Your browser doesn't support javascript.
loading
Development of a Highly Sensitive and Rapid Liquid Chromatography-Tandem Mass Spectrometric Method Using a Basic Mobile Phase Additive to Determine the Characteristics of the Urinary Metabolites for Niemann-Pick Disease Type C.
Maekawa, Masamitsu; Miyoshi, Keitaro; Narita, Aya; Sato, Toshihiro; Sato, Yu; Kumondai, Masaki; Kikuchi, Masafumi; Higaki, Katsumi; Okuyama, Torayuki; Eto, Yoshikatsu; Sakamaki, Hiroshi; Mano, Nariyasu.
Afiliación
  • Maekawa M; Department of Pharmaceutical Sciences, Tohoku University Hospital.
  • Miyoshi K; Faculty of Pharmaceutical Sciences, Tohoku University.
  • Narita A; Faculty of Pharmaceutical Sciences, Tohoku University.
  • Sato T; Division of Child Neurology, Tottori University Hospital.
  • Sato Y; Department of Pharmaceutical Sciences, Tohoku University Hospital.
  • Kumondai M; Department of Pharmaceutical Sciences, Tohoku University Hospital.
  • Kikuchi M; Department of Pharmaceutical Sciences, Tohoku University Hospital.
  • Higaki K; Department of Pharmaceutical Sciences, Tohoku University Hospital.
  • Okuyama T; Faculty of Pharmaceutical Sciences, Tohoku University.
  • Eto Y; Division of Functional Genomics, Research Centre for Bioscience and Technology, Faculty of Medicine, Tottori University.
  • Sakamaki H; Department of Clinical Laboratory Medicine, National Center for Child Health and Development.
  • Mano N; Advanced Clinical Research Center, Institute for Neurological Disorders.
Biol Pharm Bull ; 45(9): 1259-1268, 2022.
Article en En | MEDLINE | ID: mdl-36047194
ABSTRACT
As Niemann-Pick disease type C (NPC) is difficult to diagnose owing to its various clinical symptoms; biomarker tests have been developed. Previously, we revealed urinary sulfated cholesterol metabolites as noninvasive biomarkers for NPC. However, LC/tandem mass spectrometry (LC/MS/MS) requires long separation time and large urine volumes. Recently, a basic mobile phase was reported to increase the MS intensity. Thus, we developed a highly sensitive and rapid LC/MS/MS method for analyzing urinary cholesterol metabolites using a basic mobile phase additive. 3ß-Sulfooxy-7ß-N-acetylglucosaminyl-5-cholenic acid, its glycine and taurine conjugates, 3ß-sulfooxy-7ß-hydroxy-5-cholenic acid, and 7-oxo form were measured, with selected reaction monitoring in negative ion mode. Oasis HLB and L-column 3 were used for column-switching LC/MS/MS and urine diluted 10-fold was employed as the sample. After trapping, gradient separation was performed using solutions containing 1% (v/v) ammonium solution. On average, a 16-fold increase in peak areas was observed compared to that obtained at pH 5.5 with the mobile phases. Although the previous method needed 60 min for separation from interference peaks, we succeeded to separate them in 7 min with optimized LC condition. Further, all compounds showed good linearity from 0.3-1000 ng/mL, with satisfactory intra- and inter-day reproducibility. The developed method was applied to the urinalysis of healthy participants and NPC patients. Overall, the concentrations of metabolites correlated with those obtained using the previous method. Therefore, we succeeded to increasing MS intensity and shorten LC running time; and the method is useful for the noninvasive diagnostic screening of patients with NPC.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Enfermedad de Niemann-Pick Tipo C / Espectrometría de Masas en Tándem Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Biol Pharm Bull Asunto de la revista: BIOQUIMICA / FARMACOLOGIA Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Enfermedad de Niemann-Pick Tipo C / Espectrometría de Masas en Tándem Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Biol Pharm Bull Asunto de la revista: BIOQUIMICA / FARMACOLOGIA Año: 2022 Tipo del documento: Article