Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.104
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 222(4): e2330557, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38264999

RESUMO

BACKGROUND. High-frequency jet ventilation (HFJV) facilitates accurate probe placement in percutaneous ablation of lung tumors but may increase risk for adverse events, including systemic air embolism. OBJECTIVE. The purpose of this study was to compare major adverse events and procedural efficiency of percutaneous lung ablation with HFJV under general anesthesia to spontaneous respiration (SR) under moderate sedation. METHODS. This retrospective study included consecutive adults who underwent CT-guided percutaneous cryoablation of one or more lung tumors with HFJV or SR between January 1, 2017, and May 31, 2023. We compared major adverse events (Common Terminology Criteria for Adverse Events grade ≥ 3) within 30 days postprocedure and hospital length of stay (HLOS) of 2 days or more using logistic regression analysis. We compared procedure time, room time, CT guidance acquisition time, CT guidance radiation dose, total radiation dose, and pneumothorax using generalized estimating equations. RESULTS. Overall, 139 patients (85 women, 54 men; median age, 68 years) with 310 lung tumors (82% metastases) underwent 208 cryoablations (HFJV, n = 129; SR, n = 79). HFJV showed greater rates than SR for the treatment of multiple tumors per session (43% vs 19%, respectively; p = .02) and tumors in a nonperipheral location (48% vs 24%, p < .001). Major adverse event rate was 8% for HFJV and 5% for SR (p = .46). No systemic air embolism occurred. HLOS was 2 days or more in 17% of sessions and did not differ significantly between HFJV and SR (p = .64), including after adjusting for probe number per session, chronic obstructive pulmonary disease, and operator experience (p = .53). Ventilation modalities showed no significant difference in procedure time, CT guidance acquisition time, CT guidance radiation dose, or total radiation dose (all p > .05). Room time was longer for HFJV than SR (median, 154 vs 127 minutes, p < .001). For HFJV, the median anesthesia time was 136 minutes. Ventilation modalities did not differ in the frequencies of pneumothorax or pneumothorax requiring chest tube placement (both p > .05). CONCLUSION. HFJV appears to be as safe as SR but had longer room times. HFJV can be used in complex cases without significantly impacting HLOS of 2 days or more, procedure time, or radiation exposure. CLINICAL IMPACT. Selection of the ventilation modality during percutaneous lung ablation should be based on patient characteristics and anticipated procedural requirements as well as operator preference.


Assuntos
Criocirurgia , Ventilação em Jatos de Alta Frequência , Neoplasias Pulmonares , Humanos , Masculino , Feminino , Ventilação em Jatos de Alta Frequência/métodos , Neoplasias Pulmonares/cirurgia , Idoso , Estudos Retrospectivos , Criocirurgia/métodos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Complicações Pós-Operatórias , Radiografia Intervencionista/métodos , Respiração , Idoso de 80 Anos ou mais , Tempo de Internação/estatística & dados numéricos
2.
Curr Opin Pediatr ; 34(2): 165-169, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35034079

RESUMO

PURPOSE OF REVIEW: Ventilation of periviable infants born at 22-23 weeks gestation remains a challenge in neonatology. This review highlights the evidence surrounding the use of first intention high-frequency jet ventilation (HFJV) in infants born near the limits of viability with a review of pulmonary fetal development and a focused overview of HFJV strategies including an in-depth analysis of the management strategies used in the initial randomized trials. RECENT FINDINGS: A paucity of recent trials exists, with no randomized control trials assessing the use of first intention HFJV performed in the last 25 years. A retrospective observational cohort trial of the use of HFJV for infants born at less than 750 g has been recently published demonstrating the efficacy of HFJV for this population even with 2.0-mm endotracheal tubes. SUMMARY: The lack of recent randomized trials contributes to the controversy surrounding the use of first intention HFJV. Although new research is needed in the area, this review includes the ventilation strategy of an experienced center with a focus on the use of first intention HFJV for the care of premature infants born less than 24 weeks gestation.


Assuntos
Ventilação em Jatos de Alta Frequência , Síndrome do Desconforto Respiratório do Recém-Nascido , Humanos , Lactente , Recém-Nascido , Intenção , Estudos Observacionais como Assunto , Respiração Artificial , Estudos Retrospectivos
3.
Am J Otolaryngol ; 43(1): 103187, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34536915

RESUMO

OBJECTIVE: Laryngeal transoral surgery classically requires a neuromuscular block (NMB) to facilitate tracheal intubation and to improve surgical conditions. However, the short duration of most procedures and the potential complications of residual NMB lead to consider a no block approach. The hypothesis that intravenous anesthesia (remifentanil and propofol infusions) without NMB but including glottis topical lidocaine anesthesia would allow clinically acceptable laryngeal exposure and good surgical conditions was tested in the specific context of procedures undergone with High Frequency Jet Ventilation (HFJV). STUDY DESIGN: A prospective randomized clinical comparison. METHODS: 66 consenting patients were planned to receive 0.6 mg·kg-1 rocuronium or saline at random. The outcome measurements included the time and conditions to complete suspended laryngoscopy, and the surgical conditions rated by the surgeon. Any vocal cord movement or coughing was recorded. Data were compared using a Wilcoxon rank-sum test for numerical variables and chi-square test for categorical ones. Treatment failure was defined as an impossible laryngoscopy or a grade 4 surgical field occurring at any time during surgery and was compared to its null theoretical value by a general z-test. An interim analysis after completion of 50% patients was performed using Pocock boundaries at 0.0294 significance levels. RESULTS: A significant failure rate occurred in the non paralysed group (27%, p < 0.001). No coughing and no vocal cords movement occurred in the NMB group. Poorer surgical conditions were obtained without NMB (p = 0.011). CONCLUSION: Inducing a deep NMB ensured improved conditions during direct laryngeal microsurgery with HFJV.


Assuntos
Anestesia Geral/métodos , Anestesia Intravenosa/métodos , Ventilação em Jatos de Alta Frequência/métodos , Laringoscopia/métodos , Laringe/cirurgia , Lidocaína , Microcirurgia/métodos , Bloqueio Neuromuscular/métodos , Adulto , Feminino , Humanos , Intubação Intratraqueal , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Rocurônio , Resultado do Tratamento , Adulto Jovem
4.
Acta Anaesthesiol Scand ; 65(9): 1248-1253, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34028010

RESUMO

BACKGROUND: High-frequency jet ventilation is necessary to reduce organ movements during stereotactic liver ablation. However, post-operative hypertensive episodes especially following irreversible electroporation ablation compared with microwave ablation initiated this study. The hypothesis was that hypertensive episodes could be related to ventilation or ablation method. METHODS: The aim of this retrospective study was to assess the proportion of patients with hypertensive events during recovery following liver ablation under general anaesthesia and to analyse the relation to ventilation and ablation technique. A medical chart review of 134 patients undergoing either high-frequency jet ventilation and microwave ablation (n = 45), high-frequency jet ventilation and irreversible electroporation (n = 44), or conventional ventilation and microwave ablation (n = 45) was performed. The proportion of patients with at least one episode of systolic arterial pressure 140-160, 160-180 or >180 mmHg during early recovery and the impact of ventilation method was studied. RESULTS: Out of 134 patients, 100, 75 and 34 patients had at least one episode of mild, moderate and severe hypertension. Microwave ablation, as well as high frequency jet ventilation, was associated with an increased odds ratio for post-operative hypertension. The proportion of patients with at least one severe hypertensive event was 18/45, 9/44 and 7/45, respectively. CONCLUSION: Both ventilation and ablation technique had an impact on post-operative hypertensive episodes. The microwave ablation/high-frequency jet ventilation combination increased the risk as compared with irreversible electroporation/high-frequency jet ventilation and microwave ablation/conventional ventilation.


Assuntos
Ventilação em Jatos de Alta Frequência , Hipertensão , Neoplasias Hepáticas , Humanos , Hipertensão/epidemiologia , Neoplasias Hepáticas/cirurgia , Estudos Retrospectivos
5.
BMC Anesthesiol ; 21(1): 65, 2021 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-33653271

RESUMO

BACKGROUND: High frequency jet ventilation (HFJV) is an open ventilating technique to maintain ventilation for emergency or difficult airway. However, whether jet ventilation or conventional oxygen therapy (COT) is more effective and safe in maintaining adequate oxygenation, is unclear among patients with airway stenosis during bronchoscopic intervention (BI) under deep sedation. METHODS: A prospective randomized cohort study was conducted to compare COT (high flow oxygen) with normal frequency jet ventilation (NFJV) and HFJV in oxygen supplementation during BI under deep sedation from March 2020 to August 2020. Patients receiving BI under deep sedation were randomly divided into 3 parallel groups of 50 patients each: the COT group (fractional inspired oxygen (FiO2) of 1.0, 12 L/min), the NFJV group (FiO2 of 1.0, driving pressure of 0.1 MPa, and respiratory rate (RR) 15 bpm) and the HFJV Group (FiO2 of 1.0, driving pressure of 0.1 MPa, and RR of 1200 bpm). Pulse oxygen saturation (SpO2), mean arterial blood pressure and heart rate were recorded during the whole procedure. Arterial blood gas was examined and recorded 15 min after the procedure was initiated. The procedure duration, dose of anesthetics, and adverse events during BI in the three groups were also recorded. RESULTS: A total of 161 patients were enrolled, with 11 patients excluded. The clinical characteristics were similar among the three groups. PaO2 of the COT and NFJV groups was significantly lower than that of the HFJV group (P < 0.001). PaO2 was significantly correlated with ventilation mode (P < 0.001), body mass index (BMI) (P = 0.019) and procedure duration (P = 0.001). Multiple linear regression showed that only BMI and procedure duration were independent influencing factors of arterial blood gas PaO2 (P = 0.040 and P = 0.002, respectively). The location of airway lesions and the severity of airway stenosis were not statistically correlated with PaCO2 and PaO2. CONCLUSIONS: HFJV could effectively and safely improve intra-operative PaO2 among patients with airway stenosis during BI in deep sedation, and it did not increase the intra-operative PaCO2 and the risk of hypercapnia. PaO2 was correlated with ventilation mode, BMI and procedure duration. Only BMI and procedure duration were independent influencing factors of arterial blood gas PaO2. PaCO2 was not correlated with any preoperative factor. TRIAL REGISTRATION: Chinese Clinical Trial Registry. Registration number, ChiCTR2000031110 , registered on March 22, 2020.


Assuntos
Broncoscopia/métodos , Sedação Profunda/métodos , Ventilação em Jatos de Alta Frequência/instrumentação , Ventilação em Jatos de Alta Frequência/métodos , Oxigenoterapia/métodos , Saturação de Oxigênio/fisiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Máscaras , Pessoa de Meia-Idade , Estudos Prospectivos
6.
Eur Arch Otorhinolaryngol ; 278(11): 4403-4409, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34264375

RESUMO

PURPOSE: To investigate how variations in positioning of laryngoscope and location of jet cannula on the laryngoscope body influence tracheal airflow during simulated high-pressure source supraglottic (HPSV) jet ventilation laryngoscopy using an anatomical model. METHODS: A Broncho Boy Bronchoscopy model was modified to allow recording of tracheal airflow. A laryngoscope was suspended and positioned to simulate laryngoscopy. HPSV was delivered by a jet cannula attached to the body of the laryngoscope. Different combinations of laryngoscope angulation and cannula attachment were used and air flow recorded for each combination. Statistical analysis assessed the variations in flow. RESULTS: Significant statistical differences in flow effect (P < 0.05) were shown, indicating that laryngoscope position and attachment of jet cannula have a significant effect on tracheal airflow. Highest flows were achieved by anterior positioning of laryngoscope combined with anterolateral attachment of cannula (> 1 L/s) compared to downward or either side (< 0.6 L/s). CONCLUSION: Significant differences in tracheal airflow arise from different positions of both laryngoscope and jet cannula with supraglottic HPSV. Optimal locations for both are apparent and collaborative interaction with anaesthetist emphasised. The experimental setup could be a potential simulation tool.


Assuntos
Ventilação em Jatos de Alta Frequência , Laringoscópios , Cânula , Humanos , Intubação Intratraqueal , Laringoscopia , Masculino , Respiração , Traqueia
7.
J Cardiovasc Electrophysiol ; 31(7): 1678-1686, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32314841

RESUMO

INTRODUCTION: Catheter stability during atrial fibrillation ablation is associated with higher ablation success rates. Rapid cardiac pacing and high-frequency jet ventilation (HFJV) independently improve catheter stability. Simultaneous modulation of cardiac and respiratory motion has not been previously studied. The objective of this study was to determine the effect of simultaneous heart rate and respiratory rate modulation on catheter stability. METHODS: Forty patients undergoing paroxysmal atrial fibrillation ablation received ablation lesions at 15 prespecified locations (12 left atria, 3 right atria). Patients were randomly assigned to undergo rapid atrial pacing for either the first or the second half of each lesion. Within each group, half of the patients received HFJV and the other half standard ventilation. Contact force and ablation data for all lesions were compared among the study groups. Standard deviation of contact force was the primary endpoint defined to examine contact force variability. RESULTS: Lesions with no pacing and standard ventilation had the greatest contact force standard deviation (5.86 ± 3.08 g), compared to lesions with pacing and standard ventilation (5.45 ± 3.28 g; P < .01) or to lesions with no pacing and HFJV (4.92 ± 3.00 g; P < .01). Lesions with both pacing and HFJV had the greatest reduction in contact force standard deviation (4.35 ± 2.81 g; P < .01), confirming an additive benefit of each maneuver. Pacing and HFJV together was also associated with a reduction in the proportion of lesions with excessive maximum contact force (P < .001). DISCUSSION: Rapid pacing and HFJV additively improve catheter stability. Simultaneous pacing with HFJV further improves catheter stability over pacing or HFJV alone to optimize ablation lesions.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ventilação em Jatos de Alta Frequência , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Catéteres , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos
8.
Minerva Pediatr ; 72(1): 60-64, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29479941

RESUMO

Infants born prematurely require external respiratory support device like ventilation for the purpose of life saving. However, these ventilation machines have complications that sometimes unfortunately result in morbidity. New ventilation techniques have been developed to prevent morbidity, but have yet to be fully evaluated. The present review article would discuss current aspects of this life saving gear especially for pediatric patients in clinical setting. Besides basic ventilation apparatus, advancements in the filed like proportional assist ventilation, volume targeted ventilation would be discussed.


Assuntos
Recém-Nascido de Baixo Peso , Respiração Artificial/efeitos adversos , Ventiladores Mecânicos/efeitos adversos , Displasia Broncopulmonar/etiologia , Diafragma , Ventilação em Jatos de Alta Frequência/instrumentação , Ventilação de Alta Frequência/efeitos adversos , Ventilação de Alta Frequência/instrumentação , Ventilação de Alta Frequência/métodos , Humanos , Recém-Nascido , Suporte Ventilatório Interativo/métodos , Pneumotórax/etiologia , Enfisema Pulmonar/etiologia , Transtornos Respiratórios/etiologia , Respiração Artificial/instrumentação , Respiração Artificial/métodos , Respiração Artificial/tendências
9.
Liver Int ; 39(10): 1975-1985, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31276296

RESUMO

BACKGROUND & AIMS: Ablation plays an important role in the treatment of hepatocellular carcinoma. Because image-guided navigation technology has recently entered the clinical setting, we aimed to analyse its safety, therapeutic and procedural efficiency. METHODS: Retrospective analysis of patients treated with stereotactic image-guided microwave ablation (SMWA) between January 2015 and December 2017. Interventions were performed using computertomography-guidance with needle trajectory, ablation planning and automatic single-marker patient registration. Needle placement and ablation coverage was controlled by image fusion under general anaesthesia with jet-ventilation. RESULTS: In total 174 ablations were performed in 88 patients during 119 interventions. Mean age was 66 (46-84) years, 74 (84.1%) were men and 74% were Child Pugh Class A. Median tumour size was 16 (4-45) mm, 62.2% were BCLC A. Median lateral and longitudinal error of needle placement were 3.2 (0.2-14.1) and 1.6 (0-15.8) mm. Median one tumour (1-4) was ablated per session. One patient developed a Dindo IIIb (0.8%) complication, six minor complications. After re-ablation of 12 lesions, an efficacy rate of 96.3% was achieved. Local tumour progression was 6.3% (11/174). Close proximity to major vessels was significantly correlated with local tumour progression (P < .05). Median overall follow-up was 17.5 months after intervention and 24 months after initial diagnosis. BCLC stage, child class and previous treatment were significantly correlated with overall survival (P < .05). CONCLUSION: Stereotactic image-guided microwave ablation is a safe and efficient treatment for HCC offering a curative treatment approach in general and in particular for lesions not detectable on conventional imaging or untreatable because of difficult anatomic locations.


Assuntos
Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/métodos , Neoplasias Hepáticas/cirurgia , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/mortalidade , Feminino , Hepatectomia/métodos , Ventilação em Jatos de Alta Frequência/métodos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/mortalidade , Masculino , Micro-Ondas/uso terapêutico , Pessoa de Meia-Idade , Segurança do Paciente , Estudos Retrospectivos , Técnicas Estereotáxicas , Análise de Sobrevida , Suíça , Resultado do Tratamento
11.
Int J Hyperthermia ; 36(1): 1051-1057, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31621440

RESUMO

Objectives: To report the feasibility and efficacy of percutaneous ablation of small hepatic malignant tumors that are invisible on ultrasound and inaccessible using in-plane CT guidance, using a combination of high-frequency jet-ventilation (HFJV) and electromagnetic (EM) needle tracking. Methods: This study reviewed 27 percutaneous ablations of small hepatic tumors (<2 cm) performed using EM navigation-based probe placement and HFJV. All lesions were invisible on ultrasound and difficult to reach on CT requiring a double-oblique approach. The primary outcome was technical efficacy, defined as complete lesion coverage, and evaluated on contrast enhanced MRI after 3 and 6 months. Needle placement accuracy, the number of control CT acquisitions, procedure time, complications and radiation doses were assessed. Results: Twenty-one patients with 27 treated lesions (14 hepatocellular carcinomas and 13 metastases) were included in this study. Mean tumor size was 12 ± 5.7 mm. Thirty-three percent of the lesions were located on the hepatic dome. Complete ablation was obtained in 100% at the 3- and 6-month MRI follow-up. The ablation probe was correctly placed on the first pass in 96%, with a mean path-to-tumor angle of 7 ± 4 degrees and a mean tip-to-tumor distance of 22 ± 19mm. A readjustment for additional overlapping application resulted in complete treatment in 4 patients. Needle placement took a mean 23 ± 12 min with mean radiation doses of 558 mGy*cm. No major complications were reported. Conclusion: Percutaneous liver ablation of lesions that cannot be seen on US and requiring out-of-plane CT access can be successfully and safely treated using electromagnetic-based navigation and jet-ventilation.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Fenômenos Eletromagnéticos , Ventilação em Jatos de Alta Frequência/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/cirurgia , Feminino , Humanos , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
12.
BMC Anesthesiol ; 19(1): 151, 2019 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-31409366

RESUMO

BACKGROUND: Supraglottic jet oxygenation and ventilation (SJOV) can effectively maintain adequate oxygenation in patients with respiratory depression, even in apnea patients. However, there have been no randomized controlled clinical trials of SJOV in obese patients. This study investigated the efficacy and safety of SJOV using WEI Nasal Jet tube (WNJ) for obese patients who underwent hysteroscopy under intravenous anesthesia without endotracheal intubation. METHODS: A single-center, prospective, randomized controlled study was conducted. The obese patients receiving hysteroscopy under intravenous anesthesia were randomly divided into three groups: Control group maintaining oxygen supply via face masks (100% oxygen, flow at 6 L/min), the WNJ Oxygen Group with WNJ (100% oxygen, flow: 6 L/min) and the WNJ SJOV Group with SJOV via WNJ [Jet ventilator working parameters:100% oxygen supply, driving pressure (DP) 0.1 MPa, respiratory rate; (RR): 15 bpm, I/E; ratio 1:1.5]. SpO2, PETCO2, BP, HR, ECG and BIS were continuously monitored during anesthesia. Two-Diameter Method was deployed to measure cross sectional area of the gastric antrum (CSA-GA) by ultrasound before and after SJOV in the WNJ SJOV Group. Episodes of SpO2 less than 95%, PETCO2 less than 10 mmHg, depth of WNJ placement and measured CSA-GA before and after jet ventilation in the WNJ SJOV Group during the operation were recorded. The other adverse events were collected as well. RESULTS: A total of 102 patients were enrolled, with two patients excluded. Demographic characteristics were similar among the three groups. Compared with the Control Group, the incidence of PETCO2 < 10 mmHg, SpO2 < 95% in the WNJ SJOV group dropped from 36 to 9% (P = 0.009),from 33 to 6% (P = 0.006) respectively,and the application rate of jaw-lift decreased from 33 to 3% (P = 0.001), and the total percentage of adverse events decreased from 36 to 12% (P = 0.004). Compared with the WNJ Oxygen Group, the use of SJOV via WNJ significantly decreased episodes of SpO2 < 95% from 27 to 6% (P = 0.023), PETCO2 < 10 mmHg from 33 to 9% (P = 0.017), respectively. Depth of WNJ placement was about 12.34 cm in WNJ SJOV Group. There was no significantly difference of CSA-GA before and after SJOV in the WNJ SJOV Group (P = 0.234). There were no obvious cases of nasal bleeding in all the three groups. CONCLUSIONS: SJOV can effectively and safely maintain adequate oxygenation in obese patients under intravenous anesthesia without intubation during hysteroscopy. This efficient oxygenation may be mainly attributed to supplies of high concentration oxygenation to the supraglottic area, and the high pressure jet pulse providing effective ventilation. Although the nasal airway tube supporting collapsed airway by WNJ also plays a role. SJOV doesn't seem to increase gastric distension and the risk of aspiration. SJOV can improve the safety of surgery by reducing the incidence of the intraoperative involuntary limbs swing, hip twist and cough. TRIAL REGISTRATION: Chinese Clinical Trial Registry. Registration number, ChiCTR1800017028, registered on July 9, 2018.


Assuntos
Anestesia Intravenosa/métodos , Ventilação em Jatos de Alta Frequência/métodos , Histeroscopia/métodos , Obesidade/terapia , Cuidados Pré-Operatórios/métodos , Adolescente , Adulto , Idoso , Feminino , Ventilação em Jatos de Alta Frequência/efeitos adversos , Humanos , Pessoa de Meia-Idade , Adulto Jovem
13.
Paediatr Anaesth ; 29(8): 799-807, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31233654

RESUMO

BACKGROUND: Self-made Y-connector jet-oxygenation devices with wide-bore expiratory port have been described but not evaluated in infant models. Little is known about the effect of oxygen flow rates on jet oxygenation via transtracheal cannula. AIMS: The aim of this study was to compare two self-made Y-connector jet-oxygenation devices against the ENK oxygen flow modulator™, and the effects of three different oxygen flow rates based on body weight, in both unobstructed and obstructed airways, on the time to re-oxygenate in a rabbit infant model. The aim was also to assess the effectiveness of an oxygen flow rate of 1 L/min, for re-oxygenation using ENK oxygen flow modulator™. METHODS: Nine rabbits were grouped in threes: Group 1 had a Y-connector attached to an intravenous infusion tubing, Group 2 the same Y-connector attached to a perfusion oxygenator tubing and Group 3, ENK oxygen flow modulator™. From oxygen saturations of 75%, the rabbits were jet oxygenated using their assigned device for 10 minutes at each flow rate of 1 L/kg/min, 1.5 L/kg/min and 2 L/kg/min with their airways unobstructed and later, obstructed. Group 3 had additional experiments involving an absolute oxygen flow rate of 1 L/min. RESULTS: All devices resulted in rapid re-oxygenation within 40 seconds at flow rates of 1 L/kg/min. Oxygen flow rates beyond 1 L/kg/min in obstructed airways resulted in high airway pressures. All rabbits in Group 3 with obstructed airways died from barotrauma when jet oxygenated at a flow rate of 1.5 L/kg/min. When an oxygen flow rate of 1 L/min was used in Group 3, there was a failure to re-oxygenate to SpO2 90% within 120 seconds in some rabbits. CONCLUSION: Our animal model results suggest that self-made Y-connector jet-oxygenation devices with wide-bore expiratory port are efficacious and perhaps safer than ENK oxygen flow modulator™ in obstructed airways, and jet oxygenation with minimal oxygen flow rates starting at 1 L/kg/min or (age [years] + 4) L/min, whichever lower, should be considered.


Assuntos
Ventilação em Jatos de Alta Frequência/instrumentação , Intubação Intratraqueal/métodos , Respiração Artificial/métodos , Obstrução das Vias Respiratórias , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Coelhos
14.
BMC Anesthesiol ; 18(1): 101, 2018 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-30064377

RESUMO

BACKGROUND: Electrical impedance tomography (EIT) is a tool to monitor regional ventilation distribution in patient's lungs under general anesthesia. The objective of this study was to assess the regional ventilation distribution using different driving pressures (DP) during high frequency jet ventilation (HFJV). METHODS: Prospective, observational, cross-over study. Patients undergoing rigid bronchoscopy were ventilated HFJV with DP 1.5 and 2.5 atm. Hemodynamic and ventilation parameters, as well as ventilation in different regions of the lungs in percentage of total ventilation, assessed by EIT, were recorded. RESULTS: Thirty-six patients scheduled for elective rigid bronchoscopy. The final analysis included thirty patients. There was no significant difference in systolic, diastolic and mean arterial blood pressure, heart rate, and peripheral saturation between the two groups. Peak inspiratory pressure, mean inspiratory pressure, tidal volume, and minute volume significantly increased in the second, compared to the first intervention group. Furthermore, there were no statistically significant differences between each time profiles in all ROI regions in EIT. CONCLUSIONS: In our study intraoperative EIT was an effective method of functional monitoring of the lungs during HFJV for rigid bronchoscopy procedure. Lower driving pressure was as effective in providing sufficient ventilation distribution through the lungs as the higher driving pressure but characterized by lower airway pressure. TRIAL REGISTRATION: The study was registered on ClinicalTrials.gov under no. NCT02997072 .


Assuntos
Ventilação em Jatos de Alta Frequência/métodos , Pulmão/fisiologia , Ventilação Pulmonar/fisiologia , Broncoscopia/métodos , Estudos Cross-Over , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Pressão , Estudos Prospectivos , Tomografia/métodos
15.
Zhonghua Yi Xue Za Zhi ; 98(24): 1941-1944, 2018 Jun 26.
Artigo em Zh | MEDLINE | ID: mdl-29996287

RESUMO

Objective: To analyze the clinical applications of high frequency jet ventilation(HFJV) in cryotherapy of the trachea and bronchial neoplasms by the rigid bronchoscope. Methods: The clinical data of 35 patients who were treated with tracheal neoplasms cryotherapy by the rigid bronchoscopy under HFJV were collected in China-Japan Friendship Hospital from August 2008 to February 2015.Under general anesthesia, HFJV was used in all patients. The mean arterial pressure (MAP), heart rates (HR), pulse oxygen saturation (SpO(2)), results of arterial blood gas analysis and the incidence of complications during the procedure were recorded. Results: In the 35 patients, one case had multiple operations experience, he had an airway spasm after HFJV 40 min during his second operation, and severe hypoxemia after HFJV 5 min during his third operation, endotracheal intubation was performed immediately. The patient has a serious accumulation of carbon dioxide (CO(2)) whose partial pressure of carbon dioxide in the artery (PaCO(2)) was up to 71 mmHg(1 mmHg=0.133 kPa). Other patients had stable hemodynamics and no severe CO(2) accumulation. Conclusion: High frequency jet ventilation can provide satisfactory ventilation effect in cryotherapy of the trachea and bronchial end-stage neoplasms by the rigid bronchoscope.


Assuntos
Broncoscopia , Carcinoma Broncogênico/cirurgia , Ventilação em Jatos de Alta Frequência , Neoplasias da Traqueia/cirurgia , Anestesia Geral , Gasometria , Dióxido de Carbono , China , Criocirurgia , Crioterapia , Frequência Cardíaca , Hemodinâmica , Humanos , Intubação Intratraqueal , Masculino , Traqueia
16.
Kyobu Geka ; 71(5): 392-395, 2018 May.
Artigo em Japonês | MEDLINE | ID: mdl-29755094

RESUMO

An 81-year-old woman with acute respiratory distress was referred to our hospital. Computed tomography showed a large mass in the upper mediastinum with severe tracheal stenosis. Endotracheal intubation was performed under the preparation of extracorporeal membrane oxygenation and high-frequency jet ventilation, and the tumor was completely removed. The pathologic diagnosis was a goiter. Post-operatively, respiratory distress disappeared. No tumor recurrences have been noted for more than 2 years after surgery.


Assuntos
Bócio Subesternal/cirurgia , Insuficiência Respiratória/terapia , Estenose Traqueal/cirurgia , Idoso de 80 Anos ou mais , Emergências , Oxigenação por Membrana Extracorpórea , Feminino , Bócio Subesternal/complicações , Bócio Subesternal/diagnóstico por imagem , Ventilação em Jatos de Alta Frequência , Humanos , Intubação Intratraqueal , Insuficiência Respiratória/etiologia , Tomografia Computadorizada por Raios X , Estenose Traqueal/diagnóstico por imagem , Estenose Traqueal/etiologia
17.
AJR Am J Roentgenol ; 208(1): 193-200, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27762601

RESUMO

OBJECTIVE: The purpose of the present study is to evaluate the accuracy and safety of antenna placement performed with the use of a CT-guided stereotactic navigation system for percutaneous ablation of liver tumors and to assess the safety of high-frequency jet ventilation for target motion control. MATERIALS AND METHODS: Twenty consecutive patients with malignant liver lesions for which surgical resection was contraindicated or that were not readily visible on ultrasound or not accessible by ultrasound guidance were included in the study. Patients were treated with percutaneous microwave ablation performed using a CT-guided stereotactic navigation system. High-frequency jet ventilation was used to reduce liver motion during all interventions. The accuracy of antenna placement, the number of needle readjustments required, overall safety, and the radiation doses were assessed. RESULTS: Microwave ablation was completed for 20 patients (28 lesions). Performance data could be evaluated for 17 patients with 25 lesions (mean [± SD] lesion diameter, 14.9 ± 5.9 mm; mean lesion location depth, 87.5 ± 27.3 mm). The antennae were placed with a mean lateral error of 4.0 ± 2.5 mm, a depth error of 3.4 ± 3.2 mm, and a total error of 5.8 ± 3.2 mm in relation to the intended target. The median number of antenna readjustments required was zero (range, 0-1 adjustment). No major complications were related to either the procedure or the use of high-frequency jet ventilation. The mean total patient radiation dose was 957.5 ± 556.5 mGy × cm, but medical personnel were not exposed to irradiation. CONCLUSION: Percutaneous microwave ablation performed with CT-guided stereotactic navigation provides sufficient accuracy and requires almost no repositioning of the needle. Therefore, it is technically feasible and applicable for safe treatments.


Assuntos
Ablação por Cateter/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Técnicas Estereotáxicas , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos de Viabilidade , Feminino , Hepatectomia/métodos , Ventilação em Jatos de Alta Frequência/métodos , Humanos , Masculino , Micro-Ondas/uso terapêutico , Segurança do Paciente , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Intensificação de Imagem Radiográfica/métodos , Resultado do Tratamento
18.
Br J Anaesth ; 119(1): 158-166, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28974061

RESUMO

BACKGROUND: Hypoventilation is the main reason for hypoxia during upper gastrointestinal endoscopy procedures with sedation. The key to preventing hypoxia is to maintain normal ventilation during the procedure. We introduced supraglottic jet oxygenation and ventilation (SJOV) through a new Wei nasal jet tube (WNJ) to reduce the incidence of hypoxia in patients sedated with propofol during upper gastrointestinal endoscopy procedures. METHODS: In a multicentre, prospective randomized single-blinded study, 1781 outpatients undergoing routine upper gastrointestinal endoscopy who were sedated with propofol by an anaesthetist were randomized into the following three groups: the supplementary oxygen via nasal cannula group [nasal cannula oxygen: O 2 (2 litres min -1 ) was administered via a nasal cannula]; the supplementary oxygen via WNJ group [WNJ oxygen: O 2 (2 litres min -1 ) was administered through a WNJ]; and the SJOV via WNJ group (WNJ SJOV: SJOV was administered via WNJ) at three centres from March 2015 to July 2016. The primary outcome of interest was the incidence of hypoxia (peripheral oxygen saturation of 75-89%). Other adverse events were also recorded. RESULTS: Supraglottic jet oxygenation and ventilation decreased the incidence of hypoxia from 9 to 3% ( P <0.0001). No severe hypoxia occurred in the WNJ SJOV group, one instance occurred in the WNJ oxygen group, and two instances were observed in the nasal cannula oxygen supply control group. Supraglottic jet oxygenation and ventilation-related minor adverse events increased significantly within 1 min after the procedure but decreased 30 min later. CONCLUSIONS: The use of SJOV during upper gastrointestinal endoscopy for patients who are sedated with propofol reduces the incidence of hypoxia, with minor and tolerable adverse events. Supraglottic jet oxygenation and ventilation has a favourable risk-to-benefit ratio and may improve patient safety. CLINICAL TRIAL REGISTRATION: NCT02436018.


Assuntos
Endoscopia Gastrointestinal , Ventilação em Jatos de Alta Frequência/métodos , Hipnóticos e Sedativos/farmacologia , Oxigênio/metabolismo , Propofol/farmacologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Ventilação em Jatos de Alta Frequência/instrumentação , Humanos , Hipóxia/prevenção & controle , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Adulto Jovem
19.
Acta Anaesthesiol Scand ; 61(9): 1066-1074, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28804874

RESUMO

BACKGROUND: High frequency jet ventilation (HFJV) is a method of ventilation that has gained renewed interest over the recent years as it can reduce organ movement to near static conditions, thus enhancing surgical precision in minimal invasive procedures, for example, ablation procedures for atrial fibrillation and solid organ tumours. The aim of this review was to create a summary of the current evidence concerning the clinical use of HFJV for ablative procedures. METHOD: PubMed was searched for the key words high frequency ventilation and ablation January 1990-December 2016. RESULT: The search initially identified 34 papers, 14 met the inclusion criteria. Articles in other languages than English (n = 1), comments regarding other articles (n = 4) and articles that did not include HFJV or ablative procedures (n = 15) were excluded. Two articles were added from references in papers included from the primary search. Sixteen studies were finally included in the review; four updates/reviews and 12 papers with results from studies of HFJV on humans, with a total of 889 patients; 498 patients ventilated with HFJV and 391 controls. There were no randomised studies. The overall scientific quality of the studies was low. CONCLUSION: There is a lack of well-designed studies evaluating HFJV during ablation procedures. The available information, while sparse, supports the effect of less tissue movement, resulting in better surgical precision and outcome; such as shorter procedural time, fewer shock waves (ESWL) and less recurrence of atrial fibrillation. Randomised controlled studies are needed in this promising area of research to prove its superiority to standard ventilation.


Assuntos
Técnicas de Ablação/métodos , Ventilação em Jatos de Alta Frequência/métodos , Humanos , Cuidados Intraoperatórios , Movimento , PubMed
20.
Laryngorhinootologie ; 96(9): 597-606, 2017 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-28605818

RESUMO

Introduction Voice disorders caused by pseudotumors of the vocal folds or paralysis of the vocal folds with incomplete glottis closure frequently require phonomicrosurgery. These interventions were analyzed with regard to quality of voice after surgery and safety of the intervention. Methods Retrospective analysis of 400 consecutive phonomicrosurgery interventions. The following parameters were collected: distribution of pathologies of the vocal folds, rating of the voice quality by both the surgeon (RBH-system) and patient and videolaryngstroboscopy six weeks after the intervention compared to the state prior to surgery, complications and results of histological examination. Results In our collective vocal fold polyps (36 %), cysts (12 %) and paralysis (10 %) dominated. After the intervention the quality of voice improved in 90 % of all cases. In 14 % voice therapy was needed postoperatively because of hyperfunction.After vocal fold augmentation one patient developed an edema of the larynx and another patient a temporary paralysis of the vocal fold of the opposite side. The histological examination showed as incidental findings a malignant osteoclastic giant cell tumor, a granular cell tumor and a carcinoma in situ of the vocal fold requiring further surgery and follow up. Discussion Phonomicrosurgery is a safe and effective therapy. The histological examination is also useful in patients with macroscopically non suspicious lesions to recognize rare or malignant tumor entities. Patient observation with early detection as well as therapy of complications like edema of the larynx or vocal fold paralysis is recommended.


Assuntos
Laringoscopia/métodos , Microcirurgia/métodos , Distúrbios da Voz/cirurgia , Adolescente , Adulto , Assistência ao Convalescente , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Granuloma Laríngeo/cirurgia , Granuloma de Células Plasmáticas/cirurgia , Ventilação em Jatos de Alta Frequência , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Paralisia das Pregas Vocais/cirurgia , Prega Vocal/cirurgia , Qualidade da Voz , Treinamento da Voz , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA