Quality of pediatric abdominal CT scans performed at a dedicated children's hospital and its referring institutions: a multifactorial evaluation.
Snow, Aisling; Milliren, Carly E; Graham, Dionne A; Callahan, Michael J; MacDougall, Robert D; Robertson, Richard L; Taylor, George A.
Afiliación
  • Snow A; Department of Radiology, Boston Children's Hospital, 300 Longwood Ave., Boston, MA, 02115, USA. aislingsnow@gmail.com.
  • Milliren CE; Department of Radiology, Our Lady's Children's Hospital, Crumlin, Dublin, Ireland. aislingsnow@gmail.com.
  • Graham DA; Program for Patient Safety and Quality, Boston Children's Hospital, Boston, MA, USA.
  • Callahan MJ; Program for Patient Safety and Quality, Boston Children's Hospital, Boston, MA, USA.
  • MacDougall RD; Department of Radiology, Boston Children's Hospital, 300 Longwood Ave., Boston, MA, 02115, USA.
  • Robertson RL; Department of Radiology, Boston Children's Hospital, 300 Longwood Ave., Boston, MA, 02115, USA.
  • Taylor GA; Department of Radiology, Boston Children's Hospital, 300 Longwood Ave., Boston, MA, 02115, USA.
Pediatr Radiol ; 47(4): 391-397, 2017 Apr.
Article en En | MEDLINE | ID: mdl-28084504
ABSTRACT

BACKGROUND:

Pediatric patients requiring transfer to a dedicated children's hospital from an outside institution may undergo CT imaging as part of their evaluation. Whether this imaging is performed prior to or after transfer has been shown to impact the radiation dose imparted to the patient. Other quality variables could also be affected by the pediatric experience and expertise of the scanning institution.

OBJECTIVE:

To identify differences in quality between abdominal CT scans and reports performed at a dedicated children's hospital, and those performed at referring institutions. MATERIALS AND

METHODS:

Fifty consecutive pediatric abdominal CT scans performed at outside institutions were matched (for age, gender and indication) with 50 CT scans performed at a dedicated freestanding children's hospital. We analyzed the scans for technical parameters, report findings, correlation with final clinical diagnosis, and clinical utility. Technical evaluation included use of intravenous and oral contrast agents, anatomical coverage, number of scan phases and size-specific dose estimate (SSDE) for each scan. Outside institution scans were re-reported when the child was admitted to the children's hospital; they were also re-interpreted for this study by children's hospital radiologists who were provided with only the referral information given in the outside institution's report. Anonymized original outside institutional reports and children's hospital admission re-reports were analyzed by two emergency medicine physicians for ease of understanding, degree to which the clinical question was answered, and level of confidence in the report.

RESULTS:

Mean SSDE was lower (8.68) for children's hospital scans, as compared to outside institution scans (13.29, P = 0.03). Concordance with final clinical diagnosis was significantly lower for original outside institution reports (38/48, 79%) than for both the admission and study children's hospital reports (48/50, 96%; P = 0.005). Children's hospital admission reports were rated higher than outside institution reports for completeness, ease of understanding, answering of clinical question, and level of confidence of the report (P < 0.001).

CONCLUSION:

Pediatric abdominal CT scans performed and interpreted at a dedicated children's hospital are associated with higher technical quality, lower radiation dose and a more clinically useful report than those performed at referring institutions.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Garantía de la Calidad de Atención de Salud / Derivación y Consulta / Radiografía Abdominal / Tomografía Computarizada por Rayos X / Hospitales Pediátricos Tipo de estudio: Prognostic_studies Límite: Child / Female / Humans / Male Idioma: En Revista: Pediatr Radiol Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Garantía de la Calidad de Atención de Salud / Derivación y Consulta / Radiografía Abdominal / Tomografía Computarizada por Rayos X / Hospitales Pediátricos Tipo de estudio: Prognostic_studies Límite: Child / Female / Humans / Male Idioma: En Revista: Pediatr Radiol Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos