Your browser doesn't support javascript.
loading
Effective Temperature and Structural Rearrangement in Trapped Ion Mobility Spectrometry.
Morsa, Denis; Hanozin, Emeline; Eppe, Gauthier; Quinton, Loïc; Gabelica, Valérie; Pauw, Edwin De.
Afiliación
  • Morsa D; Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liège 4000, Belgium.
  • Hanozin E; Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liège 4000, Belgium.
  • Eppe G; Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liège 4000, Belgium.
  • Quinton L; Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liège 4000, Belgium.
  • Gabelica V; University of Bordeaux, INSERM and CNRS, Laboratoire Acides Nucléiques: Régulations Naturelles et Artificielles (ARNA, U1212, UMR5320), IECB, Pessac 33600, France.
  • Pauw E; Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liège 4000, Belgium.
Anal Chem ; 92(6): 4573-4582, 2020 03 17.
Article en En | MEDLINE | ID: mdl-32083849
ABSTRACT
Modern ion mobility instrumentation is typically operated above the low field limit, which may activate the ions and cause structural rearrangement or fragmentation during analysis. Here, we quantitatively assessed the internal heating experienced by ions during trapped ion mobility spectrometry (TIMS) experiments. To this end, the fragmentation yields of fragile benzylpyridinium "thermometer" ions were monitored during both the accumulation and analysis steps inside the TIMS tunnel. The corresponding fragmentation rate constants were translated into a vibrational effective temperature Teff,vib. Our results demonstrate significant fragmentation upstream and inside the TIMS tunnel that corresponds to Teff,vib ≈ 510 K during both the accumulation and analysis steps. Broadening our scope to cytochrome c and lysozyme, we showed that although compact "native" folds can be preserved, the collision cross section distributions are highly sensitive to the transmission voltages and the analysis time scale. Our results are discussed with regard to Teff,vib data previously acquired on traveling-wave (TWIMS) ion mobility in the context of native mass spectrometry and conformational landscape exploration.

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Anal Chem Año: 2020 Tipo del documento: Article País de afiliación: Bélgica

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Anal Chem Año: 2020 Tipo del documento: Article País de afiliación: Bélgica