Detection of wrinkle frames in endoluminal videos using betweenness centrality measures for images.
IEEE J Biomed Health Inform ; 18(6): 1831-8, 2014 Nov.
Article en En | MEDLINE | ID: mdl-25375680
ABSTRACT
Intestinal contractions are one of the most important events to diagnose motility pathologies of the small intestine. When visualized by wireless capsule endoscopy (WCE), the sequence of frames that represents a contraction is characterized by a clear wrinkle structure in the central frames that corresponds to the folding of the intestinal wall. In this paper, we present a new method to robustly detect wrinkle frames in full WCE videos by using a new mid-level image descriptor that is based on a centrality measure proposed for graphs. We present an extended validation, carried out in a very large database, that shows that the proposed method achieves state-of-the-art performance for this task.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Endoscopía Capsular / Motilidad Gastrointestinal / Enfermedades Intestinales Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: IEEE J Biomed Health Inform Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Endoscopía Capsular / Motilidad Gastrointestinal / Enfermedades Intestinales Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: IEEE J Biomed Health Inform Año: 2014 Tipo del documento: Article