Your browser doesn't support javascript.
loading
Simultaneous voltammetric determination of 7-methyl-guanine and 5-methyl-cytosine using a cathodically pre-treated boron-doped diamond electrode.
Oliveira, José Eudes S; Araújo, Alex P; Alves, Arthur S; Silva, Maycom W F; Almeida, João Paulo B de; Nascimento, José Ailton M; Dos Santos, Vagner B; Oliveira, Severino Carlos B.
Afiliación
  • Oliveira JES; Department of Chemistry, Federal Rural University of Pernambuco, Recife, PE, Brazil.
  • Araújo AP; Department of Chemistry, Federal Rural University of Pernambuco, Recife, PE, Brazil.
  • Alves AS; Department of Chemistry, Federal Rural University of Pernambuco, Recife, PE, Brazil.
  • Silva MWF; Department of Chemistry, Federal Rural University of Pernambuco, Recife, PE, Brazil.
  • Almeida JPB; Fundamental Chemistry Department, Federal University of Pernambuco, Recife, PE, Brazil.
  • Nascimento JAM; Department of Chemistry, Federal Rural University of Pernambuco, Recife, PE, Brazil.
  • Dos Santos VB; Fundamental Chemistry Department, Federal University of Pernambuco, Recife, PE, Brazil.
  • Oliveira SCB; Department of Chemistry, Federal Rural University of Pernambuco, Recife, PE, Brazil. Electronic address: s.carlosb.oliveira@gmail.com.
Anal Biochem ; 671: 115135, 2023 06 15.
Article en En | MEDLINE | ID: mdl-37019253
Given the importance of identifying the presence of biomarkers of human diseases in DNA samples, the main objective of this work was to investigate, for the first time, the electro-catalytic oxidation of 7-methyl-guanine (7-mGua) and 5-methyl-cytosine (5-mCyt) on a boron doped diamond electrode pre-treated cathodically (red-BDDE), using differential pulse voltammetry (DPV) and cyclic voltammetry (CV). The anodic peak potentials of 7-mGua and 5-mCyt by DPV were at E = 1.04 V and E = 1.37 V at pH = 4.5, indicating excellent peak separation of approximately 330 mV between species. Using DPV, experimental conditions such as supporting electrolyte, pH and influence of interferents were also investigated to develop a sensitive and selective method for individual and simultaneous quantification of these biomarkers. The analytical curves for the simultaneous quantification of 7-mGua and 5-mCyt in the acid medium (pH = 4.5) were: concentration range of 0.50-5.00 µmol L-1 (r = 0.999), detection limit of 0.27 µmol L-1 for 7-mGua; from 3.00 to 25.00 µmol L-1 (r = 0.998), with a detection limit of 1.69 µmol L-1 for 5-mCyt. A new DP voltammetric method for the simultaneous detection and quantification of biomarkers 7-mGua and 5-mCyt using a red-BDDE is proposed.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Boro / 5-Metilcitosina Límite: Humans Idioma: En Revista: Anal Biochem Año: 2023 Tipo del documento: Article País de afiliación: Brasil

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Boro / 5-Metilcitosina Límite: Humans Idioma: En Revista: Anal Biochem Año: 2023 Tipo del documento: Article País de afiliación: Brasil