Your browser doesn't support javascript.
loading
Renal biopsy with 16G needle: a safety study.
Guerrero-Ramos, F; Villacampa-Aubá, F; Jiménez-Alcaide, E; García-González, L; Ospina-Galeano, I A; de la Rosa-Kehrmann, F; Rodríguez-Antolín, A; Passas-Martínez, J; Díaz-González, R.
Afiliación
  • Guerrero-Ramos F; Servicio de Urología, Hospital Universitario 12 de Octubre, Madrid, España. Electronic address: felixguerrero@gmail.com.
  • Villacampa-Aubá F; Servicio de Urología, Hospital Universitario 12 de Octubre, Madrid, España.
  • Jiménez-Alcaide E; Servicio de Urología, Hospital Universitario 12 de Octubre, Madrid, España.
  • García-González L; Servicio de Urología, Hospital Universitario 12 de Octubre, Madrid, España.
  • Ospina-Galeano IA; Servicio de Urología, Hospital Universitario 12 de Octubre, Madrid, España.
  • de la Rosa-Kehrmann F; Servicio de Urología, Hospital Universitario 12 de Octubre, Madrid, España.
  • Rodríguez-Antolín A; Servicio de Urología, Hospital Universitario 12 de Octubre, Madrid, España.
  • Passas-Martínez J; Servicio de Urología, Hospital Universitario 12 de Octubre, Madrid, España.
  • Díaz-González R; Servicio de Urología, Hospital Universitario 12 de Octubre, Madrid, España.
Actas Urol Esp ; 38(9): 584-8, 2014 Nov.
Article en En, Es | MEDLINE | ID: mdl-24533921
ABSTRACT
INTRODUCTION AND

OBJECTIVE:

The development of percutaneous renal biopsy as a routinary diagnostic procedure for renal masses is topic of discussion for the last few years. However, this technique has been associated with some complications, although infrequent, and morbidity. Our objective is to carry out a descriptive study about complications and outcomes of orthotopic kidney biopsies with 16 G needle. MATERIAL AND

METHODS:

A retrospective review of 180 orthotopic ultrasound-guided renal biopsies performed in our service among January 2008 to May 2010 was carried out. The procedure was developed using an automated biopsy gun (16G needle). Multiple clinical variables, early post-procedure complications and its management were collected. Complication rates as well as the relationship between risk factors and occurrence of complications were studied.

RESULTS:

Mean age was 55.8 years. The average number of biopsy cylinders per intervention was 2.49. The overall complication rate was 5.6%. An interventionist attitude derived from complication of the procedure was necessary in only 3 patients (1.67%). No surgical interventions were required and no death as consequence of procedure was registered. No relationship between hypertension (P=.09) previous anticoagulation (P=.099) or previous antiaggregation (P=.603) and complications were demonstrated. In 2.8% of biopsies the material obtained was insufficient for diagnosing.

CONCLUSIONS:

Percutaneous ultrasound-guided renal biopsy with 16G needle is a safe technique with high diagnostic performance.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Biopsia con Aguja / Riñón / Enfermedades Renales Tipo de estudio: Diagnostic_studies / Observational_studies / Qualitative_research / Risk_factors_studies Límite: Adolescent / Adult / Aged / Aged80 / Humans / Middle aged Idioma: En / Es Revista: Actas Urol Esp Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Biopsia con Aguja / Riñón / Enfermedades Renales Tipo de estudio: Diagnostic_studies / Observational_studies / Qualitative_research / Risk_factors_studies Límite: Adolescent / Adult / Aged / Aged80 / Humans / Middle aged Idioma: En / Es Revista: Actas Urol Esp Año: 2014 Tipo del documento: Article