Your browser doesn't support javascript.
loading
High-resolution impedance manometry parameters enhance the esophageal motility evaluation in non-obstructive dysphagia patients without a major Chicago Classification motility disorder.
Carlson, D A; Omari, T; Lin, Z; Rommel, N; Starkey, K; Kahrilas, P J; Tack, J; Pandolfino, J E.
Afiliación
  • Carlson DA; Division of Gastroenterology and Hepatology, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA.
  • Omari T; Department of Human Physiology, School of Medicine, Flinders University, Bedford Park, SA, Australia.
  • Lin Z; Division of Gastroenterology and Hepatology, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA.
  • Rommel N; Department of Neurosciences, Experimental Otorhinolaryngology, Deglutology, University of Leuven, Leuven, Belgium.
  • Starkey K; Translational Research Center for Gastrointestinal Diseases (TARGID), University of Leuven, Leuven, Belgium.
  • Kahrilas PJ; Division of Gastroenterology and Hepatology, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA.
  • Tack J; Division of Gastroenterology and Hepatology, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA.
  • Pandolfino JE; Translational Research Center for Gastrointestinal Diseases (TARGID), University of Leuven, Leuven, Belgium.
Article en En | MEDLINE | ID: mdl-27647522
BACKGROUND: High-resolution impedance manometry (HRIM) allows evaluation of esophageal bolus retention, flow, and pressurization. We aimed to perform a collaborative analysis of HRIM metrics to evaluate patients with non-obstructive dysphagia. METHODS: Fourteen asymptomatic controls (58% female; ages 20-50) and 41 patients (63% female; ages 24-82), 18 evaluated for dysphagia and 23 for reflux (non-dysphagia patients), with esophageal motility diagnoses of normal motility or ineffective esophageal motility, were evaluated with HRIM and a global dysphagia symptom score (Brief Esophageal Dysphagia Questionnaire). HRIM was analyzed to assess Chicago Classification metrics, automated pressure-flow metrics, the esophageal impedance integral (EII) ratio, and the bolus flow time (BFT). KEY RESULTS: Significant symptom-metric correlations were detected only with basal EGJ pressure, EII ratio, and BFT. The EII ratio, BFT, and impedance ratio differed between controls and dysphagia patients, while the EII ratio in the upright position was the only measure that differentiated dysphagia from non-dysphagia patients. CONCLUSIONS & INFERENCES: The EII ratio and BFT appear to offer an improved diagnostic evaluation in patients with non-obstructive dysphagia without a major esophageal motility disorder. Bolus retention as measured with the EII ratio appears to carry the strongest association with dysphagia, and thus may aid in the characterization of symptomatic patients with otherwise normal manometry.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Trastornos de Deglución / Impedancia Eléctrica / Manometría Tipo de estudio: Diagnostic_studies / Observational_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Neurogastroenterol Motil Asunto de la revista: GASTROENTEROLOGIA / NEUROLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Trastornos de Deglución / Impedancia Eléctrica / Manometría Tipo de estudio: Diagnostic_studies / Observational_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Neurogastroenterol Motil Asunto de la revista: GASTROENTEROLOGIA / NEUROLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos