Your browser doesn't support javascript.
loading
Comparative efficacy of Er,Cr:YSGG and Er:YAG lasers for etching of composite for orthodontic bracket bonding.
Mirhashemi, Amir Hossein; Chiniforush, Nasim; Sharifi, Nastaran; Hosseini, Amir Mehdi.
Afiliación
  • Mirhashemi AH; Laser Research Center of Dentistry, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
  • Chiniforush N; Laser Research Center of Dentistry, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
  • Sharifi N; Department of Orthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
  • Hosseini AM; , Tehran, Iran. amir.hoosseini121@gmail.com.
Lasers Med Sci ; 33(4): 835-841, 2018 May.
Article en En | MEDLINE | ID: mdl-29327089
ABSTRACT
Several techniques have been proposed to obtain a durable bond, and the efficacy of these techniques is assessed by measuring parameters such as bond strength. Laser has provided a bond strength as high as that of acid etching in vitro and has simpler use with shorter clinical time compared to acid etching. This study aimed to compare the efficacy of ErYAG and Er,CrYSGG lasers for etching and bonding of composite to orthodontic brackets. No previous study has evaluated the effect of these particular types of laser. A total of 70 composite blocks were randomly divided into five groups (n = 14) group 1, etching with phosphoric acid for 20 s; group 2, ErYAG laser irradiation with 2 W power for 10 s; group 3, ErYAG laser with 3 W power for 10 s; group 4, Er,CrYSGG laser with 2 W power for 10 s; group 5, Er,CrYSGG laser with 3 W power for 10 s. Metal brackets were then bonded to composites, and after 5000 thermal cycles, they were subjected to shear bond strength test in a universal testing machine after 24 h of water storage. One sample of each group was evaluated under a scanning electron microscope (SEM) to assess changes in composite surface after etching. The adhesive remnant index (ARI) was calculated under a stereomicroscope. Data were statistically analyzed. The mean and standard deviation of shear bond strength were 18.65 ± 3.36, 19.68 ± 5.34, 21.31 ± 4.03, 17.38 ± 6.94, and 16.45 ± 4.26 MPa in groups 1-5, respectively. The ARI scores showed that the bond failure mode in all groups was mainly mixed. The groups were not significantly different in terms of shear bond strength. ErYAG and Er,CrYSGG lasers with the mentioned parameters yield optimal shear bond strength and can be used as an alternative to acid etching for bracket bond to composite.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Recubrimiento Dental Adhesivo / Grabado Dental Límite: Humans Idioma: En Revista: Lasers Med Sci Asunto de la revista: BIOTECNOLOGIA / RADIOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Irán

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Recubrimiento Dental Adhesivo / Grabado Dental Límite: Humans Idioma: En Revista: Lasers Med Sci Asunto de la revista: BIOTECNOLOGIA / RADIOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Irán