Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 338
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Pediatr Res ; 95(4): 1124-1131, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38092963

RESUMO

BACKGROUND: Cardiovascular support (CVS) treatment failure (TF) is associated with a poor prognosis in preterm infants. METHODS: Medical charts of infants with a birth weight <1500 g who received either dopamine (Dp) or dobutamine (Db), were reviewed. Treatment response (TR) occurred if blood pressure increased >3rd centile for gestational age or superior vena cava flow was maintained >55 ml/kg/min, with decreased lactate or less negative base excess, without additional CVS. A predictive model of Dp and Db on TR was designed and the impact of TR on survival was analyzed. RESULTS: Sixty-six infants (median gestational age 27.3 weeks, median birth weight 864 g) received Dp (n = 44) or Db (n = 22). TR occurred in 59% of the cases treated with Dp and 31% with Db, p = 0.04. Machine learning identified a model that correctly labeled Db response in 90% of the cases and Dp response in 61.4%. Sixteen infants died (9% of the TR group, 39% of the TF group; p = 0.004). Brain or gut morbidity-free survival was observed in 52% vs 30% in the TR and TF groups, respectively (p = 0.08). CONCLUSIONS: New predictive models can anticipate Db but not Dp effectiveness in preterm infants. These algorithms may help the clinicians in the decision-making process. IMPACT: Failure of cardiovascular support treatment increases the risk of mortality in very low birth weight infants. A predictive model built with machine learning techniques can help anticipate treatment response to dobutamine with high accuracy. Predictive models based on artificial intelligence may guide the clinicians in the decision-making process.


Assuntos
Doenças Cardiovasculares , Recém-Nascido Prematuro , Lactente , Recém-Nascido , Humanos , Recém-Nascido Prematuro/fisiologia , Dobutamina/uso terapêutico , Peso ao Nascer , Veia Cava Superior/fisiologia , Inteligência Artificial , Dopamina/uso terapêutico , Recém-Nascido de muito Baixo Peso
2.
J Pediatr ; 257: 113383, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36914049

RESUMO

OBJECTIVE: To assess the hemodynamic safety and efficacy of umbilical cord milking (UCM) compared with early cord clamping (ECC) in nonvigorous newborn infants enrolled in a large multicenter randomized cluster-crossover trial. STUDY DESIGN: Two hundred twenty-seven nonvigorous term or near-term infants who were enrolled in the parent UCM vs ECC trial consented for this substudy. An echocardiogram was performed at 12 ± 6 hours of age by ultrasound technicians blinded to randomization. The primary outcome was left ventricular output (LVO). Prespecified secondary outcomes included measured superior vena cava (SVC) flow, right ventricular output (RVO), peak systolic strain, and peak systolic velocity by tissue Doppler examination of the RV lateral wall and the interventricular septum. RESULTS: Nonvigorous infants receiving UCM had increased hemodynamic echocardiographic parameters as measured by higher LVO (225 ± 64 vs 187 ± 52 mL/kg/min; P < .001), RVO (284 ± 88 vs 222 ± 96 mL/kg/min; P < .001), and SVC flow (100 ± 36 vs 86 ± 40 mL/kg/min; P < .001) compared with the ECC group. Peak systolic strain was lower (-17 ± 3 vs -22 ± 3%; P < .001), but there was no difference in peak tissue Doppler flow (0.06 m/s [IQR, 0.05-0.07 m/s] vs 0.06 m/s [IQR, 0.05-0.08 m/s]). CONCLUSIONS: UCM increased cardiac output (as measured by LVO) compared with ECC in nonvigorous newborns. Overall increases in measures of cerebral and pulmonary blood flow (as measured by SVC and RVO flow, respectively) may explain improved outcomes associated with UCM (less cardiorespiratory support at birth and fewer cases of moderate-to-severe hypoxic ischemic encephalopathy) among nonvigorous newborn infants.


Assuntos
Recém-Nascido Prematuro , Clampeamento do Cordão Umbilical , Lactente , Gravidez , Feminino , Recém-Nascido , Humanos , Recém-Nascido Prematuro/fisiologia , Estudos Cross-Over , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/fisiologia , Cordão Umbilical/diagnóstico por imagem , Hemodinâmica/fisiologia , Constrição
3.
Eur J Pediatr ; 182(4): 1839-1845, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36795189

RESUMO

To evaluate feasibility, reproducibility, and prognostic value of a new echocardiographic method to assess systemic arterial blood flow directed to the upper part of the body (UBAF, upper body arterial flow) alternative to superior vena cava flow (SVCF) measurement. We performed echocardiographic evaluations in 106 infants in the first 2 days of life to obtain SVCF, left ventricle output (LVO), UBAF, and standard parameters of patent ductus arteriosus (PDA) significance. UBAF was calculated by subtracting from LVO the aortic arch blood flow measured immediately distally to the origin of the left subclavian artery. Main outcome measures: UBAF and SVCF agreement was assessed by Bland-Altman analysis in terms of bias, limits of agreement and repeatability index. The Intraclass Correlation Coefficient was used to measure the strength of inter-rater agreement. The agreement between UBAF and SVCF was high. The Concordance Correlation Coefficient (CCC) was 0.7434. (CCC 0.7434, 95% C.I. [0.656, 0.8111]). There was a good absolute agreement between the two raters ICC = 0.747; p value < 0.0001; 95%CI [0.601; 0.845]. Adjusting for confounding factors (BW, GA, PDA) included in the model, there was a statistically significant relationship between UBAF and SVCF. CONCLUSION: UBAF showed a strong agreement with the SCVF with a better reproducibility. Our data support UBAF as a potentially useful marker of cerebral perfusion in the evaluation of preterm infants. WHAT IS KNOWN: • Low SVC (superior vena cava) flow in the neonatal period has been associated with periventricular haemorrhage and unfavourable long-term neurodevelopmental outcome. • Ultrasound measurement of flow in SVC shows relatively high inter-operator variability. WHAT IS NEW: • Our study highlights how much overlap there is between upper-body arterial flow (UBAF) measurement and SCV flow measurement. UBAF is easier to perform and has a strong correlation with better reproducibility. • UBAF may replace measurement of cava flow as a method for haemodynamic monitoring of unstable preterm and asphyxiated infants.


Assuntos
Permeabilidade do Canal Arterial , Recém-Nascido Prematuro , Lactente , Recém-Nascido , Humanos , Recém-Nascido Prematuro/fisiologia , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/fisiologia , Reprodutibilidade dos Testes , Hemodinâmica , Ecocardiografia , Permeabilidade do Canal Arterial/diagnóstico por imagem
4.
Eur J Pediatr ; 181(12): 4121-4133, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36129535

RESUMO

Despite of growing evidence of the beneficial effects of placental transfusion techniques, there is no available sufficient data about their effects on vulnerable hemodynamics and myocardium of premature infants. The purpose of this work is to study ventricular functions and hemodynamics after applying different placental transfusion techniques, delayed cord clamping (DCC), cut cord milking (C-UCM), and intact cord milking (I-UCM). Sixty-four infants delivered whether by C-section or vaginal delivery were randomly assigned to undergo C-UCM (20-30 cm), I-UCM (3-4 strippings), and DCC (30-60 s). Functional echocardiography was done on day 1 and day 3 of life for 57 infants. Primary outcome variable was superior vena cava flow measurement in infants having placental transfusion in the first 24 h of life and between 64 and 72 h. Secondary outcomes were other echocardiographic and clinical hemodynamic parameters, and biventricular functions in those infants. Of a total 196 preterm infants ≤ 32 weeks delivered in the study period, from January 2021 to August 2021, 57 infants were eligible and survived till the second examination. They were randomly assigned to the three groups. Neonates randomly assigned to DCC had significantly higher superior vena cava flow and lower right ventricular systolic function in the first 24 h of life. This finding vanished at day 3. Neonates undergone different methods of placental transfusions had similar hemoglobin, admission temperature, and mean blood pressure in the first 24 h of life. CONCLUSION: Despite their potential benefits, placental transfusions have shown to alter the hemodynamics and adversely affect myocardial function of premature neonates. TRIAL REGISTRATION: This trial was registered in the clinical trial gov NCT04811872. WHAT IS KNOWN: • Placental transfusion techniques might have benefits regarding prematurity- related morbidities and mortality. WHAT IS NEW: • Placental transfusion might adversely affect the myocardium and alter hemodynamics in premature infants.


Assuntos
Doenças do Prematuro , Recém-Nascido Prematuro , Lactente , Recém-Nascido , Feminino , Gravidez , Humanos , Constrição , Cordão Umbilical , Clampeamento do Cordão Umbilical , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/fisiologia , Placenta/fisiologia , Hemodinâmica/fisiologia
5.
Eur J Pediatr ; 181(12): 4067-4077, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36171508

RESUMO

Unstable hemodynamics and prematurity are the main players in intraventricular hemorrhage (IVH) development. Our objective was to study 8 the use of superior vena cava flow (SVCF), left ventricular output (LVO), and right ventricular output (RVO), and anterior cerebral artery (ACA) Doppler measures in prediction of IVH in the first week of life in preterm infant ≤ 32 weeks and birth weight ≤ 1500 g. This prospective cohort study was conducted in 55NICU of Alexandria University maternity hospital. Of 147 enrolled patients, 132 infants born ≤ 32 weeks GA and birth weight ≤ 1500 g were eligible for- the study. One hundred twenty-seven infants completed the study. Infants were scanned for ACA-RI using transfontanellar ultrasound, and SVCF, LVO, and RVO using functional echocardiography in the first 24 h after birth. Patients had another two scans on DOL3 and 7 to detect IVH development. Low SVCF and high ACA-RI significantly increased the risk of IVH using logistic regression models with OR, 3.16; 95%CI, 1.19-8.39; P = 0.02 and OR, 1.64; 95%Cl, 1.10-2.44; P = 0.02, respectively. Low SVCF and high ACA-RI significantly increased risk of catastrophic IVH P = 0.025 and 0.023, respectively. Combined use of low SVCF < 55 ml/kg/min and ACA-RI > 0.75 is predictor of IVH with sensitivity 40.8% and 82.1% specificity. CONCLUSIONS: There are strong relations between both low SVCF and high ACA-RI, and IVH development in premature neonates ≤ 32 weeks and birth weight ≤ 1500 g, with more significance towards catastrophic IVH. Admission RSS and LVO are the strongest factors affecting SVCF. Maternal anemia, patent ductus arteriosus size (mm/kg), and capillary refill time were significantly associated with high ACA-RI. These findings help in more understanding of pathophysiological factors affecting central perfusion that might affect the longer term neurodeveopmental outcome. TRIAL REGISTRATION: This work was registered in clinical trial.gv no NCT05050032. WHAT IS KNOWN: •Whether SVCF and RI-ACA can predict IVH in preterm neonates is still debatable. WHAT IS NEW: •Low SVC flow and high ACA-RI significantly increased risk of IVH, confirming the role of hypoperfusion-reperfusion cycle in IVH development. The most striking result that combined metrics using the cut-off value of < 41 ml/kg/min for SVCF and > 0.85 for ACA-RI "in the first day of life" can correctly reject the presence of IVH in 98% of patients "during the first week of life."


Assuntos
Doenças do Recém-Nascido , Doenças do Prematuro , Feminino , Humanos , Recém-Nascido , Gravidez , Peso ao Nascer , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/etiologia , Circulação Cerebrovascular/fisiologia , Hemodinâmica/fisiologia , Recém-Nascido Prematuro/fisiologia , Doenças do Prematuro/diagnóstico por imagem , Doenças do Prematuro/etiologia , Estudos Prospectivos , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/fisiologia
6.
BMC Pediatr ; 22(1): 256, 2022 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-35524194

RESUMO

BACKGROUND: Delayed cord clamping (DCC) is practiced worldwide, as standard care in both term and preterm babies. Our aim was to determine the hemodynamic effects of DCC on transitional circulation. MATERIAL AND METHODS: This prospective observational study was carried out in a tertiary care hospital, at Pune, India, from May 2018 to October 2019.Term neonates born during the study period were included. The primary outcome variables of the study were right ventricular output (RVO), left ventricular output (LVO), superior vena cava (SVC) flow (ml/kg/min) and heart rate(HR) at 12 ± 6 and 48 ± 6 h of life measured by point of care functional echocardiography. Inter-observer and intra-observer variability was calculated for these parameters. RESULTS: Out of a total of 2744 deliveries during the study period, 620 babies were included. Mean gestational age of the enrolled babies was 38.96 ± 1.08 weeks and mean birth weight was 2.9 ± 0.39 kg. Mean heart rate of babies recorded at 12 ± 6 h of life was 127 beats per minute (bpm) whereas it was 128 bpm at 48 ± 6 h of life. RVO {mean (SD)} was 209.55(44.89) and 205.85(46.35) ml/kg/min, LVO {mean (SD)} was 133.68(31.15) and 134.78(29.84) ml/kg/min whereas SVC flow {mean (SD)} was 106.85(26.21) and 109.29(25.11) ml/kg/min at 12 ± 6 and 48 ± 6 h of life respectively. There was good intra-observer agreement in all the variables. SGA babies had a significantly higher heart rate at 12 ± 6 h of life as compared to AGA babies, although this difference in heart rate could not be appreciated at 48 ± 6 h of life. However SGA babies had a higher LVO, RVO and SVC flow than AGA babies at both the time points of observation. CONCLUSION: After DCC there is less fluctuation in the hemodynamic parameters (heart rate, cardiac output) at the two time points of observation.. As compared to AGA babies, SGA babies had a significantly higher baseline heart rate, LVO, RVO and SVC flow. LVO of SGA babies after delayed cord clamping is found to be significantly lower than LVO seen in other studies, favoring the cardio-stabilizing effect of DCC. BRIEF RATIONALE: This is the first study with a large sample size evaluating the hemodynamic effects of DCC in term neonates by functional echocardiography. The normative data of heart rate and cardiac output of term, stable babies with small for gestational age(SGA) as a special subgroup undergoing DCC requires further evaluation.


Assuntos
Recém-Nascido Prematuro , Clampeamento do Cordão Umbilical , Veia Cava Superior , Constrição , Feminino , Hemodinâmica/fisiologia , Humanos , Índia , Lactente , Recém-Nascido , Recém-Nascido Prematuro/fisiologia , Gravidez , Cordão Umbilical , Veia Cava Superior/fisiologia
7.
BMC Pregnancy Childbirth ; 21(1): 158, 2021 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-33622280

RESUMO

BACKGROUND: Fetal superior vena cava (SVC) is essentially the single vessel returning blood from the upper body to the heart. With approximately 80-85% of SVC blood flow representing cerebral venous return, its interrogation may provide clinically relevant information about fetal brain circulation. However, normal reference values for fetal SVC Doppler velocities and pulsatility index are lacking. Our aim was to establish longitudinal reference intervals for blood flow velocities and pulsatility index of the SVC during the second half of pregnancy. METHODS: This was a prospective study of low-risk singleton pregnancies. Serial Doppler examinations were performed approximately every 4 weeks to obtain fetal SVC blood velocity waveforms during 20-41 weeks. Peak systolic (S) velocity, diastolic (D) velocity, time-averaged maximum velocity (TAMxV), time-averaged intensity-weighted mean velocity (TAMeanV), and end-diastolic velocity during atrial contraction (A-velocity) were measured. Pulsatility index for vein (PIV) was calculated. RESULTS: SVC blood flow velocities were successfully recorded in the 134 fetuses yielding 510 sets of observations. The velocities increased significantly with advancing gestation: mean S-velocity increased from 24.0 to 39.8 cm/s, D-velocity from 13.0 to 19.0 cm/s, and A-velocity from 4.8 to 7.1 cm/s. Mean TAMxV increased from 12.7 to 23.1 cm/s, and TAMeanV from 6.9 to 11.2 cm/s. The PIV remained stable at 1.5 throughout the second half of pregnancy. CONCLUSIONS: Longitudinal reference intervals of SVC blood flow velocities and PIV were established for the second half of pregnancy. The SVC velocities increased with advancing gestation, while the PIV remained stable from 20 weeks to term.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Coração Fetal/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Veia Cava Superior/fisiologia , Feminino , Coração Fetal/diagnóstico por imagem , Humanos , Gravidez , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Valores de Referência , Ultrassonografia Doppler , Ultrassonografia Pré-Natal , Veia Cava Superior/diagnóstico por imagem
8.
Artif Organs ; 45(8): 893-902, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33471364

RESUMO

The performance of each veno-venous extracorporeal membrane oxygenation (vv-ECMO) configuration is determined by the anatomic context and cannula position. A mathematical model was built considering bicaval specificities to simulate femoro-jugular configuration. The main parameters to define were cardiac output (QC ), blood flow in the superior vena cava (QSVC ), extracorporeal pump flow (QEC ), and pulmonary shunt (kS-PULM ). The obtained variables were extracorporeal flow ratio in the superior vena cava (EFRSVC  = QEC /[QEC  + QSVC ]), recirculation coefficient (R), effective extracorporeal pump flow (Qeff-EC  = [1 - R] × QEC ), Qeff-EC /QC ratio, and arterial blood oxygen saturation (SaO2 ). EFRSVC increased logarithmically when QEC increased. High QC or high QSVC /QC decreased EFRSVC (range, 68%-85% for QEC of 5 L/min). R also increased following a logarithmic shape when QEC increased. The R rise was earlier and higher for low QC and high QSVC /QC (range, 12%-49% for QEC of 5 L/min). The Qeff-EC /QC ratio (between 0 and 1) was equal to EFRSVC for moderate and high QEC . The Qeff-EC /QC ratio presented the same logarithmic profile when QEC increased, reaching a plateau (range, 0.67-0.91 for QEC /QC  = 1; range, 0.75-0.94 for QEC /QC  = 1.5). The Qeff-EC /QC ratio was linearly associated with SaO2 for a given pulmonary shunt. SaO2  < 90% was observed when the pulmonary shunt was high (Qeff-EC /QC  ≤ 0.7 with kS-PULM  = 0.7 or Qeff-EC /QC  ≤ 0.8 with kS-PULM  = 0.8). Femoro-jugular vv-ECMO generates a systematic structural recirculation that gradually increases with QEC . EFRSVC determines the Qeff-EC /QC ratio, and thereby oxygen delivery and the superior cava shunt. EFRSVC cannot exceed a limit value, explaining refractory hypoxemia in extreme situations.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Síndrome do Desconforto Respiratório/terapia , Veia Femoral/fisiologia , Humanos , Hipóxia , Veias Jugulares/fisiologia , Modelos Estatísticos , Veia Cava Superior/fisiologia
9.
Pflugers Arch ; 471(11-12): 1493-1503, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31654199

RESUMO

The electrophysiological properties of the superior vena cava (SVC) myocardium, which is considered a minor source of atrial arrhythmias, were studied in this study during postnatal development. Conduction properties were investigated in spontaneously active and electrically paced SVC preparations obtained from 7-60-day-old male Wistar rats using optical mapping and microelectrode techniques. The presence of high-conductance connexin 43 (Cx43) was evaluated in SVC cross-sections using immunofluorescence. It was found that SVC myocardium is excitable, electrically coupled with the atrial tissue, and conducts excitation waves at all stages of postnatal development. However, the conduction velocity (CV) of excitation and action potential (AP) upstroke velocity in SVC were significantly lower in neonatal than in adult animals and increased with postnatal maturation. Connexins Cx43 were identified in both neonatal and adult rat SVC myocardium; however, the abundance of Cx43 was significantly less in neonates. The gap junction uncoupler octanol affected conduction more profound in the neonatal than in adult SVC. We demonstrated for the first time that the conduction characteristics of SVC myocardium change from a slow-conduction (nodal) to a high-conduction (working) phenotype during postnatal ontogenesis. An age-related CV increase may occur due to changes of AP characteristics, electrical coupling, and Cx43 presence in SVC cardiomyocyte membranes. Observed changes may contribute to the low proarrhythmicity of adult caval vein cardiac tissue, while pre- or postnatal developmental abnormalities that delay the establishment of the working conduction phenotype may facilitate SVC proarrhythmia.


Assuntos
Sistema de Condução Cardíaco/fisiologia , Miocárdio/patologia , Veia Cava Superior/fisiologia , Potenciais de Ação/fisiologia , Animais , Fibrilação Atrial/metabolismo , Fibrilação Atrial/fisiopatologia , Ontologias Biológicas , Conexina 43/metabolismo , Feminino , Junções Comunicantes/metabolismo , Junções Comunicantes/fisiologia , Átrios do Coração/metabolismo , Sistema de Condução Cardíaco/metabolismo , Masculino , Miocárdio/metabolismo , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/fisiologia , Ratos , Ratos Wistar , Veia Cava Superior/metabolismo
10.
Pediatr Res ; 86(1): 71-76, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30791040

RESUMO

OBJECTIVE: To determine associations of low superior vena cava (SVC) flow (≤55 ml/kg/min) and low right ventricular output (RVO) (≤150 ml/kg/min) in preterm infants. DESIGN/METHODS: An observational study in infants <30 weeks gestation randomized to receive immediate (<10 s) or delayed cord clamping (DCC) (≥60 s). RESULTS: The study enrolled 265 infants with a mean (SD) gestation 28 (2) weeks. Eighty-six (33%) infants had low SVC flow and 81 (31%) infants had low RVO. In multivariate analysis, low SVC flow was associated with gestation; low RVO was associated with DCC, gender and 5-minute Apgar; whereas mean RVO was negatively associated with both FiO2 and mean airway pressure (MAP) at 9 h and 24 h. Low SVC flow was associated with ductus arteriosus (DA) treatment. Infants with low RVO had higher mortality on univariate analysis, but this was not significant after adjusting for gestation. CONCLUSIONS: SVC flow was associated with gestation, whilst RVO was associated with placental transfusion, gender, condition at birth, and early respiratory adaptation. Compared to infants with normal values, more infants with low SVC flow were treated for DA, but infants with low RVO had no significant difference in mortality or morbidity.


Assuntos
Velocidade do Fluxo Sanguíneo , Hemodinâmica , Instrumentos Cirúrgicos , Cordão Umbilical/fisiologia , Veia Cava Superior/fisiologia , Austrália , Transfusão de Sangue , Constrição , Canal Arterial/fisiologia , Feminino , Idade Gestacional , Ventrículos do Coração , Humanos , Recém-Nascido , Recém-Nascido Prematuro/fisiologia , Terapia Intensiva Neonatal , Masculino , Análise Multivariada , Placenta/fisiologia , Gravidez , Pressão , Estudos Prospectivos
11.
J Korean Med Sci ; 33(4): e25, 2018 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-29318792

RESUMO

BACKGROUND: In preterm infants, caffeine citrate is used to stimulate breathing before they are weaned from mechanical ventilation and to reduce the frequency of apnea. In recent studies, effects of caffeine on the cardiovascular system have been emphasized in preterm infants with patent ductus arteriosus (PDA). METHODS: This study aimed to assess the short-term hemodynamic effects on systemic blood flow and ductal shunting flow after loading standard doses of intravenous caffeine in preterm infants. Echocardiographic studies were performed by a single investigator, before and at 1 hour and 4 hours after an intravenous infusion of a loading dose as 20 mg/kg caffeine citrate for 30 minutes. RESULTS: In 25 preterm infants with PDA, left ventricular output decreased progressively during 4 hours after caffeine loading. Superior vena cava (SVC) flow decreased and ductal shunting flow increased at 1 hour and then recovered at 4-hour to baseline values. A diameter of PDA significantly decreased only at 4-hour after caffeine loading. There were no significant changes of these hemodynamic parameters in 29 preterm infants without PDA. CONCLUSION: In preterm infants with PDA, a standard intravenous loading dose of 20 mg/kg caffeine citrate was associated with increasing ductal shunting flow and decreasing SVC flow (as a surrogate for systemic blood flow) 1 hour after caffeine loading, however, these hemodynamic parameters recovered at 4 hours according to partial constriction of the ductus arteriosus. Close monitoring of hemodynamic changes would be needed to observe the risk for pulmonary over-circulation or systemic hypo-perfusion due to transient increasing ductal shunting flow during caffeine loading in preterm infants with PDA.


Assuntos
Cafeína/uso terapêutico , Citratos/uso terapêutico , Permeabilidade do Canal Arterial/tratamento farmacológico , Hemodinâmica/efeitos dos fármacos , Administração Intravenosa , Peso ao Nascer , Cafeína/farmacologia , Citratos/farmacologia , Canal Arterial/fisiologia , Permeabilidade do Canal Arterial/fisiopatologia , Ecocardiografia , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Veia Cava Superior/fisiologia
12.
Am J Physiol Heart Circ Physiol ; 313(2): H408-H420, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28550170

RESUMO

The relevance of right atrial pressure (RAP) as the backpressure for venous return (QVR) and mean systemic filling pressure as upstream pressure is controversial during dynamic changes of circulation. To examine the immediate response of QVR (sum of caval vein flows) to changes in RAP and pump function, we used a closed-chest, central cannulation, heart bypass porcine preparation (n = 10) with venoarterial extracorporeal membrane oxygenation. Mean systemic filling pressure was determined by clamping extracorporeal membrane oxygenation tubing with open or closed arteriovenous shunt at euvolemia, volume expansion (9.75 ml/kg hydroxyethyl starch), and hypovolemia (bleeding 19.5 ml/kg after volume expansion). The responses of RAP and QVR were studied using variable pump speed at constant airway pressure (PAW) and constant pump speed at variable PAW Within each volume state, the immediate changes in QVR and RAP could be described with a single linear regression, regardless of whether RAP was altered by pump speed or PAW (r2 = 0.586-0.984). RAP was inversely proportional to pump speed from zero to maximum flow (r2 = 0.859-0.999). Changing PAW caused immediate, transient, directionally opposite changes in RAP and QVR (RAP: P ≤ 0.002 and QVR: P ≤ 0.001), where the initial response was proportional to the change in QVR driving pressure. Changes in PAW generated volume shifts into and out of the right atrium, but their effect on upstream pressure was negligible. Our findings support the concept that RAP acts as backpressure to QVR and that Guyton's model of circulatory equilibrium qualitatively predicts the dynamic response from changing RAP.NEW & NOTEWORTHY Venous return responds immediately to changes in right atrial pressure. Concomitant volume shifts within the systemic circulation due to an imbalance between cardiac output and venous return have negligible effects on mean systemic filling pressure. Guyton's model of circulatory equilibrium can qualitatively predict the resulting changes in dynamic conditions with right atrial pressure as backpressure to venous return.


Assuntos
Função do Átrio Direito , Pressão Atrial , Circulação Sanguínea , Ponte Cardiopulmonar , Modelos Cardiovasculares , Veia Cava Inferior/fisiologia , Veia Cava Superior/fisiologia , Adaptação Fisiológica , Animais , Oxigenação por Membrana Extracorpórea , Ligadura , Modelos Animais , Artéria Pulmonar/cirurgia , Respiração Artificial , Sus scrofa , Fatores de Tempo
13.
J Pediatr ; 178: 81-86.e2, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27574998

RESUMO

OBJECTIVE: To determine whether delayed cord clamping improves systemic blood flow compared with immediate cord clamping in very preterm infants in the first 24 hours. STUDY DESIGN: Women delivering at <30 weeks' gestation at 5 tertiary centers were randomized to receive immediate cord clamping (<10 seconds) or delayed cord clamping (≥60 seconds). Echocardiography and cardiorespiratory data were collected at 3, 9, and 24 hours after birth. The primary outcome was mean lowest superior vena cava (SVC) flow. RESULTS: Of 266 infants enrolled, 133 were randomized to immediate cord clamping and 133 to delayed cord clamping. The 2 groups were similar at baseline, including mean gestation (immediate cord clamping 28 weeks vs delayed cord clamping 28 weeks) and birth weight (immediate cord clamping 1003 g vs delayed cord clamping 1044 g). There was no significant difference between groups in the primary outcome of mean lowest SVC flow (immediate cord clamping 71.4 mL/kg/min [SD 28.1] vs delayed cord clamping 70.2 mL/kg/min [SD 26.9]; P = .7). For secondary outcomes, hemoglobin increased by 0.9 g/dL at 6 hours in the group with delayed cord clamping (95% CI 3.9, 14.4; P = .0005, adjusted for baseline). The group with delayed cord clamping had lower right ventricular output (-21.9 mL/kg/min, 95% CI -39.0, -4.7; P = .01). Rates of treated hypotension, ductus arteriosus size and shunt direction, and treatment of the ductus arteriosus were similar. CONCLUSIONS: Delayed cord clamping had no effect on systemic blood flow measured as mean lowest SVC flow in the first 24 hours in infants <30 weeks' gestation. TRIAL REGISTRATION: Australia New Zealand Clinical Trials Registry: ACTRN12610000633088.


Assuntos
Hemodinâmica/fisiologia , Recém-Nascido Prematuro/fisiologia , Cordão Umbilical/cirurgia , Veia Cava Superior/fisiologia , Austrália , Velocidade do Fluxo Sanguíneo , Constrição , Ecocardiografia , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro/sangue , Nova Zelândia , Fatores de Tempo
14.
Am J Obstet Gynecol ; 214(3): 367.e1-367.e17, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26475425

RESUMO

BACKGROUND: Late-onset intrauterine growth restriction (IUGR) results from a failure of the placenta to supply adequate nutrients and oxygen to the rapidly growing late-gestation fetus. Limitations in current monitoring methods present the need for additional techniques for more accurate diagnosis of IUGR in utero. New magnetic resonance imaging (MRI) technology now provides a noninvasive technique for fetal hemodynamic assessment, which could provide additional information over conventional Doppler methods. OBJECTIVE: The objective of the study was to use new MRI techniques to measure hemodynamic parameters and brain growth in late-onset IUGR fetuses. STUDY DESIGN: This was a prospective observational case control study to compare the flow and T2 of blood in the major fetal vessels and brain imaging findings using MRI. Indexed fetal oxygen delivery and consumption were calculated. Middle cerebral artery and umbilical artery pulsatility indexes and cerebroplacental ratio were acquired using ultrasound. A score of ≥ 2 of the 4 following parameters defined IUGR: (1) birthweight the third centile or less or 20% or greater drop in the centile in estimated fetal weight; (2) lowest cerebroplacental ratio after 30 weeks less than the fifth centile; (3) ponderal index < 2.2; and (4) placental histology meets predefined criteria for placental underperfusion. Measurements were compared between the 2 groups (Student t test) and correlations between parameters were analyzed (Pearson's correlation). MRI measurements were compared with Doppler parameters for identifying IUGR defined by postnatal criteria (birthweight, placental histology, ponderal index) using receiver-operating characteristic curves. RESULTS: We studied 14 IUGR and 26 non-IUGR fetuses at 35 weeks' gestation. IUGR fetuses had lower umbilical vein (P = .004) and pulmonary blood flow (P = .01) and higher superior vena caval flow (P < .0001) by MRI. IUGR fetuses had asymmetric growth but smaller brains than normal fetuses (P < .0001). Newborns with IUGR also had smaller brains with otherwise essentially normal findings on MRI. Vessel T2s, oxygen delivery, oxygen consumption, middle cerebral artery pulsatility index, and cerebroplacental ratio were all significantly lower in IUGR fetuses, whereas there was no significant difference in umbilical artery pulsatility index. IUGR score correlated positively with superior vena caval flow and inversely with oxygen delivery, oxygen consumption, umbilical vein T2, and cerebroplacental ratio. Receiver-operating characteristic curves revealed equivalent performance of MRI and Doppler techniques in identifying IUGR that was defined based on postnatal parameters with superior vena caval flow area under the curve of 0.94 (95% confidence interval, 0.87-1.00) vs a cerebroplacental ratio area under the curve of 0.80 (95% confidence interval, 0.64-0.97). CONCLUSION: MRI revealed the expected circulatory redistribution in response to hypoxia in IUGR fetuses. The reduced oxygen delivery in IUGR fetuses indicated impaired placental oxygen transport, whereas reduced oxygen consumption presumably reflected metabolic adaptation to diminished substrate delivery, resulting in slower fetal growth. Despite brain sparing, placental insufficiency limits fetal brain growth. Superior vena caval flow and umbilical vein T2 by MRI may be useful new markers of late-onset IUGR.


Assuntos
Peso ao Nascer , Encéfalo/embriologia , Retardo do Crescimento Fetal/diagnóstico , Retardo do Crescimento Fetal/fisiopatologia , Hemodinâmica , Imageamento por Ressonância Magnética , Adulto , Área Sob a Curva , Estudos de Casos e Controles , Circulação Cerebrovascular , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Humanos , Recém-Nascido , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/fisiologia , Oxigênio/metabolismo , Consumo de Oxigênio , Placenta/irrigação sanguínea , Placenta/patologia , Circulação Placentária , Gravidez , Terceiro Trimestre da Gravidez/fisiologia , Estudos Prospectivos , Fluxo Pulsátil , Curva ROC , Fluxo Sanguíneo Regional , Ultrassonografia Doppler , Artérias Umbilicais/diagnóstico por imagem , Artérias Umbilicais/fisiologia , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/fisiologia
15.
Pediatr Res ; 79(3): 460-5, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26539666

RESUMO

BACKGROUND: Impaired autoregulation capacity implies that changes in cerebral perfusion follow changes in blood pressure; however, no analytical method has explored such a signal causality relationship in infants. We sought to develop a method to assess cerebral autoregulation from a mechanistic point of view and explored the predictive capacity of the method to classify infants at risk for adverse outcomes. METHODS: The partial directed coherence (PDC) method, which considers synchronicity and directionality of signal dependence across frequencies, was used to analyze the relationship between spontaneous changes in mean arterial pressure (MAP) and the cerebral tissue oxygenation index (TOI). PDCMAP>>TOI indicated that changes in TOI were induced by MAP changes, and PDCTOI>>MAP indicated the opposite. RESULTS: The PDCMAP>>TOI and PDCTOI>>MAP values differed. PDCMAP>>TOI adjusted by gestational age predicted low superior vena cava flow (≤41 ml/kg per min), with an area under the receiver operating characteristic curve of 0.72 (95% CI: 0.63-0.81; P < 0.001), whereas PDCTOI>>MAP did not. The adjusted pPDCMAP>>TOI (the average value per patient) predicted severe intracranial hemorrhage and mortality. CONCLUSION: PDCMAP>>TOI allows for a noninvasive physiological interpretation of the pressure autoregulation process in neonates. PDCMAP>>TOI is a good classifier for infants at risk of brain hypoperfusion and adverse outcomes.


Assuntos
Circulação Cerebrovascular/fisiologia , Homeostase/fisiologia , Consumo de Oxigênio/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho , Pressão Arterial , Determinação da Pressão Arterial , Encéfalo/metabolismo , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Modelos Estatísticos , Oxigênio/sangue , Oxigênio/química , Perfusão , Curva ROC , Fatores de Risco , Sensibilidade e Especificidade , Resultado do Tratamento , Veia Cava Superior/fisiologia
16.
Eur J Vasc Endovasc Surg ; 51(2): 275-84, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26797052

RESUMO

OBJECTIVE: Positive external pressure is said to decrease transmural pressure; negative pressure in the pleural cavity is widely believed to result in negative pressure in systemic chest veins. The discrepancy between erect column height and foot venous pressure has been explained on this basis. METHODS: These core concepts rest on static closed models that may not be appropriate. This study examined the effects of external pressures in a dynamic open model that may better reflect in vivo conditions. Flow in a Penrose drain enclosed in a chamber that could be positively or negatively pressurized was used. Input and output reservoirs with pressures in the physiological range provided flow. Flow and pressure were monitored in horizontal and erect models with modifications to suit particular experiments. RESULTS: The discrepancy between foot venous pressure and erect venous column height was shown in this experimental model to be a result of two flows in opposite directions (superior and inferior vena cavae) meeting at the zero reference level at the heart; the upper column pressure therefore does not register at the foot. Positive external pressure results in slowing of velocity with conversion to pressure. Internal and transmural pressures therefore do not decrease. Negative external pressure has only a marginal effect on flow; importantly, internal pressure does not become negative. In an experimental set-up it was shown that negative pressure in chest veins was not necessary for air embolism to occur. CONCLUSION: Persistent negative pressure in systemic chest veins probably does not occur. The reason for the discrepant foot venous pressure is likely to be a result of dynamic flow and not negative pressure in chest veins. External positive pressure results in slowing of velocity but the transmural pressure remains largely unchanged.


Assuntos
Tontura/fisiopatologia , Embolia Aérea/fisiopatologia , Pé/irrigação sanguínea , Modelos Anatômicos , Modelos Cardiovasculares , Veias/fisiopatologia , Pressão Venosa , Velocidade do Fluxo Sanguíneo , Tontura/patologia , Embolia Aérea/patologia , Humanos , Postura , Pressão , Fluxo Sanguíneo Regional , Veias/patologia , Veia Cava Inferior/fisiopatologia , Veia Cava Superior/fisiologia , Veia Cava Superior/fisiopatologia
18.
J Pediatr ; 167(3): 572-8.e1-2, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26116470

RESUMO

OBJECTIVE: To gather information for a future confirmatory trial of dobutamine (DB) for circulatory impairment (ie, low superior vena cava [SVC] flow). STUDY DESIGN: A total of 127 infants born at < 31 weeks gestational age were serially scanned from birth to 96 hours after birth. The infants were randomly assigned to 2 groups and were treated with DB (stepwise dose increase, 5-10-15-20 µg/kg/min) or placebo if they had an SVC flow < 41 mL/kg/min within the first 24 hours after birth. The primary outcome measures were the achievement and maintenance of an SVC flow ≥ 41 mL/kg/min. Secondary outcome measures were the short-term evolution of clinical and biochemical variables, near-infrared spectroscopy, cranial Doppler ultrasound, and clinical outcomes. RESULTS: SVC flow increased throughout the first 96 hours for the entire cohort. All of the randomized infants (n = 28) except 2 achieved and maintained an SVC flow ≥ 41 mL/kg/min after intervention; however, the infants treated with DB (n = 16) showed a higher heart rate and improved base excess compared with those treated with placebo (n = 12). Low SVC flow was associated with low gestational age (P = .02) and poor condition at birth (P = .02). Low SVC flow significantly increased the risk of severe ischemic events (OR, 13; 95% CI, 2.4-69.2; P < .01). CONCLUSION: This exploratory trial demonstrates a tendency toward improved short-term clinical and biochemical perfusion variable outcomes in infants with low SVC flow treated with DB. TRIAL REGISTRATION: ClinicalTrials.gov (NCT01605279) and the European Clinical Trials Database (EurodraCT 2009-010901-35).


Assuntos
Agonistas de Receptores Adrenérgicos beta 1/uso terapêutico , Cardiotônicos/uso terapêutico , Dobutamina/uso terapêutico , Fluxo Sanguíneo Regional/efeitos dos fármacos , Veia Cava Superior/efeitos dos fármacos , Agonistas de Receptores Adrenérgicos beta 1/administração & dosagem , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Velocidade do Fluxo Sanguíneo/fisiologia , Cardiotônicos/administração & dosagem , Dobutamina/administração & dosagem , Ecocardiografia Doppler , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Projetos Piloto , Espanha , Espectroscopia de Luz Próxima ao Infravermelho , Resultado do Tratamento , Veia Cava Superior/fisiologia
19.
J Vasc Interv Radiol ; 26(2): 252-9.e2, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25645414

RESUMO

PURPOSE: Symmetric-tip dialysis catheters have become alternative devices because of low access recirculation and ease of tip positioning. Flow characteristics of three symmetric catheters were compared based on computational fluid dynamics (CFD) as they relate to catheter function. MATERIALS AND METHODS: In Palindrome, GlidePath, and VectorFlow catheters, a computational fluid dynamics-based approach was used to assess (i) regions of flow separation, which are prone to thrombus development; (ii) shear-induced platelet activation potency; (iii) recirculation; and (iv) venous outflow deflection. A steady-state, laminar flow model simulated catheter tip position within the superior vena cava. Catheter performance was investigated at high hemodialysis flow rate (400 mL/min). Blood was assumed as a Newtonian fluid. RESULTS: Wide regions of flow separation downstream of the Palindrome side slot and close to the distal tip were observed in forward and reversed line configurations. Geometric asymmetry of the distal guide wire aperture of the GlidePath catheter produced the highest levels of inverted velocity flow when run in reversed configuration. The lowest mean shear-induced platelet activation was exhibited by GlidePath and VectorFlow catheters; the Palindrome catheter exhibited 152% higher overall platelet activation potency. All catheters were associated with a recirculation close to zero; the helically contoured lumens of the VectorFlow catheter produced the greatest amount of deflection of venous flow away from the arterial lumen. CONCLUSIONS: The VectorFlow catheter produced less shear-induced platelet activation than the Palindrome catheter and less flow separation than the Palindrome and GlidePath catheters irrespective of line configuration. These findings have potential implications for differences in thrombogenic risk during clinical performance of these catheters.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Cateteres Venosos Centrais , Modelos Cardiovasculares , Ativação Plaquetária/fisiologia , Diálise Renal/instrumentação , Veia Cava Superior/fisiologia , Pressão Sanguínea/fisiologia , Simulação por Computador , Análise de Falha de Equipamento , Humanos , Desenho de Prótese , Reologia/métodos , Resistência ao Cisalhamento/fisiologia
20.
Crit Care ; 19: 68, 2015 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-25887895

RESUMO

INTRODUCTION: Differential hypoxia is a pivotal problem in patients with femoral veno-arterial (VA) extracorporeal membrane oxygenation (ECMO) support. Despite recognition of differential hypoxia and attempts to deliver more oxygenated blood to the upper body, the mechanism of differential hypoxia as well as prevention strategies have not been well investigated. METHODS: We used a sheep model of acute respiratory failure that was supported with femoral VA ECMO from the inferior vena cava to the femoral artery (IVC-FA), ECMO from the superior vena cava to the FA (SVC-FA), ECMO from the IVC to the carotid artery (IVC-CA) and ECMO with an additional return cannula to the internal jugular vein based on the femoral VA ECMO (FA-IJV). Angiography and blood gas analyses were performed. RESULTS: With IVC-FA, blood oxygen saturation (SO2) of the IVC (83.6 ± 0.8%) was higher than that of the SVC (40.3 ± 1.0%). Oxygen-rich blood was drained back to the ECMO circuit and poorly oxygenated blood in the SVC entered the right atrium (RA). SVC-FA achieved oxygen-rich blood return from the IVC to the RA without shifting the arterial cannulation. Subsequently, SO2 of the SVC and the pulmonary artery increased (70.4 ± 1.0% and 73.4 ± 1.1%, respectively). Compared with IVC-FA, a lesser difference in venous oxygen return and attenuated differential hypoxia were observed with IVC-CA and FA-IJV. CONCLUSIONS: Differential venous oxygen return is a key factor in the etiology of differential hypoxia in VA ECMO. With knowledge of this mechanism, we can apply better cannula configurations in clinical practice.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Oxigênio/sangue , Fluxo Sanguíneo Regional/fisiologia , Animais , Aortografia , Artérias Carótidas/fisiologia , Cateterismo/métodos , Modelos Animais de Doenças , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiologia , Insuficiência Respiratória/terapia , Ovinos , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/fisiologia , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA