Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 600(7888): 279-284, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34837071

RESUMO

Confocal microscopy1 remains a major workhorse in biomedical optical microscopy owing to its reliability and flexibility in imaging various samples, but suffers from substantial point spread function anisotropy, diffraction-limited resolution, depth-dependent degradation in scattering samples and volumetric bleaching2. Here we address these problems, enhancing confocal microscopy performance from the sub-micrometre to millimetre spatial scale and the millisecond to hour temporal scale, improving both lateral and axial resolution more than twofold while simultaneously reducing phototoxicity. We achieve these gains using an integrated, four-pronged approach: (1) developing compact line scanners that enable sensitive, rapid, diffraction-limited imaging over large areas; (2) combining line-scanning with multiview imaging, developing reconstruction algorithms that improve resolution isotropy and recover signal otherwise lost to scattering; (3) adapting techniques from structured illumination microscopy, achieving super-resolution imaging in densely labelled, thick samples; (4) synergizing deep learning with these advances, further improving imaging speed, resolution and duration. We demonstrate these capabilities on more than 20 distinct fixed and live samples, including protein distributions in single cells; nuclei and developing neurons in Caenorhabditis elegans embryos, larvae and adults; myoblasts in imaginal disks of Drosophila wings; and mouse renal, oesophageal, cardiac and brain tissues.


Assuntos
Aprendizado Profundo , Microscopia Confocal/métodos , Microscopia Confocal/normas , Animais , Caenorhabditis elegans/citologia , Caenorhabditis elegans/embriologia , Caenorhabditis elegans/crescimento & desenvolvimento , Linhagem Celular Tumoral , Drosophila melanogaster/citologia , Drosophila melanogaster/crescimento & desenvolvimento , Humanos , Discos Imaginais/citologia , Camundongos , Mioblastos/citologia , Especificidade de Órgãos , Análise de Célula Única , Fixação de Tecidos
2.
J Neuroinflammation ; 18(1): 89, 2021 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-33832507

RESUMO

BACKGROUND: Immune-mediated neuropathies, such as chronic inflammatory demyelinating polyneuropathy (CIDP) are treatable neuropathies. Among individuals with diabetic neuropathy, it remains a challenge to identify those individuals who develop CIDP. Corneal confocal microscopy (CCM) has been shown to detect corneal nerve fiber loss and cellular infiltrates in the sub-basal layer of the cornea. The objective of the study was to determine whether CCM can distinguish diabetic neuropathy from CIDP and whether CCM can detect CIDP in persons with coexisting diabetes. METHODS: In this multicenter, case-control study, participants with CIDP (n = 55) with (n = 10) and without (n = 45) diabetes; participants with diabetes (n = 58) with (n = 28) and without (n = 30) diabetic neuropathy, and healthy controls (n = 58) underwent CCM. Corneal nerve fiber density (CNFD), corneal nerve fiber length (CNFL), corneal nerve branch density (CNBD), and dendritic and non-dendritic cell density, with or without nerve fiber contact were quantified. RESULTS: Dendritic cell density in proximity to corneal nerve fibers was significantly higher in participants with CIDP with and without diabetes compared to participants with diabetic neuropathy and controls. CNFD, CNFL, and CNBD were equally reduced in participants with CIDP, diabetic neuropathy, and CIDP with diabetes. CONCLUSIONS: An increase in dendritic cell density identifies persons with CIDP. CCM may, therefore, be useful to differentiate inflammatory from non-inflammatory diabetic neuropathy.


Assuntos
Córnea/patologia , Dendritos/patologia , Diabetes Mellitus Tipo 2/diagnóstico , Neuropatias Diabéticas/diagnóstico , Polirradiculoneuropatia Desmielinizante Inflamatória Crônica/diagnóstico , Adulto , Idoso , Estudos de Casos e Controles , Diabetes Mellitus Tipo 2/epidemiologia , Neuropatias Diabéticas/epidemiologia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Microscopia Confocal/métodos , Microscopia Confocal/normas , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Polirradiculoneuropatia Desmielinizante Inflamatória Crônica/epidemiologia
3.
Exp Dermatol ; 30(7): 911-922, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33884663

RESUMO

Non-invasive reflectance confocal microscopy (RCM) and optical coherence tomography (OCT) have been extended to the dermo-cosmetic field, for skin pathophysiology understanding and therapeutics monitoring. However, standardized methodology and parameters to interpret structures and changes in these settings are still lacking. Present study aimed to propose a validated standard methodology and a list of defined parameters for objective non-pathological skin assessments in the cosmetically sensitive cheekbone area of the face. OCT and RCM quantitative, semi-quantitative and qualitative features were considered for assessments. Validation process included 50 sets of images divided into two age groups. Inter-rater reliability was explored to assess the influence of the proposed methodology. Quantitative OCT parameters of "epidermal thickness," "density and attenuation coefficients" and "vascular density" were considered and calculated. Severity scales were developed for semi-quantitative OCT features of "disruption of collagen" and "vascular asset," while extent scales were produced for semi-quantitative RCM "irregular honeycomb," "mottled pigmentation" and "polycyclic papillary contours." Qualitative assessment was obtained for RCM type of collagen, and comparison between age groups was performed for all features considered. Severity visual scales assistance proved excellent inter-rater agreement across all semi-quantitative and qualitative domains. The assistance of shareable software systems allows for objective OCT quantitative parameters measurement. The use of standard reference scales, within a defined assessment methodology, offers high inter-rater reliability and thus reproducibility for semi-quantitative and qualitative OCT and RCM parameters. Taken together, our results may represent a starting point for a standardized application of RCM and OCT in dermo-cosmetic research and practice.


Assuntos
Cosméticos , Microscopia Confocal/normas , Dermatopatias/diagnóstico por imagem , Tomografia de Coerência Óptica/normas , Humanos
4.
Skin Res Technol ; 25(2): 229-233, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30367506

RESUMO

BACKGROUND: In the clinical practice, transparent films are used as sterile interfaces in in vivo dermatologic imaging in order to prevent the transmissions of infections. However, in our experience, the use of a transparent film can alter skin images. Our study aimed to compare the optical quality of a series of different plastic films used as interfaces in order to understand if some might be more suitable for imaging. MATERIALS AND METHODS: We tested the optical properties of 11 different protective transparent films that are marketed in France with a transparency meter and a spectrophotometer. RESULTS: Transmission, minimal diffusion, amount of gray, and contrast were obtained for each transparent film. Transmission ranged from 93.24% to 96.88% (mean 95.36; standard deviation SD 1.02), minimal diffusion from 88.28% to 123.87% (mean 101.04; standard deviation SD 10.02) and contrast from 11.01 to 15.88 (mean 13.93 and SD 1.3). For some films, the transmission was lower at lower wavelengths. CONCLUSION: All tested films had excellent optical properties. However, some of them had better optical qualities and seemed more suitable for their use in dermatologic imaging.


Assuntos
Dermatologia/instrumentação , Dermoscopia/instrumentação , Transmissão de Doença Infecciosa/prevenção & controle , Dermatologia/normas , Dermoscopia/normas , Desenho de Equipamento/instrumentação , Desenho de Equipamento/normas , Humanos , Aumento da Imagem/instrumentação , Aumento da Imagem/normas , Microscopia Confocal/instrumentação , Microscopia Confocal/normas , Microscopia de Interferência/instrumentação , Microscopia de Interferência/normas , Plásticos , Guias de Prática Clínica como Assunto
5.
Pharm Res ; 35(7): 146, 2018 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-29796727

RESUMO

PURPOSE: The proper understanding of glass delamination is important to glass manufacturers, pharmaceutical companies, and health authorities to mitigate the occurrence of glass flakes from the vial when in contact with specific drug product solutions. The surface of glass vials is altered during glass cane- and vial forming processes and is exposed to different stress conditions during drug product processing before coming in contact with the drug product solution. In this study, the impact of vial washing and depyrogenation including an evaluation of various residual water volumes on surface properties of glass vials was investigated for a defined set of vials. METHODS: 3D laser scanning microscopy was established as a new method for topographic analysis of curved surfaces of glass vials operating in high-throughput mode. A subset of vials was subsequently exposed to delamination stress testing and both the stressed solution and inner vial surface were analyzed by a panel of conventional and advanced analytical techniques including 3D laser scanning microscopy. RESULTS: The data showed that vial washing and depyrogenation strongly influenced surface properties, in particular those of uncoated vials. Surface characteristics such as pits increased depending on the process conditions, which especially applies to Expansion 33 vials. Even low residual water volumes of 50 µL after vial washing were sufficient to change the surface properties of the glass and weaken the surface in those positions prone to glass delamination. An increase in pits was related to a greater risk for glass delamination. CONCLUSIONS: Vial processing conditions need to be assessed when aiming at minimizing the glass delamination risk during parenteral product storage.


Assuntos
Descontaminação/métodos , Embalagem de Medicamentos , Vidro/química , Descontaminação/normas , Embalagem de Medicamentos/normas , Vidro/análise , Imageamento Tridimensional/métodos , Imageamento Tridimensional/normas , Microscopia Confocal/métodos , Microscopia Confocal/normas , Propriedades de Superfície
6.
Scand J Gastroenterol ; 53(10-11): 1358-1363, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30394137

RESUMO

OBJECTIVES: Evaluation of indeterminate biliary strictures remains challenging due to limited sensitivity of endoscopic tissue sampling. Biliary probe-based confocal laser endomicroscopy (pCLE) has shown promise to detect and exclude neoplasia. However, knowledge of whether individual inflammatory criteria are more prevalent in neoplasia compared to benign strictures is limited. The objective of this work is to improve diagnosis of neoplastic and inflammatory conditions using pCLE. MATERIALS AND METHODS: The charts of all patients who underwent pCLE at a single referral center between 2009 and 2015 were reviewed. ERCP reports were reviewed for eleven Miami and Paris criteria. Primary outcome was the identification of neoplasia by histopathology (defined as high-grade dysplasia and/or adenocarcinoma). To model predictors of neoplasia, we fit a binary regression model incorporating data from pCLE operating criteria, pCLE impression, and PSC status. RESULTS: 97 patients were identified. In the 27 patients with neoplasia, there was increasing number of Miami malignant criteria (Pearson r = 0.512, p < .001) while inflammatory criteria were less prevalent. 10% (5/51, p < .001) of patients with benign pCLE impression developed neoplasia, while 48% (22/46, p < .001) with suspicious pCLE impressions developed neoplasia. The binary regression model to predict neoplasia had a sensitivity of 83.3%, specificity of 92.5%, and overall accuracy 89.7%. CONCLUSIONS: Presence of malignant criteria and absence of certain inflammatory criteria are more prevalent in patients with neoplasia. Our model, which weights individual imaging components, shows impressive sensitivity and specificity over prior prognostic efforts. Prospective studies will be required to evaluate this model.


Assuntos
Neoplasias dos Ductos Biliares/diagnóstico , Ductos Biliares Intra-Hepáticos , Colangiocarcinoma/diagnóstico , Colangiopancreatografia Retrógrada Endoscópica/normas , Microscopia Confocal/normas , Adulto , Idoso , Neoplasias dos Ductos Biliares/complicações , Colangiocarcinoma/complicações , Constrição Patológica/diagnóstico , Constrição Patológica/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Curva ROC , Análise de Regressão , Sensibilidade e Especificidade
7.
Skin Res Technol ; 24(2): 223-228, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29178413

RESUMO

BACKGROUND: In vivo reflectance confocal microscopy (RCM) represents a promising technique for noninvasive visualization of skin lesions. In the clinical daily practice, doctors want to know the relationship between the RCM images and the skin pathological changes. OBJECTIVE: The aim of this study was to identify the basic skin pathological changes under RCM, and use RCM terminology to describe these pathological changes. METHODS: A total of 100 patients were recruited and were evaluated both by RCM and histopathologic examination. Ten healthy volunteers were also recruited as control. RCM examinations were done and biopsies of the lesions at the same site of RCM examination were performed for histopathology analysis. RESULTS: The pathological changes including hyperkeratosis, parakeratosis, acanthosis, papilloma, spongiosis, pustule, vacuolar degeneration, hyperpigmentation, changes of collagen fibers, and vascular changes can be imaged by RCM and corresponded well to their histopathology. RCM failed to find the atypical keratinocytes in two squamous cell carcinoma cases because of the hyperkeratosis and failed to find the vascular changes in one port wine stain cases because of the limitation of detecting depth. CONCLUSION: Features correlating well to histopathology are observed on RCM. RCM can be used as an auxiliary diagnosis tool for the clinical diagnosis.


Assuntos
Dermatopatias/patologia , Vasos Sanguíneos/diagnóstico por imagem , Colágeno/análise , Feminino , Voluntários Saudáveis , Humanos , Masculino , Microscopia Confocal/normas , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Pele/irrigação sanguínea , Dermatopatias/diagnóstico por imagem
8.
J Proteome Res ; 16(1): 147-155, 2017 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-27723985

RESUMO

Antibodies are indispensible research tools, yet the scientific community has not adopted standardized procedures to validate their specificity. Here we present a strategy to systematically validate antibodies for immunofluorescence (IF) applications using gene tagging. We have assessed the on- and off-target binding capabilities of 197 antibodies using 108 cell lines expressing EGFP-tagged target proteins at endogenous levels. Furthermore, we assessed batch-to-batch effects for 35 target proteins, showing that both the on- and off-target binding patterns vary significantly between antibody batches and that the proposed strategy serves as a reliable procedure for ensuring reproducibility upon production of new antibody batches. In summary, we present a systematic scheme for antibody validation in IF applications using endogenous expression of tagged proteins. This is an important step toward a reproducible approach for context- and application-specific antibody validation and improved reliability of antibody-based experiments and research data.


Assuntos
Anticorpos/análise , Imunofluorescência/normas , Microscopia Confocal/normas , Coloração e Rotulagem/métodos , Análise de Variância , Anticorpos/química , Atlas como Assunto , Linhagem Celular , Expressão Gênica , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Humanos , Padrões de Referência , Reprodutibilidade dos Testes
9.
J Microsc ; 267(3): 356-370, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28474765

RESUMO

In the last few years, the study of cut marks on bone surfaces has become fundamental for the interpretation of prehistoric butchery practices. Due to the difficulties in the correct identification of cut marks, many criteria for their description and classification have been suggested. Different techniques, such as three-dimensional digital microscope (3D DM), laser scanning confocal microscopy (LSCM) and micro-photogrammetry (M-PG) have been recently applied to the study of cut marks. Although the 3D DM and LSCM microscopic techniques are the most commonly used for the 3D identification of cut marks, M-PG has also proved to be very efficient and a low-cost method. M-PG is a noninvasive technique that allows the study of the cortical surface without any previous preparation of the samples, and that generates high-resolution models. Despite the current application of microscopic and micro-photogrammetric techniques to taphonomy, their reliability has never been tested. In this paper, we compare 3D DM, LSCM and M-PG in order to assess their resolution and results. In this study, we analyse 26 experimental cut marks generated with a metal knife. The quantitative and qualitative information registered is analysed by means of standard multivariate statistics and geometric morphometrics to assess the similarities and differences obtained with the different methodologies.


Assuntos
Imageamento Tridimensional , Microscopia Confocal , Modelos Estatísticos , Fotogrametria , Análise de Variância , Processamento de Imagem Assistida por Computador , Microscopia Confocal/instrumentação , Microscopia Confocal/métodos , Microscopia Confocal/normas , Fotogrametria/instrumentação , Fotogrametria/métodos , Fotogrametria/normas , Reprodutibilidade dos Testes
10.
Adv Exp Med Biol ; 977: 183-190, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28685444

RESUMO

When high-magnification images are taken with a quasi-confocal line scanning ophthalmoscope (LSO), the quality of images always suffers from Gaussian noise, and the signal to noise ratio (SNR) is very low for a safer laser illumination. In addition, motions of the retina severely affect the stabilization of the real-time video resulting in significant distortions or warped images. We describe a scale-invariant feature transform (SIFT) algorithm to automatically abstract corner points with subpixel resolution and match these points in sequential images using an affine transformation. Once n images are aligned and averaged, the noise level drops by a factor of [Formula: see text] and the image quality is improved. The improvement of image quality is independent of the acquisition method as long as the image is not warped, particularly severely during confocal scanning. Consequently, even better results can be expected by implementing this image processing technique on higher resolution images.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Microscopia Confocal , Oftalmoscópios , Oftalmoscopia/métodos , Retina/diagnóstico por imagem , Humanos , Aumento da Imagem/instrumentação , Microscopia Confocal/instrumentação , Microscopia Confocal/métodos , Microscopia Confocal/normas , Oftalmoscópios/normas , Razão Sinal-Ruído
11.
Ophthalmology ; 123(6): 1181-9, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26992843

RESUMO

PURPOSE: Ruling out glaucoma in myopic eyes often poses a diagnostic challenge because of atypical optic disc morphology and visual field defects that can mimic glaucoma. We determined whether neuroretinal rim assessment based on Bruch's membrane opening (BMO), rather than conventional optic disc margin (DM)-based assessment or retinal nerve fiber layer (RNFL) thickness, yielded higher diagnostic accuracy in myopic patients with glaucoma. DESIGN: Case-control, cross-sectional study. PARTICIPANTS: Myopic patients with glaucoma (n = 56) and myopic normal controls (n = 74). METHODS: Myopic subjects with refraction error greater than -2 diopters (D) (spherical equivalent) and typical myopic optic disc morphology, with and without glaucoma, were recruited from a glaucoma clinic and a local optometry practice. The final classification of myopic glaucoma or myopic control was based on consensus assessment by 3 clinicians of visual fields and optic disc photographs. Participants underwent imaging with confocal scanning laser tomography for measurement of DM rim area (DM-RA) and with spectral domain optical coherence tomography (SD OCT) for quantification of a BMO-based neuroretinal rim parameter, minimum rim width (BMO-MRW), and RNFL thickness. MAIN OUTCOME MEASURES: Sensitivity of DM-RA, BMO-MRW, and RNFL thickness at a fixed specificity of 90% and partial area under the curves (pAUCs) for global and sectoral parameters for specificities ≥90%. RESULTS: Sensitivities at 90% specificity were 30% for DM-RA and 71% for both BMO-MRW and RNFL thickness. The pAUC was higher for the BMO-MRW compared with DM-RA (P < 0.001), but similar to RNFL thickness (P > 0.5). Sectoral values of BMO-MRW tended to have a higher, but nonsignificant, pAUC across all sectors compared with RNFL thickness. CONCLUSIONS: Bruch's membrane opening MRW is more sensitive than DM-RA and similar to RNFL thickness for the identification of glaucoma in myopic eyes and offers a valuable diagnostic tool for patients with glaucoma with myopic optic discs.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Glaucoma de Ângulo Aberto/diagnóstico , Miopia/diagnóstico , Fibras Nervosas/patologia , Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Células Ganglionares da Retina/patologia , Área Sob a Curva , Lâmina Basilar da Corioide/patologia , Estudos de Casos e Controles , Estudos Transversais , Técnicas de Diagnóstico Oftalmológico/normas , Reações Falso-Negativas , Feminino , Humanos , Pressão Intraocular , Masculino , Microscopia Confocal/normas , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia de Coerência Óptica/normas , Transtornos da Visão/diagnóstico , Campos Visuais
12.
Br J Dermatol ; 175(2): 364-74, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26948927

RESUMO

BACKGROUND: The real value of reflectance confocal microscopy (RCM) for the evaluation of inflammatory skin conditions remains unclear. A project on RCM for inflammatory skin diseases involving international centres was designed by a coordinating centre and executed under the supervision of the International Confocal Working Group. OBJECTIVES: To identify specific confocal features useful for distinction between the three main groups of superficial inflammatory skin diseases. METHODS: Nineteen different RCM features were evaluated in a total of 155 lesions, diagnosed as spongiotic (45), interface (52) or psoriasiform (58) dermatitis, collected by a consortium of 19 different centres. RESULTS: Univariate and multivariate analysis identified RCM descriptors for the three main superficial inflammatory disease groups. Later, a multivariate method was employed to define a scoring system to be applied on an algorithmic method of analysis for fast clinical application. CONCLUSIONS: Our preliminary evaluation supports the use of RCM for the identification of confocal patterns consistent with the major features of the diagnostic groups of inflammatory skin diseases. Moreover, an efficient multivariate method for clinical in vivo RCM diagnosis using a tree decision diagram has been established.


Assuntos
Dermatite/patologia , Algoritmos , Análise de Variância , Tomada de Decisão Clínica , Árvores de Decisões , Dermatite/diagnóstico por imagem , Humanos , Microscopia Confocal/normas , Curva ROC
13.
Gastrointest Endosc ; 83(4): 785-91.e1, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26344879

RESUMO

BACKGROUND AND AIMS: Confocal laser endomicroscopy can dynamically assess intestinal mucosal barrier defects and increased intestinal permeability (IP). These are functional features that do not have corresponding appearance on histopathology. As such, previous pathology training may not be beneficial in learning these dynamic features. This study aims to evaluate the diagnostic accuracy, learning curve, inter- and intraobserver agreement for identifying features of increased IP in experienced and inexperienced analysts and pathologists. METHODS: A total of 180 endoscopic confocal laser endomicroscopy (Pentax EC-3870FK; Pentax, Tokyo, Japan) images of the terminal ileum, subdivided into 6 sets of 30 were evaluated by 6 experienced analysts, 13 inexperienced analysts, and 2 pathologists, after a 30-minute teaching session. Cell-junction enhancement, fluorescein leak, and cell dropout were used to represent increased IP and were either present or absent in each image. For each image, the diagnostic accuracy, confidence, and quality were assessed. RESULTS: Diagnostic accuracy was significantly higher for experienced analysts compared with inexperienced analysts from the first set (96.7% vs 83.1%, P < .001) to the third set (95% vs 89.7, P = .127). No differences in accuracy were noted between inexperienced analysts and pathologists. Confidence (odds ratio, 8.71; 95% confidence interval, 5.58-13.57) and good image quality (odds ratio, 1.58; 95% confidence interval, 1.22-2.03) were associated with improved interpretation. Interobserver agreement κ values were high and improved with experience (experienced analysts, 0.83; inexperienced analysts, 0.73; and pathologists, 0.62). Intraobserver agreement was >0.86 for experienced observers. CONCLUSION: Features representative of increased IP can be rapidly learned with high inter- and intraobserver agreement. Confidence and image quality were significant predictors of accurate interpretation. Previous pathology training did not have an effect on learning.


Assuntos
Endoscopia Gastrointestinal , Doenças Inflamatórias Intestinais/diagnóstico por imagem , Mucosa Intestinal/diagnóstico por imagem , Mucosa Intestinal/metabolismo , Curva de Aprendizado , Variações Dependentes do Observador , Competência Clínica , Humanos , Doenças Inflamatórias Intestinais/patologia , Doenças Inflamatórias Intestinais/fisiopatologia , Mucosa Intestinal/patologia , Microscopia Confocal/normas , Permeabilidade
14.
Gastrointest Endosc ; 83(4): 684-98.e7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26874597

RESUMO

BACKGROUND AND AIMS: Endoscopic real-time imaging of Barrett's esophagus (BE) with advanced imaging technologies enables targeted biopsies and may eliminate the need for random biopsies to detect dysplasia during endoscopic surveillance of BE. This systematic review and meta-analysis was performed by the American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee to specifically assess whether acceptable performance thresholds outlined by the ASGE Preservation and Incorporation of Valuable Endoscopic Innovations (PIVI) document for clinical adoption of these technologies have been met. METHODS: We conducted meta-analyses calculating the pooled sensitivity, negative predictive value (NPV), and specificity for chromoendoscopy by using acetic acid and methylene blue, electronic chromoendoscopy by using narrow-band imaging, and confocal laser endomicroscopy (CLE) for the detection of dysplasia. Random effects meta-analysis models were used. Statistical heterogeneity was evaluated by means of I(2) statistics. RESULTS: The pooled sensitivity, NPV, and specificity for acetic acid chromoendoscopy were 96.6% (95% confidence interval [CI], 95-98), 98.3% (95% CI, 94.8-99.4), and 84.6% (95% CI, 68.5-93.2), respectively. The pooled sensitivity, NPV, and specificity for electronic chromoendoscopy by using narrow-band imaging were 94.2% (95% CI, 82.6-98.2), 97.5% (95% CI, 95.1-98.7), and 94.4% (95% CI, 80.5-98.6), respectively. The pooled sensitivity, NPV, and specificity for endoscope-based CLE were 90.4% (95% CI, 71.9-97.2), 98.3% (95% CI, 94.2-99.5), and 92.7% (95% CI, 87-96), respectively. CONCLUSIONS: Our meta-analysis indicates that targeted biopsies with acetic acid chromoendoscopy, electronic chromoendoscopy by using narrow-band imaging, and endoscope-based CLE meet the thresholds set by the ASGE PIVI, at least when performed by endoscopists with expertise in advanced imaging techniques. The ASGE Technology Committee therefore endorses using these advanced imaging modalities to guide targeted biopsies for the detection of dysplasia during surveillance of patients with previously nondysplastic BE, thereby replacing the currently used random biopsy protocols.


Assuntos
Esôfago de Barrett/diagnóstico por imagem , Esôfago de Barrett/patologia , Esofagoscopia/métodos , Esôfago/patologia , Ácido Acético , Biópsia/métodos , Corantes , Esofagoscopia/normas , Humanos , Microscopia Intravital/normas , Azul de Metileno , Microscopia Confocal/normas , Imagem de Banda Estreita/normas , Valor Preditivo dos Testes , Conduta Expectante
15.
Gastrointest Endosc ; 84(6): 917-923.e5, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27189657

RESUMO

BACKGROUND AND AIMS: Image quality can be guaranteed with the conventional dosage of fluorescein sodium in probe-based confocal laser endomicroscopy (pCLE). However, yellow discoloration of the skin seriously affects daily life and simultaneously increases the risk of adverse events such as allergic reactions. The aim of this study was to test whether a lower dosage of fluorescein sodium can provide satisfactory image quality and to compare the diagnostic accuracy of gastric intestinal metaplasia (GIM) through a randomized blind controlled trial. METHODS: Consecutive patients were randomly assigned to different doses of fluorescein sodium. Image quality was determined by the endoscopists' subjective assessments and signal-to-noise ratio (SNR) assessment systems. Skin discoloration was tested using a neonatal transcutaneous jaundice detector. In addition, consecutive patients with a known or suspected diagnosis of GIM were examined by pCLE with the lower dose and the traditional dose. RESULTS: Only 0.01 mL/kg dose of 10% fluorescein sodium led to a significant decrease in image quality (P < .05), and a dose of 0.02 mL/kg had the highest SNR value (P < .05). There were no significant differences in skin discoloration between the 0.01 mL/kg and 0.02 mL/kg doses (P = .148) and no statistical difference in the diagnostic accuracy of pCLE for GIM between the 0.02 mL/kg and 0.10 mL/kg doses (P > .05). The kappa values for the correlation between pCLE and histopathology were 0.867 (95% confidence interval, 0.782-0.952) and 0.891 (95% confidence interval, 0.811-0.971). CONCLUSIONS: The 0.02 mL/kg dose of 10% fluorescein sodium seems to be the best dose for pCLE in the upper GI tract, with comparable image quality with the conventional dose and insignificant skin discoloration. This dose is also very efficient for the diagnosis of GIM.


Assuntos
Meios de Contraste/administração & dosagem , Fluoresceína/administração & dosagem , Trato Gastrointestinal/patologia , Microscopia Intravital/métodos , Adulto , Idoso , Meios de Contraste/efeitos adversos , Endoscopia Gastrointestinal , Estudos de Viabilidade , Feminino , Fluoresceína/efeitos adversos , Humanos , Microscopia Intravital/normas , Masculino , Metaplasia/diagnóstico por imagem , Microscopia Confocal/métodos , Microscopia Confocal/normas , Pessoa de Meia-Idade , Transtornos da Pigmentação/induzido quimicamente , Razão Sinal-Ruído , Método Simples-Cego , Pigmentação da Pele/efeitos dos fármacos , Adulto Jovem
16.
BMC Ophthalmol ; 16(1): 163, 2016 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-27645227

RESUMO

BACKGROUND: To compare corneal epithelial thickness (CET) and limbal epithelial thickness (LET) measured by anterior segment optical coherence tomography (AS-OCT) and in vivo confocal microscope (IVCM) in normal subjects, and evaluate the consistency between them. METHODS: Thirty-eight normal subjects (17 men and 21 women) were enrolled in this study. AS-OCT was performed at central cornea and the superior, inferior, nasal and temporal limbus. Then followed by IVCM examination performed at the same location. Agreement was analyzed by mean difference (AS-OCT minus IVCM), 95 % limits of agreement (LoA) (1.96 standard deviation of the difference), and Bland-Altman analysis. RESULTS: The average CET measured by AS-OCT and IVCM was 55.6 ± 4.0 µm and 51.9 ± 4.9 µm respectively. The value measured by IVCM was significantly lower than that measured by AS-OCT (P = 0.015). The average LET values tested by AS-OCT were 10.3 and 10.9 % less at nasal and temporal quadrant (nasal: P = 0.019, temporal: P = 0.003), and were similar as those measured by IVCM at superior and inferior quadrant. In subjects older than 40 years, CET and LET values measured by AS-OCT were significantly higher than those by IVCM. Such differences were not found in subjects ≤ 40 years old. CONCLUSIONS: CET values measured by IVCM are lower than those by AS-OCT, while LET values measured by two devices have good agreement. These two techniques have their own advantages in measuring epithelial thickness and are mutually complementary.


Assuntos
Segmento Anterior do Olho/diagnóstico por imagem , Córnea/diagnóstico por imagem , Microscopia Confocal/métodos , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Segmento Anterior do Olho/anatomia & histologia , Córnea/anatomia & histologia , Doenças da Córnea/diagnóstico por imagem , Doenças da Córnea/patologia , Feminino , Humanos , Limbo da Córnea/anatomia & histologia , Limbo da Córnea/diagnóstico por imagem , Masculino , Microscopia Confocal/normas , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/normas , Adulto Jovem
17.
Circ Res ; 112(3): 424-31, 2013 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-23243207

RESUMO

RATIONALE: Mitochondrial [Ca(2+)] ([Ca(2+)](mito)) regulates mitochondrial energy production, provides transient Ca(2+) buffering under stress, and can be involved in cell death. Mitochondria are near the sarcoplasmic reticulum (SR) in cardiac myocytes, and evidence for crosstalk exists. However, quantitative measurements of [Ca(2+)](mito) are limited, and spatial [Ca(2+)](mito) gradients have not been directly measured. OBJECTIVE: To directly measure local [Ca(2+)](mito) during normal SR Ca release in intact myocytes, and evaluate potential subsarcomeric spatial [Ca(2+)](mito) gradients. METHODS AND RESULTS: Using the mitochondrially targeted inverse pericam indicator Mitycam, calibrated in situ, we directly measured [Ca(2+)](mito) during SR Ca(2+) release in intact rabbit ventricular myocytes by confocal microscopy. During steady state pacing, Δ[Ca(2+)](mito) amplitude was 29±3 nmol/L, rising rapidly (similar to cytosolic free [Ca(2+)]) but declining much more slowly. Taking advantage of the structural periodicity of cardiac sarcomeres, we found that [Ca(2+)](mito) near SR Ca(2+) release sites (Z-line) versus mid-sarcomere (M-line) reached a high peak amplitude (37±4 versus 26±4 nmol/L, respectively P<0.05) which occurred earlier in time. This difference was attributed to ends of mitochondria being physically closer to SR Ca(2+) release sites, because the mitochondrial Ca(2+) uniporter was homogeneously distributed, and elevated [Ca(2+)] applied laterally did not produce longitudinal [Ca(2+)](mito) gradients. CONCLUSIONS: We developed methods to measure spatiotemporal [Ca(2+)](mito) gradients quantitatively during excitation-contraction coupling. The amplitude and kinetics of [Ca(2+)](mito) transients differ significantly from those in the cytosol and are respectively higher and faster near the Z-line versus M-line. This approach will help clarify SR-mitochondrial Ca(2+) signaling.


Assuntos
Sinalização do Cálcio , Cálcio/metabolismo , Mitocôndrias Cardíacas/metabolismo , Miócitos Cardíacos/metabolismo , Retículo Sarcoplasmático/metabolismo , Animais , Técnicas Biossensoriais/normas , Calibragem , Estimulação Cardíaca Artificial , Células Cultivadas , Citosol/metabolismo , Acoplamento Excitação-Contração , Corantes Fluorescentes/metabolismo , Cinética , Microscopia Confocal/normas , Microscopia de Fluorescência/normas , Contração Miocárdica , Coelhos , Transfecção
18.
J Microsc ; 257(1): 31-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25227160

RESUMO

To take full advantage of fast resonant scanning in super-resolution stimulated emission depletion (STED) microscopy, we have developed an ultrafast photon counting system based on a multigiga sample per second analogue-to-digital conversion chip that delivers an unprecedented 450 MHz pixel clock (2.2 ns pixel dwell time in each scan). The system achieves a large field of view (∼50 × 50 µm) with fast scanning that reduces photobleaching, and advances the time-gated continuous wave STED technology to the usage of resonant scanning with hardware-based time-gating. The assembled system provides superb signal-to-noise ratio and highly linear quantification of light that result in superior image quality. Also, the system design allows great flexibility in processing photon signals to further improve the dynamic range. In conclusion, we have constructed a frontier photon counting image acquisition system with ultrafast readout rate, excellent counting linearity, and with the capacity of realizing resonant-scanning continuous wave STED microscopy with online time-gated detection.


Assuntos
Microscopia Confocal/métodos , Microscopia Confocal/normas , Microscopia de Fluorescência/métodos , Microscopia de Fluorescência/normas , Fótons , Desenho de Equipamento , Aumento da Imagem , Miócitos Cardíacos
19.
J Gastroenterol Hepatol ; 30 Suppl 1: 85-92, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25827810

RESUMO

BACKGROUND AND AIM: Endoscopic assessment of mucosal healing in ulcerative colitis (UC) is increasingly accepted as a measure of disease activity, therapeutic goal, and the key prognostic indicator. While regular endoscopy evaluates appearance of the mucosal surface, confocal laser endomicroscopy (CLE) enables in vivo visualization of subepithelial mucosa at 1000× magnification during ongoing endoscopy. Our aims were to determine using CLE whether endoscopically normal appearing colonic mucosa in patients with UC in remission (UC-IR) has fully regenerated mucosal structures, resolved inflammation, and to identify the mechanisms. METHODS: Twelve patients (six controls and six with UC-IR) underwent colonoscopy using CLE and intravenous fluorescein infusion. During colonoscopy, CLE images of colonic mucosa and conventional mucosal biopsies were obtained and evaluated using image-analysis systems. We quantified; (i) regeneration of colonic crypts and blood microvessels; (ii) cyclooxygenase 2 (COX2) expression; (iii) mitochondrial DNA (mtDNA) mutations; (iv) inflammatory infiltration; and (v) vascular permeability (VP). RESULTS: In control subjects, CLE demonstrated normal colonic crypts and microvasculature. COX2 expression was minimal, and < 7% crypts showed mtDNA mutations. Colonic mucosa of UC-IR patients had impaired and distorted crypt regeneration, increased COX2, 69% crypts with mtDNA mutations, persistent inflammation, and abnormal vascular architecture with increased VP (all P < 0.001 vs normal mucosa). CONCLUSIONS: (i) Endoscopically normal appearing colonic mucosa of patients with UC-IR remains abnormal: CLE demonstrates impaired crypt regeneration, persistent inflammation, distinct abnormalities in angioarchitecture and increased vascular permeability; molecular imaging showed increased COX2 and mtDNA mutations; (ii) CLE may serve as a new gold standard for the assessment of mucosal healing in UC.


Assuntos
Colite Ulcerativa/patologia , Endoscopia Gastrointestinal/métodos , Mucosa Intestinal/patologia , Microscopia Confocal/métodos , Imagem Molecular/métodos , Imagem Molecular/normas , Cicatrização , Adulto , Idoso , Colite Ulcerativa/genética , Colite Ulcerativa/metabolismo , Colite Ulcerativa/fisiopatologia , Ciclo-Oxigenase 2/metabolismo , DNA Mitocondrial/genética , Endoscopia Gastrointestinal/normas , Feminino , Humanos , Mucosa Intestinal/fisiologia , Masculino , Microscopia Confocal/normas , Pessoa de Meia-Idade , Mutação
20.
J Am Acad Dermatol ; 71(4): 611.e1-611.e10; quiz 621-2, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25219717

RESUMO

New evidence has accumulated over the past several years that supports improved melanoma outcomes associated with both clinician and patient screening. Population-based and workplace studies conducted in Australia and the Unites States, respectively, have shown decreases in the incidence of thick melanoma and overall melanoma mortality, and a year-long statewide screening program in Germany has shown a nearly 50% reduction in mortality 5 years after the screening ended. Current melanoma screening guidelines in the United States are inconsistent among various organizations, and therefore rates of both physician and patient skin examinations are low. As policymaking organizations update national screening recommendations in the United States, the latest research reviewed in part II of this continuing medical education article should be considered to establish the most effective recommendations. Patient and provider education will be necessary to ensure that appropriate patients receive recommended screening.


Assuntos
Detecção Precoce de Câncer/normas , Melanoma/diagnóstico , Melanoma/epidemiologia , Neoplasias Cutâneas/diagnóstico , Neoplasias Cutâneas/epidemiologia , Adulto , Idoso , Biópsia por Agulha , Dermoscopia/normas , Dermoscopia/tendências , Detecção Precoce de Câncer/tendências , Educação Médica Continuada , Feminino , Previsões , Promoção da Saúde/organização & administração , Humanos , Masculino , Programas de Rastreamento/normas , Programas de Rastreamento/tendências , Microscopia Confocal/normas , Microscopia Confocal/tendências , Pessoa de Meia-Idade , Educação de Pacientes como Assunto , Guias de Prática Clínica como Assunto , Programa de SEER , Análise Espectral/normas , Análise Espectral/tendências , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA