Your browser doesn't support javascript.
loading
Universal HPLC Detector for Hydrophilic Organic Compounds by Means of Total Organic Carbon Detection.
Ohira, Shin-Ichi; Kaneda, Kyosuke; Matsuzaki, Toru; Mori, Shuta; Mori, Masanobu; Toda, Kei.
Afiliación
  • Ohira SI; Department of Chemistry , Kumamoto University , 2-39-1 Kurokami , Kumamoto , 860-8555 , Japan.
  • Kaneda K; Department of Chemistry , Kumamoto University , 2-39-1 Kurokami , Kumamoto , 860-8555 , Japan.
  • Matsuzaki T; Department of Chemistry , Kumamoto University , 2-39-1 Kurokami , Kumamoto , 860-8555 , Japan.
  • Mori S; Department of Chemistry , Kumamoto University , 2-39-1 Kurokami , Kumamoto , 860-8555 , Japan.
  • Mori M; Faculty of Science and Technology , Kochi University , 2-5-1 Akebono-cho , Kochi , 780-8520 , Japan.
  • Toda K; Department of Chemistry , Kumamoto University , 2-39-1 Kurokami , Kumamoto , 860-8555 , Japan.
Anal Chem ; 90(11): 6461-6467, 2018 06 05.
Article en En | MEDLINE | ID: mdl-29733193
ABSTRACT
Most quantifications are achieved by comparison of the signals obtained with the sample to those from a standard. Thus, the purity and stability of the standard are key in chemical analysis. Furthermore, if an analyte standard cannot be obtained, quantification cannot be achieved, even if the chemical structures are identified by a qualification method (e.g., high-resolution mass spectrometry). Herein, we describe a universal and analyte standard-free detector for aqueous-eluent-based high-performance liquid chromatography. This universal carbon detector (UCD) was developed based on total organic carbon detection. Separated analytes were oxidized in-line and converted to carbon dioxide (CO2). Generated CO2 was transferred into the gas phase and collected into ultrapure water, which was followed by conductivity detection. The system can be applied as a HPLC detector that does not use an organic solvent as an eluent. The system can be calibrated with a primary standard of sodium bicarbonate for organic compounds. The universality and quantification were evaluated with organic compounds, including organic acids, sugars, and amino acids. Furthermore, the system was successfully applied to evaluation of the purity of formaldehyde in formalin solution, and determination of sugars in juices. The results show the universal carbon detector has good universality and can quantify many kinds of organic compounds with a single standard such as sodium bicarbonate.

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Chem Año: 2018 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Chem Año: 2018 Tipo del documento: Article País de afiliación: Japón