Your browser doesn't support javascript.
loading
Comparison of efficacy of supraspinatus tendon tears diagnostic tests: a prospective study on the "full-can," the "empty-can," and the "Whipple" tests.
Ackmann, T; Schneider, K N; Schorn, D; Rickert, C; Gosheger, G; Liem, D.
Afiliación
  • Ackmann T; Department of General Orthopedics and Tumor Orthopedics, Muenster University Hospital, Münster, Germany. Thomas.Ackmann@ukmuenster.de.
  • Schneider KN; Department of General Orthopedics and Tumor Orthopedics, Muenster University Hospital, Münster, Germany.
  • Schorn D; Department of General Orthopedics and Tumor Orthopedics, Muenster University Hospital, Münster, Germany.
  • Rickert C; Department of General Orthopedics and Tumor Orthopedics, Muenster University Hospital, Münster, Germany.
  • Gosheger G; Department of General Orthopedics and Tumor Orthopedics, Muenster University Hospital, Münster, Germany.
  • Liem D; Sporthopaedicum Berlin, Berlin, Germany.
Musculoskelet Surg ; 105(2): 149-153, 2021 Aug.
Article en En | MEDLINE | ID: mdl-31691179
ABSTRACT

PURPOSE:

This study compares the clinical results of the Whipple, empty-can, and full-can tests to detect supraspinatus tendon tears. We determined the sensitivities, specificities, and positive and negative predictive values of each test with respect to the intraoperative supraspinatus tendon lesion confirmation.

METHODS:

We examined 61 patients (26 women, 35 men) presenting for arthroscopic surgery with functional disability or persisting shoulder pain. All the patients underwent Whipple, empty-can, and full-can testing. We correlated the clinical results of the tests with the confirmation of a supraspinatus tendon lesion by direct arthroscopic visualization.

RESULTS:

We examined 34 right and 27 left shoulders. For full and partial supraspinatus tendon tears, the Whipple test showed a sensitivity of 88.6% and a specificity of 29.4%, whereas the empty-can test and the full-can test had sensitivities of 88.6% and 75.0%, and specificities of 58.8% and 47.1%, respectively.

CONCLUSIONS:

Compared with the empty-can test and the full-can test, the Whipple test was less specific, while its sensitivity was equal to that of the empty-can test and higher than that for the full-can test. Because of its low specificity, the Whipple test has a high risk of false-positive results in comparison with the other tests.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Traumatismos de los Tendones / Lesiones del Manguito de los Rotadores Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Male Idioma: En Revista: Musculoskelet Surg Asunto de la revista: ORTOPEDIA Año: 2021 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Traumatismos de los Tendones / Lesiones del Manguito de los Rotadores Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Male Idioma: En Revista: Musculoskelet Surg Asunto de la revista: ORTOPEDIA Año: 2021 Tipo del documento: Article País de afiliación: Alemania