The lateral joint space width can be measured reliably with Telos valgus stress radiography in medial knee osteoarthritis.
Koppens, Daan; Sørensen, Ole Gade; Munk, Stig; Rytter, Søren; Larsen, Solveig Kärk Abildtrup; Stilling, Maiken; Hansen, Torben Bæk.
Afiliación
  • Koppens D; Department of Orthopaedic Surgery, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Lægårdvej 12, 7500, Holstebro, Denmark. daankopp@rm.dk.
  • Sørensen OG; Department of Clinical Medicine, Aarhus University, Incuba Skejby, building 2, Palle-Juul-Jensens Boulevard 82, 8200, Aarhus N, Denmark. daankopp@rm.dk.
  • Munk S; Department of Orthopaedic Surgery, Aarhus University Hospital, Nørrebrogade 44, 8000, Aarhus C, Denmark.
  • Rytter S; Department of Orthopaedic Surgery, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Lægårdvej 12, 7500, Holstebro, Denmark.
  • Larsen SKA; Department of Orthopaedic Surgery, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Lægårdvej 12, 7500, Holstebro, Denmark.
  • Stilling M; Department of Radiology, Hospital Unit West, Lægårdvej 12, 7500, Holstebro, Denmark.
  • Hansen TB; Department of Orthopaedic Surgery, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Lægårdvej 12, 7500, Holstebro, Denmark.
Skeletal Radiol ; 48(7): 1069-1077, 2019 Jul.
Article en En | MEDLINE | ID: mdl-30456552
ABSTRACT

OBJECTIVE:

To examine the reproducibility of valgus stress radiographs with the Telos stress device for assessment of lateral compartment degenerative changes in patients with medial osteoarthritis of the knee. MATERIALS AND

METHODS:

A prospective reliability study was performed. Seventy-nine patients (80 knees) were included, and standardized valgus stress radiographs were obtained using the Telos stress device. Osteophytes and joint space narrowing (JSN) were graded using the OARSI (Osteoarthritis Research Society International) classification, and the joint space width (JSW) was measured in millimeters. Reproducibility was determined as intra-and inter-rater reliability and test-retest reliability. Weighted kappa was used to determine the reliability of osteophyte and JSN grading, and the intra-class correlation coefficient for JSW.

RESULTS:

Grading of osteophytes had an intra- and inter-rater reliability ranging from 0.40 to 0.83 on the medial side and ranging from 0.39 to 0.87 on the lateral side. Grading of medial JSN had an intra- and inter-rater reliability ranging from 0.62 to 0.84, and grading of lateral JSN had an intra- and inter-rater reliability ranging from 0.32 to 0.65. Intra- and inter-rater reliability of JSW ranged from 0.84 to 0.98 on the medial side, and from 0.59 to 0.89 on the lateral side. Test-retest reliability of JSW of the medial and lateral side ranged from 0.69 to 0.92.

CONCLUSIONS:

Standardized valgus stress radiographs taken with the Telos stress device are a reliable supplement in the assessment of medial OA of the knee. Evaluation of the lateral compartment on valgus stress radiographs is most reliable with measurement of the lateral JSW.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Equipo Ortopédico / Osteoartritis de la Rodilla / Osteofito Tipo de estudio: Observational_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Skeletal Radiol Año: 2019 Tipo del documento: Article País de afiliación: Dinamarca

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Equipo Ortopédico / Osteoartritis de la Rodilla / Osteofito Tipo de estudio: Observational_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Skeletal Radiol Año: 2019 Tipo del documento: Article País de afiliación: Dinamarca