Your browser doesn't support javascript.
loading
Bubble stream reveals functionality of the right-to-left shunt: detection of a potential source for air embolism.
Parlak, Ismail Burak; Egi, Salih Murat; Ademoglu, Ahmet; Germonpré, Peter; Esen, Ozlem Batukan; Marroni, Alessandro; Balestra, Costantino.
Afiliación
  • Parlak IB; Institute of Biomedical Engineering, Bogaziçi University, Istanbul, Turkey; Department of Computer Engineering, Galatasaray University, Istanbul, Turkey. Electronic address: bparlak@gsu.edu.tr.
  • Egi SM; Department of Computer Engineering, Galatasaray University, Istanbul, Turkey; Divers Alert Network Europe- Research Committee, B-1600 Brussels, Belgium.
  • Ademoglu A; Institute of Biomedical Engineering, Bogaziçi University, Istanbul, Turkey.
  • Germonpré P; Divers Alert Network Europe- Research Committee, B-1600 Brussels, Belgium; Centre for Hyperbaric Oxygen Therapy, Military Hospital, B-1120 Brussels, Belgium.
  • Esen OB; Istanbul Memorial Hospital, Istanbul, Turkey.
  • Marroni A; Divers Alert Network Europe- Research Committee, B-1600 Brussels, Belgium.
  • Balestra C; Divers Alert Network Europe- Research Committee, B-1600 Brussels, Belgium; Environmental & Occupational Physiology Laboratory, Haute Ecole Paul Henri Spaak, Brussels, Belgium.
Ultrasound Med Biol ; 40(2): 330-40, 2014 Feb.
Article en En | MEDLINE | ID: mdl-24262055
ABSTRACT
The existence of a right-to-left shunt may increase the likelihood of micro-embolism by allowing a flux of bubbles under hyperbaric conditions. The aim of the study was to measure the relationship between these shunts and bubbles in 10 consecutive subjects using trans-thoracic and trans-esophageal echocardiography. In video frames, all cardiac chambers were segmented and bubbles were analyzed by our proposed method and two other methods. The relationship with bubbles and shunts was divided into three classes no bubbles, 1-20 bubbles, >20 bubbles and measured over 2160 frames. Our sensitivity was 100% and our specificity was between 90.1% and 96.4%. There were 4.32-23.78 bubbles/frame in the left atrium according to our method. After the automatic analysis, shunts were graded double-blinded by two cardiologists. Consequently, we noted that aperture size does not necessarily reflect how active the right-to-left shunt is. Instead, our proposed decay curves constitute a better tool for determining functionality.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Ecocardiografía / Interpretación de Imagen Asistida por Computador / Microburbujas / Embolia Aérea / Foramen Oval Permeable Tipo de estudio: Diagnostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Ultrasound Med Biol Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Ecocardiografía / Interpretación de Imagen Asistida por Computador / Microburbujas / Embolia Aérea / Foramen Oval Permeable Tipo de estudio: Diagnostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Ultrasound Med Biol Año: 2014 Tipo del documento: Article