Your browser doesn't support javascript.
loading
Improvements of data quality of the LHD Thomson scattering diagnostics in high-temperature plasma experiments.
Yamada, I; Narihara, K; Funaba, H; Hayashi, H; Kohmoto, T; Takahashi, H; Shimozuma, T; Kubo, S; Yoshimura, Y; Igami, H; Tamura, N.
Afiliación
  • Yamada I; National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292, Japan. yamadai@LHD.nifs.ac.jp
Rev Sci Instrum ; 81(10): 10D522, 2010 Oct.
Article en En | MEDLINE | ID: mdl-21033877
ABSTRACT
In Large Helical Device (LHD) experiments, an electron temperature (T(e)) more than 15 keV has been observed by the yttrium-aluminum-garnet (YAG) laser Thomson scattering diagnostic. Since the LHD Thomson scattering system has been optimized for the temperature region, 50 eV≤T(e)≤10 keV, the data quality becomes worse in the higher T(e) region exceeding 10 keV. In order to accurately determine T(e) in the LHD high-T(e) experiments, we tried to increase the laser pulse energy by simultaneously firing three lasers. The technique enables us to decrease the uncertainties in the measured T(e). Another signal accumulation method was also tested. In addition, we estimated the influence of high-energy electrons on T(e) obtained by the LHD Thomson scattering system.

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Año: 2010 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Año: 2010 Tipo del documento: Article País de afiliación: Japón