Your browser doesn't support javascript.
loading
Prolonged storage of purified granulocyte concentrates: Introduction of a new purification method.
Klinkmann, Gerd; Doss, Fanny; Goudeva, Lilia; Doss, Sandra; Blasczyk, Rainer; Milej, Magdalena; Koch, Stephanie; Mitzner, Steffen; Altrichter, Jens.
Afiliación
  • Klinkmann G; Department of Anaesthesiology and Intensive Care Medicine, University of Rostock, Rostock, Germany.
  • Doss F; Artcline GmbH, Rostock, Germany.
  • Goudeva L; Institute of Transfusion Medicine and Transplant Engineering, Hannover Medical School, Hannover, Germany.
  • Doss S; Artcline GmbH, Rostock, Germany.
  • Blasczyk R; Department of Extracorporeal Immunomodulation, Fraunhofer Institute for Cell Therapy and Immunology, Rostock, Germany.
  • Milej M; Institute of Transfusion Medicine and Transplant Engineering, Hannover Medical School, Hannover, Germany.
  • Koch S; Artcline GmbH, Rostock, Germany.
  • Mitzner S; Department of Extracorporeal Immunomodulation, Fraunhofer Institute for Cell Therapy and Immunology, Rostock, Germany.
  • Altrichter J; Artcline GmbH, Rostock, Germany.
Transfusion ; 62(1): 194-204, 2022 01.
Article en En | MEDLINE | ID: mdl-34783358
BACKGROUND: Use of donor granulocyte concentrate (GC) has been limited due to its short storage time of 6-24 h, which is partially due to residual red blood cells (RBCs) and platelets and the resulting lactate production leading to an acidotic milieu. To increase this storage time, we developed a closed system procedure compatible with standard blood bank technologies to remove RBC and platelets and to enrich the GC. METHODS: Standard GCs (sGCs) were sedimented, washed twice with 0.9% sodium chloride (NaCl), and resuspended in blood group-identical fresh frozen plasma. The resulting purified GCs (pGCs) were then stored in platelet bags at a cell concentration of about 5 × 107  ± 1.8 × 107 leukocytes/ml without agitation at room temperature for up to 72 h. Cell count and viability, pH, blood gases, phagocytosis, and oxidative burst were monitored daily. RESULTS: A significant reduction in RBC (98%) through sedimentation, and platelets (96%) by washing, purified the white blood cell (WBC) population and enriched the granulocytes to 96% of the WBC in the pGC. After 72 h of storage, over 90% of the initial WBC count of pGC remained, was viable (≥97%), and the granulocytes exhibited a high phagocytosis and oxidative burst functionality, comparable to sGC after 24 h. CONCLUSION: Purification extends the maximum storage period of GC from 24 to 72 h and may therefore improve the availability of GC and its clinical use.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Plaquetas / Granulocitos Límite: Humans Idioma: En Revista: Transfusion Año: 2022 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Plaquetas / Granulocitos Límite: Humans Idioma: En Revista: Transfusion Año: 2022 Tipo del documento: Article País de afiliación: Alemania