ABSTRACT
The current study presents a periodic mesoporous organosilica (PMO) with a high surface area and uniform-porosity material. The PMO materials were successfully synthesized and modified. The resultant material was characterized by different characterization techniques. The prepared PMO was immobilized on a stainless steel wire surface and was evaluated for headspace solid-phase microextraction of the ultra-trace amount of phthalate esters from saliva and polyethylene terephthalate containers which were in contact with hot and cold water. Separation and determination of the phthalate esters (PEs) were performed by the GC-FID and GC-MS instruments. The key parameters affecting the extraction efficiencies, including extraction temperature, extraction time, ionic strength, and desorption temperature and time, were investigated and optimized. Under optimum conditions, the repeatability for one fiber (n = 7) was 4.8-8.7%, and fiber-to-fiber reproducibility (n = 3) was 7.5-10.6% for the extracted compounds. The limits of detection of the developed method for the studied compounds were between 0.01 and 1 µg L-1. The results showed suitable coefficients of determination (R2 ≥ 0.99) for all of the analytes in the 0.05-300 µg L-1 calibration range. Acceptable recovery values of 91-107%, 82-110%, and 98-104% were obtained in saliva, polyethylene terephthalate containers hot water, and cold water, respectively.