Your browser doesn't support javascript.
loading
A pressure sensing system for heart rate monitoring with polymer-based pressure sensors and an anti-interference post processing circuit.
Shu, Yi; Li, Cheng; Wang, Zhe; Mi, Wentian; Li, Yuxing; Ren, Tian-Ling.
Afiliación
  • Shu Y; Institute of Microelectronics and Tsinghua National Laboratory for Information Science and Technology (TNList), Tsinghua University, Beijing 100084, China. shuy11@mails.tsinghua.edu.cn.
  • Li C; Institute of Microelectronics and Tsinghua National Laboratory for Information Science and Technology (TNList), Tsinghua University, Beijing 100084, China. lic71317@gmail.com.
  • Wang Z; Institute of Microelectronics and Tsinghua National Laboratory for Information Science and Technology (TNList), Tsinghua University, Beijing 100084, China. wangzhe.thu2012@gmail.com.
  • Mi W; Institute of Microelectronics and Tsinghua National Laboratory for Information Science and Technology (TNList), Tsinghua University, Beijing 100084, China. miwentian@gmail.com.
  • Li Y; Institute of Microelectronics and Tsinghua National Laboratory for Information Science and Technology (TNList), Tsinghua University, Beijing 100084, China. qhlyx_1992@163.com.
  • Ren TL; Institute of Microelectronics and Tsinghua National Laboratory for Information Science and Technology (TNList), Tsinghua University, Beijing 100084, China. rentl@tsinghua.edu.cn.
Sensors (Basel) ; 15(2): 3224-35, 2015 Feb 02.
Article en En | MEDLINE | ID: mdl-25648708
ABSTRACT
Heart rate measurement is a basic and important issue for either medical diagnosis or daily health monitoring. In this work great efforts have been focused on realizing a portable, comfortable and low cost solution for long-term domestic heart rate monitoring. A tiny but efficient measurement system composed of a polymer-based flexible pressure sensor and an analog anti-interference readout circuit is proposed; manufactured and tested. The proposed polymer-based pressure sensor has a linear response and high sensitivity of 13.4 kPa-1. With the circuit's outstanding capability in removing interference caused by body movement and the highly sensitive flexible sensor device, comfortable long-term heart rate monitoring becomes more realistic. Comparative tests prove that the proposed system has equivalent capability (accuracy <3%) in heart rate measurement to the commercial product.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Frecuencia Cardíaca / Monitoreo Fisiológico Límite: Humans Idioma: En Revista: Sensors (Basel) Año: 2015 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Frecuencia Cardíaca / Monitoreo Fisiológico Límite: Humans Idioma: En Revista: Sensors (Basel) Año: 2015 Tipo del documento: Article País de afiliación: China