Your browser doesn't support javascript.
loading
Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty-MRI versus ultrasonography performed by an orthopedic surgery resident.
Mikkelsen, Rasmus T; Schou, Martin; Torfing, Trine; Graumann, Ole; Overgaard, Søren; Varnum, Claus.
Afiliación
  • Mikkelsen RT; Department of Orthopedic Surgery, Lillebaelt Hospital, Vejle, Denmark.
  • Schou M; Department of Regional Health Research, Faculty of Health Science, University of Southern Denmark, Odense, Denmark.
  • Torfing T; Department of Orthopedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark.
  • Graumann O; Department of Emergency Medicine, Holbaek Hospital, Holbaek, Denmark.
  • Overgaard S; Department of Radiology, Odense University Hospital, Odense, Denmark.
  • Varnum C; Department of Radiology, Odense University Hospital, Odense, Denmark.
Acta Radiol Open ; 12(2): 20584601231152396, 2023 Feb.
Article en En | MEDLINE | ID: mdl-36776533
ABSTRACT

Background:

Metal artifact reduction sequence magnetic resonance imaging (MRI) scan is a common method to detect adverse reaction to metal debris in total hip arthroplasty (THA). It might be quicker and cheaper if ultrasonography (US) could screen for the need for an MRI. However, both require trained personnel.

Purpose:

We aimed to investigate the sensitivity and specificity of US for detecting pseudotumors (PT) when performed by an orthopedic surgery resident compared to MRI. We also investigated the sensitivity and specificity of US to detect PTs in obese and non-obese patients. Material and

methods:

We examined 205 patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene THA with both MRI and US. US was performed by an orthopedic surgery resident who was trained according to a standardized training program in musculoskeletal US. Results from MRI were used as gold standard.

Results:

US had a sensitivity of 0.92 (95% CI 0.81-0.98) and specificity of 0.94 (95% CI 0.89-0.97) for detecting PT. It had a positive predictive value of 0.84 (95% CI 0.73-0.91) and a negative predictive value of 0.97 (95% CI 0.93-0.99). US performed similarly in obese and non-obese patients.

Conclusions:

US had a high sensitivity and specificity for detecting PT when performed by an orthopedic surgery resident. Trained orthopedic surgeons could screen for the need of an MRI scan when searching PTs.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Acta Radiol Open Año: 2023 Tipo del documento: Article País de afiliación: Dinamarca

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Acta Radiol Open Año: 2023 Tipo del documento: Article País de afiliación: Dinamarca