Your browser doesn't support javascript.
loading
Analysis of Dynamic Changes in Cognitive Workload During Cardiac Surgery Perfusionists' Interactions With the Cardiopulmonary Bypass Pump.
Kennedy-Metz, Lauren R; Dias, Roger D; Srey, Rithy; Rance, Geoffrey C; Conboy, Heather M; Haime, Miguel E; Quin, Jacquelyn A; Yule, Steven J; Zenati, Marco A.
Afiliación
  • Kennedy-Metz LR; 20028 VA Boston Healthcare System, Massachusetts, USA.
  • Dias RD; Harvard Medical School, Boston, Massachusetts, USA.
  • Srey R; Harvard Medical School, Boston, Massachusetts, USA.
  • Rance GC; 20028 VA Boston Healthcare System, Massachusetts, USA.
  • Conboy HM; 20028 VA Boston Healthcare System, Massachusetts, USA.
  • Haime ME; 14707 University of Massachusetts, Amherst, USA.
  • Quin JA; 20028 VA Boston Healthcare System, Massachusetts, USA.
  • Yule SJ; 20028 VA Boston Healthcare System, Massachusetts, USA.
  • Zenati MA; Harvard Medical School, Boston, Massachusetts, USA.
Hum Factors ; 63(5): 757-771, 2021 08.
Article en En | MEDLINE | ID: mdl-33327770
ABSTRACT

OBJECTIVE:

This novel preliminary study sought to capture dynamic changes in heart rate variability (HRV) as a proxy for cognitive workload among perfusionists while operating the cardiopulmonary bypass (CPB) pump during real-life cardiac surgery.

BACKGROUND:

Estimations of operators' cognitive workload states in naturalistic settings have been derived using noninvasive psychophysiological measures. Effective CPB pump operation by perfusionists is critical in maintaining the patient's homeostasis during open-heart surgery. Investigation into dynamic cognitive workload fluctuations, and their relationship with performance, is lacking in the literature.

METHOD:

HRV and self-reported cognitive workload were collected from three Board-certified cardiac perfusionists (N = 23 cases). Five HRV components were analyzed in consecutive nonoverlapping 1-min windows from skin incision through sternal closure. Cases were annotated according to predetermined phases prebypass, three phases during bypass, and postbypass. Values from all 1min time windows within each phase were averaged.

RESULTS:

Cognitive workload was at its highest during the time between initiating bypass and clamping the aorta (preclamp phase during bypass), and decreased over the course of the bypass period.

CONCLUSION:

We identified dynamic, temporal fluctuations in HRV among perfusionists during cardiac surgery corresponding to subjective reports of cognitive workload. Not only does cognitive workload differ for perfusionists during bypass compared with pre- and postbypass phases, but differences in HRV were also detected within the three bypass phases. APPLICATION These preliminary findings suggest the preclamp phase of CPB pump interaction corresponds to higher cognitive workload, which may point to an area warranting further exploration using passive measurement.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Puente Cardiopulmonar / Procedimientos Quirúrgicos Cardíacos Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Hum Factors Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Puente Cardiopulmonar / Procedimientos Quirúrgicos Cardíacos Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Hum Factors Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos