Your browser doesn't support javascript.
loading
Proficiency Testing to Assess Technical Performance for CTC-Processing and Detection Methods in CANCER-ID.
Neves, Rui P L; Ammerlaan, Wim; Andree, Kiki C; Bender, Sebastian; Cayrefourcq, Laure; Driemel, Christiane; Koch, Claudia; Luetke-Eversloh, Merlin Verena; Oulhen, Marianne; Rossi, Elisabetta; Alix-Panabières, Catherine; Betsou, Fay; Farace, Françoise; Riethdorf, Sabine; Schlange, Thomas; Wikman, Harriet; Zamarchi, Rita; Pantel, Klaus; Terstappen, Leon W M M; Stoecklein, Nikolas H.
Afiliación
  • Neves RPL; Department of General, Visceral and Paediatric Surgery, University Hospital and Medical Faculty of the Heinrich-Heine University Düsseldorf, Düsseldorf, Germany.
  • Ammerlaan W; Integrated BioBank of Luxembourg, Dudelange, Luxembourg.
  • Andree KC; Department of Medical Cell BioPhysics, University of Twente, Enschede, The Netherlands.
  • Bender S; Bayer AG, Biomarker Research, Wuppertal, Germany.
  • Cayrefourcq L; Laboratory of Rare Human Circulating Cells, University Medical Centre of Montpellier, Montpellier, France.
  • Driemel C; Department of General, Visceral and Paediatric Surgery, University Hospital and Medical Faculty of the Heinrich-Heine University Düsseldorf, Düsseldorf, Germany.
  • Koch C; Institute of Tumor Biology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Luetke-Eversloh MV; Bayer AG, Biomarker Research, Wuppertal, Germany.
  • Oulhen M; Gustave Roussy, Université Paris-Saclay, "Circulating Tumor Cells" Translational Platform, CNRS UMS3655-INSERM US23 AMMICA, Villejuif, France.
  • Rossi E; Department of Surgery, Oncology and Gastroenterology, University of Padova, Padua, Italy.
  • Alix-Panabières C; Veneto Institute of Oncology IOV-IRCCS, Padua, Italy.
  • Betsou F; Laboratory of Rare Human Circulating Cells, University Medical Centre of Montpellier, Montpellier, France.
  • Farace F; Integrated BioBank of Luxembourg, Dudelange, Luxembourg.
  • Riethdorf S; Gustave Roussy, Université Paris-Saclay, "Circulating Tumor Cells" Translational Platform, CNRS UMS3655-INSERM US23 AMMICA, Villejuif, France.
  • Schlange T; Institute of Tumor Biology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Wikman H; Bayer AG, Biomarker Research, Wuppertal, Germany.
  • Zamarchi R; Institute of Tumor Biology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Pantel K; Veneto Institute of Oncology IOV-IRCCS, Padua, Italy.
  • Terstappen LWMM; Institute of Tumor Biology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Stoecklein NH; Department of Medical Cell BioPhysics, University of Twente, Enschede, The Netherlands.
Clin Chem ; 67(4): 631-641, 2021 03 31.
Article en En | MEDLINE | ID: mdl-33491069
BACKGROUND: Multiple technologies are available for detection of circulating tumor cells (CTCs), but standards to evaluate their technical performance are still lacking. This limits the applicability of CTC analysis in clinic routine. Therefore, in the context of the CANCER-ID consortium, we established a platform to assess technical validity of CTC detection methods in a European multi-center setting using non-small cell lung cancer (NSCLC) as a model. METHODS: We characterized multiple NSCLC cell lines to define cellular models distinct in their phenotype and molecular characteristics. Standardized tumor-cell-bearing blood samples were prepared at a central laboratory and sent to multiple European laboratories for processing according to standard operating procedures. The data were submitted via an online tool and centrally evaluated. Five CTC-enrichment technologies were tested. RESULTS: We could identify 2 cytokeratin expressing cell lines with distinct levels of EpCAM expression: NCI-H441 (EpCAMhigh, CKpos) and NCI-H1563 (EpCAMlow, CKpos). Both spiked tumor cell lines were detected by all technologies except for the CellSearch system that failed to enrich EpCAMlow NCI-H1563 cells. Mean recovery rates ranged between 49% and 75% for NCI-H411 and 32% and 76% for NCI-H1563 and significant differences were observed between the tested methods. CONCLUSIONS: This multi-national proficiency testing of CTC-enrichment technologies has importance in the establishment of guidelines for clinically applicable (pre)analytical workflows and the definition of minimal performance qualification requirements prior to clinical validation of technologies. It will remain in operation beyond the funding period of CANCER-ID in the context of the European Liquid Biopsy Society (ELBS).
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Carcinoma de Pulmón de Células no Pequeñas / Neoplasias Pulmonares / Células Neoplásicas Circulantes Tipo de estudio: Diagnostic_studies / Guideline / Prognostic_studies Límite: Humans Idioma: En Revista: Clin Chem Asunto de la revista: QUIMICA CLINICA Año: 2021 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Carcinoma de Pulmón de Células no Pequeñas / Neoplasias Pulmonares / Células Neoplásicas Circulantes Tipo de estudio: Diagnostic_studies / Guideline / Prognostic_studies Límite: Humans Idioma: En Revista: Clin Chem Asunto de la revista: QUIMICA CLINICA Año: 2021 Tipo del documento: Article País de afiliación: Alemania