Your browser doesn't support javascript.
loading
Comparison of Visual Acuity Outcomes Between Nanothin Descemet Stripping Automated Endothelial Keratoplasty and Descemet Membrane Endothelial Keratoplasty.
Kurji, Khaliq H; Cheung, Albert Y; Eslani, Medi; Rolfes, Erin J; Chachare, Deepali Y; Auteri, Nicholas J; Nordlund, Michael L; Holland, Edward J.
Afiliación
  • Kurji KH; Cincinnati Eye Institute, Cincinnati, OH.
  • Cheung AY; Department of Ophthalmology, University of Cincinnati, Cincinnati, OH.
  • Eslani M; Cincinnati Eye Institute, Cincinnati, OH.
  • Rolfes EJ; Department of Ophthalmology, University of Cincinnati, Cincinnati, OH.
  • Chachare DY; Virginia Eye Consultants, Norfolk, VA.
  • Auteri NJ; Cincinnati Eye Institute, Cincinnati, OH.
  • Nordlund ML; Cincinnati Eye Institute, Cincinnati, OH.
  • Holland EJ; Cincinnati Eye Institute, Cincinnati, OH.
Cornea ; 37(10): 1226-1231, 2018 Oct.
Article en En | MEDLINE | ID: mdl-30028748
ABSTRACT

PURPOSE:

To compare the visual outcomes and complications between nanothin Descemet stripping automated endothelial keratoplasty (NT-DSAEK) and Descemet membrane endothelial keratoplasty (DMEK).

METHODS:

A prospective comparative case series of 28 consecutive cases of NT-DSAEK (less than or equal to 50 µm) and DMEK was undertaken. Inclusion criteria were a diagnosis of Fuchs dystrophy, presence of pseudophakia, or planned combined cataract surgery/endothelial keratoplasty, with a minimum of 6-month follow-up. Exclusion criteria were any concurrent ocular comorbidities. Primary outcomes measures were best spectacle-corrected visual acuity (BSCVA) and complications.

RESULTS:

Mean thickness of NT-DSAEK grafts was 41.0 ± 7.5 µm (range 26-50 µm). At 1 month postoperatively, the DMEK group had significantly better mean BSCVA of 0.18 ± 0.20 logarithm of the minimum angle of resolution (logMAR) (20/33) compared with 0.28 ± 0.16 logMAR (20/40) for NT-NSAEK (P = 0.049). At 3, 6, and 12 months postoperatively, mean BSCVA was comparable between both groups [3 months NT-DSAEK 0.17 ± 0.12 logMAR (20/30) versus DMEK 0.13 ± 0.17 (20/27), P = 0.31; 6 months NT-DSAEK 0.11 ± 0.10 logMAR (20/26) versus DMEK 0.09 ± 0.10 (20/25), P = 0.63; 12 months NT-DSAEK 0.07 ± 0.09 logMAR (20/24) versus DMEK 0.07 ± 0.11 logMAR (20/24), P = 0.95]. Other than 1 NT-DSAEK graft that was successfully rebubbled, no other complications were encountered in either group.

CONCLUSIONS:

Compared with DMEK, NT-DSAEK provides comparable visual outcomes and complications rates.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Agudeza Visual / Enfermedades de la Córnea / Lámina Limitante Posterior / Queratoplastia Endotelial de la Lámina Limitante Posterior Tipo de estudio: Observational_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Cornea Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Agudeza Visual / Enfermedades de la Córnea / Lámina Limitante Posterior / Queratoplastia Endotelial de la Lámina Limitante Posterior Tipo de estudio: Observational_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Cornea Año: 2018 Tipo del documento: Article