Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.018
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Pediatr Transplant ; 28(4): e14776, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38778714

RESUMO

BACKGROUND: It is essential to have an accurate assessment of the renal function of patients with chronic kidney disease to monitor, treat, and predict further development of the condition. Measurement of renal function in terms of glomerular filtration rate (GFR) requires either urine or blood sampling, but especially in children, more simple methods of measurement are preferable. The main objective of this study was to examine if the estimated GFR (eGFR) calculated with different cystatin-C-based equations was comparable to the GFR measured by a radiotracer (mGFR) in pediatric patients. METHODS: In this retrospective study, 28 pediatric patients contributed with 73 pairs of measurements collected within 5 years. Bland-Altman Limits of Agreement were used to evaluate the performance and accuracy of two different cystatin-C-based estimates, the CKiDCrea-CysC and the CKiDU25 respectively, compared to an mGFR based on plasma clearance of technetium-99m-diethylenetriaminepentaacetic acid or chromium-51-ethylenediaminetetraacetic acid. RESULTS: Using the CKiDCrea-CysC equation, 58.9% of the datasets were within P10 and 87.7% were within P30. The mean difference was 4.8 mL/min/1.73m2 (standard deviation: 8.5 mL/min/1.73m2) and tended to overestimate GFR and thereby overrate the kidney function within the entire GFR range. Using the CKiDU25 equation, 53.4% were within P10 and 93.2% within P30. The mean difference was -2.9 mL/min/1.73m2 (standard deviation: 8.4 mL/min/1.73m2), but the difference varied with the GFR value. CONCLUSIONS: A cystatin-C-based eGFR provides a viable substitute for monitoring renal function in pediatric patients with chronic kidney disease. However, it has a lower accuracy than mGFR and can therefore not replace mGFR in clinical use.


Assuntos
Cistatina C , Taxa de Filtração Glomerular , Insuficiência Renal Crônica , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Radioisótopos de Cromo , Cistatina C/sangue , Testes de Função Renal/normas , Insuficiência Renal Crônica/fisiopatologia , Estudos Retrospectivos , Pentetato de Tecnécio Tc 99m
2.
Am J Kidney Dis ; 77(5): 673-683.e1, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33301877

RESUMO

RATIONALE AND OBJECTIVE: Glomerular filtration rate (GFR) estimation based on creatinine and cystatin C (eGFRcr-cys) is more accurate than estimated GFR (eGFR) based on creatinine or cystatin C alone (eGFRcr or eGFRcys, respectively), but the inclusion of creatinine in eGFRcr-cys requires specification of a person's race. ß2-Microglobulin (B2M) and ß-trace protein (BTP) are alternative filtration markers that appear to be less influenced by race than creatinine is. STUDY DESIGN: Study of diagnostic test accuracy. SETTING AND PARTICIPANTS: Development in a pooled population of 7 studies with 5,017 participants with and without chronic kidney disease. External validation in a pooled population of 7 other studies with 2,245 participants. TESTS COMPARED: Panel eGFR using B2M and BTP in addition to cystatin C (3-marker panel) or creatinine and cystatin C (4-marker panel) with and without age and sex or race. OUTCOMES: GFR measured as the urinary clearance of iothalamate, plasma clearance of iohexol, or plasma clearance of [51Cr]EDTA. RESULTS: Mean measured GFRs were 58.1 and 83.2 mL/min/1.73 m2, and the proportions of Black participants were 38.6% and 24.0%, in the development and validation populations, respectively. In development, addition of age and sex improved the performance of all equations compared with equations without age and sex, but addition of race did not further improve the performance. In validation, the 4-marker panels were more accurate than the 3-marker panels (P < 0.001). The 3-marker panel without race was more accurate than eGFRcys (percentage of estimates greater than 30% different from measured GFR [1 - P30] of 15.6% vs 17.4%; P = 0.01), and the 4-marker panel without race was as accurate as eGFRcr-cys (1 - P30 of 8.6% vs 9.4%; P = 0.2). Results were generally consistent across subgroups. LIMITATIONS: No representation of participants with severe comorbid illness and from geographic areas outside of North America and Europe. CONCLUSIONS: The 4-marker panel eGFR is as accurate as eGFRcr-cys without requiring specification of race. A more accurate race-free eGFR could be an important advance.


Assuntos
Negro ou Afro-Americano , Creatinina/metabolismo , Cistatina C/metabolismo , Taxa de Filtração Glomerular , Oxirredutases Intramoleculares/metabolismo , Lipocalinas/metabolismo , Insuficiência Renal Crônica/diagnóstico , População Branca , Microglobulina beta-2/metabolismo , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , População Negra , Estudos de Casos e Controles , Radioisótopos de Cromo , Ácido Edético , Feminino , Humanos , Iohexol , Ácido Iotalâmico , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/etnologia , Insuficiência Renal Crônica/metabolismo , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Adulto Jovem
3.
Transfusion ; 61(2): 393-403, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33166412

RESUMO

BACKGROUND: The purpose of our studies was to determine if fecal blood loss can provide a quantitative measure of bleeding at platelet counts of 20 000/µL or less in patients with hypoproliferative thrombocytopenia and to document the effects of different prophylactic platelet transfusion triggers on fecal blood loss. METHODS AND MATERIALS: Patients had an aliquot of their autologous red blood cells (RBCs) labeled with 51 Cr. Following reinjection of their radiolabeled RBCs, all feces and a daily blood sample were collected to determine fecal blood loss per day. Three different studies were performed in patients with thrombocytopenia: The first was in patients with thrombocytopenia with aplastic anemia who were not receiving platelet transfusions, and the other two trials involved thrombocytopenic patients with cancer who were receiving prophylactic platelet transfusions at platelet transfusion triggers of 5000/µL, 10 000/µL, or 20 000/µL. RESULTS: In patients with thrombocytopenia not receiving platelet transfusions, fecal blood loss does not increase substantially until platelet counts are 5000/µL or less. When platelet transfusions are given prophylactically to patients with cancer with chemotherapy-induced thrombocytopenia at platelet counts of 5000/µL or less, fecal blood loss and red cell transfusion requirements are the same as those for patients transfused prophylactically at higher transfusion triggers of 10 000 platelets/µL or 20 000 platelets/µL. However, the total number of platelet transfusions needed increases significantly, and the duration of the patient's thrombocytopenia tends to be longer at the higher platelet transfusion thresholds. CONCLUSION: A prophylactic platelet transfusion threshold of 5000/µL or greater is sufficient to maintain hemostasis in patients with thrombocytopenia.


Assuntos
Hemorragia Gastrointestinal/diagnóstico , Hemostasia , Sangue Oculto , Transfusão de Plaquetas , Trombocitopenia/terapia , Anemia Aplástica/sangue , Anemia Aplástica/complicações , Radioisótopos de Cromo , Contagem de Eritrócitos , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/prevenção & controle , Hemorragia/etiologia , Hemorragia/terapia , Humanos , Neoplasias/complicações , Projetos Piloto , Contagem de Plaquetas , Transfusão de Plaquetas/estatística & dados numéricos , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Risco , Trombocitopenia/sangue , Trombocitopenia/complicações
4.
Nephrol Dial Transplant ; 35(3): 519-526, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30649437

RESUMO

BACKGROUND: Renal dysfunction is a serious late complication after liver transplantation (LTX), but there are no studies addressing the early changes associated with this complication. METHODS: We prospectively studied glomerular filtration rate (GFR) before and at 1, 3 and 12 weeks after LTX using 51Cr-labelled ethylenediaminetetraacetic acid clearance in 37 adult consecutive patients who underwent non-acute first LTX. RESULTS: The mean (±SD) age was 49.5 ± 9.5 years, and the male:female sex ratio was 21:16. Diagnoses were autoimmune liver diseases (17), alcoholic cirrhosis (10) and other diseases (10). Immunosuppressive treatment consisted predominantly of triple-drug therapy. A total of 27 of the 37 patients were eligible for GFR analysis at all times. The mean (±SD) GFR was 86 ± 26 mL/min/1.73 m2 before LTX, and 77 ± 30 mL/min/1.73 m2 at 1 week, 64 ± 27 mL/min/1.73 m2 at 3 weeks and 64 ± 23 mL/min/1.73 m2 at 12 weeks after LTX, comparable to a reduction in mean GFR compared with baseline values of 10% (P = 0.1907), 25% (P = 0.0010) and 26% (P = 0.0007). Age and number of blood transfusions during surgery were identified as risk factors for this decline as well as gender, but not pre-transplant diagnosis, model of end-stage liver disease score, cold ischaemia time or post-transplant area under the curve tacrolimus during Days 0-14. CONCLUSIONS: Using measured rather than estimated GFR, our results show that severe renal impairment occurs during the first week after LTX. These results emphasize the need for more studies addressing renoprotective treatment strategies.


Assuntos
Injúria Renal Aguda/diagnóstico , Biomarcadores/metabolismo , Radioisótopos de Cromo/metabolismo , Ácido Edético/metabolismo , Transplante de Fígado/efeitos adversos , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/metabolismo , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco
5.
Scand J Clin Lab Invest ; 80(5): 408-411, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32362172

RESUMO

The issue of whether 99mTc-DTPA can replace 51Cr-EDTA for measurement of plasma clearance as a surrogate for glomerular filtration rate (GFR) is of great relevance to daily clinical practice. Prompted by the shortage of 51Cr-EDTA we conducted a head-to-head comparison in patients attending our department for GFR determination. The two tracers (3.7 MBq of 51Cr-EDTA and 8 MBq of 99mTc-DTPA) were administered intravenously immediately after each other, and the standard number of blood samples were drawn. Fifty-four patients were enrolled. In 51 of these, single-sample measurement was performed with the following results: GFREDTA was 84.6 ± 23.3 mL/min, GFRDTPA was 84.2 ± 24.7 mL/min. The mean difference was 0.4 ± 2.8 mL/min, p = 0.32, and results based on the two tracers were highly correlated (r = 0.995). GFRDTPA exceeded GFREDTA at high GFR values (difference < 0 at GFREDTA >91.4 mL/min) and vice versa (difference > 0 at GFREDTA < 91.4 mL/min). However, differences fell within few GFR units that most often will have no clinical consequence. We therefore conclude that 99mTc-DTPA can replace 51Cr-EDTA for single-sample determination of GFR in a clinical setting.


Assuntos
Ácido Edético/farmacocinética , Taxa de Filtração Glomerular/fisiologia , Renografia por Radioisótopo/métodos , Compostos Radiofarmacêuticos/farmacocinética , Pentetato de Tecnécio Tc 99m/farmacocinética , Administração Intravenosa , Idoso , Radioisótopos de Cromo , Feminino , Humanos , Rim/fisiologia , Masculino , Pessoa de Meia-Idade , Renografia por Radioisótopo/normas
6.
J Clin Pharm Ther ; 45(5): 1114-1119, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32519358

RESUMO

WHAT IS KNOWN AND OBJECTIVES: In Europe, the pharmaceutical supply of chromium-51 has been stopped. However, this isotope is necessary for the evaluation of glomerular filtration rates. It is possible to replace it with technetium-99m, but the validation of this change in the measurement method must be carried out. METHODS: A retrospective analysis of chromium-51 data from January 2018 to January 2019 was performed, followed by a study from January 2019 to January 2020 using the technetium tracer. The patients were different in the both study groups, and none had an eGFR below 50 mL min-1 . A cost analysis was performed. Patient exposure to ionizing radiation was studied for both methods. RESULTS AND DISCUSSION: Seventy-eight patients were included in the study. In total, 42 EDTA-51 Cr and 36 DTPA-99m Tc examinations were conducted and compared. There were no significant differences between the methods used to assess renal function (P = .351). The results of cost analysis and patient radiation exposure were in favour of DTPA-99m Tc examinations. WHAT IS NEW AND CONCLUSION: Within the limitations of a retrospective study of two patient cohorts, there was no significant difference between the results obtained with chromium-51 and technetium-99m tracers. In addition, with the use of DTPA-99m Tc, operating costs and patient exposure to ionizing radiation were reduced, and clinical activity was maintained for the patients' benefit. Radiopharmacists are able to react quickly to supply contingencies, reduce operating costs and maintain the quality of medical examinations.


Assuntos
Taxa de Filtração Glomerular/fisiologia , Rim/diagnóstico por imagem , Farmacêuticos/organização & administração , Serviço de Farmácia Hospitalar/organização & administração , Radioisótopos de Cromo/farmacocinética , Feminino , Humanos , Testes de Função Renal/métodos , Transplante de Rim/métodos , Doadores Vivos , Masculino , Pessoa de Meia-Idade , Papel Profissional , Compostos Radiofarmacêuticos/farmacocinética , Estudos Retrospectivos , Pentetato de Tecnécio Tc 99m/farmacocinética
7.
Ann Pharm Fr ; 78(4): 335-342, 2020 Jul.
Artigo em Francês | MEDLINE | ID: mdl-32439129

RESUMO

OBJECTIVES: Last October, the nuclear medicine departments were informed of the closure of the chromium-51 production line for clinical use. This radionuclide has different diagnostic indications in nephrology and hematology. It was therefore essential to set up alternative exploration protocols to overcome this production stoppage. METHODS: Chromium-51 EDTA has been replaced by technetium-99m DTPA for the determination of glomerular filtration rates. Sodium chromate was substituted by sodium pertechnetate for the determination of globular volumes. A retrospective analysis of the chromium-51 data was performed followed by a prospective study, from January to December 2019 for technetium tracers. RESULTS: One hundred and forty-four patients were included in the study. Forty-two EDTA-51Cr and 30 DTPA-99mTc exams were conducted and compared. There were no significant differences between the methods used to assess renal function (P=0.355). For the determination of blood cell and plasma volumes, 47 tests with 51Cr and 125I and 25 tests with 99mTc and 125I were performed and compared. There were no significant differences in the determination of total (P=0.325) and globular (P=0.148) volumes. CONCLUSIONS: The study carried out shows that there is no significant difference between the results obtained with chromium-51 and technetium tracers. As a result, clinical activity was maintained in good conditions.


Assuntos
Radioisótopos de Cromo/efeitos adversos , Medicina Nuclear/métodos , Compostos Radiofarmacêuticos/efeitos adversos , Adulto , Volume Sanguíneo , Taxa de Filtração Glomerular , Humanos , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Pentetato de Tecnécio Tc 99m
8.
Cytotherapy ; 21(5): 566-578, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30910382

RESUMO

BACKGROUND: Chimeric antigen receptor engineered T (CAR-T) cell therapy is a promising approach currently revolutionizing the field of cancer immunotherapy. However, data concerning clinical-grade CAR-T cell stability and functionality after months of cryopreservation have not been released by companies so far. To investigate the effect of cryopreservation on CAR-T cells and to further optimize the potency assays, we performed this study. METHODS: A third generation of CD19 CAR-T cells was manufactured according to Good Manufacturing Practice (GMP) requirements, which is applied to patients in an ongoing clinical phase 1 study. Quality control tests for sterility, endotoxin and mycoplasma were performed for each batch. Stability in terms of viability, recovery, transduction efficiency and functional capacity was determined using microscopy, multiparametric flow cytometry as well as chromium-51 release tests. RESULTS: Up to 90days of cryopreservation had no influence on viability, recovery and transduction efficiency of CAR-T cells. However, higher cell concentration for cryopreservation could alter the cell viability and recovery but not the transduction efficiency. Moreover, directly after thawing, both the quantity and quality of the functionality of CAR-T cells were transiently hampered by the negative effects of cryopreservation. Notably, the impaired functionality could be fully restored and even strengthened after an overnight resting process. DISCUSSION: Cryopreservation is a challenge for the functional activity of CAR-T cells. However, CAR-T cells regain their potency by overnight incubation at 37°C, which mimics the clinical application setting. Therefore, an overnight resting step should be included in in vitro potency assays.


Assuntos
Criopreservação/métodos , Receptores de Antígenos Quiméricos/genética , Linfócitos T/transplante , Antígenos CD19/imunologia , Antígenos CD19/metabolismo , Linhagem Celular Tumoral , Transplante de Células/métodos , Radioisótopos de Cromo/análise , Radioisótopos de Cromo/metabolismo , Citocinas/metabolismo , Testes Imunológicos de Citotoxicidade , Citometria de Fluxo , Humanos , Imunofenotipagem , Imunoterapia Adotiva/métodos , Controle de Qualidade , Receptores de Antígenos Quiméricos/imunologia , Linfócitos T/imunologia
9.
Transfusion ; 59(7): 2264-2275, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31002399

RESUMO

BACKGROUND: The chromium-51-labeled posttransfusion recovery (PTR) study has been the gold-standard test for assessing red blood cell (RBC) quality. Despite guiding RBC storage development for decades, it has several potential sources for error. METHODS: Four healthy adult volunteers each donated an autologous, leukoreduced RBC unit, aliquots were radiolabeled with technetium-99m after 1 and 6 weeks of storage, and then infused. Subjects were imaged by single-photon-emission computed tomography immediately and 4 hours after infusion. Additionally, from subjects described in a previously published study, adenosine triphosphate levels in transfusates infused into 52 healthy volunteers randomized to a single autologous, leukoreduced, RBC transfusion after 1, 2, 3, 4, 5, or 6 weeks of storage were correlated with PTR and laboratory parameters of hemolysis. RESULTS: Evidence from one subject imaged after infusion of technetium-99m-labeled RBCs suggests that, in some individuals, RBCs may be temporarily sequestered in the liver and spleen immediately following transfusion and then subsequently released back into circulation; this could be one source of error leading to PTR results that may not accurately predict the true quantity of RBCs cleared by intra- and/or extravascular hemolysis. Indeed, adenosine triphosphate levels in the transfusates correlated more robustly with measures of extravascular hemolysis in vivo (e.g., serum iron, indirect bilirubin, non-transferrin-bound iron) than with PTR results or measures of intravascular hemolysis (e.g., plasma free hemoglobin). CONCLUSIONS: Sources of measurement error are inherent in the chromium-51 PTR method. Transfusion of an entire unlabeled RBC unit, followed by quantifying extravascular hemolysis markers, may more accurately measure true posttransfusion RBC recovery.


Assuntos
Preservação de Sangue/métodos , Radioisótopos de Cromo , Transfusão de Eritrócitos , Eritrócitos/fisiologia , Trifosfato de Adenosina/sangue , Adulto , Armazenamento de Sangue/métodos , Transfusão de Sangue Autóloga , Feminino , Hemólise , Humanos , Fígado/fisiologia , Masculino , Pessoa de Meia-Idade , Baço/fisiologia , Tecnécio , Fatores de Tempo
10.
Scand J Clin Lab Invest ; 79(7): 463-467, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31502901

RESUMO

Both 99mTc-DTPA and 51Cr-EDTA are widely used to determine glomerular filtration rate (GFR), but few direct comparative studies exist. The shortage of 51Cr-EDTA makes a direct comparison highly relevant. The aim of the study was to investigate if there is any clinically relevant difference between plasma clearance of 99mTc-DTPA and 51Cr-EDTA. Patients ≥18 years of age referred for routine GFR measurement by 51Cr-EDTA were prospectively enrolled. The two tracers (10 MBq 99mTc-DTPA (CaNa3-DTPA) and 2.5 MBq 51Cr-EDTA) were intravenously injected at time zero. A standard 4-sample technique was applied with samples collected at 180, 200, 220 and 240 min, if the estimated GFR (eGFR) was ≥30 mL/min. A comparison of single-sample GFR based on the 200 min sample was also conducted. Fifty-six patients were enrolled in the study. All patients had an estimated GFR >30 mL/min/1.73 m2. No patients suffered from ascites or significant oedema. The mean 51Cr-EDTA plasma clearance was 82 mL/min (range 16-226). The plasma clearances determined by the two methods were highly correlated (r = 0.993). The plasma clearance was significantly higher when measured by 99mTc-DTPA than by 51Cr-EDTA (p = 0.01), but the numerical difference was minimal (mean difference 1.4 mL/min; 95% limits of agreement (LOA) -6.6 to 9.4). The difference between the two methods was independent of the level of renal function. Similar results were found for one-sample GFR. No clinically relevant differences were found between the plasma clearance of 99mTc-DTPA and that of 51Cr-EDTA. Therefore, 99mTc-DTPA can replace 51Cr-EDTA when needed.


Assuntos
Radioisótopos de Cromo/sangue , Ácido Edético/sangue , Renografia por Radioisótopo/métodos , Compostos Radiofarmacêuticos/sangue , Pentetato de Tecnécio Tc 99m/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Radioisótopos de Cromo/farmacocinética , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Renografia por Radioisótopo/normas , Compostos Radiofarmacêuticos/farmacocinética , Pentetato de Tecnécio Tc 99m/farmacocinética , Adulto Jovem
11.
Scand J Clin Lab Invest ; 79(3): 194-201, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30784338

RESUMO

The interaction between hemodynamics and kidney function in heart failure (HF) is incompletely understood. We investigated the association between invasive hemodynamic parameters and measured glomerular filtration rate (mGFR) by plasma clearance of 51-chromium-labeled ethylenediamine tetra-acetic acid (51Cr-EDTA) in patients with advanced HF and tested the hypothesis that patients with reduced mGFR have lower cardiac index (CI) and mean arterial pressure (MAP) as well as higher central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP). We retrospectively studied 242 patients (mean age 50 ± 13 years) referred for evaluation for heart transplantation or implantation of a left ventricular assist device with a left ventricular ejection fraction < 45% on optimal medical therapy, who underwent right heart catheterization (RHC) and measurement of 51Cr-EDTA clearance. Mean mGFR was 63 ± 21 mL/min/1.73 m2, CI was 2.3 ± 0.7 L/min/m2, PCWP was 21 ± 9 mmHg, and CVP was 10.3 ± 5.2 mmHg. Univariate analysis demonstrated a significant correlation between mGFR and CI (r2 = 0.030, p = .007) and CVP (r2 = 0.017, p = .049) but not between mGFR and MAP or PCWP. In multivariate analyses, none of the hemodynamic variables remained significantly associated with mGFR. While CVP and CI were correlated with mGFR in univariate analysis the results of analyses adjusted for multiple covariates suggest that hemodynamics are only correlated to renal function in advanced HF to a modest degree challenging the hypothesis that renal dysfunction in HF mainly is a consequence of renal congestion.


Assuntos
Radioisótopos de Cromo/química , Ácido Edético/química , Taxa de Filtração Glomerular/fisiologia , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica/fisiologia , Adulto , Nitrogênio da Ureia Sanguínea , Creatinina/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
12.
BMC Nephrol ; 19(1): 383, 2018 12 29.
Artigo em Inglês | MEDLINE | ID: mdl-30594245

RESUMO

BACKGROUND: Most studies on obesity surgery have measured renal function using the estimated GFR. However, due to the reduction of muscle mass, and therefore creatinine that accompanies weight loss, such measures can falsely suggest an improvement in renal function. To balance the risks of surgery versus any potential benefits on renal function, we need to be able to determine renal function using valid and reliable methodologies. In this pilot study we aimed to measure renal function in patients with CKD undergoing obesity surgery using the gold standard 51Cr-EDTA GFR clearance methodology which is independent of measures of muscle mass. METHODS: Nine consecutive obese patients with CKD underwent obesity surgery. Their renal function was assessed using 51Cr-EDTA GFR, cystatin C and serum creatinine as well as using eGFR equations including MDRD CKD Epi, Cockcroft Gault and CKD Epi cystatin before and 12 months after surgery. RESULTS: Renal function using the 51Cr-EDTA measured GFR did not change significantly after surgery. Similar results were obtained when Cystatin C, CKD Epi cystatin, CKD Epi cystatin creatinine and adjusted Cockcroft Gault Creatinine clearance methods were used. In contrast there were either trends or significant improvements in renal function measured using the MDRD and CKD Epi equations. CONCLUSIONS: In this pilot study using the gold standard 51Cr-EDTA method we found stabilisation in renal function after obesity surgery. Until further definitive data emerge it is critical to balance the risk and benefits of surgery, especially if renal function may not improve as often as previously suggested. TRIAL REGISTRATION: ClinicalTrials.gov NCT01507350 . Registered June 2011.


Assuntos
Taxa de Filtração Glomerular , Obesidade/cirurgia , Insuficiência Renal Crônica/fisiopatologia , Cirurgia Bariátrica , Radioisótopos de Cromo , Creatinina/sangue , Cistatina C/sangue , Ácido Edético , Feminino , Humanos , Testes de Função Renal/métodos , Masculino , Conceitos Matemáticos , Pessoa de Meia-Idade , Obesidade/complicações , Projetos Piloto , Período Pós-Operatório , Período Pré-Operatório , Insuficiência Renal Crônica/complicações
13.
Immunology ; 150(4): 489-494, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28004383

RESUMO

Reliable measurement of cellular cytotoxicity is essential for the characterization of immune responses and for the monitoring of antibody treatment efficacy. Until now, the standard 51 Cr-release assay has remained the sole sensitive assay that measures cellular cytotoxicity. Alternative non-radioactive assays have been developed but they do not provide accurate measurement of target cell cytotoxicity. The cost and hazard of handling radioactivity are strong incentives to find alternative solutions to 51 Cr. We took advantage of the recent development of cell-imaging multimode readers to develop a novel non-radioactive and real-time cytotoxic assay that demonstrates good reproducibility and sensitivity. The extent of target-cell cytotoxicity is monitored over time by imaging and quantifying live fluorescent target cells in 96-well plates. We have developed classical natural killer cell assays in the presence or absence of blocking antibodies and antibody-dependent cell-mediated cytotoxicity. We show that in these assays, cell killing occurs within the first 2 hr with half maximum killing reached after 30 min. This technology has numerous applications such as natural killer and T-cell cytotoxicity assays and can be extended to cell survival and apoptosis measurement assays.


Assuntos
Testes Imunológicos de Citotoxicidade/métodos , Células Matadoras Naturais/imunologia , Linfócitos T Citotóxicos/imunologia , Separação Celular , Células Cultivadas , Radioisótopos de Cromo , Citotoxicidade Imunológica , Citometria de Fluxo , Corantes Fluorescentes , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Mol Pharm ; 14(12): 4243-4251, 2017 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-28737406

RESUMO

There is a renewed interest from the pharmaceutical field to develop oral formulations of compounds, such as peptides, oligonucleotides, and polar drugs. However, these often suffer from insufficient absorption across the intestinal mucosal barrier. One approach to circumvent this problem is the use of absorption modifying excipient(s) (AME). This study determined the absorption enhancing effect of four AMEs (sodium dodecyl sulfate, caprate, chitosan, N-acetylcysteine) on five model compounds in a rat jejunal perfusion model. The aim was to correlate the model compound absorption to the blood-to-lumen clearance of the mucosal marker for barrier integrity, 51Cr-EDTA. Sodium dodecyl sulfate and chitosan increased the absorption of the low permeation compounds but had no effect on the high permeation compound, ketoprofen. Caprate and N-acetylcysteine did not affect the absorption of any of the model compounds. The increase in absorption of the model compounds was highly correlated to an increased blood-to-lumen clearance of 51Cr-EDTA, independent of the AME. Thus, 51Cr-EDTA could be used as a general, sensitive, and validated marker molecule for absorption enhancement when developing novel formulations.


Assuntos
Radioisótopos de Cromo/farmacocinética , Ácido Edético/farmacocinética , Excipientes/farmacologia , Absorção Intestinal/efeitos dos fármacos , Mucosa Intestinal/efeitos dos fármacos , Animais , Disponibilidade Biológica , Biofarmácia/métodos , Radioisótopos de Cromo/química , Composição de Medicamentos/métodos , Ácido Edético/química , Mucosa Intestinal/metabolismo , Masculino , Modelos Animais , Perfusão , Permeabilidade/efeitos dos fármacos , Ratos , Ratos Wistar , Dodecilsulfato de Sódio
15.
BMC Nephrol ; 18(1): 52, 2017 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-28166744

RESUMO

BACKGROUND: When patients experience large weight loss, muscle mass may be affected followed by changes in plasma creatinine (pCr). The MDRD and CKD-EPI equations for estimated GFR (eGFR) include pCr. We hypothesised that a large weight loss reduces muscle mass and pCr causing increase in eGFR (creatinine-based equations), whereas measured GFR (mGFR) and cystatin C-based eGFR would be unaffected if adjusted for body surface area. METHODS: Prospective, intervention study including 19 patients. All attended a baseline visit before gastric bypass surgery followed by a visit six months post-surgery. mGFR was assessed during four hours plasma 51Cr-EDTA clearance. GFR was estimated by four equations (MDRD, CKD-EPI-pCr, CKD-EPI-cysC and CKD-EPI-pCr-cysC). DXA-scans were performed at baseline and six months post-surgery to measure changes in lean limb mass, as a surrogate for muscle mass. RESULTS: Patients were (mean ± SD) 40.0 ± 9.3 years, 14 (74%) were female and 5 (26%) had type 2 diabetes, baseline weight was 128 ± 19 kg, body mass index 41 ± 6 kg/m2 and absolute mGFR 122 ± 24 ml/min. Six months post-surgery weight loss was 27 (95% CI: 23; 30) kg, mGFR decreased by 9 (-17; -2) from 122 ± 24 to 113 ± 21 ml/min (p = 0.024), but corrected for current body surface area (BSA) mGFR was unchanged by 2 (-5; 9) ml/min/1.73 m2 (p = 0.52). CKD-EPI-pCr increased by 12 (6; 17) and MDRD by 13 (8; 18) (p < 0.001 for both), while CKD-EPI-cysC was unchanged by 2 (-8; 4) ml/min/1.73 m2 (p = 0.51). Lean limb mass was reduced by 3.5 (-4.4;-2.6; p < 0.001) kg and change in lean limb mass correlated with change in plasma creatinine (R 2 = 0.28, p = 0.032). CONCLUSIONS: Major weight reductions are associated with a reduction in absolute mGFR, which may reflect resolution of glomerular hyperfiltration, while mGFR adjusted for body surface area was unchanged. Estimates of GFR based on creatinine overestimate renal function likely due to changes in muscle mass, whereas cystatin C based estimates are unaffected. TRIAL REGISTRATION: ClinicalTrials.gov, NCT02138565 . Date of registration: March 24, 2014.


Assuntos
Composição Corporal , Creatinina/metabolismo , Cistatina C/metabolismo , Derivação Gástrica , Taxa de Filtração Glomerular , Músculo Esquelético/metabolismo , Obesidade Mórbida/cirurgia , Redução de Peso , Absorciometria de Fóton , Adulto , Superfície Corporal , Radioisótopos de Cromo , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/metabolismo , Ácido Edético , Feminino , Humanos , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/diagnóstico por imagem , Obesidade Mórbida/complicações , Obesidade Mórbida/metabolismo , Estudos Prospectivos
16.
Vox Sang ; 111(1): 62-70, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27007858

RESUMO

OBJECTIVES: Three leucoreduction filters were evaluated - when used alone or combined with centrifuge leucoreduction (C-LR) - to prevent alloimmune platelet refractoriness in a dog platelet transfusion model. MATERIALS AND METHODS: Donor platelet-rich plasma (PRP) or buffy coat (BC) platelets were either filter leucoreduced (F-LR) or F-LR/C-LR, (51) Cr radiolabelled and transfused. Weekly transfusions were given for up to 8 weeks or until platelet refractoriness. Recipients who accepted treated transfusions were then given non-leucoreduced (non-LR) platelets to determine whether donor-specific tolerance had been induced. RESULTS: Acceptance of F-LR PRP transfusions ranged from 29% to 66%. F-LR/C-LR transfusions prepared from PRP were accepted by 92%, from BC by 63% and from pooled PRP by 75% of recipients (p=NS); overall acceptance rate of F-LR/C-LR transfusions was 83%. Tolerance to subsequent non-LR transfusions occurred in 45% of the F-LR-/C-LR-accepting recipients unrelated to DR-B compatibility between donors and recipients (P = 0·18). CONCLUSION: In a dog platelet transfusion model, acceptance of donor platelets required combining F-LR with C-LR as apparently each process removes different immunizing WBCs.


Assuntos
Centrifugação , Filtração , Leucócitos/citologia , Transfusão de Plaquetas , Animais , Anticorpos/análise , Anticorpos/imunologia , Radioisótopos de Cromo/química , Radioisótopos de Cromo/metabolismo , Cães , Feminino , Citometria de Fluxo , Teste de Histocompatibilidade , Contagem de Leucócitos , Leucócitos/imunologia , Modelos Animais , Plasma Rico em Plaquetas/citologia , Trombocitopenia
17.
Transfusion ; 55(3): 491-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25233911

RESUMO

BACKGROUND: Transfusion of long-stored red blood cells (RBCs) is associated with decreased in vivo RBC recovery, delivery of RBC breakdown products, and increased morbidity and mortality. Reducing the burden of this RBC "storage lesion" is a major challenge in transfusion medicine. Additive solution-7 (AS-7) is a new RBC storage solution designed to improve RBC metabolism by providing phosphate and increasing buffering capacity. STUDY DESIGN AND METHODS: Storage quality in AS-7 was measured in a prospective, randomized, three-center trial using units of whole blood from healthy human subjects whose RBCs were stored for up to 56 days in AS-7 (n = 120) or for 42 days in the control solution AS-1 (n = 60). RESULTS: Hemolysis and shedding of protein-containing microvesicles were significantly reduced in RBCs stored in AS-7 for 42 and 56 days compared with RBCs stored in AS-1. Autologous in vivo recoveries of RBCs stored in AS-7 was 88 ± 5% at 42 days (n = 27) and 82 ± 3% at 56 days (n = 27), exceeding recoveries of RBCs stored in currently used solutions. CONCLUSION: Increasing the phosphate, pH range, and buffer capacity of a RBC storage system allowed RBCs to be stored better and longer than currently approved storage systems. AS-7 ameliorates the long-term storage lesion resulting in significantly increased viability in vitro and in vivo.


Assuntos
Preservação de Sangue/métodos , Temperatura Baixa/efeitos adversos , Crioprotetores/farmacologia , Eritrócitos/efeitos dos fármacos , Soluções Farmacêuticas/farmacologia , Adenina/farmacologia , Anticoagulantes/farmacologia , Soluções Tampão , Sobrevivência Celular/efeitos dos fármacos , Radioisótopos de Cromo/sangue , Citratos/farmacologia , Eritrócitos/citologia , Eritrócitos/metabolismo , Glucose/farmacologia , Hemólise/efeitos dos fármacos , Humanos , Concentração de Íons de Hidrogênio , Técnicas In Vitro , Procedimentos de Redução de Leucócitos/instrumentação , Manitol/farmacologia , Estudos Prospectivos , Cloreto de Sódio/farmacologia , Fatores de Tempo
18.
Scand J Clin Lab Invest ; 75(1): 64-72, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25410087

RESUMO

BACKGROUND AND AIM: In patients with fluid retention, the total plasma clearance of (51)Cr-EDTA (ClP) may overestimate the glomerular filtration rate (GFR). The present study was therefore undertaken in order to compare ClP with the urinary plasma clearance of (51)Cr-EDTA (ClU) in patients with cirrhosis with and without fluid retention. MATERIAL AND METHODS: A total of 136 patients with cirrhosis (24 without fluid retention, 112 with ascites) received a quantitative intravenous injection of (51)Cr-EDTA followed by plasma and quantitative urinary samples for 5 hours. ClP was determined from the injected dose relative to the plasma concentration-time area, extrapolated to infinity. ClU was determined as urinary excretion relative to the plasma concentration-time area up to voiding. RESULTS: In patients without fluid retention, the difference between ClP and ClU (ClP - ClU = ClΔ) was mean 4.5 mL/min/1.73 m(2). In patients with ascites, ClΔ was significantly higher (17.6 mL/min/1.73 m(2), p < 0.0001). ClΔ increased with lower values of GFR (r = - 0.458, p < 0.001). Repeated measurements of ClU in a subgroup of patients with fluid retention (n = 25) gave almost identical values. Different types of corrections of one-pool clearance were almost identical with ClP, except for higher clearance values, which were somewhat underestimated by the former. CONCLUSION: In patients with fluid retention and ascites ClP and corrected one-pool clearance overestimates GFR substantially. Although ClU may underestimate GFR slightly, patients with ascites should collect urine quantitatively in order to obtain a reliable measurement of GFR.


Assuntos
Radioisótopos de Cromo/farmacocinética , Ácido Edético/farmacocinética , Fibrose/urina , Adulto , Idoso , Feminino , Fibrose/diagnóstico por imagem , Fibrose/fisiopatologia , Taxa de Filtração Glomerular , Humanos , Masculino , Taxa de Depuração Metabólica , Pessoa de Meia-Idade , Cintilografia
19.
Diabet Med ; 31(5): 559-63, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24236770

RESUMO

OBJECTIVE: In animal models of obesity and Type 2 diabetes, permeability of the intestine is increased because of impairment of tight junction proteins, allowing translocation of bacterial endotoxin and resulting in low-grade systemic inflammation. This has yet to be demonstrated in humans. The objective of this study was the demonstration of increased intestinal permeability in human Type 2 diabetes. METHODS: We examined intestinal permeability using chromium ((51) Cr)-EDTA urinary recovery in twenty well-controlled men with Type 2 diabetes compared with control subjects matched for age, gender and BMI. RESULTS: Intestinal permeability was significantly increased (P = 0.002) in the diabetic group and was correlated to increased levels of systemic inflammatory markers high-sensitivity C-reactive protein (r = 0.694, P = 0.001), interleukin 6 (r = 0.548, P = 0.012) and tumour necrosis factor alpha (r = 0.564, P = 0.010). CONCLUSION: This is the first demonstration that increased intestinal permeability may be a feature of human Type 2 diabetes.


Assuntos
Permeabilidade da Membrana Celular/fisiologia , Diabetes Mellitus Tipo 2/urina , Ácido Edético/urina , Absorção Intestinal/fisiologia , Mucosa Intestinal/metabolismo , Administração Oral , Biomarcadores/metabolismo , Proteína C-Reativa/metabolismo , Estudos de Casos e Controles , Radioisótopos de Cromo/administração & dosagem , Radioisótopos de Cromo/urina , Diabetes Mellitus Tipo 2/sangue , Ácido Edético/administração & dosagem , Humanos , Interleucina-6/sangue , Intestinos/citologia , Masculino , Pessoa de Meia-Idade , Fator de Necrose Tumoral alfa/sangue
20.
Clin Chem Lab Med ; 52(12): 1747-54, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24940711

RESUMO

BACKGROUND: The Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation seems to correct the overdiagnosis of chronic kidney disease (CKD) provided by Modification of Diet in Renal Disease (MDRD) equation. However, this point has not been tested in some ethnic groups. This study investigated the performance of MDRD and CKD-EPI equations in South Brazilian individuals. METHODS: This cross-sectional study included 354 individuals including healthy volunteers, diabetic and non-diabetic individuals with or without CKD. Glomerular filtration rate (GFR) was measured by the 51Cr-EDTA single-injection method (51Cr-GFR). Accuracy (P30), bias, and Bland-Altman agreement plots were evaluated. RESULTS: In the group as a whole, 51Cr-GFR was 87±37 (6-187), CKD-EPI eGFR, 82±30 (6-152), and MDRD eGFR, 77±28 (6-156) mL/min/1.73 m2 (p<0.001 for all comparisons). Analyzing the subset of individuals with 51Cr-GFR <60 mL/min/1.73 m2, P30 values were, respectively, 76% and 84% for MDRD and for CKD-EPI (p<0.001) while for 51Cr-GFR ≥60 mL/min/1.73 m2, P30 values were 57.5% for both equations (p=1.000). For MDRD and CKD-EPI, mean bias were negative for GFRs <60 (-11 vs. -12, p=0.221) and positive for values >60 (16 vs. 9, p<0.001). In multivariate analysis, absolute bias was unfavorably influenced by measured GFR >60 (for MDRD) and being diabetic or younger (for CKD-EPI). CONCLUSIONS: CKD-EPI reduces GFR underestimation in individuals with GFRs >60, but still presents a quite low accuracy at this GFR range. Moreover, it tends to overestimate GFR in subjects with GFRs <60 mL/min/1.73 m2. CKD stages 1 and 2, diabetes and young age had a negative influence on the performance of the equations.


Assuntos
Algoritmos , Taxa de Filtração Glomerular/fisiologia , Insuficiência Renal Crônica/fisiopatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Brasil , Radioisótopos de Cromo/química , Creatinina/sangue , Estudos Transversais , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Índice de Gravidade de Doença , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA