanning protocols should consider the potential effects of loud noise on the measured networks.


Assuntos
Percepção Auditiva/fisiologia , Mapeamento Encefálico/métodos , Córtex Cerebral/fisiologia , Imageamento por Ressonância Magnética/métodos , Rede Nervosa/fisiologia , Adolescente , Adulto , Mapeamento Encefálico/normas , Córtex Cerebral/diagnóstico por imagem , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Feminino , Humanos , Imageamento por Ressonância Magnética/normas , Masculino , Rede Nervosa/diagnóstico por imagem , Ruído , Reprodutibilidade dos Testes , Descanso , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA