Your browser doesn't support javascript.
loading
Determination of normal values of optic nerve sheath diameter in newborns with bedside ultrasonography.
Yapicioglu, Hacer; Aslan, Nagehan; Sertdemir, Yasar; Yildizdas, Dincer; Gulasi, Selvi; Mert, Kurthan.
Afiliación
  • Yapicioglu H; Cukurova University, Faculty of Medicine, Department of Pediatrics, Division of Neonatology, Turkey.
  • Aslan N; Cukurova University, Faculty of Medicine, Department of Pediatrics, Division of Pediatric Intensive Care, Turkey. Electronic address: nagehan_aslan@hotmail.com.
  • Sertdemir Y; Cukurova University, Faculty of Medicine, Department of Biostatistics, Turkey.
  • Yildizdas D; Cukurova University, Faculty of Medicine, Department of Pediatrics, Division of Pediatric Intensive Care, Turkey.
  • Gulasi S; Adana City Training and Research Hospital, Department of Pediatrics, Division of Neonatology, Adana, Turkey.
  • Mert K; Adana City Training and Research Hospital, Department of Pediatrics, Division of Neonatology, Adana, Turkey.
Early Hum Dev ; 145: 104986, 2020 06.
Article en En | MEDLINE | ID: mdl-32335478
ABSTRACT

OBJECTIVES:

Bedside sonographic opthalmic ultrasound measurement of optic nerve sheath diameter (ONSD) is an easy, portabl, noninvasive and a radiation free technique to determine increased intracranial pressure. This prospective, multicenter study was aimed to establish the range of normal values for ONSD in preterm and term newborns with a large study population.

METHODS:

Newborns without intracranial pathology in the Newborn Intensive Care Units and in Obstetrics and Gynecology Departments were enrolled in the study. ONSD was measured at 3 mm distance behind of the right optic nerve head. As 3 mm distance was beyond the optic nerve head in some of the premature newborns, we had also measurements at 2 and 2.5 mm.

RESULTS:

ONSD was measured in 554 newborns. Mean ONSD of preterm babies at 2, 2.5 and 3 mm distances were 3.2 ± 0.3 mm (range 2.0-4.2 mm), 3.3 ± 0.3 mm (range 2.2-4.5 mm) and 3.6 ± 0.2 mm (range 2.9-4.5 mm), (p2.0-2.5 mm < 0.001, p 2.5-3.0mm < 0.001, p2.0-3.0 mm < 0.001) respectively. Mean ONSD of term babies at 3 mm was higher than the mean ONSD of preterm babies in 33 weeks 0 day- 37 weeks 0 days group (p < 0.001). In correlation analysis, a significant, strong and positive correlation was found between ONSD measurements and gestational age, weight, height and head circumference at 2, 2.5 and 3 mm distances.

CONCLUSION:

The normal values reported by the present study may be used for evaluating the ONSD of newborns with different conditions with increased incracranial pressure.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Nervio Óptico / Ultrasonografía / Pruebas en el Punto de Atención Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies Límite: Female / Humans / Male / Newborn Idioma: En Revista: Early Hum Dev Año: 2020 Tipo del documento: Article País de afiliación: Turquía

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Nervio Óptico / Ultrasonografía / Pruebas en el Punto de Atención Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies Límite: Female / Humans / Male / Newborn Idioma: En Revista: Early Hum Dev Año: 2020 Tipo del documento: Article País de afiliación: Turquía