Your browser doesn't support javascript.
loading
CT colonography: size reduction of submerged colorectal polyps due to electronic cleansing and CT-window settings.
Bräuer, Christian; Lefere, Philippe; Gryspeerdt, Stefaan; Ringl, Helmut; Al-Mukhtar, Ali; Apfaltrer, Paul; Berzaczy, Dominik; Füger, Barbara; Furtner, Julia; Müller-Mang, Christina; Pones, Matthias; Scharitzer, Martina; Woitek, Ramona; Graser, Anno; Weber, Michael; Mang, Thomas.
Afiliación
  • Bräuer C; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Lefere P; AZ Delta, Department of Radiology, Bruggesteenweg 90, 8800, Roeselare, Belgium.
  • Gryspeerdt S; AZ Delta, Department of Radiology, Bruggesteenweg 90, 8800, Roeselare, Belgium.
  • Ringl H; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Al-Mukhtar A; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Apfaltrer P; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Berzaczy D; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Füger B; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Furtner J; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Müller-Mang C; Institut für CT und MRT Gänserndorf, Umfahrungsstrasse Nord 7, 2230, Gänserndorf, Austria.
  • Pones M; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Scharitzer M; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Woitek R; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Graser A; Radiologie München, Burgstrasse 7, 80331, Munich, Germany.
  • Weber M; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Mang T; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria. thomas.mang@meduniwien.ac.at.
Eur Radiol ; 28(11): 4766-4774, 2018 Nov.
Article en En | MEDLINE | ID: mdl-29761359
ABSTRACT

OBJECTIVES:

To assess whether electronic cleansing (EC) of tagged residue and different computed tomography (CT) windows influence the size of colorectal polyps in CT colonography (CTC).

METHODS:

A database of 894 colonoscopy-validated CTC datasets of a low-prevalence cohort was retrospectively reviewed to identify patients with polyps ≥6 mm that were entirely submerged in tagged residue. Ten radiologists independently measured the largest diameter of each polyp, two-dimensionally, before and after EC in colon, bone, and soft-tissue-windows, in randomised order. Differences in size and polyp count before and after EC were calculated for size categories ≥6 mm and ≥10 mm. Statistical testing involved 95% confidence interval, intraclass correlation and mixed-model ANOVA.

RESULTS:

Thirty-seven patients with 48 polyps were included. Mean polyp size before EC was 9.8 mm in colon, 9.9 mm in bone and 8.2 mm in soft-tissue windows. After EC, the mean polyp size decreased significantly to 9.4 mm in colon, 9.1 mm in bone and 7.1 mm in soft-tissue windows. Compared to unsubtracted colon windows, EC, performed in colon, bone and soft-tissue windows, led to a shift of 6 (12,5%), 10 (20.8%) and 25 (52.1%) polyps ≥6 mm into the next smaller size category, thus affecting patient risk stratification.

CONCLUSIONS:

EC and narrow CT windows significantly reduce the size of polyps submerged in tagged residue. Polyp measurements should be performed in unsubtracted colon windows. KEY POINTS • EC significantly reduces the size of polyps submerged in tagged residue. • Abdominal CT-window settings significantly underestimate 2D sizes of submerged polyps. • Size reduction in EC is significantly greater in narrow than wide windows. • Underestimation of polyp size due to EC may lead to inadequate treatment. • Polyp measurements should be performed in unsubtracted images using a colon window.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Pólipos del Colon / Colonografía Tomográfica Computarizada Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Austria

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Pólipos del Colon / Colonografía Tomográfica Computarizada Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Austria