Patella Fracture Identified Using Point-of-care Ultrasound.
Prague Med Rep
; 122(4): 308-312, 2021.
Article
en En
| MEDLINE
| ID: mdl-34924109
ABSTRACT
A 49-year-old female fell from standing. Her right knee extended into the air. She had acute right knee pain preventing weight-bearing. Her knee was most comfortable fully-extended. She could not flex it due to pain, nor extend it against resistance. Tenderness and a horizontal defect were noted over the anterior knee. Bedside ultrasound demonstrated a horizontally-fractured patella (confirmed on X-ray) with intact femoral and patellar tendons. She was put in a knee immobilizer and underwent surgery, with return to full function and activities. Ultrasound can identify patella fractures and help with early evaluation, management, and specialty referral, as well as ordering more-focused imaging. In one study, POCUS (point-of-care ultrasound) for patella fracture had 95% sensitivity, 63% specificity, 86% positive predictive value, and 83% negative predictive value. The dynamic nature of ultrasound allows a ruptured patella (87% sensitivity) or quadriceps tendon (100% sensitivity) to be excluded with high certainty.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Rótula
/
Sistemas de Atención de Punto
Tipo de estudio:
Prognostic_studies
Límite:
Humans
/
Middle aged
Idioma:
En
Revista:
Prague Med Rep
Asunto de la revista:
MEDICINA
Año:
2021
Tipo del documento:
Article
País de afiliación:
Estados Unidos