Your browser doesn't support javascript.
loading
A short follow-up of prosthesis-based breast reconstruction using TiLOOP® Bra surgical mesh.
Chen, W X; Cheng, L; Xu, L Y; Zhu, Y L.
Afiliación
  • Chen WX; Department of Breast Surgery, The Affiliated Changzhou No. 2 People's Hospital of Nanjing Medical University, Changzhou, China.
  • Cheng L; Department of Breast Surgery, The Affiliated Changzhou No. 2 People's Hospital of Nanjing Medical University, Changzhou, China.
  • Xu LY; Department of Breast Surgery, The Affiliated Changzhou No. 2 People's Hospital of Nanjing Medical University, Changzhou, China.
  • Zhu YL; Department of Breast Surgery, The Affiliated Changzhou No. 2 People's Hospital of Nanjing Medical University, Changzhou, China.
Niger J Clin Pract ; 22(8): 1115-1119, 2019 Aug.
Article en En | MEDLINE | ID: mdl-31417055
ABSTRACT

BACKGROUND:

A new approach for prosthesis-based breast reconstruction is the use of a titanium-coated polypropylene mesh TiLOOP® Bra. However, the safety and outcomes are currently unclear in Chinese breast cancer patients.

METHODS:

A retrospective study of patients undergoing prosthesis-based breast reconstruction using TiLOOP® Bra was carried out. Complications were divided into minor complications (require conservative treatment) and major complications (require surgical intervention). The influence of patient- and surgery-related characteristics on complications was analyzed.

RESULTS:

Postoperative hematoma and seroma were respectively found in one and two breasts and could be treated conservatively. In three breasts skin infection occurred immediately after surgery resulting in skin necrosis of two breasts and wound dehiscence of one breast. These three breasts were treated with mesh removal, and revisionary surgery. Increased risk of mesh removal and implant explantation were observed in case of skin infection (P = 0.011) and skin necrosis (P = 0.033). Neither patient-related characteristics including age >50 years, BMI >25 kg/m2, and postoperative radiotherapy/chemotherapy, nor surgery-related characteristics including sentinel lymph node biopsy or axillary dissection alone, and curative/prophylactic surgery were significantly correlated with minor and major complications. Ultrasound evaluation showed a well-incorporated mesh into surrounding tissue.

CONCLUSION:

This titanium-coated polypropylene mesh showed acceptable complications and could be used safely in prosthesis-based breast reconstruction by stabilizing the implant pocket. Longer follow-up data and more randomized trials are necessary to determine the clinical use of this mesh.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Polipropilenos / Mallas Quirúrgicas / Titanio / Mamoplastia / Implantes de Mama / Materiales Biocompatibles Revestidos Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Niger J Clin Pract Asunto de la revista: MEDICINA Año: 2019 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Polipropilenos / Mallas Quirúrgicas / Titanio / Mamoplastia / Implantes de Mama / Materiales Biocompatibles Revestidos Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Niger J Clin Pract Asunto de la revista: MEDICINA Año: 2019 Tipo del documento: Article País de afiliación: China