Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 794
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 91(2): 600-614, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37849064

RESUMO

PURPOSE: To develop a novel deep learning approach for 4D-MRI reconstruction, named Movienet, which exploits space-time-coil correlations and motion preservation instead of k-space data consistency, to accelerate the acquisition of golden-angle radial data and enable subsecond reconstruction times in dynamic MRI. METHODS: Movienet uses a U-net architecture with modified residual learning blocks that operate entirely in the image domain to remove aliasing artifacts and reconstruct an unaliased motion-resolved 4D image. Motion preservation is enforced by sorting the input image and reference for training in a linear motion order from expiration to inspiration. The input image was collected with a lower scan time than the reference XD-GRASP image used for training. Movienet is demonstrated for motion-resolved 4D MRI and motion-resistant 3D MRI of abdominal tumors on a therapeutic 1.5T MR-Linac (1.5-fold acquisition acceleration) and diagnostic 3T MRI scanners (2-fold and 2.25-fold acquisition acceleration for 4D and 3D, respectively). Image quality was evaluated quantitatively and qualitatively by expert clinical readers. RESULTS: The reconstruction time of Movienet was 0.69 s (4 motion states) and 0.75 s (10 motion states), which is substantially lower than iterative XD-GRASP and unrolled reconstruction networks. Movienet enables faster acquisition than XD-GRASP with similar overall image quality and improved suppression of streaking artifacts. CONCLUSION: Movienet accelerates data acquisition with respect to compressed sensing and reconstructs 4D images in less than 1 s, which would enable an efficient implementation of 4D MRI in a clinical setting for fast motion-resistant 3D anatomical imaging or motion-resolved 4D imaging.


Assuntos
Imageamento por Ressonância Magnética , Técnicas de Imagem de Sincronização Respiratória , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Movimento (Física) , Aceleração , Técnicas de Imagem de Sincronização Respiratória/métodos , Processamento de Imagem Assistida por Computador/métodos , Respiração
2.
NMR Biomed ; 37(8): e5134, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38459747

RESUMO

Free-breathing abdominal chemical exchange saturation transfer (CEST) has great potential for clinical application, but its technical implementation remains challenging. This study aimed to propose and evaluate a free-breathing abdominal CEST sequence. The proposed sequence employed respiratory gating (ResGat) to synchronize the data acquisition with respiratory motion and performed a water presaturation module before the CEST saturation to abolish the influence of respiration-induced repetition time variation. In vivo experiments were performed to compare different respiratory motion-control strategies and B0 offset correction methods, and to evaluate the effectiveness and necessity of the quasi-steady-state (QUASS) approach for correcting the influence of the water presaturation module on CEST signal. ResGat with a target expiratory phase of 0.5 resulted in a higher structural similarity index and a lower coefficient of variation on consecutively acquired CEST S0 images than breath-holding (BH) and respiratory triggering (all p < 0.05). B0 maps derived from the abdominal CEST dataset itself were more stable for B0 correction, compared with the separately acquired B0 maps by a dual-echo time scan and B0 maps derived from the water saturation shift referencing approach. Compared with BH, ResGat yielded more homogeneous magnetization transfer ratio asymmetry maps at 3.5 ppm (standard deviation: 3.96% vs. 3.19%, p = 0.036) and a lower mean squared difference between scan and rescan (27.52‱ vs. 16.82‱, p = 0.004). The QUASS approach could correct the water presaturation-induced CEST signal change, but its necessity for in vivo scanning needs further verification. The proposed free-breathing abdominal CEST sequence using ResGat had an acquisition efficiency of approximately four times that using BH. In conclusion, the proposed free-breathing abdominal CEST sequence using ResGat and water presaturation has a higher acquisition efficiency and image quality than abdominal CEST using BH.


Assuntos
Abdome , Imageamento por Ressonância Magnética , Respiração , Técnicas de Imagem de Sincronização Respiratória , Água , Abdome/diagnóstico por imagem , Humanos , Água/química , Técnicas de Imagem de Sincronização Respiratória/métodos , Masculino , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino
3.
NMR Biomed ; 37(10): e5180, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38775032

RESUMO

Ultrahigh field magnetic resonance imaging (MRI) (≥ 7 T) has the potential to provide superior spatial resolution and unique image contrast. Apart from radiofrequency transmit inhomogeneities in the body at this field strength, imaging of the upper abdomen faces additional challenges associated with motion-induced ghosting artifacts. To address these challenges, the goal of this work was to develop a technique for high-resolution free-breathing upper abdominal MRI at 7 T with a large field of view. Free-breathing 3D gradient-recalled echo (GRE) water-excited radial stack-of-stars data were acquired in seven healthy volunteers (five males/two females, body mass index: 19.6-24.8 kg/m2) at 7 T using an eight-channel transceive array coil. Two volunteers were also examined at 3 T. In each volunteer, the liver and kidney regions were scanned in two separate acquisitions. To homogenize signal excitation, the time-interleaved acquisition of modes (TIAMO) method was used with personalized pairs of B1 shims, based on a 23-s Cartesian fast low angle shot (FLASH) acquisition. Utilizing free-induction decay navigator signals, respiratory-gated images were reconstructed at a spatial resolution of 0.8 × 0.8 × 1.0 mm3. Two experienced radiologists rated the image quality and the impact of B1 inhomogeneity and motion-related artifacts on multipoint scales. The images of all volunteers showcased effective water excitation and were accurately corrected for respiratory motion. The impact of B1 inhomogeneity on image quality was minimal, underscoring the efficacy of the multitransmit TIAMO shim. The high spatial resolution allowed excellent depiction of small structures such as the adrenal glands, the proximal ureter, the diaphragm, and small blood vessels, although some streaking artifacts persisted in liver image data. In direct comparisons with 3 T performed for two volunteers, 7-T acquisitions demonstrated increases in signal-to-noise ratio of 77% and 58%. Overall, this work demonstrates the feasibility of free-breathing MRI in the upper abdomen at submillimeter spatial resolution at a magnetic field strength of 7 T.


Assuntos
Abdome , Imageamento por Ressonância Magnética , Respiração , Humanos , Feminino , Masculino , Abdome/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Técnicas de Imagem de Sincronização Respiratória/métodos , Artefatos
4.
J Cardiovasc Magn Reson ; 26(1): 101037, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38499269

RESUMO

BACKGROUND: Free-running cardiac and respiratory motion-resolved whole-heart five-dimensional (5D) cardiovascular magnetic resonance (CMR) can reduce scan planning and provide a means of evaluating respiratory-driven changes in clinical parameters of interest. However, respiratory-resolved imaging can be limited by user-defined parameters which create trade-offs between residual artifact and motion blur. In this work, we develop and validate strategies for both correction of intra-bin and compensation of inter-bin respiratory motion to improve the quality of 5D CMR. METHODS: Each component of the reconstruction framework was systematically validated and compared to the previously established 5D approach using simulated free-running data (N = 50) and a cohort of 32 patients with congenital heart disease. The impact of intra-bin respiratory motion correction was evaluated in terms of image sharpness while inter-bin respiratory motion compensation was evaluated in terms of reconstruction error, compression of respiratory motion, and image sharpness. The full reconstruction framework (intra-acquisition correction and inter-acquisition compensation of respiratory motion [IIMC] 5D) was evaluated in terms of image sharpness and scoring of image quality by expert reviewers. RESULTS: Intra-bin motion correction provides significantly (p < 0.001) sharper images for both simulated and patient data. Inter-bin motion compensation results in significant (p < 0.001) lower reconstruction error, lower motion compression, and higher sharpness in both simulated (10/11) and patient (9/11) data. The combined framework resulted in significantly (p < 0.001) sharper IIMC 5D reconstructions (End-expiration (End-Exp): 0.45 ± 0.09, End-inspiration (End-Ins): 0.46 ± 0.10) relative to the previously established 5D implementation (End-Exp: 0.43 ± 0.08, End-Ins: 0.39 ± 0.09). Similarly, image scoring by three expert reviewers was significantly (p < 0.001) higher using IIMC 5D (End-Exp: 3.39 ± 0.44, End-Ins: 3.32 ± 0.45) relative to 5D images (End-Exp: 3.02 ± 0.54, End-Ins: 2.45 ± 0.52). CONCLUSION: The proposed IIMC reconstruction significantly improves the quality of 5D whole-heart MRI. This may be exploited for higher resolution or abbreviated scanning. Further investigation of the diagnostic impact of this framework and comparison to gold standards is needed to understand its full clinical utility, including exploration of respiratory-driven changes in physiological measurements of interest.


Assuntos
Artefatos , Cardiopatias Congênitas , Interpretação de Imagem Assistida por Computador , Valor Preditivo dos Testes , Humanos , Reprodutibilidade dos Testes , Feminino , Masculino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Adulto , Adulto Jovem , Imageamento por Ressonância Magnética , Adolescente , Mecânica Respiratória , Técnicas de Imagem de Sincronização Respiratória , Criança , Pessoa de Meia-Idade , Respiração , Imagem Cinética por Ressonância Magnética
5.
J Cardiovasc Magn Reson ; 26(1): 100992, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38211655

RESUMO

BACKGROUND: The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA). METHODS: Patients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained. RESULTS: Mean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR). CONCLUSION: Mapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases.


Assuntos
Aorta Torácica , Doenças da Aorta , Meios de Contraste , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Variações Dependentes do Observador , Valor Preditivo dos Testes , Humanos , Reprodutibilidade dos Testes , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Aorta Torácica/diagnóstico por imagem , Idoso , Meios de Contraste/administração & dosagem , Doenças da Aorta/diagnóstico por imagem , Técnicas de Imagem de Sincronização Respiratória , Adulto , Fatores de Tempo , Interpretação de Imagem Assistida por Computador , Técnicas de Imagem de Sincronização Cardíaca
6.
Radiographics ; 44(8): e230173, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38990776

RESUMO

T1-weighted (T1W) pulse sequences are an indispensable component of clinical protocols in abdominal MRI but usually require multiple breath holds (BHs) during the examination, which not all patients can sustain. Patient motion can affect the quality of T1W imaging so that key diagnostic information, such as intrinsic signal intensity and contrast enhancement image patterns, cannot be determined. Patient motion also has a negative impact on examination efficiency, as multiple acquisition attempts prolong the duration of the examination and often remain noncontributory. Techniques for mitigation of motion-related artifacts at T1W imaging include multiple arterial acquisitions within one BH; free breathing with respiratory gating or respiratory triggering; and radial imaging acquisition techniques, such as golden-angle radial k-space acquisition (stack-of-stars). While each of these techniques has inherent strengths and limitations, the selection of a specific motion-mitigation technique is based on several factors, including the clinical task under investigation, downstream technical ramifications, patient condition, and user preference. The authors review the technical principles of free-breathing motion mitigation techniques in abdominal MRI with T1W sequences, offer an overview of the established clinical applications, and outline the existing limitations of these techniques. In addition, practical guidance for abdominal MRI protocol strategies commonly encountered in clinical scenarios involving patients with limited BH abilities is rendered. Future prospects of free-breathing T1W imaging in abdominal MRI are also discussed. ©RSNA, 2024 See the invited commentary by Fraum and An in this issue.


Assuntos
Abdome , Artefatos , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Abdome/diagnóstico por imagem , Movimento (Física) , Aumento da Imagem/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos
7.
MAGMA ; 37(5): 873-886, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38400926

RESUMO

OBJECTIVES: To evaluate a new motion correction method, named RT + NV Track, for upper abdominal DWI that combines the respiratory triggering (RT) method using a respiration sensor and the Navigator Track (NV Track) method using navigator echoes. MATERIALS AND METHODS: To evaluate image quality acquired upper abdominal DWI and ADC images with RT, NV, and RT + NV Track in 10 healthy volunteers and 35 patients, signal-to-noise efficiency (SNRefficiency) and the coefficient of variation (CV) of ADC values were measured. Five radiologists independently performed qualitative image-analysis assessments. RESULTS: RT + NV Track showed significantly higher SNRefficiency than RT and NV (14.01 ± 4.86 vs 12.05 ± 4.65, 10.05 ± 3.18; p < 0.001, p < 0.001). RT + NV Track was superior to RT and equal or better quality than NV in CV and visual evaluation of ADC values (0.033 ± 0.018 vs 0.080 ± 0.042, 0.057 ± 0.034; p < 0.001, p < 0.001). RT + NV Track tends to acquire only expiratory data rather than NV, even in patients with relatively rapid breathing, and can correct for respiratory depth variations, a weakness of RT, thus minimizing image quality degradation. CONCLUSION: The RT + NV Track method is an efficient imaging method that combines the advantages of both RT and NV methods in upper abdominal DWI, providing stably good images in a short scan time.


Assuntos
Abdome , Imagem de Difusão por Ressonância Magnética , Respiração , Razão Sinal-Ruído , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Masculino , Feminino , Adulto , Abdome/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Voluntários Saudáveis , Movimento (Física) , Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Adulto Jovem , Algoritmos , Técnicas de Imagem de Sincronização Respiratória/métodos
8.
J Appl Clin Med Phys ; 25(10): e14491, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39194180

RESUMO

PURPOSE: To investigate a novel bioimpedance-based respiratory gating system (BRGS) designed for external beam radiotherapy and to evaluate its technical characteristics in comparison with existing similar systems. MATERIALS AND METHODS: The BRGS was tested on three healthy volunteers in free breathing and breath-hold patterns under laboratory conditions. Its parameters, including the time delay (TD) between the actual impedance change and the gating signal, temperature drift, root mean square (RMS) noise, and signal-to-noise ratio (SNR), were measured and analyzed. RESULTS: The gate-on TD and the gate-off TD were found to be 9.0 ± 2.0 ms [mean ± standard deviation (M ± SD)] and 7.2 ± 1.3 ms, respectively. The temperature drift of the BRGS output signal was 0.02 Ω after 30 min of operation. RMS noise averaged 0.14 ± 0.05 Ω (M ± SD) for all subjects and varied from 0.08 to 0.20 Ω with repeated measurements. A significant difference in SNR (p < 0.001) was observed between subjects, ranging from 4 to 15. CONCLUSION: The evaluated bioimpedance-based gating system showed a high performance in real-time respiratory monitoring and may potentially be used as an external surrogate guidance for respiratory-gated external beam radiotherapy. Direct comparison with commercially available systems, 4D correlation studies, and expansion of the patient sample are goals for future preclinical studies.


Assuntos
Impedância Elétrica , Planejamento da Radioterapia Assistida por Computador , Razão Sinal-Ruído , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Voluntários Saudáveis , Respiração , Masculino , Neoplasias/radioterapia , Feminino , Adulto , Técnicas de Imagem de Sincronização Respiratória/métodos , Suspensão da Respiração , Radioterapia de Intensidade Modulada/métodos
9.
J Appl Clin Med Phys ; 25(5): e14349, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38551392

RESUMO

PURPOSE: Beam delivery latency in respiratory-gated particle therapy systems is a crucial issue to dose delivery accuracy. The aim of this study is to develop a multi-channel signal acquisition platform for investigating gating latencies occurring within RPM respiratory gating system (Varian, USA) and ProBeam proton treatment system (Varian, USA) individually. METHODS: The multi-channel signal acquisition platform consisted of several electronic components, including a string position sensor for target motion detection, a photodiode for proton beam sensing, an interfacing board for accessing the trigger signal between the respiratory gating system and the proton treatment system, a signal acquisition device for sampling and synchronizing signals from the aforementioned components, and a laptop for controlling the signal acquisition device and data storage. RPM system latencies were determined by comparing the expected gating phases extracted from the motion signal with the trigger signal's state turning points. ProBeam system latencies were assessed by comparing the state turning points of the trigger signal with the beam signal. The total beam delivery latencies were calculated as the sum of delays in the respiratory gating system and the cyclotron proton treatment system. During latency measurements, simulated sinusoidal motion were applied at different amplitudes and periods for complete beam delivery latency evaluation under different breathing patterns. Each breathing pattern was repeated 30 times for statistical analysis. RESULTS: The measured gating ON/OFF latencies in the RPM system were found to be 104.20 ± 13.64 ms and 113.60 ± 14.98 ms, respectively. The measured gating ON/OFF delays in the ProBeam system were 108.29 ± 0.85 ms and 1.20 ± 0.04 ms, respectively. The total beam ON/OFF latencies were determined to be 212.50 ± 13.64 ms and 114.80 ± 14.98 ms. CONCLUSION: With the developed multi-channel signal acquisition platform, it was able to investigate the gating lags happened in both the respiratory gating system and the proton treatment system. The resolution of the platform is enough to distinguish the delays at the millisecond time level. Both the respiratory gating system and the proton treatment system made contributions to gating latency. Both systems contributed nearly equally to the total beam ON latency, with approximately 100 ms. In contrast, the respiratory gating system was the dominant contributor to the total beam OFF latency.


Assuntos
Terapia com Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Terapia com Prótons/métodos , Terapia com Prótons/instrumentação , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Respiração , Neoplasias/radioterapia , Imagens de Fantasmas , Técnicas de Imagem de Sincronização Respiratória/métodos , Órgãos em Risco/efeitos da radiação
10.
J Appl Clin Med Phys ; 25(8): e14376, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38695849

RESUMO

PURPOSE: To propose a straightforward and time-efficient quality assurance (QA) approach of beam time delay for respiratory-gated radiotherapy and validate the proposed method on typical respiratory gating systems, Catalyst™ and AlignRT™. METHODS: The QA apparatus was composed of a motion platform and a Winston-Lutz cube phantom (WL3) embedded with metal balls. The apparatus was first scanned in CT-Sim and two types of QA plans specific for beam on and beam off time delay, respectively, were designed. Static reference images and motion testing images of the WL3 cube were acquired with EPID. By comparing the position differences of the embedded metal balls in the motion and reference images, beam time delays were determined. The proposed approach was validated on three linacs with either Catalyst™ or AlignRT™ respiratory gating systems. To investigate the impact of energy and dose rate on beam time delay, a range of QA plans with Eclipse (V15.7) were devised with varying energy and dose rates. RESULTS: For all energies, the beam on time delays in AlignRT™ V6.3.226, AlignRT™ V7.1.1, and Catalyst™ were 92.13 ± $ \pm $ 5.79 ms, 123.11 ± $ \pm $ 6.44 ms, and 303.44 ± $ \pm $ 4.28 ms, respectively. The beam off time delays in AlignRT™ V6.3.226, AlignRT™ V7.1.1, and Catalyst™ were 121.87 ± $ \pm $ 1.34 ms, 119.33 ± $ \pm $ 0.75 ms, and 97.69 ± $ \pm $ 2.02 ms, respectively. Furthermore, the beam on delays decreased slightly as dose rates increased for all gating systems, whereas the beam off delays remained unaffected. CONCLUSIONS: The validation results demonstrate the proposed QA approach of beam time delay for respiratory-gated radiotherapy was both reproducible and time-efficient to practice for institutions to customize accordingly.


Assuntos
Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas , Aceleradores de Partículas/instrumentação , Respiração , Técnicas de Imagem de Sincronização Respiratória/métodos , Neoplasias/radioterapia , Fatores de Tempo
11.
J Appl Clin Med Phys ; 25(6): e14280, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38252745

RESUMO

PURPOSE: This study evaluated the intra- and inter-fractional variation of tumors with fiducial markers (FMs), relative to the tumor-FM distance, to establish how close an FM should be inserted for respiratory-gated stereotactic body radiation therapy (RG-SBRT). METHODS: Forty-five lung tumors treated with RG-SBRT were enrolled. End-expiratory computed tomography (CT) (CTplan) and four-dimensional-CT (4D-CT) scans were obtained for planning. End-expiratory CT (CTfr) scanning was performed before each fraction. The FMs were divided into two groups based on the median tumor-FM distance in the CTplan (Dp). For the intra-fractional variation, the correlations between the corresponding tumor and FM intra-fractional motions, defined as the centroid coordinates of those in each 0-90% phase, with the 50% phase of 4D-CT as the origin, were calculated in the left-right, anterior-posterior, and superior-inferior directions. Furthermore, the maximum difference in the tumor-FM distance in each phase of 4D-CT scan, based on those in the 50% phase of 4D-CT scan (Dmax), was obtained. Inter-fractional variation was defined as the maximum distance between the tumors in CTplan and CTfr, when the CT scans were fused based on each FM or vertebra. RESULTS: The median Dp was 26.1 mm. While FM intra-fractional motions were significantly and strongly correlated with the tumor intra-fractional motions in only anterior-posterior and superior-inferior directions for the Dp > 26 mm group, they were significantly and strongly correlated in all directions for the Dp ≤ 26 mm group. In all directions, Dmax values of the Dp ≤ 26 mm group were lower than those of the Dp > 26 mm group. The inter-fractional variations based on the Dp ≤ 26 mm were smaller than those on the Dp > 26 mm and on the vertebra in all directions. CONCLUSIONS: Regarding intra- and inter-fractional variation, FMs for Dp ≤ 26 mm can increase the accuracy for RG-SBRT.


Assuntos
Marcadores Fiduciais , Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Radiocirurgia/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada Quadridimensional/métodos , Masculino , Feminino , Radioterapia de Intensidade Modulada/métodos , Idoso , Respiração , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Movimento , Prognóstico , Técnicas de Imagem de Sincronização Respiratória/métodos , Órgãos em Risco/efeitos da radiação
12.
Eur Radiol ; 33(5): 3366-3376, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36565352

RESUMO

OBJECTIVES: This study aimed to investigate the performance of respiratory-gating imaging with reduced acquisition time using the total-body positron emission tomography/computed tomography (PET/CT) scanner. METHODS: Imaging data of 71 patients with suspect malignancies who underwent total-body 2-[18F]-fluoro-2-deoxy-D-glucose PET/CT for 15 min with respiration recorded were analyzed. For each examination, four reconstructions were performed: Ungated-15, using all coincidences; Ungated-5, using data of the first 5 min; Gated-15 using all coincidences but with respiratory gating; and Gated-6 using data of the first 6 min with respiratory gating. Lesions were quantified and image quality was evaluated; both were compared between the four image sets. RESULTS: A total of 390 lesions were found in the thorax and upper abdomen. Lesion detectability was significantly higher in gated-15 (97.2%) than in ungated-15 (93.6%, p = 0.001) and ungated-5 (92.3%, p = 0.001), but comparable to Gated-6 (95.9%, p = 0.993). A total of 131 lesions were selected for quantitative analyses. Lesions in Gated-15 presented significantly larger standardized uptake values, tumor-to-liver ratio, and tumor-to-blood ratio, but smaller metabolic tumor volume, compared to those in Ungated-15 and Ungated-5 (all p < 0.001). These differences were more obvious in small lesions and in lesions from sites other than mediastinum/retroperitoneum. However, these indices were not significantly different between Gated-15 and Gated-6. Higher, but acceptable, image noise was identified in gated images than in ungated images. CONCLUSIONS: Respiratory-gating imaging with reduced scanning time using the total-body PET/CT scanner is superior to ungated imaging and can be used in the clinic. KEY POINTS: • In PET imaging, respiratory gating can improve lesion presentation and detectability but requires longer imaging time. • This single-center study showed that the total-body PET scanner allows respiratory-gated imaging with reduced and clinically acceptable scanning time.


Assuntos
Neoplasias Hepáticas , Técnicas de Imagem de Sincronização Respiratória , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia Computadorizada por Raios X/métodos , Tomografia por Emissão de Pósitrons/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Desoxiglucose , Fluordesoxiglucose F18
13.
J Cardiovasc Magn Reson ; 24(1): 47, 2022 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-35948936

RESUMO

BACKGROUND: Exercise cardiovascular magnetic resonance (Ex-CMR) is a promising stress imaging test for coronary artery disease (CAD). However, Ex-CMR requires accelerated imaging techniques that result in significant aliasing artifacts. Our goal was to develop and evaluate a free-breathing and electrocardiogram (ECG)-free real-time cine with deep learning (DL)-based radial acceleration for Ex-CMR. METHODS: A 3D (2D + time) convolutional neural network was implemented to suppress artifacts from aliased radial cine images. The network was trained using synthetic real-time radial cine images simulated using breath-hold, ECG-gated segmented Cartesian k-space data acquired at 3 T from 503 patients at rest. A prototype real-time radial sequence with acceleration rate = 12 was used to collect images with inline DL reconstruction. Performance was evaluated in 8 healthy subjects in whom only rest images were collected. Subsequently, 14 subjects (6 healthy and 8 patients with suspected CAD) were prospectively recruited for an Ex-CMR to evaluate image quality. At rest (n = 22), standard breath-hold ECG-gated Cartesian segmented cine and free-breathing ECG-free real-time radial cine images were acquired. During post-exercise stress (n = 14), only real-time radial cine images were acquired. Three readers evaluated residual artifact level in all collected images on a 4-point Likert scale (1-non-diagnostic, 2-severe, 3-moderate, 4-minimal). RESULTS: The DL model substantially suppressed artifacts in real-time radial cine images acquired at rest and during post-exercise stress. In real-time images at rest, 89.4% of scores were moderate to minimal. The mean score was 3.3 ± 0.7, representing increased (P < 0.001) artifacts compared to standard cine (3.9 ± 0.3). In real-time images during post-exercise stress, 84.6% of scores were moderate to minimal, and the mean artifact level score was 3.1 ± 0.6. Comparison of left-ventricular (LV) measures derived from standard and real-time cine at rest showed differences in LV end-diastolic volume (3.0 mL [- 11.7, 17.8], P = 0.320) that were not significantly different from zero. Differences in measures of LV end-systolic volume (7.0 mL [- 1.3, 15.3], P < 0.001) and LV ejection fraction (- 5.0% [- 11.1, 1.0], P < 0.001) were significant. Total inline reconstruction time of real-time radial images was 16.6 ms per frame. CONCLUSIONS: Our proof-of-concept study demonstrated the feasibility of inline real-time cine with DL-based radial acceleration for Ex-CMR.


Assuntos
Doença da Artéria Coronariana , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Técnicas de Imagem de Sincronização Respiratória , Doença da Artéria Coronariana/diagnóstico por imagem , Aprendizado Profundo , Teste de Esforço , Estudos de Viabilidade , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Técnicas de Imagem de Sincronização Respiratória/métodos
14.
J Appl Clin Med Phys ; 23(5): e13619, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35481961

RESUMO

Data driven respiratory gating (DDG) in positron emission tomography (PET) imaging extracts respiratory waveforms from the acquired PET data obviating the need for dedicated external devices. DDG performance, however, degrades with decreasing detected number of coincidence counts. In this paper, we assess the clinical impact of reducing injected activity on a new DDG algorithm designed for PET data acquired with continuous bed motion (CBM_DDG) by evaluating CBM_DDG waveforms, tumor quantification, and physician's perception of motion blur in resultant images. Forty patients were imaged on a Siemens mCT scanner in CBM mode. Reduced injected activity was simulated by generating list mode datasets with 50% and 25% of the original data (100%). CBM_DDG waveforms were compared to that of the original data over the range between the aortic arch and the center of the right kidney using the Pearson correlation coefficient (PCC). Tumor quantification was assessed by comparing the maximum standardized uptake value (SUVmax) and peak SUV (SUVpeak) of reconstructed images from the various list mode datasets using elastic motion deblurring (EMDB) reconstruction. Perceived motion blur was assessed by three radiologists of one lesion per patient on a continuous scale from no motion blur (0) to significant motion blur (3). The mean PCC of the 50% and 25% dataset waveforms was 0.74 ± 0.18 and 0.59 ± 0.25, respectively. In comparison to the 100% datasets, the mean SUVmax increased by 2.25% (p = 0.11) for the 50% datasets and by 3.91% (p = 0.16) for the 25% datasets, while SUVpeak changes were within ±0.25%. Radiologist evaluations of motion blur showed negligible changes with average values of 0.21, 0.3, and 0.28 for the 100%, 50%, and 25% datasets. Decreased injected activities degrades the resultant CBM_DDG respiratory waveforms; however this decrease has minimal impact on quantification and perceived image motion blur.


Assuntos
Neoplasias , Técnicas de Imagem de Sincronização Respiratória , Humanos , Processamento de Imagem Assistida por Computador/métodos , Movimento (Física) , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos
15.
Magn Reson Med ; 85(5): 2672-2685, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33306216

RESUMO

PURPOSE: To describe an approach for detection of respiratory signals using a transmitted radiofrequency (RF) reference signal called Pilot-Tone (PT) and to use the PT signal for creation of motion-resolved images based on 3D stack-of-stars imaging under free-breathing conditions. METHODS: This work explores the use of a reference RF signal generated by a small RF transmitter, placed outside the MR bore. The reference signal is received in parallel to the MR signal during each readout. Because the received PT amplitude is modulated by the subject's breathing pattern, a respiratory signal can be obtained by detecting the strength of the received PT signal over time. The breathing-induced PT signal modulation can then be used for reconstructing motion-resolved images from free-breathing scans. The PT approach was tested in volunteers using a radial stack-of-stars 3D gradient echo (GRE) sequence with golden-angle acquisition. RESULTS: Respiratory signals derived from the proposed PT method were compared to signals from a respiratory cushion sensor and k-space-center-based self-navigation under different breathing conditions. Moreover, the accuracy was assessed using a modified acquisition scheme replacing the golden-angle scheme by a zero-angle acquisition. Incorporating the PT signal into eXtra-Dimensional (XD) motion-resolved reconstruction led to improved image quality and clearer anatomical depiction of the lung and liver compared to k-space-center signal and motion-averaged reconstruction, when binned into 6, 8, and 10 motion states. CONCLUSION: PT is a novel concept for tracking respiratory motion. Its small dimension (8 cm), high sampling rate, and minimal interaction with the imaging scan offers great potential for resolving respiratory motion.


Assuntos
Artefatos , Técnicas de Imagem de Sincronização Respiratória , Humanos , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Movimento (Física) , Respiração
16.
J Magn Reson Imaging ; 54(2): 440-451, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33694310

RESUMO

BACKGROUND: Respiratory gating is generally recommended in 4D flow MRI of the heart to avoid blurring and motion artifacts. Recently, a novel automated contact-less camera-based respiratory motion sensor has been introduced. PURPOSE: To compare camera-based respiratory gating (CAM) with liver-lung-navigator-based gating (NAV) and no gating (NO) for whole-heart 4D flow MRI. STUDY TYPE: Retrospective. SUBJECTS: Thirty two patients with a spectrum of cardiovascular diseases. FIELD STRENGTH/SEQUENCE: A 3T, 3D-cine spoiled-gradient-echo-T1-weighted-sequence with flow-encoding in three spatial directions. ASSESSMENT: Respiratory phases were derived and compared against each other by cross-correlation. Three radiologists/cardiologist scored images reconstructed with camera-based, navigator-based, and no respiratory gating with a 4-point Likert scale (qualitative analysis). Quantitative image quality analysis, in form of signal-to-noise ratio (SNR) and liver-lung-edge (LLE) for sharpness and quantitative flow analysis of the valves were performed semi-automatically. STATISTICAL TESTS: One-way repeated measured analysis of variance (ANOVA) with Wilks's lambda testing and follow-up pairwise comparisons. Significance level of P ≤ 0.05. Krippendorff's-alpha-test for inter-rater reliability. RESULTS: The respiratory signal analysis revealed that CAM and NAV phases were highly correlated (C = 0.93 ± 0.09, P < 0.01). Image scoring showed poor inter-rater reliability and no significant differences were observed (P ≥ 0.16). The image quality comparison showed that NAV and CAM were superior to NO with higher SNR (P = 0.02) and smaller LLE (P < 0.01). The quantitative flow analysis showed significant differences between the three respiratory-gated reconstructions in the tricuspid and pulmonary valves (P ≤ 0.05), but not in the mitral and aortic valves (P > 0.05). Pairwise comparisons showed that reconstructions without respiratory gating were different in flow measurements to either CAM or NAV or both, but no differences were found between CAM and NAV reconstructions. DATA CONCLUSION: Camera-based respiratory gating performed as well as conventional liver-lung-navigator-based respiratory gating. Quantitative image quality analysis showed that both techniques were equivalent and superior to no-gating-reconstructions. Quantitative flow analysis revealed local flow differences (tricuspid/pulmonary valves) in images of no-gating-reconstructions, but no differences were found between images reconstructed with camera-based and navigator-based respiratory gating. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.


Assuntos
Imageamento por Ressonância Magnética , Técnicas de Imagem de Sincronização Respiratória , Artefatos , Humanos , Imageamento Tridimensional , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído
17.
Am J Respir Crit Care Med ; 202(7): 1024-1031, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32459506

RESUMO

Rationale: Bronchopulmonary dysplasia is a heterogeneous lung disease characterized by regions of cysts and fibrosis, but methods for evaluating lung function are limited to whole lung rather than specific regions of interest.Objectives: Respiratory-gated, ultrashort echo time magnetic resonance imaging was used to test the hypothesis that cystic regions of the lung will exhibit a quantifiable Vt that will correlate with ventilator settings and clinical outcomes.Methods: Magnetic resonance images of 17 nonsedated, quiet-breathing infants with severe bronchopulmonary dysplasia were reconstructed into end-inspiration and end-expiration images. Cysts were identified and measured by using density threshold combined with manual identification and segmentation. Regional Vts were calculated by subtracting end-expiration from end-inspiration volumes in total lung, noncystic lung, total-cystic lung, and individual large cysts.Measurements and Main Results: Cystic lung areas averaged larger Vts than noncystic lung when normalized by volume (0.8 ml Vt/ml lung vs. 0.1 ml Vt/ml lung, P < 0.002). Cyst Vt correlates with cyst size (P = 0.012 for total lung cyst and P < 0.002 for large cysts), although there was variability between individual cyst Vt, with 22% of cysts demonstrating negative Vt. Peak inspiratory pressure positively correlated with total lung Vt (P = 0.027) and noncystic Vt (P = 0.015) but not total lung cyst Vt (P = 0.8). Inspiratory time and respiratory rate did not improve Vt of any analyzed lung region.Conclusions: Cystic lung has greater normalized Vt when compared with noncystic lung. Ventilator pressure increases noncystic lung Vt, but inspiratory time does not correlate with Vt of normal or cystic lung.


Assuntos
Displasia Broncopulmonar/diagnóstico por imagem , Cistos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Respiração Artificial/métodos , Volume de Ventilação Pulmonar/fisiologia , Displasia Broncopulmonar/fisiopatologia , Displasia Broncopulmonar/terapia , Cistos/fisiopatologia , Feminino , Humanos , Imageamento Tridimensional , Lactente , Lactente Extremamente Prematuro , Recém-Nascido , Masculino , Técnicas de Imagem de Sincronização Respiratória
18.
Magn Reson Med ; 83(1): 45-55, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31452244

RESUMO

PURPOSE: To implement, optimize, and test fast interrupted steady-state (FISS) for natively fat-suppressed free-running 5D whole-heart MRI at 1.5 tesla (T) and 3T. METHODS: FISS was implemented for fully self-gated free-running cardiac- and respiratory-motion-resolved radial imaging of the heart at 1.5T and 3T. Numerical simulations and phantom scans were performed to compare fat suppression characteristics and to determine parameter ranges (number of readouts [NR] per FISS module and TR) for effective fat suppression. Subsequently, free-running FISS data were collected in 10 healthy volunteers and images were reconstructed with compressed sensing. All acquisitions were compared with a continuous balanced steady-state free precession version of the same sequence, and both fat suppression and scan times were analyzed. RESULTS: Simulations demonstrate a variable width and location of suppression bands in FISS that were dependent on TR and NR. For a fat suppression bandwidth of 100 Hz and NR ≤ 8, simulations demonstrated that a TR between 2.2 ms and 3.0 ms is required at 1.5T, whereas a range of 3.0 ms to 3.5 ms applies at 3T. Fat signal increases with NR. These findings were corroborated in phantom experiments. In volunteers, fat SNR was significantly decreased using FISS compared with balanced steady-state free precession (P < 0.05) at both field strengths. After protocol optimization, high-resolution (1.1 mm3 ) 5D whole-heart free-running FISS can be performed with effective fat suppression in under 8 min at 1.5T and 3T at a modest scan time increase compared to balanced steady-state free precession. CONCLUSION: An optimal FISS parameter range was determined enabling natively fat-suppressed 5D whole-heart free-running MRI with a single continuous scan at 1.5T and 3T, demonstrating potential for cardiac imaging and noncontrast angiography.


Assuntos
Radicais Livres , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Técnicas de Imagem de Sincronização Respiratória , Algoritmos , Simulação por Computador , Angiografia Coronária , Eletrocardiografia , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Modelos Teóricos , Movimento (Física) , Distribuição Normal , Imagens de Fantasmas , Razão Sinal-Ruído
19.
Magn Reson Med ; 83(2): 635-644, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31464355

RESUMO

PURPOSE: To minimize respiratory motion artifacts while achieving predictable scan times with 100% scan efficiency for thoracic 4D flow MRI. METHODS: A 4D flow sequence with golden radial phase encoding (GRPE) was acquired in 9 healthy volunteers covering the heart, aorta, and venae cavae. Scan time was 15 min, and data were acquired without motion gating during acquisition. Data were retrospectively re-binned into respiratory and cardiac phases based on respiratory self-navigation and the electrocardiograph signals, respectively. Nonrigid respiratory motion fields were extracted and corrected for during the k-t SENSE reconstruction. A respiratory-motion corrected (GRPE-MOCO) and a free-breathing (GRPE-UNCORR) 4D flow dataset was reconstructed using 100% of the acquired data. For comparison, a respiratory gated Cartesian 4D flow acquisition (CART-REF) covering the aorta was acquired. Stroke volumes and peak flows were compared. Additionally, an internal flow validation based on mass conservation was performed on the GRPE-MOCO and GRPE-UNCORR. Statistically significant differences were analyzed using a paired Wilcoxon test. RESULTS: Stroke volumes and peak flows in the aorta between GRPE-MOCO and the CART-REF showed a mean difference of -1.5 ± 10.3 mL (P > 0.05) and 25.2 ± 55.9 mL/s (P > 0.05), respectively. Peak flow in the GRPE-UNCORR data was significantly different compared with CART-REF (P < 0.05). GRPE-MOCO showed higher accuracy for internal consistency analysis than GRPE-UNCORR. CONCLUSION: The proposed 4D flow sequence allows a straight-forward planning by covering the entire thorax and ensures a predictable scan time independent of cardiac cycle variations and breathing patterns.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Respiração , Técnicas de Imagem de Sincronização Respiratória/métodos , Tórax/diagnóstico por imagem , Adulto , Algoritmos , Aorta/diagnóstico por imagem , Eletrocardiografia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Movimento (Física) , Reprodutibilidade dos Testes , Adulto Jovem
20.
Magn Reson Med ; 83(3): 795-805, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31448841

RESUMO

PURPOSE: Respiratory gating in cardiac water-suppressed (WS) proton spectroscopy leads to long and unpredictable scan times. Metabolite cycling allows to perform frequency and phase correction on the water signal and, hence, offers an approach to navigator-free cardiac spectroscopy with fixed scan time. The objective of the present study was to develop and implement navigator-free metabolite-cycled cardiac proton spectroscopy (MC nonav) and compare it with standard navigator-gated WS (WS nav) and navigator-free WS (WS nonav) measurements for the assessment of triglyceride-to-water ratios (TG/W) and creatine-to-water ratios (CR/W) in the intraventricular septum of the in vivo heart. METHODS: Navigator-free metabolite-cycled spectroscopy was implemented on a clinical 1.5T system. In vivo measurements were performed on 10 young and 5 older healthy volunteers to assess signal-to-noise ratio efficiency as well as TG/W and CR/W and the relative Cramér-Rao lower bounds for CR. The performance of the metabolite-cycled sequence was verified using simulations. RESULTS: On average, scan times of MC nonav were 3.4 times shorter compared with WS nav, while no significant bias for TG/W was observed (coefficient of variation = 14.0%). signal-to-noise ratio efficiency of both TG and CR increased for MC nonav compared with WS nav. Relative Cramér-Rao lower bounds of CR decreased for MC nonav. Overall spectral quality was found comparable between MC nonav and WS nav, while it was inferior for WS nonav. CONCLUSION: Navigator-free metabolite-cycled cardiac proton spectroscopy offers 3.4-fold accelerated assessment of TG/W and CR/W in the heart with preserved spectral quality when compared with navigator-gated WS scans.


Assuntos
Septos Cardíacos/diagnóstico por imagem , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Técnicas de Imagem de Sincronização Respiratória , Espectrofotometria , Adulto , Idoso , Algoritmos , Simulação por Computador , Creatina/química , Feminino , Voluntários Saudáveis , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Prótons , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Triglicerídeos/química , Água , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA