Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 216
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Sleep Breath ; 28(2): 835-839, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38102507

RESUMO

PURPOSE: In patients diagnosed with obstructive sleep apnea (OSA), continuous positive airway pressure therapy (CPAP) is effective in reducing symptoms and improving quality of life. However, poor mid- to long-term adherence and high termination rates are a problem. We asked whether or not patient motivation at CPAP initiation was associated with 15-day and 1-year CPAP adherence and termination rates. METHODS: In this nationwide multicenter observational study, individual patient motivation for achieving CPAP adherence was subjectively evaluated at the time of CPAP set-up by the home-care provider's technician on a simple scale (low, average, good, very good). Then, adherence and CPAP termination rates were objectively monitored via the home-care provider's CPAP remote monitoring platform at 15 days and 1 year. RESULTS: A total of 10,450 adults with OSA initiating CPAP were included by 36 centers. CPAP adherence at day 15 was significantly different between the low and the very good motivation groups: 5.4 [3.2; 6.9] hours and 6.0 [4.2; 7.3] hours per night respectively. In the 72.0% of patients using CPAP at 1 year, CPAP adherence was 5.2 [3.1; 6.7] and 5.5 [4.0; 7.0] hours per night in the groups with low and very good motivation respectively. Therapy termination rates at 1 year were 14.6% in the low motivation group and 8.0% in the very good motivation group. CONCLUSION: Our study suggests that motivation of patients with OSA estimated by caregivers at CPAP initiation using a simple four-item ranking is associated with CPAP adherence and primary therapy termination rates during the first year of treatment.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Motivação , Cooperação do Paciente , Apneia Obstrutiva do Sono , Humanos , Pressão Positiva Contínua nas Vias Aéreas/psicologia , Apneia Obstrutiva do Sono/terapia , Masculino , Feminino , Pessoa de Meia-Idade , Cooperação do Paciente/psicologia , Idoso , Adulto , Cuidadores/psicologia
2.
Nurs Health Sci ; 26(2): e13129, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38781983

RESUMO

Adherence to continuous positive airway pressure (CPAP) in patients with obstructive sleep apnea (OSA) post-stroke is often problematic, despite potential benefits. This study aimed to evaluate CPAP adherence in patients with OSA post-stroke based on the Andersen behavioral model of health services utilization. A total of 227 eligible participants were recruited from a Chinese hospital. After baseline assessment, participants were followed for 6 months to determine short-term CPAP adherence. Those with good short-term adherence were followed for an additional 6 months to explore long-term adherence and influencing factors. Short-term CPAP adherence rate was 33%. Being married or living with a partner, having an associate degree or baccalaureate degree or higher, and stronger health beliefs independently predicted short-term CPAP adherence. Only 25% of participants from the adherent group showed good long-term adherence. The factor associated with long-term CPAP adherence was participants not using alcohol. Adherence to CPAP is suboptimal among patients having OSA post-stroke. Addressing unfavorable predisposing factors and modifying health beliefs are suggested.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Cooperação do Paciente , Apneia Obstrutiva do Sono , Acidente Vascular Cerebral , Humanos , Pressão Positiva Contínua nas Vias Aéreas/métodos , Pressão Positiva Contínua nas Vias Aéreas/psicologia , Pressão Positiva Contínua nas Vias Aéreas/estatística & dados numéricos , Masculino , Apneia Obstrutiva do Sono/psicologia , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/complicações , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Cooperação do Paciente/estatística & dados numéricos , Cooperação do Paciente/psicologia , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/psicologia , Idoso , China , Inquéritos e Questionários
3.
J Med Internet Res ; 25: e40193, 2023 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-37213195

RESUMO

BACKGROUND: Many people worldwide experience obstructive sleep apnea, which is associated with medical and psychological problems. Continuous positive airway pressure (CPAP) is an efficacious therapy for obstructive sleep apnea, but its effect is limited by nonadherence. Studies show that personalized education and feedback can increase CPAP adherence. Moreover, tailoring the style of information to the psychological profile of a patient has been shown to enhance the impact of interventions. OBJECTIVE: This study aimed to assess the effect of an intervention providing digitally generated personalized education and feedback on CPAP adherence and the additional effect of tailoring the style of the education and feedback to an individual's psychological profile. METHODS: This study was a 90-day, multicenter, parallel, single-blinded, and randomized controlled trial with 3 conditions: personalized content in a tailored style (PT) in addition to usual care (UC), personalized content in a nontailored style (PN) in addition to UC, and UC. To test the effect of personalized education and feedback, the PN + PT group was compared with the UC group. To test the additional effect of tailoring the style to psychological profiles, the PN and PT groups were compared. Overall, 169 participants were recruited from 6 US sleep clinics. The primary outcome measures were adherence based on minutes of use per night and on nights of use per week. RESULTS: We found a significant positive effect of personalized education and feedback on both primary adherence outcome measures. The difference in the estimated average adherence based on minutes of use per night between the PT + PN and UC groups on day 90 was 81.3 minutes in favor of the PT + PN group (95% CI -134.00 to -29.10; P=.002). The difference in the average adherence based on nights of use per week between the PT + PN and UC groups at week 12 was 0.9 nights per week in favor of the PT + PN group (difference in odds ratio 0.39, 95% CI 0.21-0.72; P=.003). We did not find an additional effect of tailoring the style of the intervention to psychological profiles on the primary outcomes. The difference in nightly use between the PT and PN groups on day 90 (95% CI -28.20 to 96.50; P=.28) and the difference in nights of use per week between the PT and PN groups at week 12 (difference in odds ratio 0.85, 95% CI 0.51-1.43; P=.054) were both nonsignificant. CONCLUSIONS: The results show that personalized education and feedback can increase CPAP adherence substantially. Tailoring the style of the intervention to the psychological profiles of patients did not further increase adherence. Future research should investigate how the impact of interventions can be enhanced by catering to differences in psychological profiles. TRIAL REGISTRATION: ClinicalTrials.gov NCT02195531; https://clinicaltrials.gov/ct2/show/NCT02195531.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Apneia Obstrutiva do Sono , Humanos , Pressão Positiva Contínua nas Vias Aéreas/métodos , Pressão Positiva Contínua nas Vias Aéreas/psicologia , Retroalimentação , Apneia Obstrutiva do Sono/terapia , Sono , Cooperação do Paciente/psicologia
4.
Sleep Breath ; 25(2): 627-637, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32705529

RESUMO

BACKGROUND: Continuous positive airway treatment (CPAP) is first-line treatment for obstructive sleep apnea (OSA), but adherence tends to be low. A clinical tool focusing on motivation to use CPAP is missing. The purpose was to develop a brief questionnaire to assess motivation to use CPAP that is psychometrically robust and suitable for use in clinical practice. METHODS: A convenience sample including 193 treatment naive patients with OSA (67% men; mean age = 59.7 years, SD 11.5) from two CPAP clinics was used. Clinical assessments and full night polygraphy were performed. Questionnaires administered before CPAP treatment included the newly developed Motivation to Use CPAP Scale (MUC-S), Minimal Insomnia Symptoms Scale (MISS), Epworth Sleepiness Scale (ESS), and Attitude towards CPAP treatment Inventory (ACTI). The validity and reliability of the MUC-S were investigated using Rasch and exploratory factor analysis models. Measurement invariance, dimensionality and differential item functioning (i.e., across gender groups, excessive daytime sleepiness (ESS), insomnia (MISS) and attitude towards CPAP (ACTI) groups) were assessed. RESULTS: The results supported a two-factor solution (autonomous motivation, 6 items, factor loadings between 0.61 and 0.85 and controlled motivation, 3 items, factor loadings between 0.79 and 0.88) explaining 60% of the total variance. The internal consistency was good with Cronbach's alpha of 0.88 and 0.86 for the two factors. No differential item functioning was found. A latent class analysis yielded three profiles of patients with high (n = 111), moderate (n = 60) and low (n = 22) motivation. Patients with high motivation were older, had higher daytime sleepiness scores, more insomnia symptoms and a more positive attitude towards CPAP. CONCLUSIONS: The MUC-S seems to be a valid tool with robust psychometric properties suitable for use at CPAP clinics. Future studies should focus on how motivation changes over time and if MUC-S can predict objective long-term CPAP adherence.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/psicologia , Motivação , Apneia Obstrutiva do Sono/terapia , Inquéritos e Questionários , Idoso , Distúrbios do Sono por Sonolência Excessiva/epidemiologia , Análise Fatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Psicometria , Reprodutibilidade dos Testes
5.
Sleep Breath ; 25(2): 887-895, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33011910

RESUMO

PURPOSE: To determine the predictive factors of initial and long-term adherence to positive airway pressure (PAP) therapy and factors leading to an unfavorable shift of PAP compliance. METHODS: This follow-up study was comprised of newly diagnosed patients with obstructive sleep apnea (OSA) amenable to PAP therapy from January 2017 to April 2019. Information on basic demographics, comorbidities, and sleep-related symptoms were collected. PAP adherence data were collected at the end of the first week and the third month. RESULTS: Of 166 patients enrolled, data from 142 (86%) were in the final analysis. Overall PAP usage was worse at 3 months declining from the first week. After adjusting for age and gender, multinomial logistic regression analysis showed that a small number of sleep-related symptoms (OR, 0.69; 95% CI, 0.52-0.91) and low arousal threshold (ArTH) (OR, 4.44; 95% CI, 1.52-12.98) were associated with higher odds of noncompliance. Low ArTH (OR, 2.87; 95% CI, 1.09-7.57) and lower body mass index (BMI) (OR, 0.88; 95% CI, 0.78-0.99) increased the risk of compliance-to-noncompliance shift. Sixty-two patients with polysomnography were analyzed separately. After adjustment for age and gender, poor sleep efficiency (OR, 0.80; 95% CI, 0.68-0.94) was associated with higher odds of consistent noncompliance. Low ArTH (OR, 15.36; 95% CI, 1.44-164.24) increased the risk of compliance-to-noncompliance shift in this subgroup. CONCLUSIONS: Lower BMI and low ArTH were associated with an unfavorable shift of PAP compliance over time in patients with OSA, which was different from the predictors of consistent PAP noncompliance of patients with OSA.


Assuntos
Nível de Alerta , Pressão Positiva Contínua nas Vias Aéreas/psicologia , Cooperação do Paciente/psicologia , Apneia Obstrutiva do Sono/terapia , Adulto , Índice de Massa Corporal , Pressão Positiva Contínua nas Vias Aéreas/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente/estatística & dados numéricos , Polissonografia , Limiar Sensorial
6.
Sleep Breath ; 25(3): 1277-1283, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33098538

RESUMO

PURPOSE: The objective was to assess the effect of continuous positive airway pressure (CPAP) on symptoms of anxiety and depression in patients with obstructive sleep apnea (OSA). We hypothesized a decrease in symptoms at follow-up, but that improvement relied on CPAP adherence. METHODS: The sample comprised 468 patients (mean age 55.5 years (SD = 12.0), 72% men) with OSA who received CPAP at a Norwegian hospital. OSA was diagnosed according to standard respiratory polygraphy. Mean baseline respiratory event index (REI) was 28.4 (SD = 20.6). Symptoms of anxiety and depression were assessed prior to CPAP treatment and at follow-up after a median of 20 weeks, range 6-52 weeks, with the Hospital Anxiety and Depression Scale (HADS). Patients were classified as CPAP adherent (≥ 4 h per night) or non-adherent (< 4 h per night). RESULTS: There was a significant decrease in anxiety scores from baseline (mean = 5.16, SD = 3.94) to follow-up (mean = 4.76, SD = 3.81), p < 0.001. Similarly, depression scores decreased from baseline (mean = 4.31, SD = 3.66) to follow-up (mean = 3.89, SD = 3.69), p < 0.001. Cohen's d (0.19 and 0.18, respectively) indicated small effect sizes. The reduction in anxiety scores did not depend on CPAP adherence (no interaction effect F(1, 466) = 0.422, p = 0.516), whereas the reduction in depression scores were seen only in the CPAP adherent group (interaction effect F(1, 466) = 7.738, p = 0.006). CONCLUSIONS: We found a decrease in symptoms of anxiety and depression from baseline to follow-up of CPAP treatment. The improvement in symptoms of depression was depending on CPAP adherence. This underlines the importance of adherence for optimal effect of CPAP treatment.


Assuntos
Ansiedade/epidemiologia , Pressão Positiva Contínua nas Vias Aéreas/psicologia , Depressão/epidemiologia , Apneia Obstrutiva do Sono/terapia , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente/psicologia , Cooperação do Paciente/estatística & dados numéricos , Apneia Obstrutiva do Sono/psicologia , Resultado do Tratamento
7.
Sleep Breath ; 24(1): 183-190, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31069649

RESUMO

BACKGROUND: Poor adherence to continuous positive airway pressure (CPAP) remains the greatest obstacle to effective treatment of obstructive sleep apnea-hypopnea syndrome (OSAHS). The purpose of the present study was to identify if mindfulness is associated with CPAP adherence of OSAHS patients. METHODS: Newly diagnosed patients with OSAHS completed questionnaires including the Epworth Sleepiness Scale (ESS), the Mindful Attention Awareness Scale (MAAS), and the Hospital Anxiety and Depression Scale (HADS) and had experienced an overnight CPAP titration. Participants returned to the sleep center for a scheduled research visit after 30-day CPAP treatment at home. Demographics, disease severity, and device-related variables were collected. Multiple linear regression analysis was performed to build a multivariate predictive model for the outcome variable, mean daily CPAP use over 30 days. RESULTS: Mean CPAP use was 4.7 ± 2.4 h/night for the study sample of 100 patients and 67% were classified as CPAP adherent. MAAS scale was 45.2 ± 18.8, whereas only 13% of patients expressed anxiety or depression. MAAS scales were significantly higher in the CPAP adherent group compared to the non-adherent group (49.5 ± 14.5 vs 40.8 ± 14.2, p < 0.001) with mean hours of daily CPAP use over 30 days for the adherent group (5.7 ± 1.4 h/night) compared to the non-adherence group (3.0 ± 1.7 h/night). There were differences between the two groups in HADS depression, AHI, lowest SaO2, optimal CPAP pressure, residual AHI, mean days over 30 days, and mean daily CPAP use in the first week. Univariate analyses identified an unadjusted association between mean daily CPAP use over 30 days and HADS depression, MAAS, AHI, lowest SaO2, optimal pressure, and mean daily CPAP use in the first week. Multiple linear regression analysis demonstrated only MAAS and AHI were associated (p < 0.05) with mean daily CPAP use. MAAS and AHI uniquely explained 10.1% (p < 0.001) and 8.7% (p < 0.001) of mean daily CPAP use respectively. CONCLUSIONS: This study found a significant independent association of dispositional mindfulness with CPAP adherence. As a novel factor, mindfulness may play an important role in CPAP adherence.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/psicologia , Atenção Plena , Cooperação do Paciente/psicologia , Apneia Obstrutiva do Sono/psicologia , Apneia Obstrutiva do Sono/terapia , Adulto , Ansiedade/diagnóstico , Ansiedade/psicologia , Correlação de Dados , Depressão/diagnóstico , Depressão/psicologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Apneia Obstrutiva do Sono/diagnóstico , Inquéritos e Questionários
8.
Sleep Breath ; 23(3): 753-759, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30685849

RESUMO

BACKGROUND: The objective of this prospective study was to assess the effect of CPAP therapy on job productivity and work quality for patients with severe obstructive sleep apnea (OSA). METHODS: A convenience sample of patients diagnosed with severe OSA using polysomnography or polygraphy and with a therapeutic indication for CPAP was enrolled in our study. Patients completed two self-administered questionnaires: the first before CPAP therapy and the second during the first 6 months after CPAP treatment. OSA symptoms were evaluated through self-administered questionnaires assessing potential effects on occupational activity: excessive daytime sleepiness was rated by the Epworth Sleepiness Scale (ESS), emotional status was rated by the Hospital Anxiety and Depression (HAD) scale, work quality was rated by the Work Role Functioning Questionnaire (WRFQ). RESULTS: Forty patients (30 men, mean age 47.3 ± 8.3, mean BMI 31.6 ± 7.4, mean apnea-hypopnea index 51.8 ± 16.3) showed a beneficial effect of CPAP therapy on ESS score (mean 11.6 to 8.2, p < 0.0001), the anxiety dimension (mean 57.5% to 20%, p = 0.0002), and the overall anxiety-depressive score (mean 50% to 22.5%, p = 0.0006). Mean WRFQ scores were significantly improved in the second questionnaire for the dimensions of timetable requirements (69.3% to 83.5%, p < 0.0001), productivity requirements (71.4% to 82.2%, p < 0.0001), mental requirements (72.0% to 84.3%, p < 0.0001), and social requirements (82.6% to 91.4%, p < 0.003). CONCLUSIONS: We observed that adherence to CPAP therapy for patients with severe OSA mitigates the impact of symptoms on work including excessive daytime sleepiness, impairment of work ability, and anxiety and depressive disorders.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Qualidade de Vida/psicologia , Apneia Obstrutiva do Sono/psicologia , Apneia Obstrutiva do Sono/terapia , Atividades Cotidianas/psicologia , Adulto , Pressão Positiva Contínua nas Vias Aéreas/psicologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente , Polissonografia , Estudos Prospectivos
9.
Sleep Breath ; 23(2): 575-578, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30685850

RESUMO

PURPOSE: In children, the usual indications for continuous positive airway pressure (CPAP) are residual OSA after adenotonsillectomy and/or persistent OSA due to obesity. Data concerning adherence (hours/night) following ambulatory CPAP initiation are scarce. METHODS: An observational cohort of 78 children was followed over 2 years. All exhibited sleep-disordered breathing (SDB) symptoms, were assessed by polysomnography, and prescribed CPAP. CPAP was initiated at hospital for 10 children. RESULTS: OSA children, mean age 10.4 ± 3.2 years, were mostly males (75.6%), with a mean body mass index of 21.2 ± 7.3 kg/m2, and mean apnea+hypopnea index of 12.2 ± 10.6 events/hour. Seventy-two children were still on CPAP at 3 months, 63 at 6 months, 55 at 1 year, and 34 at 2 years. CPAP was discontinued thanks to rehabilitation programs, dento-facial orthopedics, and/or weight loss. Mean CPAP adherence at 1, 3, 6, 12, and 24 months was respectively 6.1 ± 2.8, 6.2 ± 2.6, 6.2 ± 2.8, 6.3 ± 2.8, and 7.0 ± 2.7 h/night. There was a trend towards higher CPAP adherence and younger age, primary versus middle/high school attendance, higher baseline apnea+hypopnea index, and neurocognitive disorders. CONCLUSION: In our population, mean CPAP adherence defined in hours per night was high and did not decrease during the 24-month follow-up. These findings support the feasibility of ambulatory CPAP initiation in non-syndromic OSA. The high CPAP adherence is expected to be associated with improvements in neurocognition, and in metabolic and cardiovascular parameters.


Assuntos
Assistência Ambulatorial/psicologia , Pressão Positiva Contínua nas Vias Aéreas/psicologia , Assistência de Longa Duração/psicologia , Cooperação do Paciente/psicologia , Apneia Obstrutiva do Sono/psicologia , Apneia Obstrutiva do Sono/terapia , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Polissonografia
10.
Sleep Breath ; 23(3): 761-768, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30523558

RESUMO

BACKGROUND: Continuous positive airway treatment (CPAP) is the recommended treatment for patients with obstructive sleep apnea (OSA). Outcome measures often focus on clinical and/or self-rated variables related to the medical condition. However, a brief validated instrument focusing on the whole life situation (i.e., ethos) suitable for clinical practice is missing. The aim of this study was to investigate factorial structure, categorical functioning of the response scale, and differential item functioning across sub-populations of the Ethos Brief Index (EBI) among patients with obstructive sleep apnea (OSA) before and after initiation of continuous positive airway pressure (CPAP). METHODS: A prospective design, including 193 patients with OSA (68% men, 59.66 years, SD 11.51) from two CPAP clinics, was used. Clinical assessment and overnight respiratory polygraphy were used to diagnose patients. Questionnaires administered before and after 6 months of CPAP treatment included EBI, Epworth Sleepiness Scale (ESS), Hospital Anxiety and Depression Scale, and global perceived health (initial item in SF-36). The validity and reliability of the EBI were investigated using Rasch and confirmatory factor analysis models. Measurement invariance, unidimensionality, and differential item functioning across gender groups, Apnea-Hypopnea Index, and ESS groups were assessed. RESULTS: The reliability of the EBI was confirmed using composite reliability and Cronbach's alpha. The results supported unidimensionality of the EBI in confirmatory factor analysis and the Rasch model. No differential item functioning was found. A latent profile analysis yielded two profiles of patients with low (n = 42) and high (n = 151) ethos. Patients in the low ethos group were younger and had higher depression scores, lower perceived health, and higher body mass index. CONCLUSIONS: The EBI is a valid tool with robust psychometric properties suitable for use among patients with OSA before and after treatment with CPAP is initiated. Future studies should focus on its predictive validity.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/psicologia , Qualidade de Vida/psicologia , Apneia Obstrutiva do Sono/terapia , Inquéritos e Questionários/normas , Adulto , Pressão Positiva Contínua nas Vias Aéreas/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente , Polissonografia , Estudos Prospectivos , Psicometria , Reprodutibilidade dos Testes , Apneia Obstrutiva do Sono/psicologia , Resultado do Tratamento
11.
Sleep Breath ; 23(1): 217-226, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29946945

RESUMO

PURPOSE: The Self-Efficacy Measure for Sleep Apnea (SEMSA) is a 26-item self-questionnaire composed of three factors: risk perception of obstructive sleep apnea syndrome (OSAS), benefit of continuous positive airway pressure (CPAP), and self-efficacy (the confidence to engage in CPAP use). It is used to evaluate health beliefs about OSAS and CPAP in order to optimize CPAP use. The purpose of this study was to design and validate a French version of the SEMSA. METHODS: A forward-backward translation of the SEMSA was performed. Subjects with OSAS treated by CPAP and followed by our sleep clinic were invited to complete the questionnaire. The psychometric properties of the French SEMSA version were analyzed in terms of its construct validity (with confirmatory factor analysis, CFA), internal structural validity (Cronbach's alpha coefficient), and external validity (Pearson's correlation between SEMSA score and duration of CPAP use). RESULTS: Two hundred eighty-eight subjects filled in the questionnaire. The mean age was 63.16 ± 12.73 years. The number of years since the beginning of CPAP treatment was 6.58 ± 6.03 years. The mean CPAP use duration was 6.19 ± 2.03 h/night. CFA was unsatisfactory (RMSEA = 0.066 and CFI = 0.88). The exploratory factor analysis revealed a fourth factor named "cardiovascular risk" factor. Cronbach's alpha coefficient was 0.886. The correlation between the "self-efficacy" factor and the duration of CPAP use was significant (r = 0.26, p ≤ 0.001). CONCLUSIONS: The French version of the SEMSA is a psychometrically acceptable self-report questionnaire for measuring health beliefs and behavior in French patients with OSAS treated with CPAP. Such translation and validation should lead to the adoption of validated psychosocial methods for improving CPAP use.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/psicologia , Autoeficácia , Apneia Obstrutiva do Sono/psicologia , Apneia Obstrutiva do Sono/terapia , Inquéritos e Questionários/estatística & dados numéricos , Idoso , Atitude Frente a Saúde , Doenças Cardiovasculares/prevenção & controle , Doenças Cardiovasculares/psicologia , Correlação de Dados , Comparação Transcultural , Cultura , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente/psicologia , Psicometria/estatística & dados numéricos , Medição de Risco
12.
Behav Sleep Med ; 17(1): 49-69, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-28128977

RESUMO

OBJECTIVE/BACKGROUND: Positive airway pressure (PAP) is highly efficacious treatment but nonadherence is prevalent with little improvement over the last 15 years. Tailored interventions show promise for promoting adherence to other treatments. The study objective was to examine feasibility and acceptability of a tailored intervention to promote PAP adherence. PARTICIPANTS: The convenience sample met inclusion criteria: newly diagnosed OSA; treatment-naïve; ≥ 18 years. EXCLUSION CRITERIA: previous obstructive sleep apnea (OSA) diagnosis and treatment; new psychiatric diagnosis; use of oxygen/bilevel PAP; secondary sleep disorder. Adults (n = 118) were randomized to tailored intervention (TI; n = 61) or usual care (UC; n = 57); application of a priori exclusion criteria resulted in 30 participants per assignment who were middle-aged (51.3 ± 11.1 years) adults (70% male) with severe OSA (apnea hypopnea index [AHI], 35.9 ± 25.2). METHODS: Randomized, double-blind, single-site pilot controlled trial. A multiphased tailored intervention targeting social cognitive perceptions of OSA-PAP treatment was delivered at four intervals. Descriptive analysis, group differences, and self-efficacy change scores by t-test, and thematic analysis of acceptability data are reported. RESULTS: One-week PAP use among TI was 35 min greater than UC condition (p = 0.20; Cohen's d = 0.336). Treatment use decreased at 1 month and 3 months (NS). Per-protocol delivery of face-to-face intervention delivery was 100% but lower for telephone intervention delivery. Personalized approach was valued by participants. CONCLUSIONS: A tailored intervention approach is acceptable to participants and feasibly implemented in a clinical sleep center setting. The intervention effect size at 1 week is consistent with other educational PAP adherence interventions but was not sustained; further pilot testing is warranted to address pilot RCT limitations.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Polissonografia/métodos , Apneia Obstrutiva do Sono/diagnóstico , Pressão Positiva Contínua nas Vias Aéreas/psicologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Apneia Obstrutiva do Sono/patologia , Apneia Obstrutiva do Sono/terapia
13.
Behav Sleep Med ; 17(3): 238-245, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-28557581

RESUMO

OBJECTIVE/BACKGROUND: Improvement is sought for youth with obstructive sleep apnea syndrome (OSAS) who have poor quality of life (QoL), which resolves somewhat following treatment. One mitigating factor in improved QoL following treatment may be adherence to the CPAP protocol, which presents a barrier to most youth. This study explored relations between CPAP adherence and QoL in youth with OSAS. PARTICIPANTS: We recruited 42 youth-caregiver dyads in which youth between the ages of 8 and 16 years were diagnosed with OSAS and required CPAP use as part of their treatment plan. METHODS: Following diagnosis of OSAS requiring treatment with CPAP therapy, caregivers completed baseline measures of OSAS-specific QoL. The OSAS-specific QoL domains assessed included sleep disturbance, physical symptoms, emotional distress, daytime function, and caregiver concern. Families received routine CPAP care for three months, after which caregivers again completed measures of OSAS-specific QoL. Adherence data were collected from smartcards within the CPAP machine after three months of treatment. RESULTS: Fifteen youth were adherent to CPAP therapy and 10 were not adherent. CPAP-adherent youth demonstrated significant changes in two domains of OSAS-specific QoL when compared to nonadherent youth: decreased sleep disturbance and decreased caregiver concern. CONCLUSIONS: CPAP adherence appears to be associated with positive changes in OSAS-specific QoL domains. It will be important for future research and clinical work to examine strategies for improving CPAP adherence in youth with OSAS.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Qualidade de Vida/psicologia , Apneia Obstrutiva do Sono/psicologia , Apneia Obstrutiva do Sono/terapia , Adolescente , Criança , Pressão Positiva Contínua nas Vias Aéreas/psicologia , Feminino , Humanos , Masculino , Inquéritos e Questionários
14.
Spinal Cord ; 57(3): 247-254, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30356181

RESUMO

STUDY DESIGN: Mixed methods OBJECTIVES: Continuous positive airway pressure (CPAP) therapy is the recommended treatment for obstructive sleep apnoea (OSA). The aim of this study was to estimate CPAP adherence in people with tetraplegia and OSA, and to explore the barriers and facilitators to CPAP use. SETTING: Hospital outpatient department in Melbourne, Australia METHODS: People with chronic tetraplegia and OSA were commenced with auto-titrating CPAP and supported for 1 month. Semi-structured interviews were conducted with participants at one month and analysed thematically. CPAP usage was measured at 1, 6 and 12 months, with "adherent" defined as achieving more than 4 h average per night. RESULTS: Sixteen participants completed the study (80% male; mean age 56 (SD = 15)). Mean nightly CPAP use at one month was 3.1 h (SD = 2.5; 38% adherent), and at 6 months and 12 months were 2.6 h (SD = 2.8; 25% adherent) and 2.1 h (SD = 3.2; 25% adherent). The perceived benefit/burden balance strongly influenced ongoing use. Burden attributed to CPAP use was common, and included mask discomfort, and physical and emotional problems. Adherent participants were motivated by the immediate daytime benefits to mood, alertness and sleepiness. There was a tendency to not recognise symptoms of OSA until after they were treated. CONCLUSION: CPAP use is challenging for people with tetraplegia, who experience substantial burden from using the device. When tolerated, the proximate benefits are substantial. People with tetraplegia need more intensive support for longer to help them overcome the burdens of CPAP and benefit from the treatment.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Quadriplegia/complicações , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/terapia , Assistência Ambulatorial , Doença Crônica , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Pressão Positiva Contínua nas Vias Aéreas/psicologia , Feminino , Humanos , Entrevistas como Assunto , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente , Satisfação do Paciente , Quadriplegia/psicologia , Pesquisa Qualitativa , Apneia Obstrutiva do Sono/psicologia , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/psicologia , Fatores de Tempo , Resultado do Tratamento
15.
Sleep Breath ; 22(2): 369-376, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28856525

RESUMO

PURPOSE: Patient adherence with positive airway pressure (PAP) therapy is a significant clinical problem in obstructive sleep apnea treatment. Personality traits may be a factor for non-adherence. The aim of this study is to investigate the relationship between PAP therapy adherence and patient personality traits. METHODS: Patients were screened and recruited during their visit to a sleep clinic. Baseline data were collected from each patient's electronic chart. Behavioral inhibition system/behavioral activation system (BIS/BAS) scales, short measure of five-factor model personality traits (mini-IPIP), positive and negative affect score (PANAS), and appetitive motivation scores (AMS) tests were used to measure personality traits. Data from the PAP device were obtained following a minimum of an initial 30 days, with adherence defined as >4 h/night on 70% of nights. Univariate and multivariate logistic regression and Pearson correlation tests were used to analyze the data. RESULTS: A total of 400 patients were recruited. Three hundred twenty-one patients had all the data and were included in the study. Behavioral activation system-fun seeking (BAS-FS) and, to a certain extent, negative affect were significantly associated with adherence. Intellect/imagination was marginally significant. Additionally, older age (>65 years), profession, PAP type, side effects, efficiency, apnea-hypopnea index (AHI), and residual AHI showed significant associations with patient adherence with PAP therapy. Multivariate analysis revealed that BAS-FS was still a significant predictor of adherence even after adjusting for other covariates. CONCLUSION: BAS-FS, negative affect, and intellect/imagination are significant factors for adherence to PAP therapy in obstructive sleep apnea patients.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/psicologia , Cooperação do Paciente/psicologia , Personalidade , Apneia Obstrutiva do Sono/psicologia , Apneia Obstrutiva do Sono/terapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Estudos Prospectivos
16.
Sleep Breath ; 21(1): 3-8, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27392419

RESUMO

OBJECTIVES: The purpose of the study was to conduct a systematic review and meta-analysis in patients with obstructive sleep apnea (OSA), evaluating effects of topical nasal steroids on continuous positive airway pressure (CPAP) machine use and nasal symptoms. SEARCH METHODS: Data source: A comprehensive search of Pubmed, Scopus, Web of Science, and the Cochrane Library was performed through April 2016. Manual searches and subject matter expert input were also obtained. Studies assessing effects of nasal steroids on CPAP machine use in adults, which reported quantitative outcome data of CPAP compliance, were included. RESULTS: Two studies (144 patients) met inclusion criteria. Both were randomized, placebo-controlled clinical trials (RCT). Pooled fixed effects analysis did not identify a statistically significant difference between both the groups for average duration of CPAP machine use per night. But there was an overall increase in the usage of 0.4 h (95 % confidence interval (CI) (-0.20, 1.00); P = 0.19) in favor of nasal steroids. Difference of percentage of nights with CPAP use was not demonstrated (mean difference 0.06, 95 % CI (-0.27, 0.39); P = 0.71). There was also no significant difference in nasal symptoms (mean difference 0.63, 95 % CI (-0.11, 1.36), P = 0.1). CONCLUSION: Nasal steroids showed benefits on CPAP use, but did not reach statistical significance. Data was based on meta-analysis of RCTs of 4-week follow-up in unselected OSA patients. Future controlled studies with selected group and longer follow-up duration are needed to confirm the benefits of nasal steroid on CPAP compliance in OSA patients.


Assuntos
Corticosteroides/administração & dosagem , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Pressão Positiva Contínua nas Vias Aéreas/psicologia , Cooperação do Paciente/psicologia , Apneia Obstrutiva do Sono/terapia , Administração Intranasal , Seguimentos , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
17.
Sleep Breath ; 21(2): 295-302, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27638725

RESUMO

PURPOSE: Obstructive sleep apnea (OSA) is associated with a range of neurocognitive and cardiovascular complications, leading to a compromised quality of life. Continuous positive airway pressure (CPAP) is the gold standard therapeutic intervention for this disorder, yet patient compliance remains essential to its success. This study aimed at identifying the determinants of short-term and long-term CPAP adherence in a group of Lebanese patients. METHODS: This cross-sectional study, conducted at the Sleep Center of Hôtel-Dieu de France hospital in Lebanon, included patients diagnosed with OSA and treated with CPAP for at least one night between June 2008 and January 2015. Adherence was assessed based on patients' self-report. RESULTS: The study enrolled 138 patients. Adherence rate was 70.3 % at 6 months and around 50 % after 5 years. Cox models showed that use of nasal masks (HR 0.48, p = 0.048) and higher oxygen desaturation index at baseline (HR 0.98 p = 0.048) were associated with a better short-term CPAP adherence. Patients who bought their devices (HR 0.18, p < 0.001), those who were frequently contacted by the CPAP provider (HR 0.85, p 0.024), and those who reported improvement on treatment (HR 0.36, p < 0.001) were significantly more likely to remain adherent on the long term. Conversely, individuals on a diet plan tended to interrupt the treatment earlier (HR 4.85, p 0.039). CONCLUSION: The present findings should be further explored in order to tailor interventions to the specific needs of different patient profiles and secure an improved CPAP adherence.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/psicologia , Cooperação do Paciente/psicologia , Apneia Obstrutiva do Sono/psicologia , Apneia Obstrutiva do Sono/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Seguimentos , Humanos , Líbano , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Resultado do Tratamento
18.
J Clin Nurs ; 26(3-4): 568-577, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27685080

RESUMO

AIMS AND OBJECTIVES: To describe facilitators and barriers from a patient perspective in communications between patients with obstructive sleep apnoea syndrome and healthcare personnel during the first meeting when continuous positive airway pressure is initiated. BACKGROUND: Adherence to continuous positive airway pressure treatment tends to be poor, especially at the initial phase of treatment. Communication between the patient and healthcare personnel has not been studied from the patient perspective, as either a barrier or facilitator for adherence. METHODS: A descriptive design using qualitative content analysis was used. Interviews with 25 patients with obstructive sleep apnoea syndrome took place after their initial visit at four continuous positive airway pressure clinics. A deductive analysis based on The 4 Habits Model (i.e. emphasise the importance of investing in the beginning of the consultation, elicit the patient's perspective, demonstrate empathy and invest in the end of the consultation) was conducted. RESULTS: Building confidence (i.e. structure building, information transfer, commitment) or hindering confidence (i.e. organisational insufficiency, stress behaviour, interaction deficit) was associated with investing in the beginning. Motivating (i.e. situational insight, knowledge transfer, practical training) or demotivating (i.e. expectations, dominance and power asymmetry, barriers) was associated with eliciting the patient's perspective. Building hope (i.e. awareness, sensitivity, demonstration of understanding) or hindering hope (i.e. unprepared, uncommitted, incomprehension) was associated with showing empathy. Agreement (i.e. confirmation, responsibilities, comprehensive information) or disagreement (i.e. structural obscurity, irresponsibility, absent-mindedness) was associated with investing in the end. CONCLUSIONS: Understanding of facilitators and barriers, as described by patients, can be used to improve contextual conditions and communication skills among healthcare personnel. RELEVANCE TO CLINICAL PRACTICE: A patient-centred communication technique should be used in relation to all stages of The 4 Habits Model to facilitate shared decision-making and improve adherence to continuous positive airway pressure treatment.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/psicologia , Educação de Pacientes como Assunto/métodos , Satisfação do Paciente , Relações Médico-Paciente , Apneia Obstrutiva do Sono/psicologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Apneia Obstrutiva do Sono/terapia , Suécia
19.
Psychol Health Med ; 22(8): 896-901, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28102087

RESUMO

In the field of sleep disorders, the quality of couple relationship is arousing increasing attention, given its implications for quality of life and treatment adherence. The aim of the present study was to evaluate relationship quality in a sample of treated or untreated patients with Obstructive Sleep Apnoea Syndrome. Eighty-seven patients were recruited in a hospital-based Centre for Sleep Medicine. Subjects were administered the Dyadic Adjustment Scale (DAS) to evaluate relationship quality, and the Epworth Sleepiness Scale (ESS). Apnoea-hypopnoea indexes (AHI) were collected through nocturnal polysomnography or home testing with a portable monitoring device. Although the DAS average scores were similar to local normative values, relationship quality was significantly lower in the untreated patients when compared with the ones treated. The ESS scores showed a negative correlation with many DAS scores, whereas no significant correlation emerged for AHI. Such data suggest a significant impact of perceived sleep apnoea symptoms on marital satisfaction, even though in the absence of striking differences between the whole sample and the general population.


Assuntos
Casamento , Qualidade de Vida/psicologia , Apneia Obstrutiva do Sono/psicologia , Adulto , Idoso , Pressão Positiva Contínua nas Vias Aéreas/psicologia , Distúrbios do Sono por Sonolência Excessiva/psicologia , Distúrbios do Sono por Sonolência Excessiva/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Psicometria/estatística & dados numéricos , Apneia Obstrutiva do Sono/terapia , Inquéritos e Questionários
20.
Sleep Breath ; 20(4): 1255-1261, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27193744

RESUMO

PURPOSE: Upper airway symptom associated with continuous positive airway pressure (CPAP) treatment is an important factor influencing CPAP adherence. There are conflicting data on the effect of a heated humidifier (HH) during CPAP titration for patients with obstructive sleep apnea hypopnea syndrome (OSAHS). This study investigated the effects of HH during CPAP titration in the cool sleeping environment. METHODS: Forty newly diagnosed OSAHS patients who received CPAP titration in the cool sleeping environment were randomly assigned to HH and non-HH groups. A questionnaire was used to evaluate upper airway symptoms, satisfaction with initial CPAP treatment, and willingness to further use CPAP. Some therapy parameters including leak, apnea hypopnea index (AHI) reduction, and optimal CPAP pressure level were analyzed. We compared these subjective and objective data between the two groups. RESULTS: In subjective sensation, the use of HH can alleviate upper airway symptoms associated with CPAP titration (P < 0.001). The HH group has benefit in satisfaction with initial CPAP treatment (P < 0.001) and further willingness to use CPAP (P < 0.01), although there were no significant differences in leak, AHI reduction, and optimal CPAP pressure between the two groups. CONCLUSIONS: The use of HH is recommended during CPAP titration in the cool sleeping environment because of its benefit in the treatment of upper airway symptoms associated with CPAP therapy and improvement of the CPAP acceptance.


Assuntos
Temperatura Baixa , Pressão Positiva Contínua nas Vias Aéreas/métodos , Apneia Obstrutiva do Sono/terapia , Adulto , Calibragem , China , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/psicologia , Feminino , Calefação , Humanos , Umidificadores , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente , Satisfação do Paciente , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/psicologia , Fases do Sono
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA